Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹11.6 L+₹1.7 L (16.8%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹12.0 L+₹2.0 L (20.3%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹12.4 L+₹2.4 L (24.2%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹14.4 L+₹4.4 L (44.1%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹24,400
Closing Date
25 Mar 2021, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
AUGMENTATION OF ELECTRICAL SUPPLY AND CIVIL WORKS TO BLDG NO P1 AT CEPTAM AND PROVN OF MINOR WORKS AT CAIR BANGALORE
2021_MES_420802_1
GE(I) R ND D (WEST)/BAN/69 OF 2020-21 8867E8
Open Tender
Civil Works
Item Rate
180 days
Bengaluru
Class and category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹24,400
Yes
27 Mar 2021
16 Feb 2021
26 Mar 2021
17 Feb 2021
25 Mar 2021
6 Mar 2021
17 Feb 2021 - 5 Mar 2021
Amount
Providing anti-static flooring complete all as specified here-in-below :- a) Surface preparation of existing flooring, with proper diamond grinding/ shot blasting to remove dust, laitance, other contaminants etc., and to form the required anchor profile on the floor substrate, inspecting the surface for any cracks. Cracks if any shall be sealed with epoxy repair mortar. b) Installation of Electrode based electrostatically conductive epoxy flooring system in the following sequence :- (i) Over the surface, an epoxy resin based primer Sikafloor 161 HC (or techno commercial equivalent specified here-in-after) shall be applied having 100% solid content, compressive strength 60 N/ sqmm as per EN 196-1, Tensile flexural strength 30 N/ sqmm as per EN 196-1, bond strength 1.5 N/sqmm (failure in concrete) (ISO 4624), shore D hardness 76 as per DIN 53505. (ii) The earthing kit (Electrode) with copper tape shall be placed according to the specification mentioned. The name of the earthing kit would be Sika floor leitset and the copper tape would be Sika Kupferleitband. (iii) Over the primed surface, a conductive undercoat of Sikafloor 220W conductive water borne epoxy having solid content approx. 44% by weight and resistance to earth Rg 10 to 10Ohm as per IEC 61340-4-1 should be applied.
Sl Item No 1 Contd., (iv) Application of conductive epoxy top coat of 2mm with good chemical and mechanical resistance Sikafloor 262 ASN having resistance to earth Rg<10 ohm as per IEC 61340-4-1; (EN1081), compressive strength 80 N/sqmm as per EN 196-1, Flexural strength 40 N/sqmm as per EN 196-1, Bond strength 1.5 N/ sqmm (failure in concrete) as per ISO 4624, shore D hardness 77 as per DIN 53505, Abrasion resistance 100mg (CS 10/100/1000) as per DIN 53109 (Taber abraded test) including taking the conductivity measurements of top coat as per the technical specification. (v) After installation, resistance to earth test shall be conducted as per IEC 61340-4-1 standard. Note:- The quoted rate shall deemed to be inclusive of the following:- (i) Providing and Connecting the copper tape grid to earthing. (ii) The work shall be got executed by an authorized applicator of the manufacturer. (iii) Total requisite quantities of all materials as per manufacturer’s instructions shall be brought to site alongwith original paid vouchers before commencement of the work. Make:- SIKA as specified above or techno-commercially equivalent in FOSROC / BOUCHEMIE
Cutting opening in cement concrete walls without reinforcement (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc, complete all as specified and as directed.
Taking down existing false ceiling (Grid with board), providing Material and labour for aluminium snap grid frame work of size 605 x 605 mm, framework suspended with Hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long, including fixing 8 mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre in 600 mm x 600mm grid, complete all as per manufacturers instructions, complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and disposing of debris outside MD land complete all as specified and as directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) area of opening exceeding 1.5 sq m and not exceeding 4 sq m each, complete all as specified and as directed.
Material and labour, for reinforced cement concrete (1:2:4), type B1 using 20 mm graded stone aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. Note : Formwork and Reinforcement bars will be measured and paid under respective items.
Use and waste formwork to rough finished flat concrete surfaces sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc. complete all as specified and directed.
Material and labour for, Mild steel TMT bars 10mm dia and over, as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Material and labour for, Mild steel TMT bars 5 mm dia over up to 10 mm dia, as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Material and labour for 98 mm thick, metal framed, non load bearing partition with two layers of 12 mm thick calcium silicate boards on either sides of GI frame work, including 50 mm thick insulation (mineral wood) fixed in studs @ 610 mm c/c (48 mm x 34 mm x 36 mm) with screws 25 to 35 mm ling self drilling with under head cutter all as specified and as directed.
Supply and fix powder Coated aluminium frames and shutters (minimum thickness of powder coating 50 microns) and fabricating for doors, windows, ventilators and fixed partitions with one (or) more rebates including necessary joining cleat, glazing clips, rubber packing, snap bending crews etc complete all as specified and as directed. Note :- i) For payment purpose weight of aluminium section shall be measured and paid, ii) Cost of aluminium mongery. lock, rubber packing, rollers for sliding shall be deemed to include in the quoted rate, iii) Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Supply and fix Plain Sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square, exceeding 0.5 sq. m in each pane all as specified and as directed.
Supply and fix powder Coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified complete all as specified and as directed. Note :- Sheet glass and wire gauge shall be measured and paid for separately under respective items.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of plastic emulsion paint over a coat primer, complete all as specified and directed.
Material and labour for concealed Point wiring with PVC insulated unsheathed, multi stranded copper conductor FRLS cable of size 1.5 sq.mm, 1100 grade, with PVC insulated unsheathed multi stranded copper conductor cable of size 1.5 sq.mm for earth continuity wire, drawn into and including non metallic rigid PVC conduit of suitable size, medium grade ISI marked including metal flush boxes of suitable size, modular white cover plate and holding plate for mounting switches/ sockets etc fixed on walls/ roof surface concealed in walls including all necessary chases cutting to wall and making good disturbed surface complete all as specified and directed for One light / fan point / socket point controlled by one, one way switch 5/6 Amps complete all as specified and as directed. Note : i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement and making the disturbed surfaces to match with the existing. ii) Cutting and chases in brick / block masonry for concealed wiring, including making good the disturbed surfaces matching with adjacent shall deemed to be included in the quoted rate.
Material and labour for concealed Point wiring with PVC insulated unsheathed, multi stranded copper conductor FRLS cable of size 4 sq.mm, 1100 grade, with PVC insulated unsheathed multi stranded copper conductor cable of size 4 sq.mm for earth continuity wire, drawn into and including non metallic rigid PVC conduit of suitable size, medium grade ISI marked including metal flush boxes of suitable size, modular white cover plate and holding plate for mounting switches/ sockets etc fixed on walls/ roof surface concealed in walls including all necessary chases cutting to wall and making good disturbed surface complete all as specified and directed for socket outlet 20 Amps on independent board complete all as specified and as directed. Note : i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement and making the disturbed surfaces to match with the existing. ii) Cutting and chases in brick / block masonry for concealed wiring, including making good the disturbed surfaces matching with adjacent shall deemed to be included in the quoted rate.
Supply and fix, exhaust fan 230/240 Volt, 50 Hz, single phase, AC supply, 300 mm sweep, 900 rpm, with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan, including making hole in wall for fixing exhaust fan and making good the disturbed surfaces of wall matching with adjacent surfaces, including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Model : Turbo Force SP of Havells or techno-commercially equivalent model in Almonard / Bajaj.
Supply and fix, MCB DB SPN 4 way (Horizontal), double door, with Sheet metal enclosure, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc including 'C' Curve MCBs working on 230 V, 50 Hz AC, 10 kA, MCB SPN 40 Amps - 1 No & MCB SP 6-10 Amps - 2 Nos, complete all as specified and as directed. Notes : All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs.
Supply and fix, MCB DB TPN 8 way (Horizontal), double door, with Sheet metal enclosure, flush mounted, prewired, 415 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc including 'C' Curve MCBs working on 440 V, 50 Hz AC, 10 kA, MCB TPN 63 Amps - 1 No & MCB, SP 20 Amps - 26 Nos, complete all as specified and as directed. Notes : All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs.
Supply and fix Modular Switch, One module, One way, 5/6 Amps, 240 Volts all as specified and as directed.
Supply and fix Modular Switch, One module, One way, 20 Amps, 240 Volts all as specified and as directed.
Supply and fix, Modular socket outlet, 5/6 Amps 5 pin, 240 V, 2 Module, complete all as specified and directed.
Supply and fix, Modular socket outlet, 20 Amps, 240 V, 2 Module, complete all as specified and directed.
Supply and fix, PVC Ceiling rose, surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix, sheet metal enclosure, TPN, 63 Amps, with MCB TP 63 Amps ('C' Curve, 415 Volts AC, 50 Hz, 10 kA, breaking capacity), with a three pin, earth plug and socket, complete all as specified.
Supply and fixing, Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, stranded copper conductor cable, 4 runs of single core of size 10 Sq mm and one run of earth continuity conductor of size 2 runs of 6 Sq mm to be drawn through and including 25 mm dia PVC conduit medium Grade fixed concealed in walls / roof / floors complete all as specified and as directed. NOTE: - i) Four runs of 10 sq.mm cable, two run of 6 sq mm earth wire and one run of PVC conduit shall be measured as one length. ii) Cost of Cutting and chases in wall for concealed wiring shall deemed to be included in quoted rate.
Supply and fixing, Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, stranded copper conductor cable, 4 runs of single core of size 10 Sq mm and one run of earth continuity conductor of size 1 run of 10 Sq mm to be drawn through and including 25 mm dia PVC conduit medium Grade fixed concealed in walls / roof / floors complete all as specified and as directed. NOTE: - i) Four runs of 10 sq.mm cable, one run of 10 sq mm earth wire and one run of PVC conduit shall be measured as one length. ii) Cost of Cutting and chases in wall for concealed wiring shall deemed to be included in quoted rate.
Supply and fixing, Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, stranded copper conductor cable, 2 runs of single core of size 4 Sq mm and one run of earth continuity conductor of size 1 run of 4 Sq mm to be drawn through and including 20 mm dia PVC conduit medium Grade fixed concealed in walls / roof / floors complete all as specified and as directed. NOTE: - i) Two runs of 4 sq.mm cable, one run of 4 sq mm earth wire and one run of PVC conduit shall be measured as one length. ii) Cost of Cutting and chases in wall for concealed wiring shall deemed to be included in quoted rate.
Supply and fix, 24 W, LED, down lighter fitting, efficient luminaire, 2'x2', Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for ceiling, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.VENUSNEOHE2X2PLR18-42WLED830MOD of Havells or techno-commercially equivalent model specified here-in-after, complete with all accessories pre-wired, all as specified and as directed.,
Supply and fixing high wall Split type Air conditioner of 1.5 Ton capacity, BEE 5 star rating, inverter, with built in air ionizer and plasma filter for better air quality complete with indoor unit & outdoor unit, cordless remote control unit complete with condensing unit, room unit suitable for operation of refrigeration gas including, refrigeration copper piping of required length as per manufacturers instructions, standard length of 7.5 m with Nitrolite Brutile sleeve insulation along with PVC water drain pipe of 25 mm dia of 5 m long, and connecting with and including 4 core 2.5 Sq mm flexible wire etc., all as specified and as directed. Notes :- (i) The condensing unit shall be mounted on the roof slab / side wall / on the ground including making hole in the wall /slab / ground as necessary all as specified. (ii) Room unit shall be placed in the room against the outdoor unit. (iii) Proper drainage arrangement shall be made from room unit to facilitate easy flowing of water outside the room.
Chemical earthing for machinery / equipment complete with using copper hollow electrode of 76 mm dia pipe, 0.254 cm thick, 3 m long with internal copper strip of size 50 mm x 6 mm, burried directly in ground vertically using hand boring for excavation of 100 dia hole in hard/dense soil up to a depth not less than 3.15 m below ground level and inserting electrode and connected to external copper strip by means of copper nuts, bolts, check nuts, washers etc. of copper, excavation and earthwork, Plain cement concrete chamber using 1:3:6 type C1 (using 20 mm graded stone aggregate), 40 mm thick RCC cover slab (1:2:4), reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) Electrode shall be maintenance free copper bounder, copper bounded, copper bounded strip shall be placed centrally inside the electrode, ii) Space inside the electrode should be tightly filled with crystalline conductive mixture containing natural elements and compounds, iii) Structural Specification :- a) Electrode Diameter - 76 mm b) Electrode Length - 3000 mm c) Thickness - 0.254 mm d) Internal Copper Strip Size - 50 mm x 6 mm, e) Connection terminal Die - 14 mm x 02 mm
Sl Item No 31 Contd., f) Material of Construction - Copper bonded (Copper purity not less than 99.9%) g) Copper Bonding - 120 - 150 micron h) Compound filled - Crystalline mixture, i) Quantity of minimum backfill earthing compound - 40 Kg iv) Technical Specifications :- a) Conductive concrete must be environmentally neutral b) It must set up in situ to form a solid and must not leach, dissolve or migrate into soil or water, c) May installed dry or mixed with water to form slurry for horizontal or vertical applications, d) The material must be maintenance free and not require recharging of any kind i.e., watering, chemical or salts, e) The material must have a dry resistivity of less than 10 Ohm-cm and an ability to reduce corrosion by at least 80%, f) The IR value must be less than 1 Ohm
Supply and fixing Voltage stabilizer, for automatic operation, single phase, naturally air cooled indoor type, designed for input between 170 Volts to 250 Volts with output voltage stabilized at 230 volts with accuracy of ± 2.5 % and of capacity 5 KVA for Air conditioners.
Supply and fix sheet metal enclosure, SP with metal plug and socket, 20 Amps, 250 Volts, including provision of one MCB SP 20 Amps complete all as specified and as directed.
Supply and lay cable XLPE insulated armoured LT cable 1100 volts grade of size 70 Sq mm 3.5 core, in trenches/ on walls / poles including suitable MS clamps for fixing if required, connecting, testing and commissioning, complete all as specified and as directed
Supply and lay, copper earth strip of size 20 mm x 3.15 mm continuity or main earthing lead fixed to Wall/ trenches /ducts through Galvanized iron pipe including necessary clamps, nuts, bolts, etc., and connecting up complete all as specified and as directed.
ARUNOTHAYA TRADERS
Solar Electricals and Electronics
Meghana and Gowda Enterprises
Pacific Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .