Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAdmitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | L1 | Admitted-Finance | |
| 2 | L2₹17.2 L+₹44,604 (2.66%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical DELHI EAST DELHI 110092 INDIA UDYAM DL 02 0018735 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Not fulfill the NIT condition no. 2 (Viii) |
| Sl No | Description | Qty | Unit | Devraj Enterprises L1 | Raj Engineering Co. L2 |
|---|---|---|---|---|---|
| 1.00 | Installation, Operation & Maintenance of 50 HP sewage pump-set trolley on hiring basis with all necessary accessories such as Starter/Panel,Non-Return Valves, sluice valve, bends, flanges, Cables, MS suction line properly lowered into the sump-well, conforming to the site depth and MS delivery pipeline or other suitable pipeline is to be laid as per site requirement. This includes all required consumables such as nuts-bolts, washers, rubber packing, and execution activities like welding and alignment followed by proper reinstatement. Barricading with warning boards and external lighting arrangement around the trolley shall be placed to ensure public safety.
The job also includes the erection of a temporary tin shed at the site to house the pump-sets, electrical panels, and provide shelter to operating staff including minor civil works required during execution of work. Round-the-clock staffing with helper if required is to be ensured for continuous monitoring and operation as per the direction of the Engineer-in-Charge.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 7,56,000 ₹8,92,080 Lowest | 7,65,000 ₹9,02,700 |
| 2.00 | Installation, Operation & Maintenance of a 125 KVA Soundless DG Set as per CPCB IV+ norms in acoustic enclousure with ancillary work required for DG set for operation of above sewage pump set.
Note: Diesel required for running the pump-sets shall be provided by the department as per site conditions.
Note: If Electric meter will be installed by DISCOM agency then there will be no requirement of Said DG Set at Site.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 30,600 ₹36,108 Lowest | 45,000 ₹53,100 |
| 3.00 | Installation, Operation & Maintenance of 25 HP sewage pump-set trolley on hiring basis with all necessary accessories such as Starter/Panel,Non-Return Valves, sluice valve, bends, flanges, Cables, MS suction line properly lowered into the sump-well, conforming to the site depth and MS delivery pipeline or other suitable pipeline is to be laid as per site requirement. This includes all required consumables such as nuts-bolts, washers, rubber packing, and execution activities like welding and alignment followed by proper reinstatement. Barricading with warning boards and external lighting arrangement around the trolley shall be placed to ensure public safety.
The job also includes the erection of a temporary tin shed at the site to house the pump-sets, electrical panels, and provide shelter to operating staff including minor civil works required during execution of work. Round-the-clock staffing with helper if required is to be ensured for continuous monitoring and operation as per the direction of the Engineer-in-Charge.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 6,12,000 ₹7,22,160 Lowest | 6,21,000 ₹7,32,780 |
| 4.00 | Installation, Operation & Maintenance of a 50 KVA Soundless DG Set on hiring basis as per CPCB IV+ norms in acoustic enclousure with ancillary work required for DG set for operation of above sewage pump set.
Note: Diesel required for running the pump-sets shall be provided by the department as per site conditions.
Note: If Electric meter will be installed by DISCOM agency then there will be no requirement of Said DG Set at Site.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 19,800 ₹23,364 Lowest | 25,200 ₹29,736 |
Tender Value
Refer Docs
EMD Value
₹33,700
Closing Date
5 Oct 2026, 3:00 pmClosed
Executive Engineers E(EnM)M-09
C-2A Block Opp. Geeta Mandir Janakpuri
Deployment of 50HP and 25HP Sewage Trolley and allied equipment on hiring basis at Rani Jhansi Road Mahavir Nagar and Outer Ring Road T-Point in Ward No. 103 under Tilak Nagar AC-29.
2026_DJB_299162_4
NIT No. 11 (2026-27)EE(EnM)M-9
Open Tender
Miscellaneous Works
Works
60 days
C-2A Block Opp. Geeta Mandir Janakpuri
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
DJB Account No. 50448339804
₹33,700
8 Oct 2026
29 Sept 2026
5 Oct 2026
29 Sept 2026
5 Oct 2026
29 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | Installation, Operation & Maintenance of 50 HP sewage pump-set trolley on hiring basis with all necessary accessories such as Starter/Panel,Non-Return Valves, sluice valve, bends, flanges, Cables, MS suction line properly lowered into the sump-well, conforming to the site depth and MS delivery pipeline or other suitable pipeline is to be laid as per site requirement. This includes all required consumables such as nuts-bolts, washers, rubber packing, and execution activities like welding and alignment followed by proper reinstatement. Barricading with warning boards and external lighting arrangement around the trolley shall be placed to ensure public safety.
The job also includes the erection of a temporary tin shed at the site to house the pump-sets, electrical panels, and provide shelter to operating staff including minor civil works required during execution of work. Round-the-clock staffing with helper if required is to be ensured for continuous monitoring and operation as per the direction of the Engineer-in-Charge.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 80 | ₹14,400 | 18% |
| 2 | Installation, Operation & Maintenance of a 125 KVA Soundless DG Set as per CPCB IV+ norms in acoustic enclousure with ancillary work required for DG set for operation of above sewage pump set.
Note: Diesel required for running the pump-sets shall be provided by the department as per site conditions.
Note: If Electric meter will be installed by DISCOM agency then there will be no requirement of Said DG Set at Site.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 80 | ₹14,400 | 18% |
| 3 | Installation, Operation & Maintenance of 25 HP sewage pump-set trolley on hiring basis with all necessary accessories such as Starter/Panel,Non-Return Valves, sluice valve, bends, flanges, Cables, MS suction line properly lowered into the sump-well, conforming to the site depth and MS delivery pipeline or other suitable pipeline is to be laid as per site requirement. This includes all required consumables such as nuts-bolts, washers, rubber packing, and execution activities like welding and alignment followed by proper reinstatement. Barricading with warning boards and external lighting arrangement around the trolley shall be placed to ensure public safety.
The job also includes the erection of a temporary tin shed at the site to house the pump-sets, electrical panels, and provide shelter to operating staff including minor civil works required during execution of work. Round-the-clock staffing with helper if required is to be ensured for continuous monitoring and operation as per the direction of the Engineer-in-Charge.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 80 | ₹14,400 | 18% |
| 4 | Installation, Operation & Maintenance of a 50 KVA Soundless DG Set on hiring basis as per CPCB IV+ norms in acoustic enclousure with ancillary work required for DG set for operation of above sewage pump set.
Note: Diesel required for running the pump-sets shall be provided by the department as per site conditions.
Note: If Electric meter will be installed by DISCOM agency then there will be no requirement of Said DG Set at Site.
Period: 60 days x 3 Shift = 180 Shift. | 180 | shifts | 80 | ₹14,400 | 18% |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_399236.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .