Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹44.3 L
Closing Date
6 Nov 2023, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Ranchi.
Balance Civil work and Additional work (MGPS, Furniture, MOT, Nurse call System, CSSd etc) for to be made-fully Operational of Regional Institute of Ophthalmology at RIMS, Ranchi
2023_JSBCC_76803_1
JSBCCL/78/2023-24
Open Tender
Civil Works - Buildings
365 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹44.3 L
JSBCCL
1 Feb 2024
9 Oct 2023
8 Nov 2023
9 Oct 2023
6 Nov 2023
9 Oct 2023
16 Oct 2023
Amount
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40mm nominal size.)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
Water bond macadam Providing, laying spreading & compacting stone aggregates of specific size to water bond macadam specification including spreading in uniform thickness hand packing, rolling with vibratory roller 8-10 tone / smothery wheeled steel roller in stages to proper gate & chamber, applying and booming requisite type of screening / binding materials to fill up the interstices of course aggregate, water and compacting to the required density.
(B) By mechanical means (b) Using screening Type - A (13.2mm Agg.) with vibratory roller
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All work above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
lintels, beams, plinth beams. girders. bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Suspended floors, roofs, landings, balconies and access platform. With 12mm waterproof ply
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. includIng cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (Plan area to be measured).
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 10mm,28/32mm dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing Tor steel reinforcement of 12/16mm. & 20/25mm. dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL))
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with flyash lime brick (FLAG) in (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of Ell.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :Rectangular or square.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 sqm and upto 16.80 sqm in the area.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete :125 mm
Providing & Fixing pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =300mm, 22mm dia, -SS304
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.Polyester Powder coated minimum thickness 50 micron aluminium tubular handle bar.
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin- charge complete.205 X 19 mm
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
Providing and fixing of fire rated heavy duty door closer tested in accordance with BS:476 Part 22 for fire rating) and BS EN 1154 with minimum one year warranty.
Providing and fixing fire rated mortice lock with lever handle tested in accordance with European Standard EN12209 / DIN18251 and 80mm Long cylinder to EN1303 of approved brand and manufacturer having min. 1 year manufacturers warranty.
Providing and fixing Lead Lined door of the Frame for the doors is second class teak wood ( ivory Coast) properly seasoned wood of section 100*60 mm with a coat of Viper make primer and paint. 44 mm thick Doors shutter are made out of 34 mm thick BWP grade Board , door shutter sandwiching 2 mm thick lead sheet for radiation control , 6 mm thick commercial ply and 1 mm thick laminate in suede finish on both the faces of shutters. Lead lining to be done for frame and shutter both with 2 mm thick lead sheet for control of radiations. The frames are fitted in masonary opening with the help of anchor Fasteners of Hilti /Fischer make of size 10*100/ 10*120 mm. Hardware for the doors are inclusive and includes-Stainless steel SS ball bearing hinges 100*75*3 mm of Becker of equivalent make, Dead lock with both side key operation of Becker or equivalent make , Back to Back D handles of size 19*300 mm stainless steel grade of Becker or equivalent make , Face mounted Tower bolt 300 mm long of Becker or equivalent make, Face mounted door closer of Becker or equivalent make, all work is being carried out under the directions of engineer incharge.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete asper direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid n basic item):
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.n gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and Laying 25 mm thick Kota stone ,slab flooring of approved size,texture and colour over 19mm. Thick base of lime mortar(1:1:1)(lime putty :surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolitjic finish with approved quality of carborandum stone including cost of curing, taxes and royality all complete as per building specification and direction of E/I-(iv) 600X600 MM SIZE
providing and laying 25 mm , thick lota stone tiles in risers of steps,skirting and pillars of approve size,texutre and colour laid over 12mm thick cement mortar (1:3)and joined with grey cement slurry mixed with pigment to match the shade of the including rubing to granolithic finish with approved quality
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels
Granite of any colour and shade Area of slab upto 0.50 sqm
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/SQM including pointing in white cement complete.Granite of any colour and shade
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-Charge .
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) B. Using Concrete Batching and Mixing Plant
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Providing and laying of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge.
Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing & Fixing flexible Conductive PVC sheet flooring of having a total thickness of 2mm and weight of 3kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REACH Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Equivalent to Armstrong PASTELL. Installation:It is important to ensure the sub floor on which the sheet is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be leveled by self leveling compound. The moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Providing & fixing Stonewool Acotsical Ceiling PACIFIC High NRC (0.80), Fire Rating A1 (EN 13501-1), RH 100% (No visible deflection in high humidity), Superior Class Light Reflection, Sag Resistant 12mm thick Ceiling Tiles of size 600x600 A-Edge (Square) with AntiBacterial Properties & M1 Class Emission Certification made up with Natural Stone (Bassalt Rock) a complete Green Product & perfect suitable for any kind of False Ceiling application in builiding & costruction. The Visible side is a smooth white painted fleece, the Rear side: back fleece with complete facctory finish Painted edges.
Providing & fixing of 10mm 4 Layer Polycarbonate Sheet I.Q Relax Makrolon Brand Sheet with Ug 2.5/SQMk, Opel White colour 50 Micron U.V. Coated & fixing with standard 60mm AluminiumProfileAlcox top & bottom section as per Drawing ( weight 1.1kg per RMT, minimum ) including EPDM Rubber Gasket for tiet sealing of aluminium section With end profile of aluminium and silicon sealant (Winsil 20 neutral grade ) as per drawing at site
Supply & Installation of 22mm thick multicell and multi-layered flux standing seam UV protected polycarbonate panel system along with standard fixing accessories as per direction of the engineer in charge. Panel shall be of min 22mm thickness in multicell truss bridge structure for more flexibility and better load bearing capacity. The entire panel shall be coextruded UV protected and block 99% UV rays. Panels shall have minimum six - seven layers. Panels with more layers will be preferred to control deflection due to snow load. Panels shall be a combination of translucent and opaque louvers integrated in clear body for angular day lighting and best diffused daylight in single long length to avoid any transverse joint in approved colours as per required lux level and design requirements. Panels shall be with all standard fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam and shall be fixed on Purlin (will be paid separately) with double tooth locking mechanism with SS HD Trapezoidal Fastener and big snap on connectors with a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. The Panels width shall be of 1000-1200mm (min) and panels with more width will be preferred to minimize panel junctions. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.7 W/m2K as per EN ISO 10077-2:2018. Flux panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: White louvers with clear body .
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing & fixing Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
Providing of two coats of plastic emulsion paint of approved shade and make over a coatof cement primer over a new surface including preparation of plasterd surface by rubbing smooth with pumice stone or fine sand paper apply putty wherever required and scafold do
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying Primer one cot red lead paint+syntetic enamel paint
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coat applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Supplying and laying Indoor Anti-Bacterial paint over gypsum ceiling and as specified by EIC, equipped with Silver Ion Technology which kills 99% of infection-causing bacteria on the painted surfaces and providing a more hygienic environment. VOC (ASTM D 6886): < 50 gm/lit Does not contain carcinogens, mutagens, or reproductive toxins. Any trace contaminants should be less than 0.01% by weight. Certified by Indian Medical Association or any other competent organisation. (including putty, primer and other accessories) Make : Asian Paints or equivalent
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : v) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.vi) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.vii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. viii) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat For the purpose of measurernent tte entire treated surface will be measured."
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.
The Watqrproofing Brand:*Sil<a Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :Using rough Kota stone
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design windpressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.
This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6 mm insulated glass (single glazed) vision panel units of size and shape as required and specified, Heat strengthned clear float glass 6mm thick,, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.For payment, only the actual area of glass . panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2 The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.
The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing in position about 50mm thick border and 35mm thick design Jali at all levels made from Glass fibre reinforced concrete (GFRC) using white cement, Quartz Sand, AR Fibres, Water Plasticizers & pigments in approved shape, size and length as per the design and drawings and as per specifications, mix design and test results given below. The typical Screen should be of sizes as per the drawings. Fixing of GRC Jali shall be with help of S.S. Screws Fixtures, M.S Angle Cleats, Fissure Plug, and Dowel Pin proper alignment as per drawings (Shop drawings to be Submitted by the contractor before the work start). As per approved paint, shade & Finishing with GRC powder & filling the joints with Epoxy sealant neatly between GRC screen and primary structures. The Screen should be in absolute straight plumb line and length and joins between channels should be neatly filed to make seamless uniform surface across the entire elevation of the building without any visibility to joints. Any framework to be paid extra as per item.(GRC Screen)
CARRAIGE OF MATERIALS
Sand ( 35KM )
Chips ( 22 KM )
Metal ( 22 KM )
Bricks ( 7+1 KM )
HORTICULTURE WORK
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of IS designation 20 mm
Screened through sieve of IS designation 16 mm
Screened through sieve of IS designation 4.75 mm
Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment)
PREPARATION WORKS
Fine dressing of the ground
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m diameter and 1.2 m deep
Holes 90 cm diameter and 90 cm deep
Holes 60 cm diameter and 60 cm deep
Holes 45 cm diameter and 45 cm deep
EVERGREEN TREE
Azadirachta Indica ,Neem
Alstonia scholaris ,Devil tree
Ficus benjamina, weeping fig
FLOWERING TREE
Bauhinia purpurea,,Kachnar
Callistemon lanceolatus,Bottle brush
Delonix regia,Gulmohar
Cassia fistula,Golden shower
Plumeria alba,white champa
Plumeria rubra,pink champa
foxtail palm
BAMBOO
Buddha belly bamboo
SHRUBS
Clerodendrum inerme,Volkameria inermis
Ficus panda
Ficus benjamina Starlight,Ficus Starlight
Gardenia jasminoides
Golden duranta
Hamelia patens
Hibiscus rosa-sinensis,udhul
Raphis excelsa,lady palm
Tecoma gaudichaudi,Yellow bells
TMC dwarf,Chandani
GROUND COVERS
Alternanthera red
Chlorophytum comosum
Jatropha
Sprenger's asparagus,Foxtail fern
Syngonium podophyllum,Syngonium butterfly
Tradescantia pallida
GRASS
Cynodon dactylon
PLUMBING WORK
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
(ii) E.W.C. with 'S' trap
(b) 10 lit. low level PVC Cistem
Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I.
(A) 580 mm. long
(c) With 10 lit. low level PVC Cistem
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I. (i) Kitchen sink 600 mm x 450 mm x 250 mm
(b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.
(i) 600mm x 450mm size
(c) (i) C.P. brass towel rail 20mm x600mm with bracket container
(c)(iii) C.P. brass liquid soap container
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Provinding and fixing wash basin wih C.I brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required : White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer
Providing and fixing white vitreous china laboratory sink with CI brackets , C.P brass chain with rubber plug 40 mm C.P brass waste and 40 mm CP brass trap with necessary C.P brass unions complete including painting of fittings and brackets , cutting and making good the wall wherever required : Size 600x450x200 mm
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in charge.
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 32mm Dia
Providing and fixing toilet paper holder : C.P. brass
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing N.P/C.P. brass /P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of Engineer - in -Charge. (a) 150mm dia P.V.C shower
DRAINAGE WORK
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround 100mm dia. SW / CI / waste pipes including bed concrete as per standard design
WATER SUPPLY WORK
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace)
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
Making connection of GI distribution branch with GI main of 50-80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete.
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
20mm nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50mm nominal bore
65mm nominal bore
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
20 mm dia, nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
80 mm dia, nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete.
20mm nominal bore
25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
65mm nominal bore
80mm nominal bore
Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes &fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.)
15mm nominal outer dia. Pipes.
20mm nominal outer dia. Pipes.
25mm nominal outer dia. Pipes.
32mm nominal outer dia. Pipes.
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50mm diameter
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks
EXTERNAL WATER SUPPLY
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore
50 mm dia.
65 mm dia.
80 mm dia.
100 mm dia.
Providing & Fixing of Garden hydrant outlet consisting 1 No. 25mm dia. Ball valve,( Brass) for connecting rubber hose, pipes & fittings.
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)
20mm nominal bore
25 mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50mm nominal bore
65mm nominal bore
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified .
50 mm dia
65 mm dia
80 mm dia.
100 mm dia.
150 mm dia
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified.
50 mm dia
65mm dia.
80 mm dia.
EXTERNAL SEWERAGE & DRAINAGE INSTALLATIONS UPTO MAIN ROAD FIRST MANHOLE
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
150 mm diameter
200 mm diameter
250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
150 mm diameter S.W. pipe
200 mm diameter S.W. pipe
250 mm diameter S.W. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :
150 mm diameter S.W. pipe / RCC pipe
200 mm diameter S.W. pipe / RCC pipe
250 mm diameter S.W. pipe / RCC pipe
300 mm diameter S.W. pipe / RCC pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
180 x 150mm size P-type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
450 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD - 20 Circular shape 560 mm internal diameter
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
For pipes 350 to 450 mm diameter
Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
TUBEWELL
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge.
Ordinary Rock
Hard Rock(requiring blasting)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Butterfly valve (manual) with C.I body SS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia.
Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 80 mm dia.
RAIN WATER HARVESTING
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves,chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing & reinforcement with1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
Centring and shuttering including stutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and acees platform
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia steel bar conforming to IS :1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and heaving manufactures permanent identification mark to be visible even after fixing " including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6: (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size )complete as per design.
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. HD-20 circular shape 560 mm internal diameter.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and fixing CP brass single lever low flow Sink mixer with 15 mm CP brass single lever pillar cock with pop up and waste complete including cutting and making good the walls where required.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required.
Providing & Fixing of Grab Bar size 300mm long in handicap toilet complete as required.
Providing,Fixing satin finish stainless steel AISI 316 grade wall mounted coat hook on door complete. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.
Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required.
Capacity 25 litres
Capacity 35 litres
Supply, installation, testing and commissioning built with Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, drinking water cooler (High quality SS Tank for Storage 80 lts) , complete in all respects.
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint. (soil waste and rain water pipe)
75 mm diameter pipe
100 mm diameter pipe
160 mm diameter pipe
Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors. 110 mm (OD) x 110 mm (OD)
Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to trap/waste pipe, complete of outer dia. (Indirect waste) 40 mm diameter pipe
Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD
Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 75 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect.
Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects.
110 mm dia
65 mm dia, nominal bore
80 mm dia, nominal bore
Providing and fixing Bronze compact(Screwed) Diaphram type pressure reducing valve (PRV) with strainer deliverying desired rate of flow. The complete system is tested to a pressure not less than 16 Kg / Sq.cm and suitable to reduce the pressure upto 1 Kg/Sq.cm) including flanges / unions, nuts, bolts and washers complete as required.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Providing and fixing M.S fabricated hot dipped galvanized coating puddle flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to 50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of required size including cutting holes in centre of plate, inserting pipe & making welded (Arc) joint complete. Same shall be installed with TEC welded joint in position with reinforcement bars of RCC tank wall/slab including making cutout in shuttering during concrete casting of tank of following diameter. (Under Ground Overhead Tanks.)
50mm dia pipe, 600mm long with size of 300x300x6 mm MS plate
65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate
80mm dia pipe, 600mm long with size of 400x400x6 mm MS plate
150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate
Providing, Fixing, Testing & Commissioning of nitrle rubber insulation on hot water supply pipes. K-Flex, A-Flex, Armacell. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.
15mm (9 mm thickness)
20mm (9 mm thickness)
25mm dia (9 mm thickness)
32mm dia (13 mm thickness)
40mm dia (13 mm thickness)
50mm dia (13 mm thickness)
65mm dia (19 mm thickness)
Solar Water Heating System-500 LPD (Location Terrace OPHTHAL BLOCK)
Providing and fixing Solar Hot Water indirect Heating System using heating liquid medium comprising of flat plate solar panels, including all interconnecting insulated G.I. piping, primary and secondary recirculation pumps, pressure type insulated hot water tank, , outlet, Y stainer and a water meter on the inlet, air release valve all mounted on galvanized MS sections complete with connection with the existing piping. Comparising of following:-(location Terrace)
Five Nos of. flat plate solar collector panels of 8 Sqm size approx. the panels enclosed in insulated collector boxes with single piece toughned glass 4 mm thick and fixed with heat resistant gasket.
One No. Integrated heat exchanger with drain down vessel 9 Ltrs. Capacity,designed so as to provide heat exchange between solar collectors and 500 ltr tank complete with drain down tank. The cold water heated after passing through heat exchanger to be stored in hot water tank. Necessary pumps and controller for automatic operations to be provided. including MS painted frames for the same.
M.S Horizontal hot water mixing tank of 500 ltr capacty shall be made out by of 4mm thick M.S. plate and inside lining of 1.0 mm thick stainless steel grade 316 sheet , out side steel primer including 50 mm thick rock wool slab insulation (density of glass wool 64 Kg/Sqm.) & 24 SWG aluminum sheet cladding outside the tank. Tank shall be provided with flanges for inlet outlet, over flow/ drain connection & Vent pipe with M H cover of 450 mm internal dia., Temperature and pressure release valve should be on top of water storage tank All the valve & accessories shall be suitable for an operating pressure of 6.0 kg/sqm including electric back up of 1 x 4.5 KW
Primary circulation pump 2 Nos (1W+1S) for circulation of fluid from Solar panels to heat exchanger.
Secondary circulation pump 2 Nos (1W+1S) for circulation of fluid from heat exchanger to hot water mixing tank.
One Lot of Inter-connected insulated G.I. piping insulated with 9 mm thick nitrile rubber heat resitant insulation sections ( Vidoflex or equiv.) and valves with outer mechanical protection of aluminium sheet cladding.
Solar Water Heating System as Describe Above
Supply , instalation, testing & commissioning of Cubical type branch distribution boards( BDB) of the following types made out of 14 gauge (2 mm thick) CRCA sheet complete with the accessories i/e. interconnections with suitable copper solid strip connections 100 A & above and with copper wires below, painting etc. and complete with supplying & fixing the following boardsetc. as required.
Branch Distribution Board for 500 LPD System
1 No. 125 AMP rating TP Modulded case circuit breakers with neutral link, front operated handle & thermal magneticrelease (35 Ka)
1 Set 125 Amp 4 Bars Tinned Cu. Bus Bar
1 Set LED type Indication lights
1 No. Digital Voltameter (0-500 V)
1 No. Digital Ammeter (0-125 A )
1 Set CTs for Ammeter 125/5 A ratio
3 Nos. 2 A SPMCB
Outgoing
08 Nos 25 A TP MCB , 10 KA (6+2 Spare)
03 Nos 63 A TP MCB , 20 KA for Electric back up supply.
The System is based on temprature difference and the system will operate automatically based on thermostat for startup and shutdown of Primary,Secondry, Receiculation pump and Heating elements on temprature differential.
Electric Panel as Describe Above.
HOT WATER GENERATION SYSTEM (OPHTHAL BLOCK)
Supply, installion, testing and commissioning of Hot Water Generation Plant with Packaged type Air to Water Heat Pump. These units shall be completely factory assembled including 2 Nos. Scroll Hermatically Sealed Scroll Compressor(s), evaporator, Condenser and Microprocessor Control Panel etc with R410 Referigerant and COP between 3-4. The Heat Pump shall have inbuilt hot water heat exchanger, pumps, valves. expansion valve, integrated CIP system and other accessories.The Heat Pump should be capable of producing hot water at minimum 60°C temperaure at outlet (condenser circuit) temperatures at 10°C ∆T. The Machine should have an operating ambient temperature range of 5°C to 40°C. Location: Terrace Level
a. Built in electric panel as per safety norms as manufacturer standard.
b. All other mountings, fittings & controls with all accessories and safeties
c. All other mounting, fittings and controls.
d. Suitable for electric supply of 415 + 10% volts & 50 Hz.
e. All interconnecting wiring / cabling between heat pump and electrical panel.
f. The Heat pump shall have an in-built facility to start / stop depending on variation in demand at different periods.
g. System shall be complete with SS 304 Tank of 2 Hrs Storage Capacity, Primary and Seconary Circualtion pumps, Heat Exchangers, Return Recirculation Pump, interconnecting piping, valves and all accessories as required.
h. System shall have 20% of total capacity in electrical heating as standby.
i. System shall have an integrated Solar Heating system with 20% of total capacity for energy saving including Flat Plate Solar Panels, Mixing Tanks, Recirculation Pumps, etc
following capacity required for block wise specification as same for all Heat pump.
For OPHTHAL BLOCK
Heating capacity : Approx. 200 KW (100 KW x 2 working + 0 standby)
SS 304 Hot Water Storage Tank : 5000 Ltrs x 1 Nos
Solar Water Heating 20% - 52 Flat Plate Collector with 1000 Lit tank with coil
Reverse Osmosis Plant (RO) Hospital Block- suitable for 10 hrs operation including filter feed pumps,multigrade sand filter, activated carbon filter, antiscalant dosing, acid dosing, micron cartridge filter, RO high pressure pumps, RO moules, RO Cleaning System, valves, interconnected piping and accessories.
Expected Treated water characteristics after RO Treatment
Total dissolved Solids - < 50 ppm
Suspended Solids - NIL
Turbidity - As per IS:10500
Iron as Fe - NIL
Total Harness - Less Than 5 ppm
Permeate water quantity = 500 lit/hr. described above (a) to (m).
following capacity required for block wise specification as same for all Heat pump.
500 LPH RO FOR OPHTHAL BLOCK)
HYDRO-PNEUMATIC SYSTEM (OPHTHAL BLOCK)
Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System (Variable Speed) As Follows:
a. Vertical, In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal)
(Vendor to submit performance curves and technical catalog of the proposed model for review & information)
b. External Pump mounted or wall mounted microprocessor PID controller(VFD) and frequency inverter integrated in a single body or as separate components with pressure sensor transmitter minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocall through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equiped with dry running protection
Quantity : 1 No.
c. Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor)
d. Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete.
e. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete.
f. Accessories like pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer)
g. GI suction and delivery header with flanges for inlet connection, common outlet header with flanges for outlet connections as required, and interconnecting piping with flexible connections, eccentric type reducers etc. all necessary indigenous accessories as required to complete the installation. Sluice valves at inlet and butterfly valves at outlet, strainer at inlet and NRV at outlet of all pumps shall be provided.
Note:Contractor to note that the suction header is required to have inlet connection from the Puddle Flange @ water tanks and to the pump suction. Provision of delivery header is required to have outlet connection from the pumps. Suitable outlet flanges from the delivery mainfold / header shall be provided as required.
Domestic Booster system for Hospital at terrace as follows:
No. of pumps (2 Working + 1 Standby)
Water Flow Rate - 300 LPM Each
Head - 30 M
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of 10Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe including bed concrete and thrust blocks at bends as per standard design.
Supply, Installation, Testing & Commissioning of Single stage, High Speed, Horizontal centrifugal monobloc pumping set with SS 304 impeller, SS 316 shaft and C.I. Base & head, mechanical seal, connected to a TEFC induction motor suitable for 400/440 volts, 3 phase 50 cycles A.C. supply with vibration eliminating pads as required, M.S fabricated base plate bolted to cement concrete foundations complete with level controller level switches & control wiring.
Domestic Water lifting pumps :
Flow Rate/Capacity - 90 LPM
Pumping Head - 40 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 2 HP or as per manufacturer recommendation.
Location - UGH Pump Room
Supplying, installing, testing and commissioning of SS vertical centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia). The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries, starter panel / control panel & accessories including base plate complete as required.
The entire Hydropneumatic system shall be factory fitted.
Filter feed pump
Flow rate : 175.0 LPM each
Pumping Head - 35 m
1 Set = 2 Nos. pump (1 working+1 standby)
Approx H.P. - 2.5 HP or as per manufacturer recommendation.
Providing, fixing, testing & commissioning of vertical MSEP filter with adequate dirt holding capacity. Fabricated from FRP sheet as per IS-2825 and manufacturer's specifications complete with intitial charge filter media including painting inside with two coats of non toxic epoxy and with one coat of zinc chromate two coats of synthetic enamel paint outside. Including concrete foudation with cement plaster complete as required. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (heavy) . it is designed on 1.50 m / sec velocity.
Dual Media Filter For Domestic Water Supply
Capacity- 10500 LPH
Filtration rate- 6000 LPH/Sqm.
Filter dia approx. - 1300 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Activated Carbon Filter For Domestic Water Supply
Capacity- 10500 LPH
Filtration rate- 6000 LPH/Sqm.
Filter dia approx. - 1300 MM
Working pressure: 3.0 Kg/sq cm.
Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 100 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-6 lph, complete in all respects. Chlorination of Domestic Water
Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top or bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position.
Electric Panel For Water Supply Pumps at Water Supply Pump Room
INCOMING
1 No. 63 amps TPN MCCB with the following accessories:
1 No. square flush mounting 0-500 volts scaled voltmeter with three way and OFF switch.
Three phase indicating lights.
Electrolytic high conductivity three phase and neutral tinned copper bus bar rated at 100 amps having a current density of 1 amp per Sqmm suitable to with stand symmetrical fault level of 25 MVA at 415 volts. The neutral bus bar is to be of 100% capacity.
OUTGOING UNITS
Ten 25/40 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
Two 63 Amp. TP + NL M.C.C.B. with rotary handle of breaking capacity 25KA
8 Nos. fully automatic DOL starters with push buttons and ON/OFF indicating lights and overload relays for 1.5 to 7.5 HP pump .
6 Nos.cyclic relay for automatic duty changeover of pumps.
8 No. single phase preventors.
Space for 3 Nos. Level Controllers.
Switchgear shall be suitable for the HPS of various motors.
1 Nos. 63 Amp. TPN MCB Spare.
2 Nos. 32/40 Amp. TPN MCB Spare.
The motor control panel shall be prewired with colour coded wires with identification labels complete in all respects as required.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to probes of required.
Level Controller For Water Supply Pump: To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
Level Controller For Sump Pumps: To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 16 Kg/Sqcm.
50 mm dia
65 mm dia
80 mm dia
Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings.
Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase.
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Sewage Treatment Plant 50 KLD
Note : All Civil Works with Structural Walk Ways/ Railings, General Lighting and Ventilation to be Done by Client/Owner.
Sewage Treatment Plant: - Designing, Supply, installation, Testing and commissioning of complete mechanical and electrical Items with stand by pumps as mentioned in the List of Mechanical equipment’s of the STP-50 KLD based on MBBR technology. (Excluding civil works). List of Electro-Mechanical Equipments: - Bar Screen - 2 nos, Level Switch - 1 set, Sewage lifting pump - 2 nos, Plant Room Sump Pump - 2 nos, Air Blower - 2 nos, Air dispersion system - Fine bubble diffuser - 1 Lot, corse bubble diffuser - 2 Lot, Air piping - 2 Lot, Sludge recirculation pump - 2 nos, Filter press (Manual) - 1 nos, Screw pump - 2 nos, MBBR media - 1 Lot, Tube settler media - 1 Lot, Filter feed pump - 2 nos, ALL CIVIL WORK (Client scope) ;- Screen cum Oil & grease chamber - 1 nos, Oil & Grease chamber - 1 nos, Collection Tank - 1 nos, Plant Room - 1 nos, Foundation for equipment - 1 nos.
INLET SEWAGE CHARACTERSTICS (ASSUMED)
BOD5 : 250 - 350 mg/lit
Total Suspended Solids (TSS) : 250 - 450 mg/lit
COD : 500 - 700 mg/lit
Oil / Grease : upto 50 mg/lit
Inflow time : 24 HRS
Peak factor : 3
Temperature : Ambient
Desired Sewage Quality After Treatment
BOD5 : < 10 mg/lit
Total Suspended Solids (TSS) : < 10 mg/lit
COD : < 50 mg/lit
Oil / Grease : < 5 mg/lit
Colour : Colourless
Odor : unobjectionable
E.coli : Nil
NH4-N :< 5 mg/lit
N Total :< 10 mg/lit
PO4-P : 2 mg/lit
Vendor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.
Effluent Treatment Plant 10 KLD (OPTHALOMOGY BLOCK )
Design, Supplying, installing, testing & commissioning of Effluent Treatment Plant of 10 KLD (excluding excavation, back filling & disposal of surplus earth and Civil construction work) for the following duty: (OPTHALOMOGY BLOCK)
Effluent from OT Scrubs, blood bank, labs etc. Some solvent/ chemical waste originating typically from hospital complex shall also be discharged into the ETP. Design to take consideration of same.
INLET EFFLUENT CHARACTERSTICS
BOD : 250 - 600 mg/l
S. Solids : 200 - 650 Mg/l
COD : 600 - 1200 mg/l
Oil & Grease : 50-140 mg/L
Effluent discharge standard after treatment
BOD - Less than 150 Mg/L
S. Solids - Less than or equal to 100 Mg/L
COD - Less than or equal to 300 Mg/L
Oil & Grease - Less than 5 Mg/L
Effluent treatment plant shall include the following items:
Screen Chamber
Equalization tank/sump
Primary Tube Settler
Dosing System
Sludge Holding Tank
UV System
Air Blowers, Pumps & equipment
Piping, valves etc
Clarified Water tank
Electrical Panel & Cabling
Contractor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.
FIRE FIGHTING WORKS
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor)
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Upright Sprinkler
Horizontal side wall sprinkler
Concealed sprinkler
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )
Providing and Fixing of CO2 Portable 4.5 Kg Fire extinguisher, Carbon-Dioxide type Flat base Horn Including Valve, High Pressure Rubber Wire Braided Discharge Hose of not less than 10 mm dia. & complete in all respects including initial fill with CO2 Gas confirming to IS:15222. and IS 15683:2018 Marked. Location : Inside FHC, Parking Area, Electrical Room, Pump Room,
Supply & Fixing of 6 Kg ABC MAP-50% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2018 Marked. Location : Open General Area, Inside FHC, Parking Area,
Supply & Fixing of 9 Kg ABC MAP-50% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2018 Marked. Location : Open General Area, Inside FHC, Parking Area, Basement
Providing and Fixing of Portable 4kg Clean Agent HFC-236fa Fire Extinguisher, Gas UL Listed under EPA SNAP, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), Suitable for Class A,B and C & Electrically Started Fires, Conforming to IS 15683:2018 Marked. Location : General Office Area, Inside of Critical Rooms i.e. Server Room, UPS Near Rooms, Fire Control Room etc.
Providing, fixing of 60 Ltr Mechanical Foam (AFFF-6%, Confirms to IS 4989 (Part-II), Trolley Mounted Fire Extinguishers, Fitted with 4 Metre EPDM Hose with SS Spring of 300mm & Air Aspirated Nozzle, CO2 Gas Cartridge of 300 Grams. Confirms to IS 4947, Brass Forged Cap, including all accessories complete in all respect. Applicable on Class A & B Fire, IS 16018:2012 Marked & CE Approved. Location : Near HSD Tank, DG Area
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc.
PUMPS
1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra.
2. All the Fire Fighting works shall be done in compliance of Fire Fighting authority requirement.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 55 m Head (For Hydrant & Sprinkler System).
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 55 m Head (For Hydrant & Sprinkler System).
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump).
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.
M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 55 m Head (For Hydrant & Sprinkler System).
CONTROL PANELS
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Incomings
400A, 50kA 4 Pole MCCB, Ics=100% Icu rating
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 500A
Outgoings
Main Fire Pump
Jockey Pump
Diesel Engine Control
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication
All standard relays and accessories for automatic operation of diesel engine
System Controller
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
Supplying,Installation,testing & commissioning of dust & vermin proof double door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCA sheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.
Incomming
63 Amps. TP & N SFC with HRC fuses
Set of 3 phase indication lamp
Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 x 25 sqmm ( 28 mm )
3.5 x 50 sqmm ( 35 mm )
3 X 10 sq. mm (22mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.
4 core, 25 sq.mm. Aluminium Armoured
3.5 core, 50 sq.mm. Aluminium Armoured
3 core, 10 sq.mm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.
PIPES & ACCESSORIES
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground )
200 mm. dia (wall thickness = 6.3 mm)
150 mm. Dia
100 mm. Dia
80 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor)
150 mm dia
200 mm dia (wall thickness 6.3 mm)
250 mm dia (wall thickness 6.3 mm)
300 mm dia (wall thickness 7.1 mm)
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
50mm dia
65mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65 mm dia
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe. (FOR UG TANK)
4 way - 150 mm dia M.S. Pipe. (FOR UG TANK & EXTERNAL RING MAIN)
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
100mm dia
150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
80mm dia
100mm dia
150mm dia
Providing, installation, testing & commissioning of electric release trim assembly for deluge wall with two way solelnoid valve, weather proof operation on 24 volts DC supply complete as required.
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge.
Pressure Vessel Supplying, installing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. Complete as per manufacturer's specifications & as directed by Engineer- in-charge. working pressure:- 11 kg/sqcm test pressure: 20 kg/sqcm (450 mm dia & 2000 mm height)
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.
150 mm dia
80 mm dia
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 25 mm Dia
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser.
Providing & fixing cast iron 100 mm dia. Foot valve with nuts, bolts, 1.5 mm thick CAF gasket complete with all accessories (To be provided into UG Fire Water Tanks).
Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with sand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge .
Providing, fixing water flow meter on test line complete with all accessories for flow indication , monitoring & testing of fire pumps with bypass arrangment including piping & bypass valves. 150 mm dia
HVAC WORK
ARI CERTIFIED WATER COOLED SCREW CHILLING MACHINE
Testing, Balancing and commissioning of Water Cooled Screw Chilling M/C with associated pumps (Primary & Secondary), air & Dirt separator, vacuum degreaser, Variable speed pumping system for secondary pump, condenser water pumps, colling tower, expansion tank, valve and piping system starting from Chiller To Last indoor units . The Unit shall be mounted IP 54 rated VFD Starter of suitable capacity. The chilling m/c as described above shall be in line with specifications & shall have interface card compatible with BMS system.
All Chiller shall be tested at 4 points at 100%, 75%, 50% and 25% at AHRI conditions at manufacturer test bed before dispatch.
Water flow switches at outlet of condenser & chiller, water drain, air purge valves, thermometers and pressure gauges wherever required.
Initial/first charge of refrigerant gas & compressor oil shall be factory charged. Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc.
Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. RCC / cement concrete foundation for the chilling unit.
ARI Certified Centrifugal Water Cooled Chilling Machine With Variable Speed Drive & Microprocessor Based Control Panel Of Capacity 175 TR (2W + 1S) The price quoted for supply, installation, testing & commissioning of Centrifugal Chilling Unit shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees.
HOT WATER GENERATOR
Supply, installation, testing and commissioning of Hot Water Generator With VFD for Monsoon Reheat of capacity 180 KW in three banks complete with controls, electrical panels etc. confirming to technical specifications Section.
Inlet Water Temperature 44.44 °C (112°F)
Outlet Water Temperature 54.44 °C (130°F)
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, port clearance charges etc. as required in Indian Rupees. (1W+1S)
HOT WATER PUMPS
Supply, installation, testing and commissioning of Monoblock hot water centrifugal pump sets with VFD.Pump Sets having bronze impeller for hot water recirculation complete with TEFC Sq. Cage induction motor with class "B" insulation, base plate, vibration isolators etc. conforming to techinical specification and as per following parameters. The hot water pumps shall include thermal insulation & cladding.
Capacity of Each Pump LPM -260
Pump Head (Mt) -35.0
Motor HP -5.0 HP
The price quoted for supply, installation, testing & commissioning shall be inclusive of all duties & taxes, insurance, transportation / shipment cost from works to site, loading / unloading, etc. as required in Indian Rupees. (1W+1S)
DUCTING,INSULATION,DAMPER, GRILLE & DIFFUSER
SHEET METAL DUCT ALUMINIUM (AL) Ducting For OT
Supply, fabrication, installation & testing of Aluminium sheet metal ducting duly polysulphide sealed complete with Splitter Damper, vanes etc. as required for OT and as per ISI specifications and as per approved shop drawings.
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
The joint between the ducts shall be done by means of polymer “flange / slide-in channel” system to prevent air leakages. Turning vanes, elbows and reducers to be considered as part of supply of ducts. Ducts shall be supported by cable supports / GI slotted channels with threaded rods. Internal Stiffeners shall be used to prevent bulging of ducts for the sizes above 800 mm.
0.80 MM (22 Gauge ) With 32mm Insulation
1.00 MM (20 Gauge ) With 32mm Insulation
1.25 MM (18 Gauge) With 32mm Insulation
Duct Insulation
Supply. Installation, testing and commissioning of insulation on the surface of the duct with duly laminated aluminum foil (26G) of mat finish closed cell nitrile rubber (Class 'O' ) with suitable adhesive, as per specifications and drawings. The Joints shall be sealed with 50mm wide and 3 mm thick self adhesive nitrile rubber tape Insulation. The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications.
AHU ROOM ACCOUSTIC LINING
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. 50 mm thick
Duct Acoustic Lining
Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents.
Slot Diffusers
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
Linear Grille
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.
Under Deck Insulation of Exposed Roof
Providing and Fixing Underdeck Insulation with 50 mm thick with closed cell Nitrile Rubber with prelaminated Aluminum foil on one side having a low stable k value of 0.035 k.cal/hr.m at 10.C and minimum density of 40-55 ± 3 kg/cum.The R-value should be as per ECBC Code. 50mm
AIR CONDITIONING EQUIPMENTS LOW SIDE HUMIDIFICATION PACKAGE
Supply, installation, testing and commissioning of Humidification package with all necessary controls as required as per standard specification & of following capacities:
LAMINAR AIR FLOW
Supply, installation & testing of factory fabricated Laminar air flow pattern perforated plenum made of 16 G aluminium sheet with hepa filters & suitable for operation theatre with all accessories as required to suit, site condition as per specifications.
SIZE-2.4mx2.7m
SIZE-2.4mx2.4m
AIR COOLED SPLIT TYPE SPLIT UNITS AIR-CONDITIONER
Supplying, installing, testing and commissioning of Air Cooled Invertor Split type wall mounted /Ceiling suspended 5 Star Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc.
Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness and cabling for all types of split AC units. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection.
Note: Providing and fixing of Powder coated M.S. angle iron frame work for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation.
Capacity : 1.5 TR (450 CFM)-Wall Mounted
Capacity : 2.0 TR (625 CFM)-Wall Mounted
SCHEDULED TIMER FOR SPLIT AC
Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.
VENTILATIONS EQUIPMENTS
AXIAL FLOW FANS (SMOKE EXTRACTION/EXHAUST FAN)
Supply, installation testing & commissioning of Fire Rated direct driven Axial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation Springs, back draft damper(wherever required), bird screen at one sides (entry for supply air and exit for exhaust air) and rated Motor with class-H insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply. with starter panel.
Fan and motor shall be fire rated to 250 Deg C for 2 hours or as indicated in the specifications
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS system of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
Capacity 2000 CFM, SP 15 mm wg
Capacity 3000 CFM, SP 15 mm wg
Capacity 4000 CFM, SP 20 mm wg
Capacity 6000 CFM, SP 20 mm wg
Capacity 7000 CFM, SP 20 mm wg
Capacity 10,000 CFM, SP 25 mm wg
Capacity 14,000 CFM, SP 30 mm wg
AXIAL FLOW FANS (SUPPLY/PRESSURISATION FAN)
Supply, installation testing & commissioning of direct driven Axial flow fan. Each fan shall be complete with casing made from mild steel duly enamel painted, adjustable pitch die cast aluminum impeller (HUB & BLADES), mounting clits, structural frame with blank-off sheet, anchor fastener with vibration isolation Springs, back draft damper (wherever required) bird screen at both sides and rated Motor with class-F insulation. Motor shall be suitable for 415+10% volts, 50 cycles , 3 phase AC supply with starter panel.
Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.
Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of Fire
1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second)
2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second)
3. Fan motor shall meet IE3 or above standard as per IS-12615
5. Thickness of casing : for dia( 315-630 )mm - 2mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm.
6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.
Capacity 2000 CFM, SP 15 mm wg
Capacity 3000 CFM, SP 15 mm wg
Capacity 4000 CFM, SP 20 mm wg
Capacity 6000 CFM, SP 20 mm wg
Capacity 7000 CFM, SP 20 mm wg
Capacity 10,000 CFM, SP 25 mm wg
Capacity 11,000 CFM, SP 25 mm wg
Capacity 14,000 CFM, SP 25 mm wg
INLINE FAN (Ceiling suspended)
Supply, installation, testing, commissioning of Inline fan with vibration isolators & speed regulator, complete as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power.
200 CFM with 10 mm static Pressure
300 CFM with 10 mm static Pressure
400 CFM with 10 mm static Pressure
500 CFM with 12 mm static Pressure
600 CFM with 12 mm static Pressure
700 CFM with 12 mm static Pressure
800 CFM with 12 mm static Pressure
900 CFM with 12 mm static Pressure
1000 CFM with 15 mm static Pressure
PROPELLER FAN:
Supply, installation, testing, commissioning of Wall mounted fan with gravity louvers, vibration isolators & speed regulator, complete as per specification and drawing.
AIR WASHER :
Supply, Installation, Testing & Commissioning of factory fabricated Double Skinned Air-washer unit floor mounted type fabricated out of extruded aluminum section with 0.8mm pre-plasticized /pre-coated Galvanized steel sheet outside & 0.8 mm plain Galvanized steel sheet inside with blower, blower section and blower motor TEFC type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply. Air washer having minimum 90% efficiency with consisting of centrifugal fan, mounting arrangements, mentalistic vibration isolation, belt drive arrangement, VCD, distribution headers, access door, pump, stainless steel water tank, suction screen, impregnated cellulose paper fills, nylon prefilter, GI ‘B’ class piping & associated works, quick fill, makeup & drain connections with butterfly & float valves etc. complete as per specifications & drawings. The unit shall be fire retardant, water proof double flexible connection at fan outlet and with starter panel.
Filters section shall incorporate synthetic washable filters of at least 50 mm thickness in suitable aluminum frame. Velocity of air across the fillers shall not exceed 500 fpm (2.5m/s).
12500 CFM with 50 mm static Pressure
DUCTING,INSULATION,DAMPER, GRILLE & DIFFUSER SHEET METAL DUCT
FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply. Installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts with flanges, inbuilt sealant, gasket, supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge) Plenum
SITE FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.
Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006
0.63 MM (24 Gauge )
0.80 MM (22 Gauge )
1.00 MM (20 Gauge )
1.25 MM (18 Gauge)
FIRE RATED FACTORY FABRICATED GALVANIZED STEE(GSS) SHEET METAL DUCTS
Supply. Installation, testing and commissioning of Fire rated sheet metal ducts shall be fabricated from Lock Forming Quality grade prime galvanized steel sheet with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Supporting distance shall not exceed 1.2 Mtr with 6mm thick fire retardant gasket suitable for 250 deg C 2 hr shall be used in duct joints along with fire sealants. Suitable access doors shall be provided at every 3m. The rates shall include all materials of the duct and labor for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications.
All fire rated duct, smoke exhaust ducts shall be quoted with flame bar BWII or equivalent to achieve the required fire rating, also all the related accessories gaskets shall be suitable for the required fire rating.
Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006
1.25 MM (18 Gauge) Plenum & Exhaust Duct
VOLUME CONTROL DAMPER
Supply. Installation, testing and commissioning of G.I construction Duct/ Volume control Dampers for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification.
MOTRIZED VOLUME CONTROL DAMPER
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room.
Motorized (ON-OFF Type) duct mounted GI volume control damper
Motorized (ON-OFF Type) duct mounted GI volume control Actuator
BACK DRAFT DAMPERS
Supply, Installation, testing and commissioning of 18 Gauge G.I construction Back draft Dampers for Controlling the recirculation of air with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum.
PRESSURE RELIEF DAMPERS
Supply,. Installation, testing and commissioning of 18 Gauge aluminum alloy extrusions with welded/cleated frames Pressure Relief Dampers for Controlling the Excess pressure up to 60pa with neoprene rubber gaskets,nuts, Bolts, Centrifugals Linkages, Flanges etc. as per specification. Louvres shall be made powder coated extruded aluminum with suitable thickness.
GRILLES AND DIFFUSERS
Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification.
Grilles with Dampers
Supply. Installation, testing and commissioning of powder coated extruded aluminum section grills with dampers for supply air terminal for air-conditioning as per specification.
Diffusers
Supply. Installation, testing and commissioning of powder coated extruded aluminum square diffusers with antismudge ring and removable core.
Supply air with dampers
Return air without damper
Flexible Duct
Supply. Installation, testing and commissioning of thermal flexible aluminum duct of following sizes duly supported at regular interval as per site requirement & spefications. 200 mm
Slot Diffusers
Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.
3-Slot Diffuser
2-Slot Diffuser
Linear Grille
Supply. Installation, testing and commissioning of powder coated extruded aluminum Linear Grille.
Exhaust/Fresh Air Louvers
Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminum construction with bird screen, minimum 80 mm deep.
Fire Damper with Spring and Fusible Link
Supplying, installation, testing and commissioning of Fusible Link type fire and smoke dampers of 18 gauge GI sheet construction suitable for 120 minute fire rating.
Fire Dampers & Actuator
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of at least 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor.
Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices up to 0.8 sq. meter with control panel & temperature sensor.
Fire Damper
Actuator
ISOLATOR FOR OUTDOOR UNIT
Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .
40A 4P MCCB(25 KA)
63A 4P MCCB(25 KA)
100A 4P MCCB(25 KA)
CUBICAL PANEL BOARD FOR HIGH SIDE EQUIPMENTS
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to various locations, handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-bolts, testing and commissioning of Totally Type Tested Panels (Form-4B construction) complying to IEC:61439 -1/2 cubical with Internal arc withstand of 50kA for 0.3 second and minimum impact resistance IK10 as per IEC:62262 with each compartment front unbreakable glazed door cover and back solid door. The degree of protection of minimum IP:42 for indoor and IP:65 for outdoor use. Panels shall be tested for an Impulse Withstand Voltage of 12kV. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system bolted fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plate, bottom base channel of MS section not less than 100mmx 50mmx50mmx 5mm thick for Main L.T. Panel and capacitor panels and 40mmx25mmx25mmx 5mm thick plates for MDB/MCC and SDBs etc.
Including cleaning & finishing complete, SMC bus bar supports, with short circuit withstand capacity of minimum 50kA for 1 Sec., fabrication shall be done in transportable sections and all front and back doors shall be hinged type and earth with frame, Entire panel shall have a common copper continuous earth bar of size 40mm x 6mm or as specified below at the rear with 2 Nos. earth stud each side, solid inter connections from main bus bar to switch gears up to cable alley with required size. bus bars and insulated control wiring with suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half, incl. providing following switch gears :-
Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provide fully automatic control thermostat with strip heater.
3# 175TR Water Cooled Centrifugal Chiller-3Nos (2 Working+1Stand by)
3# Primary Pumps ( 2W+1S)(15 HP EACH)
3# Secondary pumps (2W+1S) (25 HP EACH)
2# 180 kW Hot Water Generator(1w+1s)
2# Hot Water Pumps (1W+1S)(5.0 HP EACH)
3# CDW Pumps (2W+1S)(40 HP EACH)
5# 250TR Cooling Tower ( 2W+0S) (2 #7.5 HP each )
INCOMER
Incomers –3 Nos 1600 Amps 4P ACB 50 kA for O/C , S/C& E/F protection ,reverse power relay- trip & RS485 Port, cable connection on one side and Busbar connection on the other side.
INDICATING PANEL
Provide 1nos phase indicating lamps LED each backed up with fuse and switch.
Provide 1600/5a CT CI-1,15VA operated Digital Ammeter for all in-comers and outgoings including C/T's.
Two numbers indicating lamps LED on each incoming and outgoing feeder for indicating the status of feeder.
One number indicating lamp LED on each incoming and outgoing feeder for indicating that the feeder has tripped due to fault condition.
1 No. Power factor meter
1 No. Digital type energy meter.
Break Control Switch (T-N-C)
Control Fuse Base
BUS COUPLER
Incomers –1 Nos 1600 Amps 4P ACB 50 kA for O/C , S/C& E/F protection trip & RS485 Port, cable connection on one side and Busbar connection on the other side.
BUSBARS
Sections of 3Nos x 2000 Amps TPN bus bar chamber of suitable lengths with Aluminium bus bars. All bus bars and interconnections shall be of suitable size Al strips. Current density of Al shall not be more than 1.0 Amps/ sq.mm cross sectional area of Bus Bar
Incomer and 3Nos x1600 A EDO 4P ACB bus coupler shall be mechanically & electrically interlocked to avoid paralleling of the two supplies.
OUTGOING
3# 175TR Water Cooled Centrifugal Chiller-3Nos (2 Working+1Stand by)
800A 4P ACB of suitable rating with overload, short circuit protection, on /off /trip indication light with control MCB. MCCB Shall be 35 KA (ICU=ICS) SET - 06 ( Extra 2 Nos Spare=08 Nos )
3# Primary Pumps ( 2W+1S)(15 HP EACH)
3# Secondary pumps (2W+1S) (25 HP EACH)
2# 180 kW Hot Water Generator(1w+1s)
800A 4P ACB of suitable rating with overload, short circuit protection, on /off /trip indication light with control MCB. MCCB Shall be 35 KA (ICU=ICS) SET - 02 (1Nos Spare=01 Nos )
2# Hot Water Pumps (1W+1S)(5.0 HP EACH)
3# CDW Pumps (2W+1S)(40 HP EACH)
5# 250TR Cooling Tower ( 2W+0S) (2 #7.5 HP each )
POWER CABLING
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender.
A) Power cabling (XLPE insulated Aluminum / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc. as per specification.
Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment's (Indoor & Outdoor) shall be done by HVAC Contractor.
3.5 Cx 25 Sqmm Al Conductor
3.5 Cx 35 Sqmm Al Conductor
3.5 Cx 50 Sqmm Al Conductor
3.5 Cx 70 Sqmm Al Conductor
3.5 C x 95 Sq. mm Al Conductor
3.5 C x 120 Sq. mm Al Conductor
Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :
4C x 16 Sq. mm Copper Conductor (Armoured)
4C x 10 Sq. mm Copper Conductor (Armoured)
4C x 6 Sq. mm Copper Conductor (Armoured)
4C x 4 Sq. mm Copper Conductor (Armoured)
3C x 1.5 sq. mm Copper Conductor (unarmoured)
3C x 2.5 sq. mm Copper Conductor (unarmoured)
3C x 4 sq. mm Copper Conductor (unarmoured)
3C x 10 sq. mm Copper Conductor (Armoured)
3C x 16 sq. mm Copper Conductor (Armoured)
GI CABLE TRAY
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
EARTHING STRIP/WIRES
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply & laying 25x5mm GI strip at 0.5mt below ground as strip earth electrode including connection/terminating with GI nut,bolt,spring,washer etc. as required.)jointing shall be done by overlapping &with 2sets of brass nuts bolt spring washer spaced at 50mm) 25mm x5mm
II) All Equipment listed in BOQ shall be BMS Compatible.
ELECTRICAL WORK
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
CIRCUIT / SUBMAIN WIRING
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
2x10 sq mm + 1x6 sq mm earth wire.
2x16 sq mm + 1x6 sq mm earth wire.
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x6 sq mm + 2x6 sq mm earth wire.
4x10 sq mm + 2x6 sq mm earth wire.
4x16 sq mm + 2x6 sq mm earth wire.
Supplying and drawing Following pair 0.5 mm dia FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Telephone Socket Outlet
TV anteena Socket Outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
4/5 Module (78mm x140mm x 50mm)
6 Module (78mmX205mmx50mm)
8/9 Module (78mmX230mmx60mm)
12 Module (135mmX205mmx60mm)
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing Ding dong sound call bell single phase, 230 volts, complete as required.
Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
Supply & drawing following sizes of FR PVC insulated copper conductor single core cables in existing surface/recessed steel / PVC conduit including dismantling as required. 2 x 1.5 sq.mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way Double Door
12 Way Double Door
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 Way (4+18), Double Door Horizontal Type
8 Way (4+24), Double Door Horizontal Type
Supplying and fixing following ways surface / recess mounting Vertical type 415 Volts TPN MCB distribution board, of sheet steel dust protected duly power painted inclusive of 200 Amps tinned copper bus bar common, neutral link, earth bar, din bar, for mounting MCB's (But without MCB's and incomer) as required. ( Note:- Vertical Type MCB TP DB is normally used where 3phase outlets are required.
8 Way (4+18), Double Door Vertical Type
12 Way (4+24), Double Door Vertical Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6 / 32 Amp Single Pole
40 Amp DP
50/63 Amp DP
6/32 Amp TPN
40 Amp TPN
50/63 Amp TPN
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Providing and fixing H.T. danger Notice plate of 250mm x 200 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.
For 10 way, Double door SPN MCBDB
For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required.
For 6 way, Double door TPN MCBDB
For 8way, Double door TPN MCBDB
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required.
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing of lighting conductor finial made of 25 mm dia 300 mm long, GI tube having single prong at top with 85 mm dia 6mm thick G.I Base plate including hole etc. as required
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Horizental Run)
Providing and fixing GI Tape 20mmx 3mm thick on parapet or surface of wall for lighting conductor complete as required. ( for Vertical Run)
Providing and fixing testing Jointing made of 20mmx 3mm thick G.I Strip 125 mm Long. With 4 nos of G.I bolts. Nuts chuck nuts and spring washers etc. as required
Providing and Laying G.I tape 32mm x 6mm from earth electrode directoly in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
INSPECTION CHAMBER:
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run of cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with cable tie)
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 x 6 sq. mm (19mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm (35mm)
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (50mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
3½ X 300 sq. mm (70mm)
4 X 10 sq. mm (25mm) including 4x6 sq.mm
4 X 16 sq. mm (28mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm wide x 50 mm depth x 1.6 mm thickness.
150 mm wide x 50 mm depth x 1.6 mm thickness.
300 mm wide x 50 mm depth x 1.6 mm thickness.
450 mm wide x 50 mm depth x 2.0 mm thickness.
600 mm width X 50 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2 mm thickness
900 mm width X 62.5 mm depth X 2.0 mm thickness
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required 125 A 15kA SC for 1 sec (including 100A)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes cubicle panel, making connections, etc. as required. 100 A, 35 KA,TPMCCB
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).
3.5 core, 300 sq.mm.
3.5 core, 240 sq.mm.
3.5 core, 185 sq.mm.
3.5 core, 150 sq.mm.
3.5 core, 120 sq.mm.
3.5 core, 95 sq.mm.
3.5 core, 70 sq.mm.
3.5 core, 50 sq.mm.
3.5 core, 35 sq.mm.
4 core, 16 sq.mm.
4 core, 10 sq.mm.
4 core, 6 sq.mm.
2 core, 16 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray.
1C x 50 sq.mm PVC Insulated cu wire including termination etc.
1C x 16 sq.mm PVC Insulated cu wire including termination etc.
Supply, erection, testing and commissioning of following sizes of TV splitter of aluminium die cast body in suitable size of G.I. Box. 4 way
Supply, erection, testing and commissioning of following co-axial cable in existing conduit. RG-11
Supply & installation of 32 Amp 3 phase, 415 volt, 50 Hz water tight (IP-55) socket outlet with interlocking switch complete with all fixing accessories.
Supply & installation of 32 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories as below.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
100 mm wide x 40 mm deep.
200 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.
150 mm wide x 50 mm deep.
250 mm wide x 50 mm deep.
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mm x 6mm copper strip) front door with glass as complete as required.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM
Ten Loop Panel.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supply, installation, testing and commissioning of addressable monitor module complete as per specification
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. Same make as of Fire Alarm System.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. Same make as of Fire Alarm System.
Supply Installation, Testing & Commissioning of fire fighter main console at control room including power supply and accessories. (Approved Makes: Notifie by Honeywell, Bosch, Advance)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 480 Watt, supply complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm
SUPPLY & INSTALLATION OF LIGHT FIXTURES & FANS
Supply Installation, Testing & Commissioning of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required.
12W LED Round Down Light
15 / 16 W LED Round Down Light
18 /20 W LED Round Down Light
2' x 2' LED Panel Light
Bulk Head fitting with 9/10Watt LED.
Supply Installation, Testing & Commissioning of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.
10/12 W LED Tube Light
20/22 W LED Tube Light
30 W COB based round LED Light with multiple beam angles (36 Degree)
Supply Installation, Testing & Commissioning of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required.
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. . 1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
UPS SYSTEM
Supply, fitting, fixing, testing and installation of 50 KVA, ON Line UPS three phase input and three phase out put power system of in put voltage range 360V/380/V/400V/485V AC , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor 0,8/3.1, Harmonic distrortion -< 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required.
UPS shall carry design output at 40 deg.
Shall have soft start and hold of for incoming supply.
Invertor capability to supply 150% load for 5 sec.
SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transforme.
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.
Suitable size of copper cable between UPS and battery bank shall be provided
UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS.
Supply Installation, Testing & Commissioning of MS Battery Rack suitable for 40 to 50 UPS Battery Installation.
Supply Installation, Testing & Commissioning of 60 nos. 65 AH Flat type Sealed Maitanace Free (SMF) Battery with 24 months replacement warranty. IS:1652:1991. (VAH Required minimum 46800 for 50 KVA UPS (65AH x 60 Nos. x 12V = 46800 VAH) 50 KVA UPS, Batteries & Accessories (A+B+C)
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6 U/FTP 24 Port- Loaded as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6 U/FTP 48 Port- Loaded as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6 U/FTP 3 feet as per technical specification.
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6 U/FTP 7 feet as per technical specification
Supply, Installation, Testing, Commissioning of Cat 6, 10G, U/FTP, Information Outlet including G.I. Box and modular cover plate as per technical specification.
Supply , Installtion , Testing and comissioning of 15U wall mount rack with fans , 2 cable managers, satationary shelf , 2 Nos of hardware pkts as per technical specification.
Supply, Installation, Testing & Commissioning of Network Rack 42 U with below included: Network Rack 800W x 2000H x 800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs, 42 U 19" Profile Type angle,Front & etc. complete as per technical specification.
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE as per technical specifications.
Supply, Installation, Testing & Commissioning of 48 port 10/100/1000Mbps, 4 SFP Module, L-2 Switch, POE as per technical specifications.
Supply, Installation, Testing & Commissioning of IP Based voice Communication System with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility , 200 IP users License ,01 Nos. IP Operator Console, 30 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, - Redundant server in active-Active mode as per technical
Supply, Installation, Testing & Commissioning of Type 1 IP Phone . Graphic LCD display with backlight 3 user accounts with multi-line appearance keys Local and company-wide phone directories.
Supply, Installation, Testing & Commissioning of Type Basic Phone account , Full duplex speaker phone, .
Supply, Installation, Testing & Commissioning of Core Switch 24 1Gb/10GBASE-T ports, 2 10Gb/40Gb QSFP+ ports, 4 10Gb/25Gb/40Gb/50Gb/100Gb capable QSFP28 ports, 2 populated power supplies slots, with suitabe fan module slots, supporting RIP, OSPF, VRRP L3 protocols from day one as per technical specification.
Supply, Installation, Testing & Commissioning of SFP+ 10GBASE-SR 10 Gigabit Ethernet Optics, 850 nm for up to 300 m,transmission on multimode fiber (MMF).
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable as per technical specification.
Supply, Installation, Testing & Commissioning of 24 Port LC multimode loaded LIU.
Supply , Installtion , Testing and comissioning of 48 port loaded LIU for core switch to access switch connectivity over fiber.
Supply, Installation, Testing & Commissioning of LC - LC Fiber patch cord OM4, 3 Mtrs.
Supply, Installation, Testing & Commissioning of 6 Core, Single Mode, OS2 as complete as required.
IP CCTV SYSTEM
Supplying, installation, testing & commissioning of 5MP 30 fps HD Indoor IP Dome camera with1/3-inch CMOS, Sensor pixels 1920 x 1080, Sensitivity-0.04 lx (color) , Dynamic range 75 dB Wide Dynamic Range (WDR), True day/night, Automatic Electronic Shutter, Video compression H.264 ; M-JPEG, White balance, BLC, H.264 quad-streaming, Motion/tamper/audio detection, Privacy Mask, Lens 3.6 mm lens, 3-axis adjustment (pan/tilt/ rotation), ONVIF Profile S, CE Certified.
Supplying, installation, testing & commissioning of 5MP 30 fps HD indoor / outdoor IR IP bullet camera with 1/3‑inch CMOS, Sensor pixels 2612 (H) x 1980(V), Sensitivity-0.24 lx (color) 0.04 lx (mono) ,IR range 30 mtrs, Dynamic range 70 db, True day/night, Automatic Electronic Shutter, Video compression H.264 MP ; M-JPEG, White balance, BLC, Analog video output, Lens (zoom / focus) 3.6 mm lens, Two-way, full duplex Audio, Audio compression AAC, G.711, L16 , ONVIF Profile S, CE Certified.
Supply installation and commission of pann tilt zoom camera with 360 deg pan and 90 deg tilt with 36 X Zoom having maximum resolution of Max. 1920 × 1080 @30fps,true day night camera with 130 m IR range , optional, fine picture at Ultra-low light,supports compression format H.265, H.265+, H.264+, H.264, 3D Digital Noise Reduction support.
Supply Installation, Testing & Commissioning of IP network recorder with following feature Processor - Dual-core embedded processor . Two-way Talk - 1 channel Input, 1 channel Output, RCA,Video Output - 1 HDMI, 1 VGA , IP Camera Input - 8/16/32 Channel IP , Compression - H.264+/H.264/MJPEG,Video Resolution - 2560 × 1920, 2048 × 1536, 1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768 , Hard Disk - 4 SATA Ports, up to 8TB ,Motion Detection - MD Zones: 396 (22 × 18),Recording Mode - Manual, Schedule (Regular, Continuous), MD (Video detection: Motion Detection, Camera Blank, Video Loss), Alarm, Stop, Backup Mode - USB Device /Network , Interface Ports - 1 HDMI, 1 VGA, 2 USB(1 USB 2.0 , 1 USB 3.0 ), 1 RS485, 1 RS232, 1 RJ45.
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required.
Supply, installation, testing and commissioning of of 6 TB HDD all accessories complete as required.
Supply installation and commissioning of 48 inch LED monitor for disply of camera.
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM
For Server Room
Supply, fixing, testing and commissioning of UL Listed & PESO Approved High Pressure Seamless BIS 7285 approved Cylinders with contact Pressure Gauge & PESO Approved Valve, Including all fittings and accessories with Respective size mounting bracket. The cylinder size to be considered respective to filling density allowed by OEM
140 Ltr (Master Cylinder)
140 Ltr (Slave Cylinder)
FK 5-1-12 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions.
Master Cylinder Kit complete Comprising all mandatory accessories : Electric Actuator, Manual Release Device, Discharge Hose - DN 50, Manifold Check Valve, Reset Toolkit, Cylinder Strap, Caution Advisory Signage’s, System should include Electric Control Head operated electrically from the detection and control system with a manual actuator and Wire Braided Flexible Rubber Hose with Elbow and connectors complete assembly to Connect FK 5-1-12 Cylinder Assembly Discharge outlet with Discharge Pipe or Discharge Manifold. On any displacement of solenoid valve, master cylinder kit shall be able to notify the fault by audio/visual mean.
Slave Cylinder Kit Complete Comprising all mandatory Accessories: Pneumatic Release Device, Actuation Hose, Discharge Hose - DN 50, Manifold Check Valve, Cylinder Straps & Caution Advisory Signage’s to Connect FK 5-1-12 Slave Cylinders.
Discharge Nozzles to Discharge FK 5-1-12 Gas in the Hazard Area as hydraulic calculation and flow rate required in 180 Deg/360 Deg Discharge Pattern.
Supply, fixing, testing and commissioning of 'Discharge Pipe with Support and Fittings, CS Seamless to ASTM A-106 Schedule 40/50. along with threaded fittings of 3000# conforming to ANSI B 16.11
Supply, fixing, testing and commissioning of 2 Zone Microprocessor Based Automatic Gas Extinguishing Panel with 2 Batteries. Two Zone automatic extinguishing panel should be CE Approved and Operates on 220-240 VAC, 10%, 50 Hz, 100W. Consisting Smoke Detector/Heat Detector/Multi Detector, Manual Release Switch. The Manual release switch module shall comply with the requirements of BS7273-1/UL, Abort Switch. The Abort switch module shall comply with the requirements of BS7273-1/UL, Hooter with Strobe Light, Response Indicator & Discharge And Pre Discharge Indicator., along with Loop Cable (2C x1.5mm) Armoured.(Fire Alarm System with respect to Room size)
MAIN L.T. PANEL
(Each Incomming / outgoing MCCB shall have microprocessor release and variable current setting from front, adjustable overcurrent, short circuit & earth fault protection, front extended lockable handle, pad lockable in off position, shrouding on incomer side, termination shall be suitable for aluminium bus bars / cables and as per specification.)
EMS software with screens, dashboards / Modbus data, Ethernet gateways, 8 port ethernet switch and reports for atleast 50 devices (Multi Function & Energy Meters). Software shall comply latest cybersecurity standards as per IEC62443-4-1 and IEC62443-4-2 (SL1) & ISO 50001.
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
INCOMERS from 1 Nos. 1000 KVA Transformers
1 nos. 1600 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947
The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.
1 nos. 32 amp TP MCCB (50 KA) for OLTC (for each transformer incomer)
Protection releases / relays, Metering & Accessories for each Transformer incomers
Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA)
Over Voltage / Under Voltage relay / release (3 phase) with timer.
Backup earth fault relay.
Restricted earth fault relay.
There shall be a provision : - If REF operates, they send a signal to Upstream HT breaker of Transformer incomer ( in HT Panel) to make it "OFF" for protection of transformer.
Master trip relay.
Trip Circuit Supervison relay.
TNC switch.
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 1600/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse.
1 set of 4 CT's of ratio 1600/1A, Class PS for protection.
1 no. CT's of ratio 1600/5A, Class 5P10 for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Power factor meter.
Frequency meter.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.
INCOMERS from 2Nos. 500 KVA D G sets
1 nos. 800 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947.
Protection releases / relays, Metering & Accessories for each D G set incomers
Over Voltage / Under Voltage relay / release (3 phase) with timer.
IDMT earth fault relay.
Backup earth fault relay.
Master trip relay.
Trip Circuit Supervison relay.
Reverse power relay.
Voltage restrained over current relay.
TNC switch.
1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB.
1 set - 3 CTs of ratio : 800/5A , Class 1.0 accuracy 15 VA each burden for metering.
1 set - 3 CTs of ratio : 800/5A , Class 5P20 accuracy 20 VA each burden for protection.
Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. (or Dual meter)
Frequency meter.
Power Factor meter.
1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing.
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
12 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares.
Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop.
Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps.
D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out.
1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (500 KVA)
Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same.
The ACB shall be electrically interlocked with the bus coupler and Transformer incomers.
BUSCOUPLER
1 no 800 AMP Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2.
Protection releases / relays, Metering & Accessories for Bus Coupler (s)
Trip circuit supervision relay
TNC switch.
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.
The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up.
BUSBARS
2000 Amp TPN busbars of aluminium alloy as per SLD.
MICRO PLC FOR AUTO OPERATION OF INCOMER / BUSCOUPLER ACB's.
Auto changeover.
Incomers & Buscouplers switching.
Necessary hardware shall be provided to achieve above functions including micro PLC with real time clock, digital inputs/outputs, MMI with 2 line display, power supply, auxillary relays, PB's indication etc. & software for the above.
Automatic system shall be user friendly and shall have manual override.
BATTERY & BATTERY CHARGER
1 No. 24V, 72AH SMF Battery with suitable battery charger for control supply.
OUTGOING
01 Nos 1000A TP MDO ACB (50KA)
02 Nos 800A TP MDO ACB (50KA)
01 Nos 630A TP MCCB (35 KA)
05 NoS 250A TP MCCB (35 KA)
04 No 160A TP MCCB (35 KA)
20 No 100A TP MCCB (50 KA)
Main L.T. Panel Described as Above.
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL)
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 350 KVAR A P F C Panel with 14% Detuned LC Filter consisting of 5 /10 / 25 / 50 / 100 KVAR (at 415 Volts rated voltage of bank shall be 525 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 42, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 .
The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item).
All out going MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.
AC3 duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 50 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.
INCOMING
Incomer circuit breaker has been included in the main panel.
1 set- 3 CTs , ratio 1000 / 5A Class 1.0 accuracy 15 VA burden for metering.
Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 13 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.
BUS BARS
1600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints.
OUTGOINGS
Capacitor Panel as described above
DISTRIBUTION PANEL
L+P PANEL ( STILT TO 6TH FLOOR)
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
02 Nos. 40 Amp FP MCB (10 KA)
06 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
AHU PANEL ( GROUND TO 4TH FLOOR)
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
6 Nos. 25Amp FP MCB (10 KA)
2 Nos. 40Amp FP MCB (10 KA)
2 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
AHU PANEL ( 6TH FLOOR)
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
02 Nos. 25 Amp FP MCB (10 KA)
06 No. 40 Amp FP MCB (10 KA)
03 Nos. 63 Amp FP MCB (10 KA)
Panel described as above
LIFT PANEL (TERRACE FLOOR)
INCOMING
2 No. 160 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 160 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
04 Nos.63 Amp FP RCCB (300 mA).
04 Nos.40 Amp DP MCB (10 KA).
Panel described as above
PRESSURIZATION PANEL ( TERRACE FLOOR )
INCOMING
1 No. 100 Amp FP MCCB (35 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
10 Nos.40 Amp FP MCB (10 KA).
Panel described as above
OT ISOLATION PANEL
INCOMING
1 No. 63 Amp DP ELCB, 30mA.
1 No. 10 KVA, 230V AC medical grade Isolation Transformer.
1 No. 63 Amp DP Miniature Circuit Breaker. (10 KA)
1 No. Sensor and LIM, 0-10mA.
BUSBAR
100 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
16 No. 6-25 Amp SP Miniature Circuit Breaker. (10 KA)
OT Isolation Panel described as above
UPS I/C PANEL ( BASEMENT FLOOR )
INCOMING
2 No. 250 Amp FP MCCB (35 KA)
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS COUPLER
1 no 250 AMP FP MCCB
BUSBAR
400 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
4 Nos. 160Amp FP MCCB (35 KA).
Panel described as above
UPS O/G PANEL ( BASEMENT FLOOR )
INCOMING
3 No. 160 Amp FP MCCB (35 KA)
3 Set of phase indicating lamps with Single Pole MCB.
3 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN copper busbar with coloured heat shrinkable sleeve.
OUTGOING
3 Nos. 100Amp FP MCCB (35 KA).
2 Nos. 160Amp FP MCCB (35 KA).
1 Nos. 200Amp FP MCCB (35 KA).
3 Nos. 63Amp FP MCCB (35 KA).
Panel described as above
UPS PANEL-01 (GROUND FLOOR )
INCOMING
2 No. 200 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 200 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
300 Amp TPN aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
2 Nos.100 Amp FP MCCB (25 KA).
2 Nos.63 Amp FP MCB (10 KA).
8 Nos.40 Amp FP MCB (10 KA).
Panel described as above
UPS PANEL-02 & 04 ( 2ND & 5TH FLOOR)
INCOMING
2 No. 100 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 100 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
06 Nos. 40 Amp FP MCB (10 KA)
02 Nos. 63 Amp DP MCB (10 KA)
Panel described as above
UPS PANEL-03 ( 4TH FLOOR)
INCOMING
1 No. 160 Amp FP MCCB (35 KA)
1 No Fixed type Automatic transfer switch 160 Amp rating in open frame with live to live transfer time <150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS.
2 Set of phase indicating lamps with Single Pole MCB.
2 Set of ON / OFF indicating lamps with Single Pole MCB.
BUSBAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
5 Nos.63 Amp DP MCB (10 KA).
4 Nos. 40 Amp FP MCB (10 KA).
02 Nos.63 Amp FP MCB (10 KA).
Panel described as above
LAUNDARY PANEL
INCOMING
1 No. 160 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
10 Nos.63 Amp FP MCB (10 KA).
07 Nos.40 Amp FP MCB (10 KA).
Panel described as above
CSSD PANEL
INCOMING
1 No. 250 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium busbar.
OUTGOING
09 Nos.63 Amp FP MCB (10 KA).
06 Nos.63 Amp FP MCB (10 KA).
Panel described as above
KITCHEN PANEL
INCOMING
1 No. 250 Amp FP MCCB (25 KA)
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
BUS BAR
250 Amp TPN aluminium busbar.
OUTGOING
08 Nos.63 Amp FP MCB (10 KA).
06 Nos.40 Amp FP MCB (10 KA).
08 Nos.25 Amp FP MCB (10 KA).
16 Nos.63 Amp DP MCB (10 KA).
12 Nos.40 Amp DP MCB (10 KA).
Panel described as above
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker (35 KA) with 100 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
08 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 40 Amp DP MCB (10 KA)
Panel described as above
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 500 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
AUTOMATIC FIRE DETECTION GAS SUPPRESSION SYSTEM IN PANELS
For Main LT Panel, Lift & Firefighting Panel
Supply, fixing, testing and commissioning of Automatic Linear pneumatic Tube Detection based FK 5-1-12 Pre-Engineered System for Electrical Panels (consisting of the following components.
2.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.
4.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.
6.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation..
UL Listed Linear Pneumatic Heat Detection Tube with all necessary fittings & supports, HR Grade,UV Protected, MultiLayered, Made of Special Modified Polyamide Material, Inner diameter 4mm, Outer Diameter 6MM, Operating Pressure 15 8Bar, Maximum Pressure 30 Bar at maximum Temperature of +65 Degree C, Pressurized
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).
DG SET, SUBSTATION & EXTERNAL LIGHTING WORK
DIESEL GENERATING SET
Supply, Installation testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per latest CPCB norms) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following.
Diesel Engine -
Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system.
Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings :
Start stop switch with key
Water temperature indication
Lubrication oil pressure indication.
Lubrication oil temperature indication.
Battery charging indication
RPM indication
Over speed indication
Low Lube oil trip indication
Engine hours indication
Alternator -
Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required.
Note : - Alternator should have with all other accessories as per specified in Technical specfications.
Provision of installation of CT's before star point for Differential protection scheme. (DG sets for 500 KVA only)
Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.
Microprocessor based Power command controller (P.C.- 3.3 Jakson or equivalent) suitable for auto / manual synchronization & auto load sharing.
Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.
Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required.
Exhaust Silencer - Exhaust manifold with residential silencer.
The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system.
Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.
Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval)
250 mm dia (wall thickness - 4.85 mm)
Supply & fixing of SS Bellow of following diameter 250 mm dia
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.
11 KV HT VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE)
Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device.
Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C x 300 sq.mm. XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item).
a) 1 No, 630 Amp, VCB.
d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
e) 1 No - set of dual core dual ratio 3 CTs 100/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
g) 1 No. hooter with hooter acceptance and reset push button.
h) 1 No - Red, Yellow & Blue for phase indication.
i) 1 No - Amber for Trip indication.
j) 1 No - Red `ON' Green `OFF'indication.
k) 1 No - Spring charge indication.
l) 1 No - Auto trip indication.
m) 1 No. hooter with hooter acceptance and reset push button.
n) 1 No. master trip relay. ( Electromechanical Type )
o) 1 No.Trip ckt supervision relay. (Electromechanical Type )
a) Outgoing - 2 No, 630 Amp, VCB.
c) 2 No - Microprocessor based numericak relay with O/C, E/F and S/C protection.
d) 2 No - set of dual core dual ratio 3 CTs 100/5 A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection.
e) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories.
f) 2 No. hooter with hooter acceptance and reset push button.
g) 2 No - Red, Yellow & Blue for phase indication.
h) 2 No - Amber for Trip indication.
i) 2 No - Red `ON' Green `OFF'indication.
j) 2 No - Spring charge indication.
k) 2 No - Auto trip indication.
l) 2 No. hooter with hooter acceptance and reset push button.
m) 2 No. master trip relay. ( Electromechanical Type )
n) 2 No.Trip ckt supervision relay. (Electromechanical Type )
o) 2 No.auxiliary relay for transformer fault.
p) Power pack.
H.T. Panel described as above
TRANSFORMER
Design, manufacture, supply, installation, testing and commissioning of out door type copper wound transformer continuously rated for 3Ph 50 Hz at full load rating the transformer should have oil immersed winding having vector group DY-11, HT side connected in star with neutral brought out connected to provide separate earthing. The transformer shall have power terminal arrangement bushing / cable end box on HT side and cable end box on LT side. 1000 KVA, 11 KV /0.415 KV, 3 phase, 5.0 % impedance, 50 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the Transformer. The transformer should have following standard as per amended IS specification and the load * no load losses shall be limited to the values given below or as per IS 2026 and latest IS-1180 or Norms issued by SEB which ever are Lower.
Oil Conservator with filling hole with cap and plain oil level gauge.
Silica gel dehydrating breather charged with silica gel.
Oil drain Valve
Oil Filter Valve
Lifting eyes / Hooks
Two earthing Terminals
Diagram and rating plate
Air Vent
Explosion Vent
100 mm dia thermo meter with thermometer pocket
Four bi directional plain roller
Buchholz relay
Resistance Temp detector
Marshalling box
Automatic Voltage Regulator ( AVR)
Remote Tap Changing controller ( RTCC)
Transformer 11000/415 volts with on load Tap changer -15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2
11 KV END TERMINATION:
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 240 Sqmm, 11KV XLPE
11 KV H.T. CABLE:
Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 240 Sqmm, 11 KV XLPE
Laying of one number additional PILCA / PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of size exceeding 120 sqmm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning protective covering and refilling the trench etc. as required.
Supply & Laying of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS.
4 core, 2.5 sq.mm.
10 core, 2.5 sq.mm.
12 core, 2.5 sq.mm.
Supply & Fixing of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd
EXTERNAL LIGHTING
Supply Installation, Testing & Commissioning of Following rating LED Street Lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection ) in existing pole / pipe for supply voltage 100-270 AC 50Hz Luminare shall be confirm to IS :10322 part 5/ section-3 and shall be complete with all nessessary accessories as required. 60W LED Street Light
Supply Installation, Testing & Commissioning of Following rating LED Post Top lamp made in die cast aluminium housing with decorative clear / opel acrylic diffuser on existing pipe including connection with 1.5sq.mm coppwr conductor etc all complete as required. 20/25W LED Post top lamp clear
Supply Installation, Testing & Commissioning of Following rating approved make LED Bpllard Fitting with cylindrical shape and inverted cone shape head of height 600 to 850 mm power input -8/9 watt with die cast aluminium housing opel with PC diffuser, IP-65/54 protection, conferming to IS : 10322 part 5 etc all complete as requird. (Excluding Plinth Charge.)
Supplying & installation of 7 mtr. Height Octagonal Hot Dip galvanized pole (BOP. 7030) with top dia 70 mm bottom dia 130 mm & made of 3 mm thick sheet base plate dimensions 200x200x12 mm (LxBxT) including suitable size of foundation bolt all complete as required (without Arm).
1m Single Arm Suitable for 70MM Top
MEDICAL GAS PIPELINE SYSTEM
OXYGEN SYSTEM
Supply, Installation, Testing and commissioning of Liquid Oxygen Vessels of 7 KL (Primary supply) with working and stand by natural vaporizer, LOX and Vaporiser should have all necessary controls and safety fittings. LOX system covered with the fence and suitable pedestal for LOX. Natural Vapouriser, 1500 lpm capacity with necessary controls and safety fittings. Liquid oxygen to gas manifold Automatic control panel, 1500 lpm deliver capacity with necessary controls and safety fittings. Liquid oxygen to gas manifold Fully Automatic control panel (Imported), 2000 lpm deliver capacity with necessary controls and safety fittings.
Supply, Installation, Testing and commissioning of 2 x 10 size manifold (Secondary supply) complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder as per HTM 02-01/IS-ISO-7396-1 and headers shall have isolation valves.
Supply, Installation, Testing and commissioning of 2 x 6 cylinder manifold (Emergency supply) complete with chain for individual cylinder along with Non Return Valves for every cylinder, high flow double gauge regulator as per HTM 02-01/IS-ISO-7396-1 and headers shall have isolation valves.
Supply, Installation, Testing and commissioning of Fully Automatic control panel (Imported) for Oxygen Having a min. flow out put of over 2000 lpm at 4.2 bar pressure as per HTM 02-01.
Supply, Installation, Testing and commissioning of Surface mounted front loading Oxygen outlets as per HTM 02-01/IS-ISO-7396-1 (first and second fix assembly)
H.P. tubing having anti static core white color 5mtrs with heat conversion for Oxygen as per ISO Standards
NITROUS OXIDE SYSTEM
Supply, Installation, Testing and commissioning of 2 x 6 size manifold (Primary & Seccondar supply) complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder as per HTM 02-01/IS-ISO-7396-1 and headers shall have isolation valves.
Supply, Installation, Testing and commissioning of Fully Automatic control panel (Imported) for Nitrous Oxide Having a min. flow out put of over 500 lpm at 4.2 bar pressure as per HTM 02-01.
Supply, Installation, Testing and commissioning of Emergency Two cylinder Nitrous oxide arrangement using a high flow double gauge Regulator as per HTM 02-01/IS-ISO-7396-1
Supply, Installation, Testing and commissioning of Surface mounted front loading outlets as per HTM 02-01/IS-ISO-7396-1 (first and second fix assembly)
H.P. tubing having anti static core Blue color 5mtrs with Heat conversion for Nitrous Oxide as per ISO Standards
CARBON DIOXIDE SYSTEM
Supply, Installation, Testing and commissioning of 2 x 4 size manifold (Primary & Seccondar supply) complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder.
Supply, Installation, Testing and commissioning of Two cylinder cylinder Emergency Carbon dioxide arrangement using a high flow double gauge Regulator. HTM 02-01/IS-ISO-7396-1
Supply, Installation, Testing and commissioning of Fully Automatic control panel for Carbon dioxide Having a min. flow out put of over 500 lpm at 4.2 bar pressure.
Supply, Installation, Testing and commissioning of Surface mounted front loading outlets (first and second fix assembly) HTM 02-01/IS-ISO-7396-1
H.P. tubing having anti static core Blue color 5mtrs with Keat conversion for Carbon dioxide as per ISO Standards
MEDICAL AND SURGICAL AIR SYSTEM
The unit should have Duplex stationary air cooled silenced (Reciprocating) Oil-Free Air Compressor with critical maintenance free technology each having 57.18 scfm capacity.
Supply, Installation, Testing and commissioning of Air receiver, Vertically mounted welded carbon steel, each having capacity of 2000 litres and receiver should have all necessary controls, piping and safety fittings with an automatic drain with manual by-pass. It should comply with BS EN 286-1: 1998
Supply, Installation, Testing and commissioning of air filters, pre-filter, oil filter, dust filter, activated carbon filter and bacterial filter. Each filter should be fitted with differential pressure gauges to monitor filter performance with all necessary controls, piping and safety fittings.
Supply, Installation, Testing and commissioning of Air dryer system, capacity of each should be 100% of plant design flow, include a dew-point hygrometer and display with a minimum accuracy of ±3°C, Duplex desiccant dryers should be used and in a range from –20°C to –60°C with a set point of –46°C.
Supply, Installation, Testing and commissioning of Surface mounted front loading double locked gas oulets HTM 02-01/IS-ISO-7396-1
a) Medical Air-4 bar
b) Surgical Air-7 bar
Supply, Installation, Testing and commissioning of dedicated Electrical Control Panel for compressed air System & complete with plant Room wiring .
Supply and installation of pressure regulating system, should have Pressure regulator, Isolation valve, Pressure indicator for Medical Air regulation with an by pass arrangement. Which includes 4 Nos of isolation valve, 2 nos of regulators, 2 nos of pressure indicator and Pressure relief valve.
HP colour coded black Tubing as per ISO Standards
VACUUM SYSTEM
Duplex 7V Vacuum Pumps of Ingersoll with Motor each with receiver vessel, with bacteria filter capacity.The system to provide duplex/cascade vaccum system for automatically start and stop at 480mm and 650 mmHG
Supply, Installation, Testing and commissioning of vacuum receiver, Vertically mounted Mild steel, each receiver capable of supply 2000 liters at 450 mm hg pressure and receiver should have all necessary controls and safety fittings with an automatic drain with manual by-pass.
Supply, Installation, Testing and commissioning of Medical bacterial filters (Imported) should be fitted, each containing a replaceable filter element and incorporating a moisture drainage trap bowl. The pressure drop through a clean filter passing total design flow rate should not exceed 25mmHg at a vacuum of 475mmHg.The bacteria filters manually -operated isolating valves, arranged to allow either sub-assembly to be on stream.
Supply, Installation, Testing and commissioning of dedicated Electrical Control Panel for Vacuum System & complete with plant Room wiring.
Supply, Installation, Testing and commissioning of Surface mounted front loading double locked Vacuum out lets,as per HTM 02-01/IS-ISO-7396-1 (first and second fix assembly)
High Pressure color coded yellow Tube as per ISO Standards
ANESTHETIC GAS SCAVENGING SYSTEM (AGSS)
Supply, Installation, Testing and commissioning of Duplex AGSS pump, capable of deliver flow rate of 1500 l/min with Duplex pump (Rotay vane type), each terminal unit. The system should conform to the requirements of HTM standard.
Supply, Installation, Testing and commissioning of AGSS terminal unit (first and second fix assembly) HTM 02-01/IS-ISO-7396-1
Supply, Installation, Testing and commissioning of control panel should be provided, AGSS pump to house the isolating switch, starter, MCB, ammeter, hours run meter, hand/auto switch, alarm and BMS contacts. design flow with one pump not running. The control panel should have all design flow with one pump not running. The control panel should have all necessary controls and safety fittings. Controls signals as per HTM.
PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of Copper Pipe 'Lloyd Certified' as per HTM/ EN for medical gas services. Pipes shall be priced for all necessary supports, standard fittings.
12 mm OD x 0.7 mm thick
15 mm OD x 0.9 mm thick
22 mm OD x 0.9 mm thick
28 mm OD x 0.9 mm thick
42 mm OD x 1.2 mm thick
54 mm OD x 1.2 mm thick
76 mm OD x 1.5 mm thick
Supply, Installation, Testing and commissioning of Isolation Valve assembly as per HTM 02-01/IS-ISO-7396-1 for medical gas services, provision for padlock assembly. All valve should be gas specific.
Supply and installation of AVSU box (valve boxes) with all its accessories with valve and pressure / vacuum gauges, NIST connectors with lockable arrangement and breakable glass cover. HTM 02-01/IS-ISO-7396-1
2 valve configuration with
3 valve configuration
15 O2, 22 MA4, 22 VAC
5 valve configuration
15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC
6 valve configuration
15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC, 15 CO2
ALARM SYSTEM
Providing and fixing alarm system for Medical gas system complete consisting of pressure sensors, panel and the control cabling, all wiring shall be within 1mm sq multi core data cable, PVC pipe for data cable. Panel shall be self contained low voltage (less than 24 V) HTM 02-01/IS-ISO-7396-1
2 valve configuration with
3 valve configuration
15 O2, 15 MA4, 22 VAC
5 valve configuration
15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC
6 valve configuration
15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC, 15 CO2
Supply, Installation, Testing and commissioning of Master alarm with 125 call points with six gas configration (Oxy, N2O, MA4, SA7, VAC & CO2). It shall indicate all the status of operation going on in automatic control panel for O2, N2O, CO2, Compressed air, AGSS, Vacuum systems. HTM 02-01/IS-ISO-7396-1
Supply, Installation, Testing and commissioning of Bed head Panel (Indigenous). It shall have the following services. Costing including all below fixtures in the BHP to be considered HTM 02-01/IS-ISO-7396-1
Bed head panel for all HDU's & ICU's,
Medical gas outlets (Only provision - Outlets are already captured above)
4 Nos. of 6/16 Amp UPS power socket (to be added with BHP)
2 Nos. of 6/16 Amp RAW power socket (to be added with BHP)
1 no. of nurse call module-only provision
1 no. of RJ-45 data outlet with base plate (Refer networking specifications)- only provision
Bed head panel for Pre / Post OP & Emergency
Medical gas outlets (Only provision - Outlets are already captured above)
4 Nos. of 6/16 Amp UPS power socket (to be added with BHP)
2 Nos. of 6/16 Amp RAW power socket (to be added with BHP)
1 no. of nurse call module-only provision
1 no. of RJ-45 data outlet with base plate (Refer networking specifications)- only provision
OXYGEN FLOW METER & HUMIDIFIER BOTTLE Back Pressure Compensated Flow meter shall be of accurate gas flow measurement and control within a range of 0-13 lines per minute for use in a variety of respiratory therapy gas delivery system. The flow tube and shroud components shall be made of good quality plastic. They shall be supplied with plastic transparent reusable humidifier bottle. HTM 02-01/IS-ISO-7396-1
WARD VACUUM UNITS The vacuum unit shall include vacuum regulator along with 0-760 mm of Hg vacuum gauge of 2 ½” size dial,600 ml capacity reusable plastic collection bottle with overflow safety trap with plastic slide wall mounted type. HTM 02-01/IS-ISO-7396-1
THEATRE VACUUM UNIT It shall be trolley mounted. The unit shall include one regular having gauge and mounted on the trolley stand, having two reusable each 2000 ml plastic collection bottles mounted on the base of trolley unit and connected with regulator & low pressure tube inter-connections. HTM 02-01/IS-ISO-7396-1
HOSPITAL FURNITURE
Providing and placing ICU BED Bed should be electrically operated Backrest, height, and Knee- break adjustment, Electrically operated Trendelenburg /Reverse Trendelenburg tilt (±12º), Under bed clearance to be 130 mm or more., Four sectional mattress with rexine cover, foam density should be 38-40., 70+_5° backrest for upright/ chest imaging., Side rails should be split type made from ABS injection moulding with easy to lower by sideways swing (tuck-away) to save space between the ICU Beds. Integral two pieces each side split safety sides with zero transfer gap. One button cardiac chair position., Dual sided drainage bag holders., Castors of size 5 inches., Bed be provided with telescopic IV rod one piece., Bed Lockout switches on Attendant Control Pendent., Bed have Angle indicator for backrest., Have locking mechanism for head and foot panels., Bed have Linked braking / steering systems with two diagonal locking castors/ four braking castors., 125mm (+/-10%) single wheel castors., Bed Dimensions Height Range- 46(+/-10%) – 76(+/-10%) cm Overall Length- 220 cm or more Overall Width- 980 mm Platform size- 85 x 199 cm., Corner bumper and IV socket should be integrated., Have mattress stopper for improving safety and better mattress positioning., Safe working load of 170 kg or more. SWL means bed should operate while 170 kg weight on bed and all movement should be functional., > Bed should have corner buffers for protection., > Electrical safety Standard Class.
Providing and placing Private Room Bed Frame and Platform made of CRCA steel, Dimension: 2030 L x 900 W x 600-800 H mm approx, Manually operated four functions bed featuring, back rest and knee-rest, Trendelenburg's, reverse Trendelenburg's and High, Low (Hi-Lo) positions, Plastic/ABS Bed Head panels and Split Railings, IV Rod, 125 mm Castors with locking system, Pre-treated and Epoxy Powder Coated finishing. with Mattress to be four sectional and to be combination of good quality foam with 30-40 Kg/m3 density in 4” thickness.
Providing and placing Fowler Bed Four section Fowler Bed. Top flat platform made of perforated CRC sheet of thickness of 18G., Bed frame must be sturdy and stable to support weight of at least 150-200kg. The frame structure made up of at least 16G / 18G CRC, ERW RHS pipe of 50/60 mm x 25/30 mm / Cylindrical pipe with Circumference of 180 mm. Bed frame mounted on trolley base made up of 50/60mm x 25/30mm CRC ERW RHS pipe of 16 gauge and 18 gauge. All adjustments for fowler position must be obtained from crank shaft, manually operated with stainless steel / ABS foldable handle on both the shaft., Finished bed must be rust proof, pretreated and powder coated., Telescopic side rails of Stainless steel of 20/22 Gauze with spring loaded locking arrangement / Fix on both sides., Easily removable head and foot panels made up of ABS plastic. Dimension: Mattress area of L1950 to 2100 mm X W900 to 1050mm H500 to 600mm (without mattress)., Single wheeled total locking type Swivel Castors of 100 to 150 mm diameter with diagonal locking breaks for stabilized position., Suitable buffer 100-150mm., With 2 no. good quality I. V. rod., Bed have hooks on bed frame on both side for holding urine / drainage bag (at least 2 Nos. on each side)., Mattress to be four sectional and to be combination of good quality foam with 30-40 Kg/m3 density in 4” thickness
Providing and placing Examination Couch Frame made of CRCA steel Cushioned Two section top Head section adjustable on Pneumatic pump Measuring 450 mm L x 510 mm W approx Body section admeasure 1380 L x 51 W mmapprox, Three drawers underneath the top section, Three storage units under the draws Pull-out foot-step Foldable/adjustable B.P. Apparatus tray Dimension: 1870 L x 510 W x 810 H mm approx Pre-treated and Epoxy Powder Coated
Providing and placing Bed Side Locker Frame made of CRCA steel tubes/ sheets Closed on three side, Single storage box and Single draw, SS top, On two 50 mm casters Two PVC shoes Dimension: 400 Lx 400 W x 800 H mm approx Pre-treated and Epoxy Powder Coated
Providing and placing Over Bed Table Frame made of CRCA steel tubes/ sheets Mounted on four 5 cm, Dia Swiveling castor,laminated board top of size 76 L x 41 W ,cms.Chrom plated telescopic sliding tube ,knob operated height with adjustable,pretreted and Epoxy powder coated/oven baked enamel.
Providing and placing Sline Stand (SS) Fully Staninless steel tube frame Plastic 5 pronged base, SS rod with double/four hook, Height adjustable by knob On 50 mm casters, Dimension: Base 575 mm dia, Height adjustable 1150 mm to 2025 mm approx
Providing and placing Medicine Trolley Frame made of Stainless steel tubes On 10 cms casters, With Two Top and Two Bottom drware Dimension: 760 L x 460 W x 810 H mm approx, Fully SS Finishing.
Providing and placing Dressing Trolley Stainless Steel frame Two Shelves, three-side railing on top shelf, Four side-railing on bottom shelf, Holder ring with SS bowl and bucket, Push handle, On 10 cms casters Dimension: 760 L x 460 W x 810 H mm approx
Providing and placing Instrument Trolley Stainless Steel frame and shelves, Three-side railing on top shelf, Four side-railing on bottom shelf, Push handle On 10 cms casters 760 mm L x 460 mm W x 810 mm H approx.
Providing and placing Wheel Chair Frame made of Stainless Steel tubes Fixed Arm-rest and Foot-rest, 18” Seat and Back-rest. Seat belt On 125 mm front casters, On 650 mm rear wheel with brakes Dimension: 1050 L x 650 W x 900 H mm approx.
Providing and placing Foot Step Frame made of Stainless Steel tubes/ sheet On PVC shoes Dimension: 450 L x 450 W x 450 H approx Fully SS.
ADMINISTRATIVE FURNITURE
Reception Table with Side unit Model :- DSS 9003 Size :- 2400(W)*850(D)*1100(H) MM Providing and Placing Reception Table of size 2400 x 850 x 1100/750 mm (wxdxh).Top made of 25mm thick prelaminated particle board & base in 18mm thick prelaminated particle board duly edge banded. Front partition panel laminated /upholested of 60 mm thick & 1100mm. height, snap on panel made of 12 mm prelaminated particle board duly edge banded with raceway running at above the worktop. Basic structure is composed of rolled steel vertical and horizontal members 38x38mm in 18 guage duly powder coated upto 40-50 microns to make the basic framework of partition. Partition has a cable raceways provided at the bottom as well as at any height in the partition as per the requirement. Structure can be configured into any shape in 90 degree angle. All steel components are duly powder coated. There is provision of single drawer in middle and three drawer unit on both side. All drawer are provided on telescopic channels.
Providing and Placing Medium Back Mesh Chair Overall Size 720W x 720D x 1180H. Seat Plywood Made Of 12mm Hot Pressed . Upholstery PVC Structure Moulded With Prime Quality High Stretch Fabric Mesh . PHA ( Gas-Lift ) 85mm (TDC 152mm & BDC 67) . Seat & Back Are Firmly Connected To The Base Frame Machanism . Machanism Provided Upright Position Locking Syncro Knee Tilt Similar To Centre But Mechanism Pivot is Close To The Knee Ensuring That Feet Remains On Ground While Reclining Back . Tilt Adjustment Can Be Operated In Seating Position . Chair Max Height 1180mm . 510W x 510D Base Seat 110mm Thick Moulded With PU Foam & 520W x 630H Back Seat PP Structure Moulded With Fabric Mesh . Adjustable Height Of Back Seat 110mm . Movebility Of Base Sheet 30mm . Base Sheet Shell PP Cover . Back Sheet Shell PP Structure With Mesh Back . 430 Handle In / 660 Handle Out Arm Rest Fixed Type Chrome Adjustable P.U . Arm Rest Height From Seat Min - 180mm & Max - 245mm . Height From Seat To Ground 535mm . Spine Bkt Chrome Plated Twin Pipe Structure . Understructure Made Of Chrome Plated Steel Base With 3 Piece Bellow . Casters Made Of Moulded Black & White Nylon Metal Bolt Inserted & Fitted With 5 Nos . Twin Wheel Casters 50mm Dia . Pedestral Pitch Centre Dia 656mm Without Casters & With Casters 720mm . on ground ensuring more comfort. Tilt tension adjustment. 4 -position locking with anti- shock feature .Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Four Seater Sofa2325(W)*710(D)*775(H)MM SEAT SHELL : The seat shell is a welded assembly of seat,back and side frame. The seat and back are made of 0.12+0.013cm thk CR steel sheet with oblong perforaCons. They are welded to sideframe of size 3.240.05cm x 0.5 + 0.05 cm thk HR steel. The welded assembly is powder coated ( DFT 40-60 microns ). The seat has a front water fall edge to provide popliteal clearance for comfortable seaCng. UNDERSTRUCTURE ASSEMBLY: Understructure assembly consists of connecCng beam and leg assembly made of M.S. E.R.W. oblong tube of size 7.5+0.03cm x 2.540.03cm x 0.2+0.016cm thk. The welded structure assembly is powder coated ( DFT 40-60 microns ).The leg assembly is | | fifed with shoes and levellers in Nylon. The leg structure is designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fifed to leg assembly help in aligning the structure for back to back arrangements. Levellers take care of uneven flooring.ConnecCng beam is fifed with snap locking end cap.It also aids in side-by-side understructure alignment. ARM REST ASSEMBLY: Armrest assembly consists of armrest frame and armrest pad . The armrest frame is made up of size 3.175+ £0.05cm x 0.4740.027cm thk HR steel and it is powder coated ( DFT 40-60 microns ). Armrest pad is injecCon molded in Nylon and is fifed onto the armrest frame.Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Storage 900X400X1800MM WITH FOUR FIXED SHELVES AND TRANSPARENT GLASS DOORS-BODY WILL BE 0.8MM THICK. THE DOOR SHALL BE 1.25MM THICK WITH TRANSPARENT GLASS LOCK OF 6 LEVERS WITH STAINLESS STEEL BY FABRICATED WITH MODERNIZED WORKSHOP .Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Two Seater Sofa Dim : 114.5 CM (W) X 63.8 CM (D) X 78.5 CM (H) SEAT SIZE : 47.8 cm (W) x 44.6 cm (D) * BACK SIZE : 41.6 cm (W) x 23.0 cm (H) SEAT SHELL : The seat shell is a welded assembly of seat,back and side frame. The seat and back are made of 0.12+0.013cm thk CR steel sheet with oblong perforaCons. They are welded to sideframe of size 3.240.05cm x 0.5 + 0.05 cm thk HR steel. The welded assembly is powder coated ( DFT 40-60 microns ). The seat has a front water fall edge to provide popliteal clearance for comfortable seaCng. UNDERSTRUCTURE ASSEMBLY: Understructure assembly consists of connecCng beam and leg assembly made of M.S. E.R.W. oblong tube of size 7.5+0.03cm x 2.540.03cm x 0.2+0.016cm thk. The welded structure assembly is powder coated ( DFT 40-60 microns ).The leg assembly is | | fifed with shoes and levellers in Nylon. The leg structure is designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fifed to leg assembly help in aligning the structure for back to back arrangements. Levellers take care of uneven flooring.ConnecCng beam is fifed with snap locking end cap.It also aids in side-by-side understructure alignment. ARM REST ASSEMBLY: Armrest assembly consists of armrest frame and armrest pad . The armrest frame is made up of size 3.175+ £0.05cm x 0.4740.027cm thk HR steel and it is powder coated ( DFT 40-60 microns ). Armrest pad is injecCon molded in Nylon and is fifed onto the armrest frame. Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Three Seater Sofa Dim :1675(L)*710(D)*775(H)MM SEAT SIZE : 47.8 cm (W) x 44.6 cm (D) * BACK SIZE : 41.6 cm (W) x 23.0 cm (H) SEAT SHELL : The seat shell is a welded assembly of seat,back and side frame. The seat and back are made of 0.12+0.013cm thk CR steel sheet with oblong perforaCons. They are welded to sideframe of size 3.240.05cm x 0.5 + 0.05 cm thk HR steel. The welded assembly is powder coated ( DFT 40-60 microns ). The seat has a front water fall edge to provide popliteal clearance for comfortable seaCng. UNDERSTRUCTURE ASSEMBLY: Understructure assembly consists of connecCng beam and leg assembly made of M.S. E.R.W. oblong tube of size 7.5+0.03cm x 2.540.03cm x 0.2+0.016cm thk. The welded structure assembly is powder coated ( DFT 40-60 microns ).The leg assembly is | | fifed with shoes and levellers in Nylon. The leg structure is designed with minimal area of contact close to ground providing easy access for cleaning purposes. The shoes fifed to leg assembly help in aligning the structure for back to back arrangements. Levellers take care of uneven flooring.ConnecCng beam is fifed with snap locking end cap.It also aids in side-by-side understructure alignment. ARM REST ASSEMBLY: Armrest assembly consists of armrest frame and armrest pad . The armrest frame is made up of size 3.175+ £0.05cm x 0.4740.027cm thk HR steel and it is powder coated ( DFT 40-60 microns ). Armrest pad is injecCon molded in Nylon and is fifed onto the armrest frame.Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Conference table of size:- 6000x1500x750mm. Top made in parts top made of twin layer 43mm (25+18mm) thick prelaminated MDF the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. Gable end made of 150mm thick prelaminated MDF the edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius..Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing Made of 25mmThick Pre-laminatedtwin board of E1- P2grade and approved shade confirmingto IS-12823:1990,Edge bandedwith matching 2mm thick PVC lipping. Leg :- 60 X 30 X 1.6 mm thick MS powder coated in texture Finish. Secondary, Made of 25mmthick MDF one side pre-aminate board confirming to IS-14587:1998with0.4mm PVC membrane pressed onto top.Soft closing access flap within-build power boxare provided on worksurface for wire management. Modesty Panel :Made of 25mm thick MDFonesidepre-laminate board confirming to IS- 14587:1998with0.4mm PVC membrane pressed on to top. Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
Supplying & Providing Overall Size 715W x 715D x 1250H . Good Quality Product Of High Back Chair Standard Models . Seat Plywood Made Of 15mm Hot Pressed . Upholstery PVC Structure Moulded With Prime Quality High Stretch Fabric Mesh . PHA ( Gas-Lift ) 85mm (TDC 152mm & BDC 67) . Seat & Back Are Firmly Connected To The Base Frame Machanism . Center Tilt Seat & Back are fixed together and the whole structure moves together in one direction . Machanism Provided Upright Position Locking . Tilt Adjustment Can Be Operated In Seating Position . Chair Max Height 1250 . 470W x 460D Base Seat 70mm Thick Moulded With PU Foam D - 45kg/m3 & 500W x 780H Back Seat PP Structure Moulded With Fabric Mesh . Headrest Adjustable Type PU Foam With PP Cover At Back . 415 Handle In / 590 Handle Out Arm Rest Fixed Type PP . Height From Seat To Ground 460mm . Height From Seat To Handle 160mm . Understructure Used Chrome Plated Steel Base With 3 Pieces Bellow . Casters Made Of Moulded Black Nylon Metal Bolt Inserted & Fitted With 5 Nos . Twin Wheel Casters 50mm Dia . Pedestral Pitch Centre Dia 665mm Without Casters .Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
STORAGE Model:- DA-Y-650 Size:- 900(W)x450(D)X1800(H)MM Proviidng Wooden Almirah partially glazed and partially open of size 900 x 450 x 1800 (WXDXH) made of prelaminated paricle board duly edge banded with 2mm thick PVC lipping. Aluminum beading is provided at the border supporting 5mm clear glass for glass shutters with necessary hardware fixture. The bottom part is made of prelaminated particle board having one adjustable shelf.Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing 6 compartment steel clothes locker, M.S Sheet conforming to commercial quality cr- 1.1980x910x480mm handle with ticket holders six lockers will have internal lock fitting and lockers shall be fitted with hasp and staple of overall sizes of lockers. Body made of 22 gauge CRCA sheet duly powder coated. Front made of 20 gauge CRCA sheet duly powder coated should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing The bench Top is made of PLPB. Top shall be supported on ms powder coated CRCA pipe frame having size of 25x25mm. The understructure shall consist of MS Powder coated square leg size of 25x25mm. There should be a shoe provide in the leg to avoid scratches on the floor. The seat size will be 1800x250mm, seat hight 450mm..Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
MODEL- DGS P7001 Model: DGS P7001 Executive office Desk with Side unitPLPB Board INTERIOR GRADE with 2/.8 mm thick Pvc Edgebanded Finish as per Approved laminate shade. Executive table Size 2400 mm w x 2100mm d x 750mm top made of 36mm thick, Gable end 36 mm thk with dual shade, Modesty panel 18mm thk PLPB Interior with as per image desgin, exposed edges covered with 2 mm pvc edge banding tape and non exposed edges covered with .8 mm thk pvc edge banding tape. Side Unit top 36mm thk Rest all 18mm thick PLPB Board Interior Grade, Fixed Drawer unit 2 drawer + 1 filling unit, Drawer slides telescopic channel with central locking systems s. all exposed edges covered with 2 mm pvc edge banding tape and non exposed edges covered with Back Unit Size - 2100mm w x 450mm d x 1800mm ht. All made of 18 mm thick PLPB Board Interior Grade Lower side one pedestal unit 2 drawer + 1 filling unit Open storage with Hinge door shutters with locking arrangement, . All All wooden panels, gableend,modesty and Storage fix joints with Minfix Dowels & Others fiting equipemnts. elves , D type handle, Exposed edges covered with 2 mm pvc edge banding tape and non exposed edges covered with .8mm thk pvc edge banding tape. Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
CENTER TABLE Model:- DCCT-7013 Size:- 1200(W)x600(D)X450(H)MM Providing and Placing Centre Table of size 1200Wx600Dx450H mm. Top is made of 18mm thick prelaminated particle board with duly edge banded with 2mm thick PVC lipping It is having provision of toughened glass on top, one Drawer & one shelf in table.
3 SEATER SOFA MODEL :- DSS 12003 Supplying and placing three seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing . The sofa shall have spring attached and also be padded separately. The frame should be padded with high resilence polyurethane foam having density 40 KG/m3 in seat and 32kg/m3 in back. There shall be SS tube arm provided with shiny chrome finish. The complete structure shall be upholstered with good quality leatherite tapestry 1+/-0.2mm thick and 571 GSM. The understructure shall be supported by 510 +/-10 mm (D)x1510 +/-10mm ( W), seat height = 430 mm . Overall width = 1770mm, overall depth =760mm and overall height = 750mm. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
Providing and Placing The Cubical workstation with partition thickness as 52.4 mm thk and ht - 1200 including powder coated aluminium trims. Tiles: Combination of top tiles are fabric magneitc/fabric tackable/ writing board tile. Bottom tiles -Plain metal. INTERMEDIATE BLOCKS Intermediate blocks are given in Fabric finsh. MODESTY PANELS WITH ASSEMBLY LEG - 25 MM THK PLB modesty has been given on the front of the main worktop which is attached to the partition on one end with gable end bkts and on the other end with metal powder coated frontier leg. legs - metal powder coated legs at the end and shared condition. System shall also have 120 mm high powder coated standalone panel legs to give the system an elevated look. Worksurface - Main table recta out of 25 mm thk prelam particle board with flat pvc lipping edge banding of size 1650 mm w x 750 mm d and ERU table recta of size 1200 mm w x 450 mm d. Pedestal - WISH pedestal flat metal front, full ht topShould be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
HDU 1219x1050x450 :-TOP:25mm thick PLPB board with 2mm thick PVCedge banding finish with as per approved laminate color. SHUTTER :18mm thick PLPB board with 2mm thick PVCedge banding.Finish with as per approved laminate color. STRUCTURE :18mm thick PLPB board with 2mm thick PVCedge banding.Finish with as per approved laminate color. SHELF :18mm thick PLPB board with 2mm thick PVCedge banding.Finish with as per approved laminate color.
Supplying and placing Table Made of 25mmThick Pre-laminatedtwin board of E1- P2grade and approved shade confirmingto IS-12823:1990,Edge bandedwith matching 2mm thick PVC lipping. Leg :- 60 X 30 X 1.6 mm thick MS powder coated in texture Finish. Secondary, Made of 25mmthick MDF one side pre-aminate board confirming to IS-14587:1998with0.4mm PVC membrane pressed onto top.Soft closing access flap within-build power boxare provided on worksurface for wire management. Modesty Panel :Made of 25mm thick MDFonesidepre-laminate board confirming to IS- 14587:1998with0.4mm PVC membrane pressed on to top. Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
Providing and Placing MD Table : Model :- DTD-15282 : Supplying and placing Table with side unit of size:- 2800(W)x2090(D)X750(H) MM The Table top is veneered 62mm comprised of 6 mm veneer plus 25 mm Top plus 25+10 mm baton of soid wood with backing decorated laminated thick coated with melamine and duco in sandwitch shape.LEGS:ain desk should contain wire management system and storage side unit Main desk should contain wire management system and storage side unit There is one side three drawer unit of size 480 mm (W) x640 mm (D) x600 mm (H). and the side unit of size 1100 mm (W) x480 mm (D) x550 mm (H). th side unit top is merged with the main table. Top surface of pedestal and ERU should be made of MDF board finished with veneer and final coat of PU. The modesty penel of size 200x600x18mm with veneer finish . The top, drawer unit and the side return unit should be joint with the help of steel studs of minimum 60mm dia stainless steel pipes . All the hardware are channels are used in the tales are standard good quality with branded like ebco or hatich make. There are two extra support of the bale with MS pipe of 150mm dia duly polished with duco in contrast colours . The Bottom legs are MS ERW round tube of diameter 50mm. x 1.6 mm. thick in chrome finish. All the raw material are being used in the tables shold be branded like marino/action tessa/greenlam.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
BACK UNIT Model:- DA-D-106 : Supplying and placing Size:- 2500(W)x450(D)X2000(H)MM : The back unit front sides and shelf are made of 18mm thick MDF board with 6mm veneer with duly melamine finish with final coat of PU. the back panel is made of 12mm thick mdf with 4mm veener with melamine finish. The storage is in two parts in bottom part there are two storage with openable shutter and one shelf making two compartment. The upper portion has two shelf with middle partition with sliding doors of transparant aluminium profile of 50mmx15mm with 5mm clear glass. The storage is lockable with branded locks and handles like hatich/ebco. All the hardware is used with good quality and branded. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
HIGH BACK CHAIR Model:- DBS 1031 Supplying High Back Chair Overall Size 720W x 720D x 1125H . Seat & Back Plywood Made Of 15mm Thick Hot Pressed . Upholstery PVC Structure Moulded With PU Foam High Quality Leatherite . PHA ( Gas-Lift ) 105mm (TDC 171mm & BDC 66) . Seat & Back Are Firmly Connected To The Base Frame Machanism . Machanism Provided Upright Position Locking Syncro Knee Tilt Four Time Locking System . Tilt Adjustment Can Be Operated In Seating Position. 540W x 525D Base Seat 80mm Thick Moulded With PU Foam D - 45kg/m3 , H-20 Letherite & 500W x 725H x 80mm Thick Back Seat Ply Structure Moulded With PU Foam Letherite . Arm Rest Fixed Type SS 304 Grade Structure Base Plate 60W x 5mm Thick Moulded With PU Foam Leatherite . 520 Handle In / 655 Handle Out Arm Rest Fixed Type PU Foam Letherite SS Chrome Plated Structure . 75W x 12mm Thick MS ( L ) Patta Powder Coated Firmly Connected With Seat & Back . Height From Seat To Ground 400mm . Understructure Made Of Fan Base Steel & MS Plate Inserted Chrome Plated SS Finished With 3 Piece Bellow . Fan Base System Understructure Moulded With Letherite Upper Side. PVC Hub Fixed With Understructure Chrome finished . Alloy Wheels Type Casters Made Of Moulded Black Nylon Metal Bolt Inserted & Fitted With 5 Nos . Twin Wheel Casters 50mm Dia. Pedestral Pitch Centre Dia 720mm With Casters & Without Casters 640mm.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
VISITOR CHAIR (WITHOUT REVOLVING) Model:- DBS 1032 Supplying Visitor Chair Overall Size 480W x 560D x 945H . Seat & Back Plywood Made Of 12mm Thick Hot Pressed . Upholstery Ply Structure Moulded With PU Foam High Quality Leatherite. 540W x 525D Base Seat 80mm Thick Moulded With PU Foam D - 45kg/m3 , H-20 Letherite & 500W x 725H x 80mm Thick Back Seat Ply Structure Moulded With PU Foam Letherite . Arm Rest Fixed Type SS 304 Grade Structure Base Plate 60W x 5mm Thick Moulded With PU Foam Leatherite . 520 Handle In / 655 Handle Out Arm Rest Fixed Type PU Foam Letherite SS Chrome Plated Structure . 75W x 12mm Thick MS ( L ) Patta Powder Coated Firmly Connected With Seat & Back . Height From Seat To Ground 470mm . Understructure Seat & Back Firmly Connected To The Base Frame Structure 32mm Dia Round Pipe 16 Guage Thick MS Pipe Chrome Finished . All MS Round Pipe Pieces Shall Be Welded Properly Strongly and conformity with regulations . Legs Of The Chair Hard Rubber Shoes.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
3 SEATER SOFA Model:- DSS 12007 Supplying and placing three seater sofa that constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allowfor the heavy tension webling. The sofa shall have spring attached and also be padded saperately. The frame shall be padded with high resilence polyeurethine foam having density of 40kg/m3 in seat and 32kg/m3 in back. There should be a cusion arm should be provided padded with high resilience polyeurathine foam having density of 40kg/m3. The structure shall be upholstered with leatherite tapestry of 1+/- 0.2 mm thick and 571 gsm. The sofa shall be supported on ms powder coated frame having size of 40x20mm. The understructure shall consist of MS Powder coated round leg with upper dia 38mm and lower dia 32mm. There should be a shoe provide in the leg to avoid scratches on the floor. The seat size will be 570x1660mm, seat hight 425mm.. The overall dimention of the sofa is 2020x750x680 (+/-10mm) (WDH). The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
2 SEATER SOFA Model:- D Supplying and placing three seater sofa that constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allowfor the heavy tension webling. The sofa shall have spring attached and also be padded saperately. The frame shall be padded with high resilence polyeurethine foam having density of 40kg/m3 in seat and 32kg/m3 in back. There should be a cusion arm should be provided padded with high resilience polyeurathine foam having density of 40kg/m3. The structure shall be upholstered with leatherite tapestry of 1+/- 0.2 mm thick and 571 gsm. The sofa shall be supported on ms powder coated frame having size of 40x20mm. The understructure shall consist of MS Powder coated round leg with upper dia 38mm and lower dia 32mm. There should be a shoe provide in the leg to avoid scratches on the floor. The seat size will be 570x1100mm, seat hight 425mm.. The overall dimention of the sofa is 1490x750x680 (+/-10mm) (WDH). The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
VISITOR CHAIR MODEL :- DBS 1023 Supplying and placing ergonomically design, comfirtable and aesthetically appealing Mid Back non revolving Chair. The seat and back shall be made of 15mm thick hot pressed commercial plywood padded with high resilience polyurethane foam of 60 mm thick having density 40 KG/M3. The same shall be upholstered with leatherite tapestry o.8mm thick and 535 gsm. The back rest of the chair shall be made by keeping the natural curvature of spine as well as head support . The arm rest are made up of aluminium di casted with padded cushion and leatherite upholstry . The understructure of the chair is 40x20mm eleptical crca pipe duly powder coated The seat size shluld be 515x490mm and back side should be 510x580 mm from seat and overall height 1040mm. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
Table Model :- DCCT 7004 Supplying and placing Understructure of the table which includes legs and under support is made of stainless steel square tube of size 25x25 mm with thickness of 1.2mm. The top is 12mm thick plain toughened glass.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Table Model :- DCCT 7007 Supplying and placing Understructure of the table which includes legs and under support is made of stainless steel square tube of size 25x25 mm with thickness of 1.2mm. The top is 12mm thick plain toughened glass.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Café Table, Dia. 900mm, Supplying and placing Understructure of the table which includes legs and under support is made of stainless steel square tube of size 25x25 mm with thickness of 1.2mm. The top is 12mm thick plain toughened glass.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Each Body Size: 915(W)x450(D)x2080(H) mm Total 08 Nos. of Bodies in Compactor Providing & Fixing Compactor of ht 2080mm. The side, back & top of the box is made of 0.8 thick (22 gauge) prime quality CRCA sheets. The body has independent precision punches slotted strips welded at corners to support the shelves to ensure flexibility in adjusting the height of the shelves. Shelves are made of 0.8mm thick prime quantity mild steel having 8 folds each designed to carry UDL of 60 kgs. The shelf is fixed to the compactor body by means of a support bracket, which facilitates adjustment of shelf as 25mm pitch. System is provided with centralized locking arrangement on the last unit when all the units are brought together, central lock when operated gets locked with the plate which is welded to the rail and does not allow access to the units. The compactors shall consist of single face static unit at one end and double face mobile unit in middle and single face mobile unit at other end with extension of pair of rail for movement of mobile units. The movement of mobile units shall be control with driving mechanism, operated from side with help of driving wheel.
Steel Almirah Model : DSS 5522 Size :- 915(W) x 480(D) x 1980 MM(H) Supplying and placing Wardrobe plain shall have an overall size of 915mm(W)x480mm(D)x1980mm(H) with welded constuction. It should have the shelf thickness of 22mm, Back thickness of 0.8mm, Door thickness of 1mm (high yield strenght) and all other components shall have a thickness of 0.8. These components shall be made of CRCA 'D' grade high yield stength as per IS:513. The storewel palin should have a mazak handle and three way machanism with shooting bolts type leveller with hex plastic base. The finising shall include epoxy powder coated to the thickness of 50 microns )+/-10). plenty of color option and shelving options shall be available. Lock :- Steel Almirah with Two Key. (Dual Lock)
MEETING TABLE Model:- DCS 9507 Size:- 3600(W)x1500(D)X750(H)MM . Supplying and placing conference table in completely knock down condition that is to be assembled at site. The construction of the main table shall be free standing structure constructed with the help of minifix dowls pins and brackets. The work top shall have the combination of Pre laminated particle board and MDF board. The main top should be made up of back to back 18mm thick pre laminated particle board of grade II of IS 12832 with approved laminate and the base top shall be made upof 25mm thick MDF board with decorative matt finish. The table top profile shall be boat like shape with round corners. The edges shall be sealed with 2mm thick thin strip of impermeable pvc ie cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 deg celcious. The base top shall be half round with grooves. Single sided flapper box should be enclosed on the table top that houses vedio, audio, data and power connection discretely. Wire carrier shall be provided below the table top for power connection made of 0.8mm thick high yeald strength crca sheet of grade D confirming to IS : 513. The table shuld be supported on particle board base gable end. The end wall of the table on the side and mid shall be toped by gable end. It should be made up of 25mm thick prelaminated particle board . The table shall be clad with 18mm thcick modesty penel wich provide structural support to the table. There should be buffer provided at the base to avoided scratches on the floor. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
Model :- DCT-3014 Size :- 750W X 750 D X 750 H Providing and placing Cafeteria table having of top is 750W X 750 D X 750 H. Table top made of 19mm commercial board with 1mm thick laminate duly edge banding in support of two cross section pipe. The height of table will be 750mm and the middle pillor is made of Stainless Steel with 65mm dia of 16 gaugse. The base of table frame will be in high duty stainless steel or in dicast iron base duly chrome finish. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Cafeteria Chair Model :- DCS 5060 Providing and placing Cafeteria chair having size of 840(H)x435(L)x435(W) Seat, legs & connectors is made of polypropylene Alloy,
Providing and placing in position book racks. Overall size of the rack shall be 1875 W X 360 D X 2285 H . Rigid Knockdown construction,Material used shall be CRCA 0.8mm thick. Number of adjustable shelf shell be six with total all loading levels. Uniformly distributed load capacity per each shelf is 80kg maximum. Shelf back stiffenerat the rear end of the shelves shall be provided. These are to support books on the rear side. Label holder & range indicator oneach main unit for inserting labels.Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Providing and placing in position book racks. Overall size of the rack shall be 1875 W X 560 D X 2285 H . Rigid Knockdown construction,Material used shall be CRCA 0.8mm thick. Number of adjustable shelf shell be six with total all loading levels. Uniformly distributed load capacity per each shelf is 80kg maximum. Shelf back stiffenerat the rear end of the shelves shall be provided. These are to support books on the rear side. Label holder & range indicator oneach main unit for inserting labels.Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Supplying and placing Station table size of 860 D x 1100 H. desk counter height is 750mm, All in 25mm thick PLPB with 2mm PVC edge banded on all edges. 1 drawer unit all in 18mm thick PLPB, counter with Key board tray. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Supplying and placing Station table size of 860 D x 1100 H. desk counter height is 750mm, All in 25mm thick PLPB with 2mm PVC edge banded on all edges. 1 drawer unit all in 18mm thick PLPB, counter with Key board tray. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Supplying and placing 6 compartment steel clothes locker, M.S Sheet conforming to commercial quality cr- 1.1980x910x480mm handle with ticket holders six lockers will have internal lock fitting and lockers shall be fitted with hasp and staple of overall sizes of lockers. Body made of 22 gauge CRCA sheet duly powder coated. Front made of 20 gauge CRCA sheet duly powder coated should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Supplying and placing Station table size of 860 D x 1100 H. desk counter height is 750mm, All in 25mm thick PLPB with 2mm PVC edge banded on all edges. 1 drawer unit all in 18mm thick PLPB, counter with Key board tray. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Supplying and placing Station table size of 860 D x 1100 H. desk counter height is 750mm, All in 25mm thick PLPB with 2mm PVC edge banded on all edges. 1 drawer unit all in 18mm thick PLPB, counter with Key board tray. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Supplying and placing 6 compartment steel clothes locker, M.S Sheet conforming to commercial quality cr- 1.1980x910x480mm handle with ticket holders six lockers will have internal lock fitting and lockers shall be fitted with hasp and staple of overall sizes of lockers. Body made of 22 gauge CRCA sheet duly powder coated. Front made of 20 gauge CRCA sheet duly powder coated should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
2 SEATER SOFA MODEL :- DSS 12003 Supplying and placing three seater sofa that shall be constructed from natural hard wood and commercial plywood having inner frame. The thickness of the wood should allow for the heavy tension webbing . The sofa shall have spring attached and also be padded separately. The frame should be padded with high resilence polyurethane foam having density 40 KG/m3 in seat and 32kg/m3 in back. There shall be SS tube arm provided with shiny chrome finish. The complete structure shall be upholstered with good quality leatherite tapestry 1+/-0.2mm thick and 571 GSM. The understructure shall be supported by 510 +/-10 mm (D)x1110 +/-10mm ( W), seat height = 430 mm . Overall width = 1370mm, overall depth =760mm and overall height = 750mm. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified.
Table Model :- DCCT 7004 Supplying and placing Understructure of the table which includes legs and under support is made of stainless steel square tube of size 25x25 mm with thickness of 1.2mm. The top is 12mm thick plain toughened glass.The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Cafeteria Table Model :- DCT 3017 Size :- 900 MM DIA Providing and placing Cafeteria table having diameter of top is 900mm . Table top made of 19mm commercial board with 1mm thick laminate duly edge banding in support of two cross section pipe. The height of table will be 750mm and the middle pillor is made of Stainless Steel with 65mm dia of 16 gaugse. The base of table frame will be in high duty stainless steel or in dicast iron base duly chrome finish. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Total Height from floor : 1000 mm+/- 10mm Width centre to centre : 550 mm+/- 10mm Depth : 760 mm +/- 10mm Seat Height : 450 mm+/-10mm Arm Height : 610 mm +/- 10mm Side leg : 50x2 mm MS Chanel Grouting supporting Plate welded : 80x305x1.6 mm with 2 Hole , Deep draw moulded foot rest. Back Assembly:- The back made in PU Foam inserted CR Pipe 19x2mm Supported by Nylon Strip. Back size is 710x460x110 mm with covered by PPCP cover. The chair is provided with a Fix back/ Flexi back and seat Auto tip up with 2 rivers spring and tension spring Mechanism. Seat assembly :- The seat is made of PU foam upholsters with fabric 100% polyester and inserted CR pipe 19x2 mm. Supported by 25x3 mm flat, Seat Size 480x450x150mm. With covered by PPCP cover. Arm Rest:- The armrest is made PU/PP Arm with cup holder/ without cup holder and wooden arm. Powder Coating:- All metal components are powder coated in black colour 70-80 micron. Should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC, AIOTA & ISO 9001:2015 and ISO 14001:2015.
4 Seater Canteen Table Model :- DCT 3015 Size :- 1200(W)*600(D)*750(H) MM Providing & Placing Cafeteria table. Top made in 25mm thick prelaminate particle board of approved shade. All exposed edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius with necessary supports beams & base made of 60 x 60 mm SS sq.pipe with base plate of size-750x380mm in SS. The participating brand must have ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
Supplying and placing 6 compartment steel clothes locker, M.S Sheet conforming to commercial quality cr- 1.1980x910x480mm handle with ticket holders six lockers will have internal lock fitting and lockers shall be fitted with hasp and staple of overall sizes of lockers. Body made of 22 gauge CRCA sheet duly powder coated. Front made of 20 gauge CRCA sheet duly powder coated should be compliance with BIFMA,/ANSI/BIFMA-3, Greenguard compliance IGBC & ISO 9001:2015 and ISO 14001:2015.
Supplying and placing Station table size of 860 D x 1100 H. desk counter height is 750mm, All in 25mm thick PLPB with 2mm PVC edge banded on all edges. 1 drawer unit all in 18mm thick PLPB, counter with Key board tray. Should be compliance with ISO-9001/14001/45001/50001 and Bifma membership and AIOTA , IGBC and Green guard certified
HANDRAIL, CRASHRAIL AND CORNER GUARD
Providing & Fixing 150 series high impact resistant surface mount Corner Guard having VinylSnap on cover (Lead Free) of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers No plasticizers shall be added (plasticizers may aid in bacterial growth). Surface shall have a Pebblette texture for scratch resistance. Continuous Aluminum Retainer of .070" (1.8mm) thickness shall be fabricated from 6063-T5 aluminum, with a mill finish. Dimensions to be of 3" (76mm) x 3" (76mm), 90 degree. The rigid vinyl profile shall resist an Impact Strength of 30.2 ft-lbs/inch as per ASTM D-256-90b and shall cis not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance. It includes Top caps and bottom caps which shall be made of injection molded thermoplastics.
Providing and fixing 700 series superior impact resistance Wall Guard Vinyl (Lead Free) Snap on cover of .080" (2mm) thickness shall be extruded from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers. No plasticizers shall be added (plasticizers may aid in bacterial growth) cis. Surface shall have a Pebblette texture for scratch resistannce and Continuous aluminum retainer of .080" (2mm) thickness shall be fabricated from 6063-T5 aluminum, with a mill finish. Dimensions to be of 7 3/4" (197mm) height x 1" (25mm). Inner snap-on vinyl impact black bumper of .080" (2mm) thickness x 3.930" (100mm) width x 21mm height which shall be extruded from chemical and stain resistant unplasticized polyvinyl] chloride (uPVC). The system shall resist an Impact Strength of 45.5 ft-lbs/inch while producing no visual blemishes upon the vinyl cover surface and no deformations in the aluminum retainers, as tested in accordance with applicable provisions of ASTM F 476-84, paragraph 18, Impact Test and shall not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance. It shall include standard quantity, as per manufacturer, of Molded End Returns.
Providing and fixing 3110 series Handrail with integrated vinyl wall guard having Rigid Vinyl Snap-on cover (Lead Free) of .080" (2mm) thickness extruded from chemical and stain resistant unplasticized polyvinyl chloride (uPVC) with the addition of impact modifiers. No plasticizers shall be added (Plasticizers may aid in bacterial growth). Surface shall have apebblette texture for scratch and stain resistant with rigid vinyl cover mounted on a sturdy continous Aluminium Retainer of .080" (2mm) thickness that shall be fabricated from 6063- T5 Aluminium with a mill finsh. Dimesnions to be 6-1/8 " (155mm) height x 1-1/2" (38mm) full round gripping diameter, system extends 3-1/8" (79mm) from the wall. Integrated vinyl cover, 4" (101mm) high. Inner snap-on vinyl impact black bumper of .070" (1.8mm) thickness and 2-1/4" (57mm) high shall be extruded from chemical and stain resistant unplasticized polyvinyl] chloride (uPVC). The system shall resist an Impact strength of 45.5 ft-lbs/inch while producing no visual blemishes upon the vinyl cover surface and no deformations in the aluminum retainers, as tested in accordance with applicable provisions of ASTM F 476-84, paragraph 18, Impact Test cis. The rigid vinyl shall not support fungal or bacterial growth inaccordance with ASTM G-21 and G-22. The system shall also conform to class A fire rating and ASTM D-543 for chemical and stain resistance.It shall include standard quantity, as per manufacturer, of Molded Mounting Brackets/end returns.
SIGNAGE WORK
Providing and fixing Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back. 4 Inch X 12 Inch
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 2 Feet
Providing and fixing Backlit Acrylic Box Lit with Korean Led .2 Feet by 1 Feet
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter as required.2 Feet by 4 Feet
Providing and fixing Backlit Acrylic Box Lit with Korean Led .2 Feet by 1 Feet
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.2 Feet by 2 Feet
Providing and fixing Frosted Film.8 Feet by 8 Feet
Providing and fixing Laser Cut 5 mm Acrylic Letters with Pasted over 5 mm Acrylic Sheet with 6 studs.4 Feet by 3 Feet
Providing and fixing Laser Cut 5 mm Acrylic Letters with Pasted over 5 mm Acrylic Sheet with 6 studs.2 Feet by 1 Feet
Providing and fixing Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required.4 Feet by 2 Feet
MODULAR OPERATION THEATRES
Supply & Installation of Walls Construction of SS 304 puff panel .8 mm sheet both side with 50 mm thick puff with paint on front side as per technical specification and make list enclosed
Ceilling for Operating room with paint as per tender technical specification and make list enclosed for
Planair Ceiling (Plenum box – Air Diffuser) – (cladding type OT) duly CE Marked as per technical specification and make list enclosed for MOT size 2400 MM x 2400 MM minimum
Double peripheral lights-Indigenous – (cladding type OT) as per technical specification and make list enclosed
Touch Control Panel with with screen not less 22 "– Imported as per technical specification and make list enclosed
X-ray Viewing Screen – (cladding type OT)(Indigenous) as per technical specification and make list enclosed
Static dissipative Flooring (Tile Form) – (cladding type OT)(Imported) as per technical specification and make list enclosed
Scrub Station – (cladding type OT)(Indigenous) as per technical specification and make list enclosed
Mobile OT LIGHT -(imported) as per technical specification and make list enclosed european CE notafied body no / FDA approved 120000 Lux - 1no for minor OT
Automatic Sliding Door– as per technical specification and make list enclosed imported for MOT
Writing Board with magneting system Size:- 1000x700x60 Deep made out G.P Sheet to be flushed with the wall system complete set as per technical specification and make list enclosed
Cascade Pressure stabiliser having muliti 304 grade stainless steel blade to control the room air pressure as per technical specification and make list enclosed
Srorage unit size 1666 x 865 x 350 having two shelves & made of zinc passivated steel having 5mm thick glass door & mounted flush with the theatre wall as per technical specification and make list enclosed
RIGID PENDENT – (imported) as per technical specification and make list enclosed
Hatch box 600 mm x 600 mm as per technical specification and make list enclosed
Orthopedic motorized OT table as per technical specification and make list enclosed
Refraction Unit with motorized drum n stool as per technical specification and make list enclosed
IV stand as per technical specification and make list enclosed
equipment trolley as per technical specification and make list enclosed
Electrical Wiring inside OT as per technical specification and make list enclosed
AHU DUCTING inside MOT (only ducting work within OT ) as per technical specification and make list enclosed
MINOR OPERATION THEATRES
Supply & Installation of Walls Construction of EGP puff panel .6 mm sheet both side with 40 mm thick puff with paint front side as per technical specification and make list enclosed
Ceilling for Operating room as per tender technical specification and make list enclosed for
Planair Ceiling (Plenum box – Air Diffuser) – (cladding type OT) duly CE Marked as per technical specification and make list enclosed with 1800 mm x 1800 mm minimum
Double peripheral lights-Indigenous – (cladding type OT) as per technical specification and make list enclosed
Static dissipative Flooring (Tile Form) – (cladding type OT)(Imported) as per technical specification and make list enclosed
LED OT LIGHT -(indian) 120000 as per technical specification and make list enclosed
Automatic Sliding Door– as per technical specification and make list enclosed indian for minor OT
Writing Board with magneting system Size:- 1000x700x60 Deep made out G.P Sheet to be flushed with the wall system complete set as per technical specification and make list enclosed
Cascade Pressure stabiliser having muliti 304 grade stainless steel blade to control the room air pressure as per technical specification and make list enclosed
Srorage unit size 1666 x 865 x 350 having two shelves & made of zinc passivated steel having 5mm thick glass door & mounted flush with the theatre wall as per technical specification and make list enclosed
RIGID PENDENT – (imported) as per technical specification and make list enclosed
Orthopedic motorized OT table as per technical specification and make list enclosed
Refraction Unit with motorized drum n stool as per technical specification and make list enclosed
IV stand as per technical specification and make list enclosed
equipment trolley as per technical specification and make list enclosed
Electrical Wiring inside OT as per technical specification and make list enclosed
AHU DUCTING inside MOT (only ducting work within OT ) as per technical specification and make list enclosed
NURSE CALL SYSTEM
Supply, Installation, Testing & Commissioning of UL 1069 certified and USFDA approved (Bed Side Modules-Non-Speech) for each patient location.The basic features on all patient bed side modules should be consider and covered as under Patient call, Staff Presence, Staff Assist Beds, Code Blue, Code Blue Protection for any mis-handling by anyone, Emergency, Staff assist toilet, over door light and management /patient reports features and these features should be mandantory by any OEM.
Supply, Installation, Testing & Commissioning of UL certified and USFDA approved (Patient Bed side Handset/Call Cord--Non-Speech).Ergonomic, palm-sized pendant with bed clip, Durable fully moulded fittings, Integrates with most existing nurse call systems Embossed Braille characters for the visually impaired Choice of button colour and cable length The call pendants have been ergonomically designed, ensuring the devices are easy for patients / residents to hold and activate. The button is available in a choice of colours and the entire pendant is manufactured from impact-resistant plastic that is durable and easy to clean. A pendant removal alarm ensures instant notification that a pendant is not available for your patient, reducing downtime The pendant is suitable for use by left and right handed patients and residents The casing is manufactured from white, durable, impact-resistant plastic. The cable has a strong, moulded plastic, right-angle plug that connects to any callpoint with a 6.5mm pendant socket. The easy release design protects the callpoint socket, pendant plug and cable from damage should the cable be placed under severe tension, such as moving the bed with the pendant still connected
Supply, Installation, Testing & Commissioning of UL 1069 Certified and USFDA Approved (Corridor Nursing Station Annuciator/Display) 12 chracters corridor Annuciator 50 mm (1.97 in high character display to get alam by clinical staff too on priority basis..Custom designed messageDots show number and level of pending calls: Green x Patient Call, Orange x Staff Assist, Red x Emergency This high resolution, alphanumeric LED Annunciator provides audio and visual notification of active calls by means of text messages with accompanying alert tones based on priority. This IP-based device allows text messages, colours and tones to be completely configured for your facility. Multiple Annunciators may be connected anywhere on the LAN The alert tones and message colours for all call priorities can be customised to suit your facility.The Annunciator can be programmed to display messages from multiple areas, allowing calls to go to a specific ward displays and higher priority calls to go to adjacent ward or floor displays as required.Additionally, the Annunciators support ‘Ward Swinging’, allowing all calls from one ward to be diverted to a group of Annunciator displaysThe Annunciator uses 50mm tall, high-efficiency LED modules with a high resolution that ensures messages are easy to read from a distance of up to 20mThe Annunciator uses proportional fonts so that charactersare only displayed at their required width rather than a fixed width. On average, the Annunciator displays 12 characters and automatically scrolls longer messagesThe area to the right of the Annunciator displays a bar graph of the number of active calls. Three vertical columns (red, orange and green) graphically display the type and number of pending calls.
Supply, Installation, Testing & Commissioning of UL 1069 Certified and Approved USFDA (Staff Presence Modules) at every door side in every patient room/wards to acknowledge the patient call and automatically call gets cancel and change the status of the calls by pressing Staff Presence and enable clinical staffs for any emergency of staff assist beds, Code Blue, staff assist toiltes etc
Supply, Installation, Testing & Commissioning of UL 1069 Certified and USFDA Approved (3 LED CORRIDOR LAMPS) lights easy-to-see visual annunciation and these devices are typically installed in corridors and outside patient rooms to provide staff with a visual indication as to the origin of a call placed on the system.
Supply, Installation, Testing & Commissioning of UL 1069 Certified and USFDA Approved (EMERGENCY PULL CORD) in Patient Toilet area Water resistant, wall or ceiling mounted callpoints having IP65 rated and that initiate calls on the Nurse Call System. The cord has a wipe-cleansurface and has its own strain relief to ensure reliable operation without any possibility of damage. Manufactured from an impactresistant polycarbonate / ABS plastic, all Pull Cord The pull cord incorporates a weak-link break point as a safety measure. The pull cord can support up to 2 kg (4.416 lbs) ofweight before it will break apart..
Supply, Installation, Testing & Commissioning of UL 1069 Certified and USFDA Approved (EMERGENCY PUSH BUTTON) in Patient Toilet area Water resistant, wall or ceiling mounted callpoints having IP65 rated and that initiate calls on the Nurse Call System. The cord has a wipe-cleansurface and has its own strain relief to ensure reliable operation without any possibility of damage. Manufactured from an impactresistant polycarbonate / ABS plastic, all Pull Cord The pull cord incorporates a weak-link break point as a safety measure. The pull cord can support up to 2 kg (4.416 lbs) ofweight before it will break apart..
Supply, Installation, Testing & Commissioning of complete Patient Reporting Software/licenses of Nurse Call System including Power supply, Room Controllers, Network switches The Staff Station console that provides audio visual annunciation and display of alarms/calls received from any bed station or other callpoint on an nursing station display. The nature, location and level of priority of each alarm/call is indicated by plain text on the console display and is accompanied by distinctive alarm/call alert tones for each priority of alarm/call. The same information is available for output to corridor annunciator displays, Centralised display, logging and reporting » Displays active calls, alarms and system errors » Easy to use, sort and print data » Date and time stamped reportsDisplays all active nurse call alarms and system error messages on the computer monitor if required. • Logs all alarms/calls and events on the nurse call system. Software should be installed on a dedicated PC typically located in an administration office /Nursing director room
CURTAIN & IV HANGER SYSTEM
Supply, Installation, Testing & Commissioning of Curtain & IV Track System complete with following as per technical specifications attached.
Providing and installation of Cubical tracks system made of Powder coated Aluminium alloy, mounted on the ceiling using Suspension hangers and bushes, powder coated wall bracket and Track Joiners wherever required. This system shall be complete with stain free polyster fabric, Water repellent Curtains having 18" Net on top. The curtain shall be approx 7X4 feet, with two curtains stiched together wherever required. Curtains shall also be provided with smooth movement, non sticking runners, with Stainless steel hooks, for easy movement. The system shall have curtain removal points and end cap complete as per technical specifications wherever is required.
Providing and installation of I.V. Hanger with 5 hooks, made from mirror finish stainless steel, 304 grade with adjustable height, provided with 4/6 feet aluminium alloy track powder coated with endcap of tracks, 1 pc of trolley for smooth IV Hanger movement on track, 2 pcs of suspension hanger powder coated, top & bottom bush, powder coated, for easy fitting and better aesthetics complete as per technical specifications is required
Supply, Installation, testing & commissioning CSSD
HORIZONTAL RECTANGULAR HIGH PRESSURE HIGH VACUUM RADIAL DOUBLE DOOR STEAM STERILIZER, FULLY AUTOMATIC CYCLE OPERATION WITH ACCESSORIES, 250 litres capacity with One No. SS 316 carriage and 2Nos. SS 304 trolley as per technical specifications and make list
HORIZONTAL CYLINDRICAL HIGH PRESSURE HIGH VACUUM DOUBLE DOOR STEAM STERILIZER, FULLY AUTOMATIC CYCLE OPERATION, 250 Liters capacity as per technical specifications and make list
ETO Capacity 90-100 ltrs Inner Dimensions : 305X450X610 Power: 1.5 KVA Designed at 230 V as per technical specifications and make list
HORIZONTAL CYLINDRICAL HIGH PRESSURE HIGH SPEED INSTRUMENT STEAM STERILIZER (FLASH STERILIZER),79 Liters capacity as per technical specifications and make list
SS Work Table with Double sink as per technical specifications and make list
Spray Gun Rinser with Eight Attachments as per technical specifications and make list
Washer Disinfector with inbuilt drier, Double Door, 275 litres as per technical specifications and make list
Ultrasonic Cleaner, 30 litres as per technical specifications and make list
SS Control & Packing Table as per technical specifications and make list
Gauze cutting machine with table as per technical specifications and make list
Continuous band sealers with SS table as per technical specifications and make list
SS pass box as per technical specifications and make list
SS Table trolley with two shelf as per technical specifications and make list
SS Storage racks with five shelves as per technical specifications and make list
Add 18% GST
Add 1% Labour cess 1%
HEIGHTEN CONSTRUCTIONS
kmv projects limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.