Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC MALLICK JAYANTI BAGAN KUMAR BAGAN JHAPPUKUR POST SAHAGANJ DIST HOOGHLY HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹13.9 L+₹1.9 L (15.8%)Rejected-Finance JAGANNATHPUR AMTA HOWRAH 711401 | AMTA | HOWRAH | WEST BENGAL | 711401 | L2 | Rejected-Finance HIGHEST RATE QUOTED | |
| 3 | L3₹14.3 L+₹2.3 L (19.0%)Rejected-Finance 14 NANILAL CHATTERJEE LANE RISHRA 712248 WEST BENGAL | RISHRA | HOOGHLY | WEST BENGAL | 712248 | L3 | Rejected-Finance HIGHEST RATE QUOTED | |
| 4 | L4₹14.5 L+₹2.5 L (21.0%)Rejected-Finance SATYAPIRTALA CHINSURAH DIST HOOGHLY 712101 | CHINSURAH | HOOGHLY | WEST BENGAL | 712101 | L4 | Rejected-Finance HIGHEST RATE QUOTED | |
| 5 | Rejected-Technical P O VILL SUGANDHA DIST HOOGHLY WEST BENGAL | SUGANDHA | HOOGHLY | WEST BENGAL | 712102 | - | Rejected-Technical technically not qualified |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
18 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Office of The Executive Engineer, PWD, Hooghly Electrical Division , Purta Bhavan 3rd Floor , Sarat Sarani , Kodalia , Hooghly
Electrical Installation work in OPD building for accomodation of Nursing College at Serampore Walsh SD Hospital, Serampore in the District of Hooghly_Electrical Installation work.
2022_WBPWD_418484_1
WBPWD/EE/HED/NIeT-18/2nd call2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹27,000
HOOGHLY ELECTRICAL DIVISION
21 Dec 2022
1 Nov 2022
21 Nov 2022
1 Nov 2022
18 Nov 2022
1 Nov 2022
10 Nov 2022
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch of grey/black colour fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
8 Mtr [4(c)/ E-25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with MODULAR type switchof grey/black colour as per GS.
On Board [ 3 (i) / E- 20 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm) + 1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ]
S & F solderless Copper socket by crimping of Copper wires.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
d) 6 sq mm [9(iii) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
240 x 200 x 65 [11(d)/E-4 ,12(d)/E-5]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Polycab/Havells as approved E.I.C]
4 Core 25 Sq. mm
4 Core 70 Sqmm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Above 35 to 95 Sq. mm [ 5(ii)/ F- 3 ]
Laying of 3/3½/4 core cable of following sizes on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting as GS.
upto 3/4 core 25 Sq. mm [ 2(b)/ F- 1 ]
above 31/2 core 50 sqmm and upto 31/2 core 90 sqmm [ 2(d)/ F- 1 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 25 Sq. mm [7(c)/F4 & 8(b- xiii) /F5]
4 Core 70 Sq. mm [7(c)/F4 & 8(b) /F5]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC.
8 Way ( Up to 160 A ) Make - Legrand, Enclosure 607914/Siemens-Enclosure-8GB31571RC)/Schneider-Enclosure-A9HVD08M/L&T Enclosure- (LTVD08MGN) as approved by E.I.C] [15 / D- 11 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ Schneider/ Crabtree) as per direction of EIC. )
4 Way Make - Legrand, Enclosure-607715/Schneider,Enclosure-A9HTND04/Crabtree, Enclosure- (DCDKTHODCW04) or equivalent cat of LT/Siemens as approved E.I.C] [ 14 / D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens Enclosure(8GB32102RC14)/ Schneider Enclosure-(A9HSND12) or equivalent model of Legrand/Crabtree as approved by EIC] [ 13 / D- 9 & D-10 ]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing of digital time switch (Mk- L&T, AUTS02DIG00) in existing 2 way SS encloser as per direction of EIC.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens as per direction of EIC.].
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 as per GS
6 Way (Horizontal) [16/D-12]
4 Way/8 Way (Vertical) [16/D-12]
Supplying and fixing 415V, FP Changeover switch with Sheet Steelenclosure on angle iron frame on wall with nuts bolts etc.
160 A [Make - Havells/HPL/LT as approved by E.I.C] [3(a)/D-2]
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [ Make- L&T/Siemens/Havells as approved by EIC]. [4(a)/D-3]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
6 module 1(b)/E-17]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
2 module 2(a)/E-17]
Supplying & Fixing modular type socket /socket (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/ Equivalent make as approved by E.I.C), in exsisting Modular board incl. connections.
6 A 5-pin modular type three pin socket [4(a)/E-17]
6 A modular type switch [3(a)/E-17]
16 A modular type socket [4(b)/E-17]
16 A modular type switch [3(b)/E-17]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand-Model Arteor/Myrius or equivalent model of Crabtree/Equivalent make as approved by E.I.C), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [ 12 / E-18]
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17 / E-19]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [ 5(b) / E-17]
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25/32 A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 25/32 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC.
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube.
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 1 no. 18W Master LED Tube.
Twin fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3242 or equivalent model of Havells/CG / Bajaj / Wipro as approved by E.I.C] incl. 2 no. 18W Master LED Tube.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supply and fixing 14 W LED bulb(Bajaj/CG/Philips/wipro) on existing batten holder
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [ 14d/C-2 ]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ]
Dismantling the existing damaged defective unuseable electrical Installation materials.
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha-Striker or equivalent model of Havells/CG/Orient as approved by E.I.C)
a. 1200 mm Sweep
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supplying & Fixing MS fan clamp of two piece type for RCC as per approved specification as per GS. [ 29/D-14 ]
Engraving the deptt. number with 10 mm lettering on the body as per GS.[ 24 (a) / C-3 ]
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS[ 26 (a) / C-3 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
Supply & fixing heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per G.S. )
12"( 300mm ) Speed 920 RPM
9"( 230mm ) Speed 1370 RPM
S/F GI sheet (20 SWG) metal cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [33/D-14]
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. [Raw Power LT Panel]
Construction Details : All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incomming Switch : (a) 415V 250 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95642 or equivalent cat of SIEMENS/ABB) in open exexution ------- 1 No.
Bus Bar : 500V, 300 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x40 mm x 5 mm + 1x50 mm x 5 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Switches : (a) 415V 160 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95713 or equivalent cat of SIEMENS/ABB) in open exexution - 4 nos. (b) 415V 63 Amps TPN SDF units with DIN type fuse link (Make:- L&T : Cat No.-SK95421 or equivalent cat of SIEMENS/ABB) in open exexution----3No.
Metering Panel a) Advanced LED Multifunction Meter Digital Type Load Monitor ( Make L&T, Cat No.- WL442011OOOO) - 1 No. b)LED single function Meter ( Make L& T, Model- CAT No.- WL111020OOOO or equivalent)- for ammeter --- 3 nos. c)LED single function Meter ( Make L& T, Model no..WL112020OOOO or equivalent) for voltmeter-- 3 nos. d) 230V R.Y.B. LED indicator lamp -(SIEMENS/L&T) ---- 3 nos. d) 200/5 Amp ratio C.T (Kappa) --- 3 nos. e) S & F 6 Amp SPMCB(Make-SIEMENS/LT/Legrand)---6 nos.
All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to all outgoing mains i.e., 160A & 63ATPN SDF are to be made by 4 x 20 mm x 5mm and 16 sq. mm flexible pvc insulated FR Cu cable respectively and also for metering arrangements are to be made by suitable size of Copper wire with proper socketing of the end of each wire leads.
Earthing :- A separate continuous aluminum earth busbar of size 50mm x 6mm shall run across the full length of the panel board and brought outside the panel. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 9 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C. All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-8 SWG [5(a)(ii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
Add GST @18% Rs.
Add LWC @1% except item no.-8,31 & 39 - Rs.
R.K. ENTERPRISE
SANDIP TRADERS
R.D.ELECTRICAL ENGINEERING CO
techsummary_825450.pdf
PDF • 0.69 MB
finance_825450.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_825450.pdf
PDF • 0.31 MB
NIT18-2022-23.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .