OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
Creation of 100 KVA Substation along with Its HTLT network at new syed Abad coloney B Syedpora Eidgah Srinagar
2022_PDD_156169_1
EDIV/72 OF 2021-22
Open Tender
Electrical and Maintenance Works
Turn-key
14 days
SYEDPORA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
EXECUTIVE ENGINEER EDIV KHANYAR
₹13,040
Yes
15 Feb 2022
6 Jan 2022
7 Feb 2022
6 Jan 2022
5 Feb 2022
6 Jan 2022
6 Jan 2022 - 6 Jan 2022
Supply, installation, testing and commissioning of:
11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, ( Al wound 100 kVA , and with LV Cable Box having detachable Aluminium Gland plate approved by the Department including earthing of Transformer along with fixing of flat iron strip to be fixed on earthling insulating boots of Sub Stations on two poles structure as per REC Standard F1,F2, F3 F4 &F10 (SITC) conditional Kindly read condtion No 11 of the SBD
11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, ( ALwound 100 kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate approved by the Department including earthing of Transformer along with fixing of flat iron strip to be fixed on earthling insulating boots of Sub Stations on two poles structure as per REC Standard F1,F2, F3 F4 &F10 ( Transformer to be provided by the department which is tobe lifted from Diviisonal stores Khanyar) conditional Kindly read condtion No 11 of the SBD
9 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard (SITC) conditional Kindly read condtion No 11 of the SBD
9 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard ( poles be provided by the department which is to be lifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
GI Channel 100x50x50x6 mm 9' long (2 No) duly fabricated as per site requirement & as per REC Standard .
GI Channel cross-arm (ISLC 75 designation) 75x40x40x6 mm 9' long (8No) duly fabricated as per site requirement & as per REC Standard .
GI Channel cross-arm (ISLC 75 designation) 75x40x40x6 mm 6' long (2 No) duly fabricated as per site requirement & as per REC Standard .
MS Angle iron braces (ISA 5050 designation) 50x50x6mm 6' long (6 No) duly fabricated as per site requirement& as per REC Standard .
Providing of Chemical Earthing of Sub-Station for neutral earthing 2 mtr long 50mm dia GI to copper with additional 1 length GI pipe 38mm connected with chemical earthing and with extension of GI strip 25*3mm upto all equipments.Earthing has been laid through insulators to avoid with the existing structure for LA.
Galvanized Nuts & Bolts & washers of sorts. (Galavinsied as per IS-2633/1986)
185 mm² PVC single core LT cable connforming to IS 1554 (part -I) 1988 for incoming and outgoing circuits to be connected with LT Network including thimbling with 185 mm sq Al lugs
Bi matellic Clamps19mm².
11KV 400 AMP Gang Operated switch gear
Drop-out set (Horn-gap type) as per REC standard F6
11KV Lighting Arrester Set (Station type) as per REC standard conforming to IS 3070 part -III and as per REC standard
LT Distribution Box for 100 kVA with MCCB for incomer & SFU's for outgoing Circuits
11KV pinwith insulators Brown glazed porcelain insulator confirming to IS-731/1971 Amendments 1 to 5 type B with 320mm minimum creepage distance and with lead/Zinc thimbles suitable for use with G.I forged pin having small steel heads as per IS-4l86 (P.I) 1993 and IS-2486 (P.II)1989 and revision with latest amendments if any as per REC Standard C-1
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Earthing Rods as per REC Standard (J-1) (Spiral Type)
Earthing insulating boots
Providing, Erection, testing & commissioning of MS Angle iron for Transformer Belt (ISA 5050 designation) 50x50x6mm 10' long duly fabricated as per site requirement and painted with two coats of Red oxide and Al. Paint as per REC Standard
GI wire for Anticlimbing Device as per REC Standard
Sign Board
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.50 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 9 mtrs Long ST Poles (410, SP-33) (the leftover pit after concreting to be filled with soil and boulders)
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply, installation, testing and commissioning of:
9 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard (SITC) conditional Kindly read condtion No 11 of the SBD
9 mts steel tubular pole post 410 (SP-33) IS 2713 (part-II) 1990 as per REC Standard ( poles be provided by the department which is to be lifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
GI Channel cross-arm 75x40x40x6 mm 9' long (1No) duly fabricated as per site requirement & as per REC Standard .
GI Angle iron braces 50x50x6mm 6' long (3No) duly fabricated as per site requirement and as per REC Standard
Galvanized Nuts & Bolts & washers of sorts. (Galavinsied as per IS-2633/1986)
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language
Earthing Rods as per REC Standard (J-1) (Spiral Type)
500 mm ²ACSR as per REC Standard. Conductor(Rabbit) IS 4826/1979 and laid as per REC standard (SITC) conditional Kindly read condtion No 11 of the SBD
50 mm ²ACSR as per REC Standard. Conductor(Rabbit) IS 4826/1979 and laid as per REC standard ( Conductor be provided by the department which is to be lifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
Pole clamps fabricated out of MS channel
Cement bottoming 1:2:4 mix as per REC standards 0.50 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 13/11/9 mtrs Long ST Poles (410, SP-33) (the leftover pit after concreting to be filled with soil and boulders)
painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply, installation, testing and commissioning of:
8 Mtr. Long ST Poles (410 SP15) with pit excavation conditional Kindly read condtion No 11 of the SBD
8 Mtr. Long ST Poles (410 SP15) with pit excavation ( poles be provided by the department which is to be lifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
50 mm ²ACSR as per REC Standard. Conductor(Rabbit) IS 4826/1979 and laid as per REC standard (SITC) conditional Kindly read condtion No 11 of the SBD
50 mm ²ACSR as per REC Standard. Conductor(Rabbit ) IS 4826/1979 and laid as per REC standard ( Conductor be provided by the department which is to be lifted from Diviisonal stores Khanyar (ITC only) conditional Kindly read condtion No 11 of the SBD
Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1700mm for 8 mtrs Long ST Poles (410, SP-15) (the leftover pit after concreting to be filled with soil and boulders)
pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each pole including supply and welding of GI channel 70x40x150 on pole for earth connection
Galvanized Nuts and Bolts of sizes.
painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
LT Shackle insulators as per REC standard
MukKI Clamps fibricated out of 50x8 mm flat iron of appropiate size and specification for holding LT Shackle insulators.
S. K. Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .