Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹20.7 L+₹86,735 (4.36%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹21.5 L+₹1.6 L (8.19%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹22.8 L+₹2.9 L (14.7%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹23.5 L+₹3.6 L (18.1%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
11 Dec 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR REPLACEMENT MAINT REROUTING OF CI DI GI DISTRIBUTION SYSTEM INCLUDING CONNECTING ITEMS AT 200 DUs OTM I SHANKAR VIHAR OTM II III 180 Ors AND BANA SINGH ENCLAVE AREA OF AGE U WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2020_MES_394203_1
GE/WS/D-128 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹45,000
Yes
19 Jan 2021
10 Nov 2020
14 Dec 2020
10 Nov 2020
11 Dec 2020
28 Nov 2020
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and as directed.
Excavation in trenches by cutting of road crossing PCC hard standing for taking out/laying of pipe including making good the existing surfaces with same finish to match the original finish complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as directed.
Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed.
Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and as directed.
Taking up GI Pipe water mains 80 mm bore including all fittings and supplying, laying, Jointing, testing and commissioning of DI Pipe of 100 mm bore as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including tyton joint ( Rubber gasket joint) complete all as specified and as directed.
Taking up or down Cast Iron/Ductile Iron (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead complete all as specified and as directed of the following sizes
150 mm bore
200 mm bore
300 mm bore
Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS 8329-2000, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including tyton joint(Rubber gasket joint) complete all as specified and as directed site for the following sizes :-
150 mm bore
200 mm bore
300 mm bore
Material and Labour for CI/DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 1538-1993 complete all as specified and as directed.
Upto 150 mm bore
200 to 300 mm bore
Material & Labour for run lead joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed.
150 mm bore
200 mm bore
300 mm bore
Supplying , laying , jointing, welding & testing MS Pipe, Heavy class 'C' of followiing sizes as per IS 1239-2004 Laid in trenches or laying on floors for connections to centrifugal pump sets for suction, to header and to connected out going water main CI/DI pipe line, for following size including taking down the u/s one and deoposited to MES Store yard all as directed. Note:- MS Flanges and flanged joints complete with jointing material shall be measured and paid separately.
80 mm bore
100 mm bore
150 mm bore
Supplying and fixing, MS flanges of 80 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed.
Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed.
Supplying and fixing, MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and as directed.
M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of following sizes complete all as specified and as directed.
80 mm bore
100 mm bore
150 mm bore
Supply, fixing, jointing & testing Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846-2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
400 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312-(Part I) - 1984, flanged ends pressure rating PN 1.0 complete including taking out unsv NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
250 mm bore
Supply and fixing CI foot valve rating PN 0.2 flanged ends, swing type opration with rubber sheet, as per IS:4038-1986 including taking out unsv foot valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm bore
100 mm bore
150 mm bore
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
100 mm bore
150 mm bore
400 mm bore
Taking up or down GI steel tubing of following sizes with connections from Trenches/floors/walls complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Laying only GI pipe medium grade IS 1239 (Part I)-2004 marked including all fittings laid in trenches/wall/floor etc in old/new position complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supplying & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778-1984 of following sizes including taking out unsv gate valves complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Labour for cutting of CI /DI/GI/MS pipe in position for reducing to required length for insertion of new tees, branches etc of 100 to 250 mm bore complete all as specified and as directed.
Taking out sluice valve, foot valve, refacing, regrinding, rubber gasket changes, stem nut & bolts and refixing the same serviceable condition with flange joints including nut, bolt and double washers including painting of following sizes complete all as specified and as directed.
100 mm bore
150 mm bore
Supply, installation and testing flanged ends strainer/dirt box rating PN 10 of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv strainer/dirt box complete all as specified and as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
100 mm bore
150 mm bore
200 mm bore
400 mm bore
Material and labour for Fabrication, welding and fixing of MS work made out of MS sheet not more than 3 mm thick of any size or MS angle/flat of any size as required at site for repair/replacement of valve pit cover / Sump manhole cover, stair case steps, sign board and all other iron works including painting two coats with synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed.
Labour Only for run lead joint by using old lead and new spurn yarn for CI/DI Pipe of following sizes complete all as specified and as directed.
100 mm bore
150 mm bore
200 mm bore
300 mm bore
An amount of Rs 254398.00 shall be deducted from BOQ on account of schedule of credit
DHAIRYAE ENTERPRISES
P S TRADERS
RISHU CONSTRUCTION COMPANY
V.K. Enterprises
Vijay Electricals
Ridhi engineers and builders
Microsys Controls India
somyaenterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .