Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹37.5 LAdmitted-Finance GOA | NORTH GOA | GOA | 403504 | +4.94% | ₹37.5 L | L1 | Admitted-Finance |
| 2 | L2₹42.9 L+₹5.4 L (14.4%)Admitted-Finance | +20.00% | ₹42.9 L+₹5.4 L (14.4%) | L2 | Admitted-Finance |
Tender Value
₹35.7 L
EMD Value
₹71,419
Closing Date
2 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
O/O EXECUTIVE ENGINEER, DIVN V, BICHOLIM.
Tender for the Work of conversion of 33KV Virdi 2 I/C, 33KV Chowgule O/G, 33KV Banastarim O/G Feeder overhead lines to underground cable passing over proposed New office building for the Division office at Electricity Department, Bicholim.
2026_ED_27892_1
Tender-89/Div-V (2025-26)
Open Tender
Electrical Works
Percentage
180 days
Bicholim
AS PER NIT
2 documents required · 2 mandatory
₹500
₹71,419
24 Apr 2026
20 Feb 2026
4 Mar 2026
21 Feb 2026
2 Mar 2026
23 Feb 2026
Cost of Material
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic "vibro-Press" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested. (120/0.48 * 5 nos)
Wire cut Brick 75Kg/cm2 (=120/0.1)*4
Heavy duty, HDGI Class B pipe of inner diameter 150 mm
River Sand (except in sandy soil) bed of 200mm for cushioning of 33 KV XLPE underground cable, as per technical specifications & as per direction of the Engineer-in-charge.
Cable route marker (400 x 900 x 100mm), as per Department's standard specifications. (every 50 mtr)
Plastic / PVC Warning tape ( for entire route length)
33KV Outdoor 3 x 400 sq.mm, anti-fog, Pre-moulded type or heat shrinkable type end termination kit complete with all accessories, suitable for cable as per technical specifications. The kit shall have total creepage distance of 31mm per KV and protected creepage distance of not more than 50% of the total creepage distance, suitable for heavily polluted atmospheric conditions for connecting to the new outdoor breaker panel complete by qualified jointers.
33KV XLPE 3x 400 sq.mm cable straight joints through Pre-moulded type or heat shrinkable type jointing kit complete with all accessories, of reputed make preferably Rachem jointing kit by qualified jointers. as per technical specifications.
Electrode type earthing material with 40mm, 2.5 mts long G.I pipe alongwith 20 Kgs Salt, 20 Kgs Charcoal and 5 mts of H.D.G.I flat of size 50 x 6 mm for earthing connection including material for brick masonary work
GI Flat 25 x 5mm.
MS Rail pole 90 lb 13mts
Supply & Erection of 33KV Disc Insulator SET (Set of 3)
HDGI steel structure including DP Channels, Support channels, N&B etc, Angles, clamps
SETC of 33KV Stay set Complete with GI stay rod and plate,turn buckle eye bolt stay clamps, 9kg of stay wire for 13 mtr RCC pole, break insulator and 0.5 Kg HDGI nut bolts.
Cost of Erection
Excavation in hard rock including all types of laterite rock where blasting is prohibited D/C Trench size - open trench route length. (1.3D X 1.5W X 120L meters) Considered For 5Run.
Back filling of available excavated earth (excluding rock/stones) in trench, in layers not exceeding 0.2 mts depth, consolidating each deposited layer by ramming and watering lead up to 50 mts. (0.95D X 1.5W X 120L meters) For 5Run
Supply and laying of underground cable protective cover as per specification as given below: The concrete slab shall be machine made using semidry concrete that is batched in a fully autimatic PLC controlled concrete batching plant and cast in a fully automatic "vibro-Press" machine with a high vibration frequency and hyraulic pressure of 40 MT, the size of the slab shall be 480mm x 250mm x 50 mm, (+/- 2mm) and the concrete grade shall be M30 adhering to IS 456:2000 and shall have a minimum crushing strength of 30 N/mm2/(28 days strength) when tested. (120/0.48 * 5 nos)
Heavy duty, HDGI Class B pipe of inner diameter 150 mm
Cable route marker (400 x 900 x 100mm), as per Department's standard specifications. (every 50 mtr)
Supply and Laying of 33KV, 3 Core, 400 Sq.mm. Aluminium Conductor, screened, XLPE insulated Galvanized flat strip armoured, PVC sheathed cable Type A2XFY, FR, conforming to IS: 7098/Part-2 as amended up to date, from the place of manufacturing up to the site location. (5R x 150 Meters - 33KV Virdi 2/ 33KV Chowgule / 33KV Banastarim, Considered 2 no spare)
33KV Outdoor 3 x 400 sq.mm, anti-fog, Pre-moulded type or heat shrinkable type end termination kit complete with all accessories, suitable for cable as per technical specifications. The kit shall have total creepage distance of 31mm per KV and protected creepage distance of not more than 50% of the total creepage distance, suitable for heavily polluted atmospheric conditions for connecting to the new outdoor breaker panel complete by qualified jointers.
33KV XLPE 3x 400 sq.mm cable straight joints through Pre-moulded type or heat shrinkable type jointing kit complete with all accessories, of reputed make preferably Rachem jointing kit by qualified jointers. as per technical specifications.
Electrode type earthing material with 40mm, 2.5 mts long G.I pipe alongwith 20 Kgs Salt, 20 Kgs Charcoal and 5 mts of H.D.G.I flat of size 50 x 6 mm for earthing connection including material for brick masonary work
GI Flat 25 x 5mm.
MS Rail pole 90 lb 13mts
Removing & Restringing of ACSR Raccon Conductors
Supply & Erection of 33KV Disc Insulator SET (Set of 3)
HDGI steel structure including DP Channels, Support channels, N&B etc, Angles, clamps
SETC of 33KV Stay set Complete with GI stay rod and plate,turn buckle eye bolt stay clamps, 9kg of stay wire for 13 mtr RCC pole, break insulator and 0.5 Kg HDGI nut bolts.
Removing of ACSR Raccon Conductors
Removing of 13 Mtr Rail poles 90 lb
Removing of MS structure
Removing of 33KV Disc Insulator (Set of 3)
Removing of 33KV Pin Insulators
Removing of 33KV V Shape channel
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggregate. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:All works upto plinth level
Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG made only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone aggregate 20mm nominal size) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for : A)Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
Centering & shuttering including Strutting, Propping & removal of forms for : B)Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, bressumers and Lintels plinth beams not exceeding 1m in depth
Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint.In tees, angles, flats and channels
12mm cement plaster 1:4 (1 cement : 4 fine sand)
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
TRANSPORTATION AND CARRIAGE OF MATERIALS (A) By tipper truck including loading, unloading and stacking (iv ) Excavated rock (upto 5km)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 23.05 MB
BOQ_28338.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .