| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.8 L+₹83,497.68 (4.93%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹18.2 L+₹1.3 L (7.61%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹18.4 L+₹1.5 L (8.61%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/s Hanspal Enterprises L2 | Industrial Traders L4 | M/s Ranaji Construction Co L3 | VISHAL TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for comprehensive periodic maintenance, repair & servicing of Central Air conditioning plant of capacity 100 TR (Make : Voltas, Model : EGWFXR1001MLB2) and connected ventilation system existing at 39 FAD Bharatpur as per manufacturers instructions by authorised dealer of company for 2 Nos of chilling machine of screw type compressor 100 TR , each single stage, 3000 RPM, 415 Volts, 3 Phase, 50 Hz, semihermatic electric motor of capacity 67 KW, shell and tube type condensor with carbon steel plate, copper tube, externally and internally to pass water flow 1400 USG/PM with carbon plate shell and tube flooded type chiller unit, including greasing, lubrication of moving parts and pressure tasting for entire system of AC plant of all two set of condenser, compressor and circulating system with CO2/Nitrogen gas and retain to allow the pressure for three days. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage premanently and recommissioning of 100 TR water cooled Screw Chiller complete all as specified and directed by Engineer-in-Charge.
Note: (i) Cost of spares, refrigrant and compressor oil as wherever required to be replaced shall be measured and paid separately under respective items) | 3 | Each Job | 1,24,000 ₹3,72,000 | 1,40,000 ₹4,20,000 | 40,000 ₹1,20,000 Lowest | 1,17,499 ₹3,52,497 |
| 2.00 | Supply in replacement of old lube oil of Screw compressor, flushing and replacement with New Lube oil all as per specification of OEM standard (SOLSET-120) including testing complete to the entire satisfaction of Engr-in-Charge. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 60 | Litre | 3,300 ₹1,98,000 | 3,800 ₹2,28,000 | 1,000 ₹60,000 Lowest | 2,999 ₹1,79,940 |
| 3.00 | Supply in replacement of unserviceable Drier Core as per existing site complete all as specified and directed. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before).
Make:- Danfoss. | 2 | Each | 4,900 ₹9,800 | 4,000 ₹8,000 | 3,000 ₹6,000 Lowest | 4,999 ₹9,998 |
| 4.00 | Supply in replacement of unserviceable Filter Drier all as per existing site complete all as specified and directed. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before).
Make:- Danfoss. | 2 | Each | 4,050 ₹8,100 | 4,000 ₹8,000 | 3,000 ₹6,000 Lowest | 3,999 ₹7,998 |
| 5.00 | Supply for charging of Refrigerant R-134A in the system to its rating capacity to the extent to full fill required temperature conditions and service leak testing and complete all as per specification as directed by Engineer-in-Charge. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 205 | Kg | 1,300 ₹2,66,500 | 1,300 ₹2,66,500 | 1,100 ₹2,25,500 Lowest | 1,299 ₹2,66,295 |
| 6.00 | Supply in replacement of old temperature sensors in the incoming/outgoing water pipeline of the chiller unit all as per existing site complete to the entire satisfaction of Engr-in-charge (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 2 | Each | 3,100 ₹6,200 | 3,400 ₹6,800 | 1,000 ₹2,000 Lowest | 4,499 ₹8,998 |
| 7.00 | Supply in replacement of old pressure transducers on the chiller unit all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). Make : MCS Control/Danfoss or suitable equivalent. | 2 | Each | 7,300 ₹14,600 | 7,000 ₹14,000 Lowest | 10,000 ₹20,000 | 7,499 ₹14,998 |
| 8.00 | Supply in replacement of old driver for Expansion valve all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge. Make: MCS Control/Danfoss or suitable equivalent (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 2 | Each | 4,240 ₹8,480 | 3,800 ₹7,600 | 2,000 ₹4,000 Lowest | 3,999 ₹7,998 |
| 9.00 | Supply in replacement of old unserviseable Expansion valve controller all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge. Make: MCS Control/Danfoss or suitable equivalent (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 2 | Each | 4,000 ₹8,000 | 4,500 ₹9,000 | 2,500 ₹5,000 Lowest | 3,999 ₹7,998 |
| 10.00 | Supply in replacement of Switching Fuse Unit (SFU) in chiller unit panel of Capacity 160-200 Amps complete all as specified and directions by Engineer in charge. Make : Siemens/L&T or equivalent in C&S/CG (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | 2 | Each | 400 ₹800 | 600 ₹1,200 | 15,000 ₹30,000 | 199 ₹398 Lowest |
Tender Value
₹18.8 L
EMD Value
₹37,500
Closing Date
15 Apr 2026, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2025_MES_741470_4
CWE/MTR/BPR/ of 2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹37,500
Yes
16 Jun 2026
1 Apr 2026
22 Apr 2026
1 Apr 2026
15 Apr 2026
8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | M&L for comprehensive periodic maintenance, repair & servicing of Central Air conditioning plant of capacity 100 TR (Make : Voltas, Model : EGWFXR1001MLB2) and connected ventilation system existing at 39 FAD Bharatpur as per manufacturers instructions by authorised dealer of company for 2 Nos of chilling machine of screw type compressor 100 TR , each single stage, 3000 RPM, 415 Volts, 3 Phase, 50 Hz, semihermatic electric motor of capacity 67 KW, shell and tube type condensor with carbon steel plate, copper tube, externally and internally to pass water flow 1400 USG/PM with carbon plate shell and tube flooded type chiller unit, including greasing, lubrication of moving parts and pressure tasting for entire system of AC plant of all two set of condenser, compressor and circulating system with CO2/Nitrogen gas and retain to allow the pressure for three days. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage premanently and recommissioning of 100 TR water cooled Screw Chiller complete all as specified and directed by Engineer-in-Charge.
Note: (i) Cost of spares, refrigrant and compressor oil as wherever required to be replaced shall be measured and paid separately under respective items) | - | Each Job | - | - |
| - | Supply in replacement of old lube oil of Screw compressor, flushing and replacement with New Lube oil all as per specification of OEM standard (SOLSET-120) including testing complete to the entire satisfaction of Engr-in-Charge. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Litre | - | - |
| - | Supply in replacement of unserviceable Drier Core as per existing site complete all as specified and directed. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before).
Make:- Danfoss. | - | Each | - | - |
| - | Supply in replacement of unserviceable Filter Drier all as per existing site complete all as specified and directed. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before).
Make:- Danfoss. | - | Each | - | - |
| - | Supply for charging of Refrigerant R-134A in the system to its rating capacity to the extent to full fill required temperature conditions and service leak testing and complete all as per specification as directed by Engineer-in-Charge. (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Kg | - | - |
| - | Supply in replacement of old temperature sensors in the incoming/outgoing water pipeline of the chiller unit all as per existing site complete to the entire satisfaction of Engr-in-charge (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Each | - | - |
| - | Supply in replacement of old pressure transducers on the chiller unit all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). Make : MCS Control/Danfoss or suitable equivalent. | - | Each | - | - |
| - | Supply in replacement of old driver for Expansion valve all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge. Make: MCS Control/Danfoss or suitable equivalent (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Each | - | - |
| - | Supply in replacement of old unserviseable Expansion valve controller all as per existing site and specifications complete to the entire satisfaction of Engr-in-charge. Make: MCS Control/Danfoss or suitable equivalent (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Each | - | - |
| - | Supply in replacement of Switching Fuse Unit (SFU) in chiller unit panel of Capacity 160-200 Amps complete all as specified and directions by Engineer in charge. Make : Siemens/L&T or equivalent in C&S/CG (Note : Labour for fixing shall be included in serial item No 1.00 here-in-before). | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Ftender.pdf
Tender Documents • 1.36 MB
BOQ_850082.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .