GEMC-511687771070194
Awarded to Microline Office Solutions
₹42,300
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Bio Plus Clock Blood Pressure Machine | Bio Plus Clock Blood Pressure Machine | - | 45 NOS | ₹940 | 42,300 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹42,300Qualified Make: Bio Plus
Model: Bio Plus Clock Blood Pressure Machine 29E B WARD NO 1 DESU ROAD NEW DELHI DELHI 110030 | SOUTH DELHI | DELHI | 110030 | Make: Bio Plus
Model: Bio Plus Clock Blood Pressure Machine | L1 | Qualified | |
| 2 | L2₹44,550+₹2,250 (5.32%)Qualified Make: MCP
Model: MCP04 C 53 A MANSAROVAR GARDEN WEST DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: MCP
Model: MCP04 | L2 | Qualified | |
| 3 | L3₹62,055+₹19,755 (46.7%)Qualified Make: Life line
Model: lifeline clock model 16 90 2ND FLOOR SUBHASH NAGAR NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | Make: Life line
Model: lifeline clock model | L3 | Qualified | |
| 4 | L4₹66,600+₹24,300 (57.4%)Qualified Make: Life line
Model: lifeline clock model 00 PC GROUP AKHARI BYPASS TRIMUHANI CHUNAR ROAD VARANASI VARANASI VARANASI UTTAR PRADESH 221011 | VARANASI | UTTAR PRADESH | 221011 | Make: Life line
Model: lifeline clock model | L4 | Qualified | |
| 5 | Disqualified Make: Heine
Model: HEINE GUPTA ARCADE EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Heine
Model: HEINE | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
15 Oct 2018, 10:00 amClosed
blood pressure recording units Blood Pressure Recording Units ( 45 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Aneroid Aneroid Conformity to Indian Standrad for SPHYG MOMANOMETERS IS 7652 latest for Aneroid IS 7652 latest for Aneroid Measuring device Mechnical Mechnical
Automated Type Portable Portable
Mountable/Fixed
Inclined
Integrated ISI MARKED Yes Yes
NA for digital CM/L No and validity date 8677709 31/10/2017 * Measurement Method Auscultatory method Oscillometric
Auscultatory method
others Display for Digital BP instrument: NA for others LCD(Liquid Crystal Digital) Display
NA for others 1/5 Range: Pressure measurement (mmHg) 0 to 300 * Range:Pulse measurement for digital with accuracy ± 5%. (per minute) 40 to 200 * Accuracy:Pressure measurement (mmHg) +/- 3 * Pressure Detection Capacitive Pressure sensor * Inflation Manual Automatic Pressure Application by pump
Manual Deflation and rapid Air Release Manual Automatic Pressure Release Valve
Manual Cuff Range Large (32-45)cm Large (32-45)cm Dimensions of the Equipment (mmXmm) 185 x 162 x 180 * Dimensions of the Display screen (mmXmm) 160 x 160 * Operating Temperature range 0 to 55 degree Celsius * Stroage Temperature range (-10) to 55 degree Celsius * Automatic power off if system is idle for 3 minutes. Yes * Weight (in gram) 915 * Power Power Source: AA size chargeable battery set AA size chargeable battery set
Either Charageble Battery Set Or {220 Volt
50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline
Lithium
Ni- cd WARRANTY
CERTIFICATIONS
TEST REPORTS Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type
from any ILAC/NABL accredited/Central Gov LABFor digital type including Yes * 2/5 Environmental test from any ILAC/NABL accredited/Central Gov LAB Type test report No and date BP-(235)01 26/07/17 * Name and address of the Lab where test Conducted. MSME-TESTING CENTRE
GOVT. OFI NDIA
NEW DELHI SHAHEED CAPT. GAUR MARG
OKHLA
PHASE- III
New Delhi
Delhi 110020 * CE Marking Certificate for B.P. Apparatus Model. Yes * Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time
are applicable to the specification as well as to the product. Yes * Others Certificate ie ROHS
WHO
GMP etc. ROHS
GMP * For Digital Sphygmomanometer
Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes * For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 Yes * 3/5 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the parameters before conditioning After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indrapal Yadav 110033
BJRM Hospital
E- Block
Jahangir Puri 45 15
689067
GEM/2018/B/97549
GeM Contract
blood pressure recording units
GeM Contract
15 days
Delhi; North Delhi
PRODUCT
Awarded to Microline Office Solutions
₹42,300
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Bio Plus Clock Blood Pressure Machine | Bio Plus Clock Blood Pressure Machine | - | 45 NOS | ₹940 | 42,300 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood pressure recording units Blood Pressure Recording Units ( 45 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Aneroid Aneroid Conformity to Indian Standrad for SPHYG MOMANOMETERS IS 7652 latest for Aneroid IS 7652 latest for Aneroid Measuring device Mechnical Mechnical | - | - | - |
| Automated Type Portable Portable | - | - | - |
| Mountable/Fixed | - | - | - |
| Inclined | - | - | - |
| Integrated ISI MARKED Yes Yes | - | - | - |
| NA for digital CM/L No and validity date 8677709 31/10/2017 * Measurement Method Auscultatory method Oscillometric | - | - | - |
| Auscultatory method | - | - | - |
| others Display for Digital BP instrument: NA for others LCD(Liquid Crystal Digital) Display | - | - | - |
| NA for others 1/5 Range: Pressure measurement (mmHg) 0 to 300 * Range:Pulse measurement for digital with accuracy ± 5%. (per minute) 40 to 200 * Accuracy:Pressure measurement (mmHg) +/- 3 * Pressure Detection Capacitive Pressure sensor * Inflation Manual Automatic Pressure Application by pump | - | - | - |
| Manual Deflation and rapid Air Release Manual Automatic Pressure Release Valve | - | - | - |
| Manual Cuff Range Large (32-45)cm Large (32-45)cm Dimensions of the Equipment (mmXmm) 185 x 162 x 180 * Dimensions of the Display screen (mmXmm) 160 x 160 * Operating Temperature range 0 to 55 degree Celsius * Stroage Temperature range (-10) to 55 degree Celsius * Automatic power off if system is idle for 3 minutes. Yes * Weight (in gram) 915 * Power Power Source: AA size chargeable battery set AA size chargeable battery set | - | - | - |
| Either Charageble Battery Set Or {220 Volt | - | - | - |
| 50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline | - | - | - |
| Lithium | - | - | - |
| Ni- cd WARRANTY | - | - | - |
| CERTIFICATIONS | - | - | - |
| TEST REPORTS Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type | - | - | - |
| from any ILAC/NABL accredited/Central Gov LABFor digital type including Yes * 2/5 Environmental test from any ILAC/NABL accredited/Central Gov LAB Type test report No and date BP-(235)01 26/07/17 * Name and address of the Lab where test Conducted. MSME-TESTING CENTRE | - | - | - |
| GOVT. OFI NDIA | - | - | - |
| NEW DELHI SHAHEED CAPT. GAUR MARG | - | - | - |
| OKHLA | - | - | - |
| PHASE- III | - | - | - |
| New Delhi | - | - | - |
| Delhi 110020 * CE Marking Certificate for B.P. Apparatus Model. Yes * Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time | - | - | - |
| are applicable to the specification as well as to the product. Yes * Others Certificate ie ROHS | - | - | - |
| WHO | - | - | - |
| GMP etc. ROHS | - | - | - |
| GMP * For Digital Sphygmomanometer | - | - | - |
| Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes * For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 Yes * 3/5 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the parameters before conditioning After completion of the above environmental tests sequence | - | - | - |
| with a recovery period of 1 to 2 hrs | - | - | - |
| BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Indrapal Yadav 110033 | - | - | - |
| BJRM Hospital | - | - | - |
| E- Block | - | - | - |
| Jahangir Puri 45 15 | - | - | - |
Exempted
30 Nov 2018
3 Oct 2018
contract_GEMC-511687771070194.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_689067.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .