| 1 | L1₹19.6 LAccepted-AOC BANSIPURA MORAR GWALIOR 474006 M P | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.2 L+₹1.3 L (6.35%)Rejected-Finance NEAR G E COLLEGE RASHOOLPUR MAHARAJPUR GWALIOR MP 475110 | GWALIOR | MADHYA PRADESH | 475110 | L2 | Rejected-Finance Not being lowest tender |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
29 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA GWALIOR
GE AF TA GWALIOR-474020
REPAIR/MAINT OF WATER SUPPLY DISTRIBUTION MAIN SYSTEM AND CONNECTED WORKS IN TECH AREA AT AF STN GWALIOR
2021_MES_477318_1
8900/1330/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹43,000
Yes
26 Nov 2021
23 Sept 2021
6 Nov 2021
23 Sept 2021
29 Oct 2021
7 Oct 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep, in any type of soil including forming sides and bottom surfaces to required level / slope / gradients etc for taking down/laying of the pipe lines complete all as specified and directed at site. Note: The disturbed surfaces of roads/paths/plinth etc shall be made good by the contractor to match with the existing surfaces without any extra cost.
Returning, filling in, excavated soil in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing of excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Disconnecting and taking down old existing steel tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union,elbow socket etc, all as directed and specified for the following sizes :- (a) 80 mm bore
(b) 50 mm bore
(c) 40 mm bore
(d) 25 mm bore
(e) 20 mm bore
(F) 15 mm bore Note :- Excavation & earth work shall be measured and paid separetely under respective item of Sch 'A'/BOQ.
Supply, laying, jointing and testing galvanized iron water tubing, medium grade, including all necessary GI fittings /accessories laid in trenches complete all as specified and directed for the following sizes (a) 80mm bore
(b) 50 mm bore
(c) 40 mm bore
(d)25 mm bore
(e) 20 mm bore
(f) 15 mm bore
M & L for ISI Marked, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe complete all as specified and directed for following bore of pipes:- (a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d)20mm bore
(e) 15mm bore
M & L for Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete includig taking down existing unserviceable bib taps all as specified and directed for 15mm bore pipe.
Dismantling of leaked flanged joint and M&L for rubber gasket joints in flanged end cast iron pipes and fittings complete with and including minimum 3 mm thick rubber/fibre gasket and necessary mild steel nuts, bolts & washers all as specified and directed for following sizes:- (a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
M&L for cutting of existing CI/GI pipe line in position for insertion of collars or other fittings including dewatering etc complete all as specified and directed for the following bore of pipes:- (a)150 mm bore
(b) 100 mm bore
(c) 80 mm bore. Note : S&F of insertion of fittings etc shall be measured & paid for separately under appropriate item of Sch 'A').
M& L for new run lead joint by new lead pig and making new joint by spun yarn and caulking etc all as specified and directed for the following sizes :- (a)150 mm
M& L for repairing of leaked lead joint by taking out lead and making lead joint by retrived lead and extra lead required including spun yarn and caulking including necessary excavation and earth work, bailing of water, if any, all as specified and directed for the following sizes :- (a)150mm
M& L for repairing of leaked /broken GI pipe including necessary cutting threading and Re fixing with new GI Fitting, excavation and earth work, bailing out water etc complete all as specified and directed for the following sizes : Note; 1 : S&F of insertion of GI fittings and excavation shall be measured & paid for separately under appropriate item of Sch 'A'/BOQ Note :2 - leakage shall be made functional within a 48 Hrs otherwise a penalty @ Rs 1000/- per day shall be recovered from the payment due . (a) GI PIPE 80mm bore
(b) GI pipe 80 mm bore
(c) GI pipe 50 mm bore
(d) GI pipe 40 mm bore
(e) GI pipe 25 mm bore
(f) GI pipe 20 mm bore
(h) GI pipe 15 mm bore
Supply only GI union for 80 mm bore pipe
Supply only GI union for 50 mm bore pipe
Supply only GI union for 40 mm bore pipe
Supply only GI union for 25 mm bore pipe
Supply only GI union for 20 mm bore pipe
Supply only GI union for 15 mm bore pipe
Supply only nipple for 80 mm bore pipe
Supply only nipple for 50 mm bore pipe
Supply only nipple for 40 mm bore pipe
Supply only nipple for 25 mm bore pipe
Supply only nipple for 20 mm bore pipe
Supply only nipple for 15 mm bore pipe
Supply only GI Socket for 80 mm bore pipe
Supply only GI Socket for 50 mm bore pipe
Supply only GI Socket for 40 mm bore pipe
Supply only GI Socket for 25 mm bore pipe
Supply only GI Socket for 20 mm bore pipe
Supply only GI Socket for15 mm bore pipe
Supply only GI Tee for 80 mm bore pipe
Supply only GI Tee for 50 mm bore pipe
Supply only GI Tee for 40 mm bore pipe
Supply only GI Tee for 25 mm bore pipe
Supply only GI Tee for 20 mm bore pipe
Supply only GI Tee for 15mm bore pipe
Supply only CI " D" Joint for 80 mm bore pipe
Supply only CI " D" Joint for 50 mm bore pipe
Supply only CI " D" Joint for 40 mm bore pipe
M&L for construction of brick masonry valve pit / chamber complete with 3mm thick MS sheet cover with locking arrangement of size 1050 mm x 1050 mm x 1050 mm (depth) (internal dimensions) all as shown on CE(AF)/TD/EM/01 Sheet 1/1 dt 16 Mar 1993 with and including necessary excavation & earth work in any type of soil complete all as specified and directed.
All as per Sl No 14.00 here-in-before but, size 750 mm x 750 mm x 750 mm (depth) (internal dimensions)
All as per Sl No 14.00 here-in-before but, size 600 mm x 600 mm x 600 mm (depth) (internal dimensions)
S&F in replacement spindle with gutka, of high tensile steel complete including rubber packing, nuts and bolts and washers as per sample for 150 mm bore sluice valve complete all as specified and directed
All as per Sl No 17.00 here-in-before but,100 mm bore sluice valve
All as per Sl No 17.00 here-in-before but, 80 mm bore sluice valve
Taking down old rusted/ unserviceable check nuts from sluice valve including M&L for new check nuts brass/ gun metal (a)150 mm bore sluice valve
(b) 100 mm bore sluice valve
(c) 80 mm bore sluice valve
Taking up or down existing cast iron sluice valve of any description and in any position, removing from site including taking out joints complete all as specified and directed for the following sizes :- NOTE:- Sluice valves other than those dismantled with taking up or down of cast iron pipe lines shall be measured and paid for under this item (a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supply, installation, fixing, jointing and testing, ISI Marked, cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, jointed with and including jointing material such as rubber or fibre gasket, nuts, bolts washers etc and tested complete all as specified and directed for following bores :- (a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Taking up or down exiting cast iron non return valves of any description and in any position, removing to stores including taking out joints complete all as specified and directed for the following sizes: (a)100 mm bore
(b) 80 mm Bore
Supply and fixing, 100mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. Make: Kirlosker/Upadhaya/Kajriwal or make as approved by GE.
Supply and fixing, 80mm bore, ISI Marked, cast iron non return valve, both ends flanged jointed and tested complete all as specified and directed. Make: Kirlosker/Upadhaya/Kajriwal or make as approved by GE.
Disconnecting and taking down old existing cast iron/DI pipe line/ water main and connections of any description/ grade including lead if any and in any position in trenches/under floors / etc including all fittings/accessories and fixtures such as bends, union, elbow socket etc, all as directed and specified for the following sizes :-
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supplying ,laying, jointing & testing in trenches ductile iron pipes with spigot and socketed ends centrifugally cast (spun cast) class K-9 suitable for Titen joints complete all as specified and directed for the following size:-
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore NOTE :- Earth work, and CI specials/ fittings of the pipes shall be measured and paid for separately under respective item of Schedule `A'.
M&L for titen joint suitable for K-9 Ductile iron pipe complete all as specified and directed by Engineer-in-Charge for the following size:-
(a)150 mm bore
(b)100 mm bore
(c) 80 mm bore
supply & fixing in replacement of PVC float valve complete all as specified and directed for the following sizes: (a) 40 mm bore
(b) 25mm bore
(c) 20 mm bore
(d) 15 mm bore
Supply, installation, and testing of DIGITAL WATER LEVEL INDICATOR DEVICE, operating on single phase supply ,direct display in 150 mm size digit system in meter / centimeter of water level of OVER HEAD TANK ensuring alarm while water fall or rise at predetermined limit .1 minute auto off alarm. (B)The entire unit must operate through a compact electronic circuit ,which must ensure reliable operation at 230 volts +/-5% with reliable in digit display % alarm at low &high level of OVER HEAD TANK (C) The circuit must be housed in M.S .CRC sheet box with nylon moulded connection strips . The level system must be resistance transducer and shoul be unaffected by corrosion and other contents available in water .The product must be controlled by micro switch (should not be sensor system). (D) The whole unit must electronically controlled and the upper level and lower level indicator must be highly sensitive MICRO SWITCH:The complete unit must be in two parts. Each complete part must be fitted in MSCRC sheet box seperately. One must be installed at over head tank and second at pump house with proper powder coating paints. (E )the required flexible copper cable of 0.5 sq mm , 3 core size from over head tank to pump house shall be nmeasured and paid for separately Model No -DDS-6 of Make :- SECO or equivalent make as approved by GE
Supply & Fixing In replacement flexible cable of 0.5 sq mm, 3 core size from over head tank to pump house
Supplying, fixing, jointing and testing cast iron/ductile iron specials/fittings such as bend, tee, socket, color, Reducer, Tail Pieces etc. suitable for spigot and socketed/ flanged end pipes of 150 mm bore and below complete all as specified and directed by Engineer-in-Charge.
M/s Kishan Construction Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .