Loading…
Loading…
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
15 Jun 2026, 10:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
57 conditions · 7 needing a document upload
The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value and Additional Performance Guarantee as per Clause 16(4)(h) of GCC-2022, in any of the following forms:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii)Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted. New Para 16(4) (h) of Part-II of GCC'22: If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (i) If Bid quoted in % of advertised cost is Below 0 - 5% (inclusive), Additional Performance Guarantee (%) will be 'Nil'. (ii) If Bid quoted in % of advertised cost is Below 5%, Additional Performance Guarantee (%) will be '5%.
Performance Guarantee : The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. However the clause may also applicable as amended time to time.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days.
The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value.
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. The Security Deposit shall, however, be released only after expiry of the maintenance period and after passing the final bill based on No Claim Certificate from the contractor.
Whenever the contract is rescinded, the Security Deposit shall be forfeited and the Performance Guarantee shall be encashed. The balance work shall begot done independently without risk cost of the failed contractor. The failed contractor shall be debarred from participating in the tender for executing the balance work. If the failed contractor is a JV or a Partnership firm,then every member/partner of such a firm shall be debarred from participating in the tender for the balance work in his/her individual capacity or as a partner of any other JV/partnership firm.
In case of Bank Guarantee submitted as a Performance Guarantee then Bank confirms that it is on the SFMS (Structured Financial Messaging System) and shall invariably send the advice of this Bank Guarantee to the following bank details - IFSC CODE - SBIN000RAIL IFSC TYPE - BRANCH BANK NAME - STATE BANK OF INDIA BRANCH NAME - RAIL CITY NAME - NAVI MUMBAI ADDRESS - SECTOR-11, CBD BELAPUR, NAVI MUMBAI DISTRICT - NAVI MUMBAI STATE - MAHARASHTRA BG ENABLED - YES
"Bid Security: (1) (a) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be as under: Value of the Work and Bid Security : For all works, 2% of the estimated cost of the work. Note: (i) The Bid Security shall be rounded off to the nearest 100. This Bid Security shall be applicable for all modes of tendering. (ii) Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. (iii) Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above. (b) It shall be understood that the tender documents have been issued to the tenderer and the tenderer is permitted to tender in consideration of stipulation on his part, that after submitting his tender he will not resile from his offer or modify the terms and conditions thereof in a manner not acceptable to the Engineer. Should the tenderer fail to observe or comply with the said stipulation, the aforesaid amount shall be liable to be forfeited to the Railway. (c) If his tender is accepted, this Bid Security mentioned in sub para (a) above will be retained as part security for the due and faithful fulfillment of the contract in terms of Clause 16 of the Standard General Conditions of Contract. The Bid Security of other Tenderers shall, save as herein before provided, be returned to them, but the Railway shall not be responsible for any loss or depreciation that may happen thereto while in their possession, nor be liable to pay interest thereon.
The Bid Security shall be deposited either in cash through epayment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (Le. excluding the last date of submission of bids) . iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
The Railway reserves the right of not to invite tenders for any of Railway work or works or to invite open or limited tenders and when tenders are called to accept a tender in whole or in part or reject any tender or all tenders without assigning reasons for any such action.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
@ 18% GST has been included in schedule rate, GST will be paid to the firm's at the time of billing, subjected to firm's production of sufficient documentary evidences in support of same. NOTE: % of GST as applicable during the period of execution.
Inspection charges of RITES / Third Party Inspection (TPI) Agencies are to be borne by the contractor where necessary as per extent rule (where the value of purchase order exceeds Rs. 5 lakhs)
The work shall be treated as on work contract basis and the rates tendered shall be for complete items of work (except the materials, if any, stipulated for supply by the department) inclusive of all taxes (including works contract tax,if any duties, and levies etc and all charges for items contingent to the work, such as packing, forwarding, insurance, freight and delivery at site for the materials to the supplied by the contractor, watch and ward of all materials (including those if any supplied by the department) for the work at site etc.)
Unless and otherwise mentioned in the tender documents, the following works shall be done by the contractor, and therefore their cost shall be deemed to be included in their tendered cost- i)Foundations for equipments and components where required, including foundation bolts. ii)Cutting and making good all damages caused during installation and restoring the same to their original finish. iii)Sealing of all floor openings provided by him for pipes and cables, from fire safety point of view, after laying of the same. iv)Painting at site of all exposed metal surfaces of the installation other than pre-painted items like fittings , fans, switchgear/distribution gear items, cubicle switch board etc. Damages to finished surfaces of these items while handling and erection, shall however be rectified to the satisfaction of the Engineer-in-charge. v)Testing and commissioning of complete installation
Unless and otherwise specified, power supply and water supply will be arranged by the contractor at the site for installation purpose. However, for testing purpose, electricity supply will be available free of cost to the contractor. Contractor will take due care to ensure safety of electrical installation during execution of work
The contractor shall co-ordinate with all other agencies involved in the building work is not hampered due to delay in his work. Recessed conduit and other works, which directly affect the progress of building work, should be given priority.
Tools for Handling and Erection All tools and tackles required for handling of equipments and materials at site of work as well as for their assembly and erection and also necessary test instruments shall be the responsibility of the contractor
Care of Buildings: Care shall be taken by the contractor to avoid damage to the building during execution of his part of the work. He shall be responsible for repairing all damages and restoring the same to their original finish at his cost. He shall also remove at his cost all unwanted and waste materials arising out of his work from the site.
Structural Alterations to Buildings: (i) No structural member in the building shall be damaged/altered, without prior approval from the competent authority through the Engineer-in-charge. (ii) Structural provisions like openings, cutouts, if any, provided by the department for the work, shall be used. Where these require modifications, or where fresh provisions are required to be made, such contingent works shall be carried out by the contractor at his cost. (iii) All such openings in floors provided by the Department shall be closed by the contractor after installing the cables/ conduits/ rising mains etc. as the case may be, by any suitable means as approved by the Engineer-in-charge without any extra payment. (iv) All chases required in connection with the electrical works shall be provided and filled by the contractor at his own cost to the original architectural finish of the buildings
Addition to an Installation: Any addition temporary or permanent to the existing electrical installation shall not be made without a properly worked out scheme/ design by a qualified Electrical Engineer to ensure that such addition does not lead to overloading, safety violation of the existing system.
Work in Occupied Buildings: (i) When work is executed in occupied buildings, there would be minimum of inconvenience to the occupants. The work shall be programmed in consultation with the Engineer-in-charge and the occupying department. If so required, the work may have to be done even before and after office hours. (ii) The contractor shall be responsible to abide by the regulations or restrictions set in regard to entry into, and movement within the premises. (iii) The contractor shall not tamper with any of the existing installations including their switching operations or connections thereto without specific approval from the Engineer-in-charge.
Conformity to IE Act, IE Rules, and Standards: All Electrical works shall be carried out in accordance with the provisions of Indian Electricity Act, 2003 and Indian Electricity Rules, 1956 amended up to date and As per RDSO specification
Quality of Materials: All materials and equipments supplied by the contractor shall be new. They shall be of such design, size and materials as to satisfactorily function under the rated conditions of operation and to withstand the environmental conditions at site
Inspection of Materials and Equipments: Materials and equipments to be used in the work shall be inspected by the Departmental officers. Such inspection will be of following categories: (i) Inspection of materials/ equipments to be witnessed at the manufacturer's premises in accordance with relevant BIS/ Agreement Inspection Procedure. (ii) To receive materials at site with Manufacturer's Test Certificate(s). (iii) To inspect materials at the Authorized Dealer's Godowns to ensure delivery of genuine materials at site. (iv) To receive materials after physical inspection at site. The Departmental officers will take adequate care to ensure that only tested and genuine materials of proper quality are used in work. Similarly, for fabricated equipments, the contractor will first submit dimensional detailed drawings for approval before fabrication is taken up in the factory. Suitable stage inspection at factory also will be made to ensure proper use of materials, workmanship and quality control. The tender specifications will stipulate the inspection requirements or their waiver for various materials/ equipments including norms of inspection in specific cases
Ratings of Components: All components in a wiring installation shall be of appropriate ratings of voltage, current, and frequency, as required at the respective sections of the electrical installation in which they are used. All conductors, switches and accessories shall be of such size as to be capable of carrying the maximum current, which will normally flow through them, without their respective ratings being exceeded
Conformity to Standards: All components shall conform to relevant Indian Standard Specifications, wherever existing. Materials with ISI certification mark shall be preferred. A broad list of relevant Indian Standards is given in Appendix D. These Indian Standards, including amendments or revisions thereof upto the date of tender acceptance, shall be applicable in the respective contracts
Only quality materials of reputed make as specified in the tender will be used in work.
Testing: All tests, to be done before, during and after installation, shall be carried out, and the test results shall be submitted to the Engineer-in-charge in prescribed Performa, forming part of the Completion Certificate
Commissioning on Completion: After the work is completed, it shall be ensured that the installation is tested and commissioned
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Please read the Explanatory note for detail description of work, their make etc and all other attached documents before submission of Tender.
Any other reputed make/ brand other than as mentioned in the explanatory note may be included during the execution of the works on an urgent basis/as per direction when needed with approval of competent authority.
Electrical work for augmentation of length of 02 nos of lines along with extension of Pit and provision of necessary infrastructure required for examination of length LHB rakes at reception yard at SRC coaching yard.
Elect-Chg-OT-26-27-EXTNPI
Elect-Chg-OT-26-27-EXTNPI
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹1 L
15 Jun 2026
21 May 2026
1 Jun 2026
73 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 49,98,397.97 | ||
| — | 20.00 | — | — | ||
| Electric Pole Cutting (Pole to be deposited in Consignee's Store) | — | — | — | 19,558.8 | |
| — | 20.00 | Each Span | — | ||
| Dismantling of existing LT line including Rail/PSC pole, distribution box etc and the dismantling material is to be deposited at consignee store, span may be 3 or 4 or 5 wire as per site. | — | — | — | 30,245.6 | |
| — | 10.00 | — | — | ||
| Supply of 4M HDG(Hot Dip Galvanized) Octagonal Pole with double arm brackets and 02 quantity LED street light 45watt, IP66 and IK 07 with isi mark, top dia 70mm,bottom dia 130mm,sheet thickness 3mm,base plate dimensions(L X B X T)-200x200x12mmwith foundation bolts and single arm 1000mm long special brackets. The door opening of the pole should be reinforced, water proofed & with locking arrangement & arrangement of in build junction box with DP MCBs 16 A-1 No , , to be placed on a din channel of Pole and supply and fixing of Terminal connector, connection of terminals with lugs, earthing at the suitable location of the pole. | — | — | — | 1,11,980 | |
| — | 10.00 | — | — | ||
| Fixing and Commisioning of 4M HDG(Hot Dip Galvanized) Octagonal Pole ,top dia 70mm,bottom dia 130mm,sheet thickness 3mm,base plate dimensions(L X B X T)- 200mmX200mmX12mm or higher with foundation bolts and single/double arm, 1000mm long special brackets, junction box and with concretting the foundation of size 750mmx750mm at bottom and 500mmX500mm at top or as per site rquirement with height 1500mm in the ratio 1:3:6 ( the rate shall be inclusive of all materials ) with necessary cable arrangement for lighting fixture with double arm brackets including transportation of pole to site location. | — | — | — | 15,901.2 | |
| — | 190.00 | — | — | ||
| Supply of LED light Fitting 22W 48V of standard size along with LED lightconfirming with IP 65 & IK 10 water & dust proof for pit light, make- Goldwin & Pyrotech or similar. By engraving the pit wall. a suitable metallic net to be provided over the light. The light must remain inside the pit wall surface. | — | — | — | 5,22,500 | |
| — | 190.00 | — | — | ||
| Fixing and commissioning of LED pit light fittings 22W 48V of standard size along with LED light confirming with IP 65 & IK 10 water & dust proof for pit light. | — | — | — | 32,913.7 | |
| — | 8.00 | — | — | ||
| Supply, of Rain proof Low voltage step down with copper wound Transformer 2KVA,230 /48 volt , 50 hz, AC with MCB (DP) of 32amps 230 v on incoming side with TPN-1 4 way cable connector of suitable size and 8 x 2A HRC fuse for 8 no outgoing circuit all complete assembly in a sheet metal box with internally embedded gasket. for pit lighting system. | — | — | — | 67,943.76 | |
| — | 8.00 | — | — | ||
| Erection, testing and Commissioning Rain proof Low voltage step down with copper wound Transformer 2KVA,230 /48 volt , 50 hz, AC with MCB (DP) of 32amps 230 v on incoming side with TPN-1 4 way cable connector of suitable size and 8 x 2A HRC fuse for 8 no outgoing circuit all complete assembly in a sheet metal box with internally embedded gasket. for pit lighting system. | — | — | — | 8,307.28 | |
| — | 10.00 | — | — | ||
| Supply, of LED Flood light fittings150W LED, IP-66. | — | — | — | 72,033.9 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning ofLED Street light fittings150 W LED, IP-66. | — | — | — | 2,988.7 | |
| — | 10.00 | — | — | ||
| "Supply of Earthing arrangement with supply of earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes supply and connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes earth clamp of size 50X6mm GI and testing of earth resistance. Make of GI pipe of Medium (B Class) | — | — | — | 13,057.9 | |
| — | 10.00 | — | — | ||
| Erection of Earthing arrangement with commissioning of earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A-3/P-150 including sump box with salt and charcoal,metalic cover etc.Cost also includes connection of 35X3 SWG GI strip between earth pole and main switch/DB/Rail pole etc. as per site supervisor's instruction. Cost also includes connection of earth clamp of size 50X6mm GI and testing of earth resistance. | — | — | — | 6,281.5 | |
| — | 4.00 | — | — | ||
| Transportation of cables in rolls with or without wooden drums from the store of concerned SSEE or any store of SRC to the site of works. | — | — | — | 3,832.2 | |
| — | 3200.00 | — | — | ||
| Concealed/ Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 2.5 sq.mm Cu.cable, 660 Volt grade make- M/s.Polycab,M/s.Finolex, M/s.Havell's,M/s.Anchor through PVC conduit (25 mm dia and 1.5 mm thickness/PVC Casing & Capping of thickness 1.2 mm) make- Kalinga/Presto plast/Precission and continuous earthing by 14 SWG tinned Cu. wire/1 Sq. mm PVC Cu. wire to be provided as and where required as per direction of consignee. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable & 1mtr of 14 SWG tinned Cu. wire/1.5Sq.mm PVC Cu. as earthing with Supply of PVC Circular Box and Ceiling rose with connection 1.5 Sq.mm PVC wire from running circuit ( 2.5 Sq.mm PVC wire) as per direction of Consignee. | — | — | — | 2,09,312 | |
| — | 1500.00 | — | — | ||
| Concealed /Circuit/Sub-circuit wiring by 4 Sq mm PVC wire with 2.5 Sq mm earthing wire of PVC CU wire through 20 mm dia PVC conduit pipe . | — | — | — | 1,83,885 | |
| — | 20.00 | — | — | ||
| Supply of EFT with 2 terminals as per ICF Drg. No. GS-7-5-003 for battery charging. | — | — | — | 7,589.8 | |
| — | 20.00 | — | — | ||
| Erection of EFT with 2 terminals as per ICF Drg. No. GS-7-5-003 for battery charging. | — | — | — | 11,000 | |
| — | 10.00 | — | — | ||
| Supply welding feed terminal DB of capacity 200A current in MS box with 2 welding terminal stud with fly nut etc & 2 Nos. fiuse link of 315A capacity approved by Rly. | — | — | — | 34,000 | |
| — | 10.00 | — | — | ||
| Erection testing & commissioning of welding feed terminal DB of capacity 200A current in MS box with 2 welding terminal stud with fly nut etc & 2 Nos. fuse link of 315A capacity approved by Rly. | — | — | — | 6,300 | |
| — | 20.00 | — | — | ||
| Supply of Three phase industrial metal clad plug and socket 30/32 amps. Tpn with 3 - pole 32 a c curve mcb of 10 ka breaking capacity , mounted in epoxy powder coated sheet steel enclosure, suitable for 440 v, 3 phase, 50 hz supply , confirming to is-8828 / 1996 or latest. | — | — | — | 34,400 | |
| — | 20.00 | — | — | ||
| Fixing & Commissioning of Three phase industrial metal clad plug and socket 30/32 amps. Tpn with 3 - pole 32 a c curve mcb of 10 ka breaking capacity , mounted in epoxy powder coated sheet steel enclosure, suitable for 440 v, 3 phase, 50 hz supply , confirming to is-8828 / 1996 or latest. | — | — | — | 3,440 | |
| — | 2.00 | — | — | ||
| "Supply Fixing and Commissioning of 125 A 3 Phase Precooling station made of Polycarbonate enclosure (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, should withstand glow wire test Glow wire test as per IEC 60695-2-11: 960 °C, should be flame retardant, degree of Protection IP 65, Degree of protection. Dimension of Precooling station 500x1051x425mm fitted with 1 no. Industrial socket & plug must be IP67 insulated 125 A , 5 pin (3P +E+N) made of high quality polyamide P-6 body shock proof ,rust free, corrosion free, acid and chemical resistant, fire retardant having high impact proof, made of halogen and silica free recyclable materialand terminal contact solid high quality turned contacts made of copper alloy(brass). There will be a 125A FP 25 kA MCCB. For avoiding condensation or formation of water droplets inside the welding receptacle,measures must be taken following safety standard IEC 60364-5-52 using Passive Solutions. Mounting Type : Wall Mounting/outdoor Cable Entry : Bottom System Voltage415V, 50Hz, 4Wire+EOutgoing 125A FP 25KA MCCB- 1No 125A 5P IP67 Plug&Socket- 1No. | — | — | — | 1,33,800 | |
| — | 2.00 | — | — | ||
| "Supply and erection of Battery charger for charging battery for AC and TL applications: Supply of Battery charger, 110V DC, 0.5 to 5A in trickle charging, 10A to 30A in boost charging suitable for 110V, 200AH Lead Acid Battery as per RDSO spec. no. ETI/PSI/24(6/81) or latest. | — | — | — | 4,42,000 | |
| — | 1.00 | — | — | ||
| " Supply at Site, erection, testing, installation & Commissioning of distribution box outdoor typeweatherproof industrial type floor/ wall mounted (as per space available at work sight ) Double door panel board comprising of 2x400A FP MCCB 35KA as incoming and 6x250A FP MCCB, 3x100A FP MCCB 35KA as outgoing confirm to IEC 60947-II for MCCBs. All MCCBs are with adjustable thermal and fixed magnetic setting and necessary protection arrangement etc. As require to complete the work in all respect as per direction of electric (G) Supervisor (Rly.) Site Incharge. | — | — | — | 2,42,962 | |
| — | 5.00 | — | — | ||
| Supply fixing and commissioning of of 4 pole copper bus bar of 200A capacity in suitable fibre box. | — | — | — | 39,755 | |
| — | 2.00 | — | — | ||
| "Supply of Analog Time Switches for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/Tower/Wall mounted ,Supply Voltage 240V AC,50/60HZ,with DP 32A power contractor and 32A,10kA DP MCB-01no with SS enclosure with proper wiring to complete job. | — | — | — | 3,238.1 | |
| — | 2.00 | — | — | ||
| Fixng and Commissioning of Analog Time Switches for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/Tower/Wall mounted ,Supply Voltage 240V AC,50/60HZ,with DP 32A power contractor and 32A,10kA DP MCB-01no with SS enclosure with proper wiring to complete job. | — | — | — | 1,069.94 | |
| — | 10.00 | — | — | ||
| Supply of Metal Junction Box flameproff, IP65. 6 way open type, 3 phase.Anti corrosive,High tensile strength,Low maintenance,Rust proof,Ideal for handling high pressure and temperature, suitable for 4 Nos. 3/4" ET Entry. | — | — | — | 22,627.1 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning Metal Junction Box flameproff, IP65. 6 way open type | — | — | — | 1,335 | |
| — | 1000.00 | — | — | ||
| Supply of L.T. Aluminium Armoured LT XLPE cable of size 4 Core x120 Sq mm 1100 Volts Grade. IS No. 7098-Part-1, 1988, with amendment No. 1 and 2 and 3 reaffirmed 2005. | — | — | — | 5,93,220 | |
| — | 1000.00 | — | — | ||
| Supply of L.T. Aluminium Armoured PVC XLPE cable of size 4 Core x35 Sq mm 1100 Volts Grade. IS No. 7098-Part-1, 1988, with amendment No. 1 and 2 and 3 reaffirmed 2005. | — | — | — | 2,37,290 | |
| — | 1000.00 | — | — | ||
| Boring/punching of underground crossing of Railway track/road with pipe pushing by HDD technology & crossing HT/LT power cable below railway track/road through pipe. | — | — | — | 10,00,200 | |
| — | 100.00 | — | — | ||
| Laying of cable / cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 26,441 | |
| — | 100.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 5,345 | |
| — | 800.00 | — | — | ||
| Laying of cable / cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 89,176 | |
| — | — | — | 7,62,467.49 | ||
| — | GST @ 18% | for the Sch A | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
cablespec.pdf
ATTACHMENT
GeneralConditions.pdf
ATTACHMENT
GCC 2022
ATTACHMENT
MANDATEFORM.pdf
ATTACHMENT
CerInfregEmp.Par.ofRet.RailwayEmployees.pdf RAILWAY EMPLOYMENT CERTIFICATE
ATTACHMENT
JPOfordiggnigwork.pdf
ATTACHMENT
ExplanatorynoteStablinglinee.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf GCC correction slip
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
CerInfregEmp.Par.ofRet.RailwayEmployees.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .