Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | ₹29.1 L Quoted ₹29.5 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹30.0 L+₹49,439 (1.68%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹30.0 L+₹49,439 (1.68%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹32.4 L+₹2.9 L (9.78%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹32.4 L+₹2.9 L (9.78%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹43.8 L+₹14.4 L (48.7%)Rejected-Finance | ₹43.8 L+₹14.4 L (48.7%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹45.5 L+₹16.0 L (54.1%)Rejected-Finance | ₹45.5 L+₹16.0 L (54.1%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
6 Dec 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO INTERNAL ELECTRIFICATION FITTINGS FIXTURE REPAIR REPLACEMENT OF SUB MAIN WIRING MAIN DBs ENERGY METER UNSV MCBs BLDG EARTHING OTHER MISC E M WORKS IN OTM AT 6TH CAMP 7TH CAMP ETI 16 TETTRA SCHOOL LOGISTICS CTI ECHS OF AFS JAL
2023_MES_625627_1
8842/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹70,000
15 Dec 2023
9 Nov 2023
8 Dec 2023
9 Nov 2023
6 Dec 2023
22 Nov 2023
9 Nov 2023 - 15 Nov 2023
Amount
Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhaust fan, geyser, capacitor, replacement of fuse wires and all electrical accessories in day to day/door to door maintenance including reconnection with Supply and fixing small pieces of electrical cable of size up to 10 sqmm single core and length not exceeding 0.50m complete all as specified and as directed. Note : Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only. Cost of labour for replacement will be deemed to include in the unit quoted rate.
Note for item No 1 :- (a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(b) All bldg. light complaints including service connection, sub main & internal electric for OTM accn of 16 tettra school, ETI,logistic section , ECHS, signal section and officer married Accn in east area of AF stn Jalahalli east shall be attended.
(c) Record of complaints/complaint slip showing qtr No, bldgs. No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) All sort of petty T&P items such as PVC insulation tape, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(e) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(f) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(g) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor, Havells, L&T
Supply only switch piano flush type 5 Amps 240 volts single pole two way. Make : Anchor, Havells, L&T
All as per item No 9 here-in-before but 15 Amp Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 3 pin 5 amps, flush type Make : Anchor, Havells, L&T
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps Make : Anchor, Havells, L&T
Supply only switch socket combination out let 3 pin 5 amps, flush type. Make : Anchor, Havells, L&T
Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type.Make : Anchor, Havells, L&T
Supply only for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked,
Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt. Make : Havells / Anchor/ crabtree
Supply only PVC gang box 1 way 05 amp . Make. Cona/L&T/Anchor
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Indoasian/ Havells.
Supply only metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Legrand/ Havells/ Indoasian
Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only 7 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
Supply only 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only plug top 3 pin 15 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only plug top 3 pin 5 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only bakelite sheet not less than 3 mm thick of suitable size complete all as specified and as directed.
Supply only TPN, MCB 20 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Indoasian/Schneider/ L&T/Havells.
Supply only electronic fan regulator modular typre 230 volts, step type socket type, hum free 100/240 watt Make : Havells / Anchor/ Crabtree.
Supply only insulation tape 25 mm width 10m long
Supply only electronic LED driver 46/47W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ Crompton/ Bajaj as directed by Engineer-in-Charge.
Supply only 4' 20W/ 18W LED Retro bar tube rod suitable for existing fitting. Make : Philips, Bajaj, Havells,Crompton
Supply only bell push Make : Anchor/ Cona/ Havells
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 sqmm 3 core complete all as specified and directed. Make : Havells/ Polycab/ Plaza
Supply only 4 mfd condenser for exhaust fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron)/ Anchor (Penta)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular Socket, 16A - 3/5 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only T-5 tube rod 28 watt
Supply only T-5 tube rod 14 watt
Supply only modular white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular white cover plate with frame,4 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular white cover plate with frame,6 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular white cover plate with frame,08 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular white cover plate with frame,12 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply only modular switch 1 way 32 amp.2 module Make : Legrand (Model- Arteor), ABB (Cheiron),Anchor (Penta)
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Avon plast/ supreme/ Diplast
Supply only rigid, non-metalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Avon plast/ Supreme/ Diplast
Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box
Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box
Supply only SPN MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Indoasian/ Havells/ Legrand.
Supply only PVC Casing & Capping of 15 mm (width) complete all as specified and directed.
Supply only PVC Casing & Capping of 20 mm (width) complete all as specified and directed.
Supply only PVC Casing & Capping of 25 mm (width) complete all as specified and directed.
Supply only TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Indoasian/ Havells/ Legrand.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only 10 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
Material and labour for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and fixing building security/ LED street light fitting 35 Watt, 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete with IP 65/66 protection complete.
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make Philips/Bajaj / Wipro/ Crompton.
Note for item No 64 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Supply and fixing in repairs Electronic energy meter single Phase 5 to 30Amps range capacity complete all as specified. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter shall be deposited to E/M store yard.
Supply and fixing replacement of convectional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting distribution & IP 65 protection including fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make : CG Cat No. LPTO-40-CDL/Bajaj Cat Part No. BRIL 45 W LED NW or equivalent in philips.
Material and labour for wiring for circuit complete sub main wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply & fix the Square LED down lighter 15 /18 watt fit at surface/Ceiling complete all as specified and directed and including taking down old fitting.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply & fix in repair decorative recessed mounted ultra slim square profile 1X1 feet 20 W LED lighting fixture Squre shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 20 Watt and including considering material & labour for fixing ceiling height up to 15 Mtr, all as per site requirement and directed by Engr-in-Charge .
Supply and fixing in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Indoasian/ L&T/ Havells
S & F in replacement 18 watt recess mounted sleek square down lighter environment friendly, new generation, energy saving with high power LED as light sources & clear glass including accessories all as specified and directed by Engr-in-Charge. Make /Model : Philips cat part No.DN 295B LED16S-6500 PSU WH/Wipro/ Bajaj. Note : 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing in repairs Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB. Note :- Old unserviceable meter shall be deposited to E/M store yard.
Supply, installation, testing and commissioning of factory made meter panel board wall mounted made out of CRCA sheet of 2mm thick indoor type totally enclosed weather proof, dust vermin proof with front open able, hinged door locking arrangement mounted on MS clamp welded to panel body duly grouted in wall including provn of Acriylic sheet for meter reading, space for refixing of single phase KWH meter 5-60 Amps -12 Nos AC 230 Volts incl lugs, spacer mounting chanels, rubber gasket, locking knobs, PVC shrinkable sleeves, nut bolts, washers etc, suitable compartment of every meter and control MCB circuit and epoxy powder coated spray paint with primer, CPRI type tested complete all as directed including the following accessories:- Incoming (a) MCCB adjustable 63 amps 04 pole ,415 Volts, 16 KA - 01 No (b) R-Y-B phase LED indicating lamp-03 Nos (c) Copper wiring in panel of suitable size (d) 100 Amps TPN copper busbar Out going (e) MCB 32 amps SPN, 230 Volts, 10 KA - 8 Nos (f) MCB SPN 10Amps ,230Volts, 10KA-01 No (g) Taking down and Re-fixing existing electric meter - 8 Nos (Note: Taking down electric meter and keep safe custody and refixing to same and to be insured properly marching the qtr Nos before fixing the electric meter) all as directed by E-in-Charge.
Supply and fix LED lights fitting 1 x 20 W, 4' long, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old/unsv fittings all as specified and directed by Engr-in-charge.
Supply and fixing in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Legrand/Indoasian/ Standard
Supply and fixing in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Havells/ L&T/ Indoasian
Supply and fix LED spot light focus light fitting 9W,surface mounted,tiltable type AC 230 volts complete all as specified and directed.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid separately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Material and labour in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through surface PVC conduit/ existing concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately).
One light point/fan/bell point controlled by one switch
All as per item No. 81 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 81 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 81 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Material and labour in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn PVC through Casing Capping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately.
One light point/fan/bell point controlled by one switch
All as per item No. 86 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 87 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 87 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fixing in repairs pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 2 Prismatic of Havells Cat Part No : LHDC12115099 or equivalent in Wipro or CG.
Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Casing Capping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittings, fans, bells & regulators will be measured and paid for separately).
One light point/fan/bell point controlled by one switch
All as per item No. 93 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 93 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 93 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Material and labour in repairs for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl surface PVC Conduit/ existing concealed conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separately).
One light point/fan/bell point controlled by one switch
All as per item No. 98 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 98 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 98 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor, Havells, L&T
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor, Havells, L&T
Supply and Fix shuttered socket outlet 3 pin 5 amps, flush type Make : Anchor, Havells, L&T
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps Make : Anchor, Havells, L&T
Supply and Fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply and Fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Anchor (Penta)
Supply and fixing Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexiable copper conductor cable of suitable size including taking down old light fitting. Make : Bajaj Cat No 112405BCLSB 05 WH or equivalent of Philips /Havells.
Supply and fixing in repairs LED retrofit lamp 9W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specified and directed. Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years
Supply and fixing in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old/unsv fittings all as specified and directed by Engr-in-charge.
(i) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Material and labour for Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electro grip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
(i) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(ii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
Supply, installation, testing and commissioning of factory made meter panel board wall mounted made out of CRCA sheet of 2mm thick indoor type totally enclosed weather proof, dust vermin proof with front open able, hinged door locking arrangement mounted on MS clamp welded to panel body duly grouted in wall including provn of Acriylic sheet for meter reading, space for refixing of single phase KWH meter 5-60 Amps -12 Nos AC 230 Volts incl lugs, spacer mounting channels, rubber gasket, locking knobs, PVC shrinkable sleeves, nut bolts, washers etc, suitable compartment of every meter and control MCB circuit and epoxy powder coated spray paint with primer, CPRI type tested complete all as directed including the following accessories:- Incoming (a) MCCB adjustable100 amps 04 pole ,415 Volts, 16 KA - 01 No (b) R-Y-B phase LED indicating lamp-03 Nos (c) Copper wiring in panel of suitable size (d) 150 Amps TPN copper busbar Out going (d) MCB 32 amps SPN, 230 Volts, 10 KA - 12 Nos (e) MCB SPN 10Amps ,230Volts, 10KA-01 No (f) Taking down and Re-fixing of existing electric meter - 12 Nos (Note: taking down electric meter and keep safe custody and refixing to same and to be insured properly matching the qtr Nos before fixing the electric meter) all as directed by E-in-Charge.
Material and labour Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of conduit : Avon Plast/ Supreme/ Diplast Make of Cable : Plaza/Polycab/Havells Note: 4 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor along with suitable size PVC conduit shall be measured as one length
Supply and fixed in repairs Sheet metal enclosure with distribution board TPN 415 Volts 8 ways Double door with suitable bus bar for provn for MCBs/ Isolators, fixed to wall and making all connections all as directed. Make: Havells/ Indoasian/Legrand
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 10 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 10 sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and fixing in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Indoasian/ Havells/ Legrand.
Supply and fixing road lighting/ building security luminaire of watt 20 watt LED 2000 lumens street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent incrompton/Bajaj. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. Make:- Havells/ Polycab/ Plaza/Indoasian
Material and labour for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and including taking down old fitting
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor for over head service connection suspended by insulating hangers not more than one meter apart including 4 mm dia GI suspension wire complete all as specified .
Supply and fixing in replacement of convectional type bollard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped victoria design with opal acrylic diffuser and IP 65 protection including fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no.LBLSN-10-CDL /Bajaj Cat Part No. BGBOS 600 9W LED /Philips.
Supply and fix LED up to 7.5 W decorative, surface mounted, doom shaped pendant light fitting extendable type AC 230 volts complete all as specified and directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one all as directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
Material and labour Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
(a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Material and labour in repairs Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
M/S SRI BALAJI ENTERPRISES
ARUNOTHAYA TRADERS
eurekaenterprises
Forge Engineering & Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .