| 1 | L-1₹98.2 LAccepted-AOC | ₹98.2 L Quoted ₹1.0 Cr | L-1 | Accepted-AOC Being lowest tenderer |
| 2 | L-2₹1.1 Cr+₹1.5 L (1.45%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹1.1 Cr+₹1.5 L (1.45%) | L-2 | Rejected-Finance Not being lowest tenderer |
| 3 | L-3₹1.1 Cr+₹4.0 L (3.81%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹1.1 Cr+₹4.0 L (3.81%) | L-3 | Rejected-Finance Not being lowest tenderer |
| 4 | L-4₹1.1 Cr+₹4.6 L (4.42%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.1 Cr+₹4.6 L (4.42%) | L-4 | Rejected-Finance Not being lowest tenderer |
| 5 | L-5₹1.1 Cr+₹7.5 L (7.16%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹1.1 Cr+₹7.5 L (7.16%) | L-5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
17 Sept 2024, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
SPECIAL REPAIR/ REPLACEMENT OF HT CABLES WITH CONNECTED ITEMS FROM OLD BASE S/S TO HAZIPEER PUMP S/S, HAZIPEER PUMP HOUSE S/S TO 17 MAHAR S/S AND COD PH TO SHAMSAN GHAT UNDER GE(U) ELECT SUPPLY, DELHI CANTT-10
2024_MES_641195_2
CWE(U)/D-33/2023-24
Open Tender
Civil Works
Item Rate
270 days
HQ CWE (U) DELHI CANTT-10
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE(U) ELECTRIC SUPPLY, DELHI CANTT -110010
₹2.2 L
Yes
13 Dec 2024
5 Sept 2024
24 Sept 2024
5 Sept 2024
17 Sept 2024
12 Sept 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr depth in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed by Engineer- in- Charge. Note :- If during the Excavation of HT Cables existing under ground LT/HT Cables ,Gas Pipe Lines, Water Pipe Lines are damaged by the Contractor or his Rep/Labour, the same shall be repaired by the contractor at his own cost and nothing extra will be admissible on this account.
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick each layer complete all as specified and directed by Engr-in-Charge.
Removing excavated material (i.e. soil) from site to a distance n. exc. 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc., complete all as specified and directed by Engineer-in-Charge. Punned thickness shall measured and punning shall be done by hand; Mechanical punner shall not be allowed.
Supply & laying non-reinforced precast concrete cable cover of grade not lower than M-20 conforming to IS-5820:1970 class HVP type 1 with peak size 300 mm x 180mm x 40mm in trenches for protection to under ground cable complete all as specified and directed by Engineer-in-Charge.
Laying only old bricks/PCC covers as obtained from Ser item No 01 here-in-before complete all as specified and directed by Engineer in charge.
Supplying, laying, jointing testing and connecting XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches/ ducts/encased in GI pipe/fixed to pole, including jointing & testing complete all as specified in IS 1255-1983 including taking out old HT cables complete all as specified and directed by Engineer-in-charge for the following cables:- Note :- Excavation, earth work ,cable protection , sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
185 sqmm 3 core
150 sqmm 3 core
120 sqmm 3 core
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.6 MPa working pressure complete all as specified and directed by Engineer-in-charge
S&F precast cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm dia TMT Bar 150mm c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint including writing for HT cable11KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm including necessary excavation & earthwork for cable route indicator deemed to be included in the item.
Supply, installing, testing and commissioning of factory made and tested HT Panel board, size: 1200 mm x 1200 mm x 900 mm ,cubical compartmentalized , out door type double door, suitable for 11000 Volts, 3 phase, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars of size ,50 mm x 10 mm, 3 Nos installed on SMC insulators suitable for 11000 Volts .The panel shall be dust and vermin proof. IP-65 class protection and shall be made of 3.15 mm CRCA sheet, and 50x 50 x 6mm thick MS angle iron frame work, powder coated front and rear opening type, with apron for cable entry closing locking . The fixing of double doors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc. for panel. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as specified and directed by Engr-in-charge.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm 3 core
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironsides complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed .
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded aggregate) for foundation, filling and mass concrete etc. complete all as specified and directed .
S&F equal Angle iron, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape including preparation of steel surfaces and applying of one coat of primer and two coat synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
S&F 4 mm thick mild steel wire 75 mmx25 mm mesh up into mattresses or cages, lapped wired and fixed in position including welded for fencing to grid including preparation of steel surfaces and applying one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified and directed.
mayur enterprises (BID ID -3096326)
MV Engineers And Contractors (BID ID -3095031)
Commercial Traders (BID ID -3097974)
Ridhi engineers and builders (BID ID -3097992)
Vijay Electricals (BID ID -3097860)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3096730)
M/s VINOD KUMAR SHARMA (BID ID -3098007)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .