Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC M S SODHI TRADING DEWAN BAGH BARAMULLA JAMMU AND KASHMIR 193101 UDYAM JK 03 0006100 01ABYFS3595H1ZM B R | BARAMULLA | JAMMU AND KASHMIR | 193101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.0 L+₹2.2 L (6.41%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.2 L+₹3.4 L (9.82%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Jul 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Certain B/R repairs to water supply installations under GE Utilities Udhampur
2020_MES_351243_2
GE/U-18/2020-21
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹80,000
Yes
11 Sept 2020
19 Jun 2020
15 Jul 2020
19 Jun 2020
13 Jul 2020
29 Jun 2020
Amount
Demolition of brick work or stone /boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
Dismantling timber scantlings 40 sqcm and over in section in any position framed or unframed work etc complete all as specified and directed by Engr-in-Charge.
Dismantling timber scantlings as in fillets, rails, posts rafters, purlins etc in framed/unframed work, not exceeding 40 sqcm in section in any position complete all as specified and directed by Engr-in-Charge.
Dismantling wall and ceiling boards any thickness, including cover fillets etc complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semi corrugated, etc), sheets in in roof covering complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, (Nominal mix), type B-1, 1:2:4 (using 20mm graded crushed stone aggregates) as in cills, coping, apex stone, bed plates and lintel upto 1.6m clear span etc including weathering slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed by Engr-in-Charge.
Reinforced cement concrete, (Nominal mix), type B-1, 1:2:4 (using 20mm graded crushed stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. Note: Reinforcement shall be measured and paid separately.
Separating, scraping and cleanig of reinforcement (demolition of concrete measured seprately) complete all as specified and directed by Engr-in-Charge.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 12.00 here-in-before but except bricks complete all as specified and directed by Engr-in-Charge. Note: - Old bricks obtained against demolition shall be used.
Walling of random rubble stone masonry uncoursed with best quality lacally available harder stones such as granite, trap, basalt stone etc, wellbonded bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 14.00 here-in-before but except stones complete all as specified and directed by Engr-in-Charge. Note: - Old stones obtained against demolition shall be used.
Flush pointing to stone rubble masonry,uncourse or brought up to courses built in cm 1:4 complete all as specified and directed by Engr-in-charge.
Form work to sides and soffits of suspended slab, such as roof slab, floor slab, landing and similar work not exceeding 200mm thick (horizontal or sloping) for rough finish surfaces complete all as specified and directed by Engr-in-charge.
TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-in-charge.
TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr-in-charge.
Dismantling of framed trusses not exceeding 10.00 mtr span complete all as specified and directed by Engr-in-charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-charge.
Rolled mild steel work as in roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to grade Fe-420 W(Gde-E-50) quality-A, steel work duly painted with one shop coat of zinc chromate primer incl preparation of surfaces complete all as specified and directed by Engr-in-charge.
2nd class soft wood (Kail), as in scantling and similar work, clean sawn (framed/unframed) timber fixed in position complete all as specified and directed by Engr-in-charge.
S&F 2nd class soft wood beads, straight (any size) for glazed or gauzed joinery, renewed, including miters etc complete all as specified and directed by Engr-in-charge.
S&F 2nd class hard wood (sal/hollock), glazed and skelton shutters 35mm thick open rebated and prepared to receive glass, gauge,etc. (without sash bars), edges of framing palin, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I Section 8.24(a) supplied and fitted to chowkhats complete including fixing only iron mongery such as tower bolt, handle, hinges, aldrop bolt etc complete all as specified and directed by Engr-in-charge.
S&F factory made, 2nd class hard wood (sal/hollock), plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick complete including fixing only iron mongery such as tower bolt, handle, hinges, aldrop bolt etc complete all as specified and directed by Engr-in-charge.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each, and removing from site complete all as specified and directed by Engr-in-charge.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm but not exceeding 4 Sqm each, and removing from site complete all as specified and directed by Engr-in-charge.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each, and removing from site complete all as specified and directed by Engr-in-charge.
Taking down and refixing shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm each in same opening complete all as specified and directed by Engr-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tube for top & bottom rails. M.S. frame shall be covered with heat mouleded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in the frame at site as per specification clause No.8B.1 to 8B.10 and drawing on page No. 146 of MES SSR-2004 Part-II complete including fixing only iron mongery such as tower bolt, handle, hinges, aldrop bolt etc complete all as specified and directed by Engr-in-charge.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply & fixing in opening as per specification & drawing shown in SSR Part-II complete all as specified and directed by Engr-in-charge.
S&F aluminum handles cast type, anodised, 150mm size complete all as specified and directed by Engr-in-charge.
S&F100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed by Engr-in-charge.
S&F of 200 mm long mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and directed by Engr-in-charge.
S&F of mild steel sliding door bolt plate type 250 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engr-in-charge.
S&F of mild steel sliding door bolt plate type 300 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engr-in-charge.
S&F aluminum anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified and directed by Engr-in-charge.
S&F Mild steel pressed handle oval type stove enamelled black, 150mm size complete all as specified and directed by Engr-in-charge.
S&F in repair MS helical door spring 150mm size incl roller and roller plate fixed to wooden or steel frames incl necessary welding etc complete all as specified and directed by Engr-in-charge.
M&L for providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed by Engr-in-charge.
S&F of stainless steel wire clothcut to size, 0.36 mm nominal dia wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed by Engr-in-Charge.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel staple complete all as specified and directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works, conforming to Fe-290, Gde E-165 complete all as specified and directed by Engr-in-charge.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces complete all as specified and directed by Engr-in-charge.
S&F expanded metal exceeding 4.00 Kg per sqm cut to length, bent to shape and welded with MS angle iron frame complete all as specified and directed by Engr-in-charge.
S&F steel window (box type) factory made with sidehung shutter including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and directed by Engr-in-charge. Note: - (i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3. (ii) MS fillets, glazing wire gauge shall be measured and paid seprately.
Description all as per serial item No 47.00 here-in-before but without glazing bar complete all as specified and directed by Engr-in-charge. Note: - (i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 sheet 1/3 to 3/3. (ii) MS fillets, glazing, wire gauge shall be measured and paid seprately.
S&F factory made mild steel ventilators box type with upper top hung shutter and bottom fixed type shutters including pintol hinges and ,steel peg stay and one shop coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame complete all as specified and directed by Engr-in-charge.
Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and taring back side of frame complete all as specified and directed by Engr-in-charge.
Providing and fixing false ceiling with gypsum based ceiling tiles and frame work (with aluminium foil on one side) of size 595X595 mm of thickness not less than 9mm incl with GI powder coated frame angle/Tee grid frame work for ceiling with following specificatios :- (a) S&F angle of side 25x25x1mm powder coated. (b) 25x25X1mm GI powder coated at bottom Tee as in main member. (c) 25X25X1mm thick GI powder coated at bottom Tee as in cross members. (d) S&F 1.60mm dia GI suspenders along with adjustable clamps to maintain levelling incl fixing to ceiling fasteners as in ceiling, flat or sloppy as per manufacture's instructions complete all as specified and directed by Engr-in-charge.
0.63 mm thick corrugated, galvanised, mild steel sheeting with two corrugation side laps, fixed with 'L' or 'J' type cranked bolts in roof covering complete all as specified and directed by Engr-in-charge.
0.80mm thick , Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc, fixed with 'L' or 'J' type or cranked hook bolts and riveted at 20cm C/C in roofs & valley gutter etc complete all as spfd and directed by Engr-in-Charge.
Description all as per serial item No 54.00 here-in-before but except sheeting complete all as specified and directed by Engr-in-charge. Note: - Old sheet obtained against dismantling shall be used.
M&L 6mm thick Asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc. fixed with 'L' or 'J' type cranked bolts complete all as specified and directed by Engr-in-charge.
M&L Asbestos cement, one piece plain angular ridge 6mm thick fixed with 'L' or 'J' type cranked bolts complete all as specified and directed by Engr-in-charge.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet (profile sheets) 0.50mm thick of any colour as desired by GE, having tensile strength of 550 Mpa as in. roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour as desired by GE, having tensile strength of 550 Mpa as in. roof covering/cladding to wall, fixed with self tapping screws as specified as in ridges, hips, valley gutters etc complete all as specified and directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including CM bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge.
Glazed ceramic coloured tiles 300mm x 200mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles complete all as specified and directed by Engr-in-charge.
Non skid coloured ceramic tiles 7 to 8 mm thick, area of each tiles exc. 0.06 SQM and but n.exc. 0.11 SQM in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.complete all as specified and directed by Engr-in-Charge.
M&L for Non skid coloured 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-charge.
M&L Machine cut kota stone slab flooring, 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing, grinding and polishing etc over and incl 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-charge.
M&L Machine cut kota stone slab, 20-25mm thick in riser of steps, skirting, dado etc laid over 15mm thick plaster in CM (1:4) jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L Coloured chequered cement concrete tiles, machine pressed, factory made of size 250 x 250 x 22mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
75mm thick , Plain cement concrete, (Nominal Mix), Type C-2, 1:3:6 (using 40mm graded crushed stone aggregates) as in floors finished rough surface to receive floor finishes complete all as specified and directed by Engr-in-charge.
M&L 40mm thick plain cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Glass dividing strips, 3 mm, 38 mm wide inserted in posituin complete all as specified and directed by Engr-in-charge.
M&L for 100mm thick PCC type D-2 1:4:8, using 40mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement with spike rolling to surfaces or making impression of expanded metal, whilst the concrete is green complete all as specified and directed by Engr-in-charge.
50mm thick cement concrete (Nominal mix), type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection finished fair & even without using extra cement complete all as specified and directed by Engr-in-charge.
Plain cement concrete, (Nominal Mix), type C-2, 1:3:6 (using 40 mm graded crushed stone aggregates) as in surface channel and drain complete all as specified and directed by Engr-in-charge.
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc incl taking down existing APP membrane sheet complete all as specified and directed by Engr-in-charge.
Brushing neat cement slurry with 3.00kg cement per Sqm complete all as specified and directed by Engr-in-charge.
M&L for 10 mm thick cement plaster in cement mortar 1:4 and finished even and smooth without using extra cement incl water proofing compounding as per manufacturer's instructions complete all as specified and directed by Engr-in-charge. Note:- WPC shall be measured and paid separtely
Supply only integral water proofing compound, ISI marked complete all as specified and directed by Engr-in-charge.
M&L for APP based polymeric membrane minimum 3mm thick and minimum weight not less than 3kg/sqm reinforced with polyster non wove fabric matt (wt not less than 150 gms/sqm) laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS 3384-1965 of grade 85/25 @ 1.20 kg per Sqm at bottom of the membrane as bonding materials and a coat of bituminous aluminium primer on top complete all as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engr-in-charge.
M&L for 15 mm thick rendering on fair faces of brick or stone/concrete surfaces in cement mortar 1:4 and finished surface even and smooth without using extra cement complete with water proofing compound complete all as specified and directed by Engr-in-charge. (WPC shall be measured separtely)
M&L for 15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for 10 mm thick rendering on fair faces of brick /concrete surfaces as in ceiling in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for applying two coat of oil bond distemper on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed by Engr-in-charge.
M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified and directed by Engr-in-charge.
M&L for applying two coats of cement base paint on walls after preparation of newly plastered surfaces over a coat of white primer complete all as specified and directed by Engr-in-charge.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engr-in-charge.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-charge.
M&L precast cement concrete jallies 25mm thick (measured solid set in cement mortar 1:4 incl all moulding and necessry form work complete all as specified and directed by Engr-in-charge.
M&L for machine pressed precast cement concrete interlocking paver block 50% grey and 50% coloured any shape and size conforming to IS 15658-2006 of 60mm thick, M-35 over and incl 75mm thick PCC type D2 (1:4:8) and 25mm thick sand cushioning complete all as specified and directed by Engr-in-charge.
Repairs to existing steel rolling shutters without ball bearing by taking down top cover, anchoring rod, spring etc and providing new springs and anchoring rod, replacing the worn out strips, safety lever lock of shutters and welding of handle, hasp staple and other broken articles etc, greasing the spring, guide rail, shaft etc and making functional and errecting in position, including refixing of top cover/hood etc, and refixing in same opening and making good in CM 1:3/PCC to match the existing surface, opening n.exc. 10 sqm each and finally painting with two coats of synthetic enamel paint complete all as specified and directed by Engr-in-charge.
S&F in repair PVC tank cover suitable for tanks 500 & 1000 Ltrs tank incl securing with MS binding wires complete all as specified and directed by Engr-in-charge.
M&L uprooting of plants (girth n.exc 15 cm of trunk to any type of plants 100ml grown along the pipe or walls, chajja, parapets and roof of buildings (incl multistoried) and making good the surface as per existing surface and pouring acide not less than 100 ml for each plant in the roof to avoid further growth as complete all as specified and directed by Engr-in-charge.
M&L for welding at site at any floor,any description MS butt hinges any size, projecting type hinges to steel window and similar articles etc(after taking down shutter),refixing in the position the same and making functional complete all as specified and directed by Engr-in-Charge.
Taking down steel rolling shutters manually operated type with ball bearing cover hood and channel,anchoring rod etc of size upto 25 sqm each complete all as specified and directed by Engr-in-Charge.
M&L of steel rolling shutters 1.25mm thick without ball bearing, as specified including top cover,anchoring rod,hasp & staple & one shop caot of primer,erected in position as indicated, complete push, pull or manual type complete all as specified and directed by Engr-in-Charge.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by Engr-in-Charge.
S&F ball bearibg for rolling shutters as per existing complete all as specified and directed by Engr-in-Charge.
Hacking out old broken glasses (any thickness, size, quality or description) from wooden frames or steel frames, glazed with putty or fixed with wooden beads complete all as specified and directed by Engr-in-charge.
3mm thick sheet glass ordinary quality, and glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-charge.
3 mm thick figured glass pin head type and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed by Engr-in-charge.
SINGH CONST CO
VARDHMAN INTERNATIONAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .