| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI MENUGA MANJUNATH
Garrison Engineer North Udhampur, Jammu and Kashmir-182101
JOB ORDER FOR REPAIR/MAINT OF STP AT 71 SUB AREA UNDER GE (NORTH) UDHAMPUR
2022_MES_542019_1
3016/Q/02/E3 dt 29 Jul 2022
Open Tender
Miscellaneous Works
Works
90 days
GE (NORTH) UDHAMPUR
As per Tender documents
3 documents required · 3 mandatory
₹0
Exempted
23 Aug 2022
30 Jul 2022
23 Aug 2022
30 Jul 2022
20 Aug 2022
30 Jul 2022
30 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5m deep and not exceeding 1.5m wide for laying of underground cable, electric pole and getting out complete all as directed.
Returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
M&L for dry sand cushioning to underground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as spec.
Supply and lay in replacement XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting of bituminous road/chasing to any surface and making good to the disturbed surface to match the existing.
Disconnecting the defective/burnt electric induction motor & dismantling from the foundation, shifting to workshop opening checking for defects Varnishing, drying, greasing bearing, insulating the terminals connection etc incl carrying out minor repair (winding will be paid separately).
Rewinding the electric induction motor of capacity 1 HP suitable to run on 415V, AC, 50Hz supply with copper enameled copper wire of suitable gauge/size including proper insulation and making connection to the terminal plate complete.
Disconnecting the Non clog pump and dismantling from the foundation, shifting to workshop opening checking for defects parts, greasing, bearing, etc incl carrying out minor repair.
Disconnecting the sullage water pump and dismantling from the foundation, shifting to workshop opening checking for defects parts, greasing, bearing, etc incl carrying out minor repair.
Disconnecting the air compressor and motor dismantling from the foundation, shifting to workshop opening checking for defects parts, greasing, oiling, bearing, etc incl carrying out minor repair.
Rewinding the air compressor and motor of capacity 5 HP suitable to run on 415V, AC, 50Hz supply with copper enameled copper wire of suitable gauge/size including proper insulation and making connection to the terminal plate complete.
Replacement of complete worn out LT panel wiring after disconnecting all electrical connection from the motor and making connection testing and commissioning with new parts as under:-
(i) TPN 16 To 32 AMP
(ii) TP 10 AMP
(iii) 3 Pole Power Auxiliary Contactors Type MNX-09, rating 25 Amp.
(iv) Three Phase Indicator-Red, Yellow & Blue.
(v) Three Phase Timer Switch.
S & F PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable of size 4 Sqmm, 3 core 1100 Volts,
Supplying and laying of PVC pipes of size 50mm dia fixed complete in floors etc.
Supplying and laying of PVC pipes of size 40mm dia fixed complete in floors etc.
S & F chlorinated polyvinyl chloride (PVC) flange of size 50 mm with rubber gasket, bolts, nuts and washer etc.
S & F chlorinated polyvinyl chloride (PVC) ball valve of size 50 mm completed all as specified
S & F chlorinated polyvinyl chloride (PVC) ball valve of size 40 mm completed all as specified
M& L for testing of treated water collected from STP by authorized lab as per required parameter's i.e. PH, TSS, BOD, COD, Oil & Grease etc and to submit Certificate/report as approved by Engr-in-charge.
S & F carbon and sand filter rubber gasket (as per site required) with bolts, nuts and washer etc. complete with connection and commissioning.
vijay kumar gupta and co
K S BUILDERS
stage.html
html • 0.02 MB
finance_605827.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .