Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹34.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹40.3 LRejected-Finance | ₹40.3 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹40.9 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹40.9 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹41.3 LRejected-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹41.3 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹41.5 LRejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | ₹41.5 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | L-7 Primewave Communications L5 | Vandan Enterprises L6 | ENJOY L4 | Shree Ayyappa Engineering L3 | cooltech engineering services L1 | M/s. Prakash Engineers Contractors and Suppliers L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, test and commission floor-mounted Tower type split Air Conditioner of capacity 3.0 TR, BEE 5-Star rated, complete with outdoor unit and indoor unit, including copper refrigerant tubing of required length with insulation as per OEM recommendations, outdoor unit stand/support and indoor unit stand, separate condensate drain line laid/discharged to nearest floor trap/gully trap, interconnecting power/control cabling between indoor and outdoor units, all necessary fixing accessories, commissioning checks and performance testing, including taking down carefully the existing unserviceable/old floor-mounted Tower AC (including disconnecting electrical connection, dismantling, lowering and removal) and depositing the same in MES store yard complete all as specified and as directed.
Note: The installation, testing & commissioning shall be carried out only through the OEM/authorised service provider (authorised service centre/agency) and the contractor shall submit authorisation letter and commissioning report duly authenticated by all concered, as directed by Engineer-in-Charge | 31 | Each | 1,29,000 ₹40.0 L | 1,29,900 ₹40.3 L | 1,15,000 ₹35.6 L | 1,25,000 ₹38.8 L | 1,03,800 ₹32.2 L | 1,27,900 ₹39.6 L |
| 2.00 | Supply, install, test and commission MCB, TPN, 32 Amp, 415 Volts, “C” curve, 10 kA breaking capacity, in the existing distribution board, including all necessary connections, tightening, and functional testing, complete all as specified and as directed | 31 | Each | 1,700 ₹52,700 | 1,000 ₹31,000 | 2,100 ₹65,100 | 1,100 ₹34,100 | 1,040 ₹32,240 | 1,200 ₹37,200 |
| 3.00 | Supply and fix in repair modular white cover plate with frame, 4 module size, suitable for existing modular switch assembly, including necessary fixing screws/clips and making good, complete all as specified and as directed | 31 | Each | 300 ₹9,300 | 100 ₹3,100 | 600 ₹18,600 | 300 ₹9,300 | 250 ₹7,750 | 150 ₹4,650 |
| 4.00 | M&L for submain wiring comprising four runs of single core PVC insulated, unsheathed FRLS copper conductor cable, 1100 volts grade, multistranded, 4.0 sqmm (nominal area) conforming to IS: 694 and two runs of single core PVC insulated FRLS copper conductor cable, 1100 volts grade, multistranded, 4.0 sqmm (nominal area) as continuous earth continuity conductor, drawn in and including existing PVC conduit and conduit accessories, concealed in walls/roof/ceiling as applicable, including making necessary connections, testing and commissioning, complete all as specified and as directed.
NOTE:
(i) Each sub main wiring shall run in separate PVC conduit.
(ii) PVC casing-capping shall be provided where concealed wiring is not feasible (i.e. on concrete surface/beam/column/ceiling etc.). The quoted rate shall be deemed to include this provision and no extra payment shall be made on this account.
(iii) Four runs of 4.0 sqmm cable and two runs of 4.0 sqmm cable shall be measured as one unit. | 150 | RM | 600 ₹90,000 | 900 ₹1.4 L | 3,200 ₹4.8 L | 1,144 ₹1.7 L | 950 ₹1.4 L | 179 ₹26,850 |
Tender Value
₹41.8 L
EMD Value
₹83,600
Closing Date
20 Feb 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
SPECIAL REPAIRS / REPLACEMENT OF BER FLOOR MOUNTED ACs AT NAVAL BASE KARWAR
2026_MES_750355_1
8456/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE(SB)KARWAR
₹83,600
Yes
9 Apr 2026
30 Jan 2026
23 Feb 2026
30 Jan 2026
20 Feb 2026
13 Feb 2026
30 Jan 2026 - 5 Feb 2026
Supply, install, test and commission floor-mounted Tower type split Air Conditioner of capacity 3.0 TR, BEE 5-Star rated, complete with outdoor unit and indoor unit, including copper refrigerant tubing of required length with insulation as per OEM recommendations, outdoor unit stand/support and indoor unit stand, separate condensate drain line laid/discharged to nearest floor trap/gully trap, interconnecting power/control cabling between indoor and outdoor units, all necessary fixing accessories, commissioning checks and performance testing, including taking down carefully the existing unserviceable/old floor-mounted Tower AC (including disconnecting electrical connection, dismantling, lowering and removal) and depositing the same in MES store yard complete all as specified and as directed. Note: The installation, testing & commissioning shall be carried out only through the OEM/authorised service provider (authorised service centre/agency) and the contractor shall submit authorisation letter and commissioning report duly authenticated by all concered, as directed by Engineer-in-Charge
Supply, install, test and commission MCB, TPN, 32 Amp, 415 Volts, “C” curve, 10 kA breaking capacity, in the existing distribution board, including all necessary connections, tightening, and functional testing, complete all as specified and as directed
Supply and fix in repair modular white cover plate with frame, 4 module size, suitable for existing modular switch assembly, including necessary fixing screws/clips and making good, complete all as specified and as directed
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
techsummary_840408.pdf
finance_840408.pdf
BOQ Comparative Chart
xlsx
finsummary_840408.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_840408.xls
BOQ • 0.29 MB
Tender8456.pdf
Tender Documents • 0.42 MB
Download all tender documents and submit your bid