Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Lowest Amount | |
| 2 | L2₹31.1 L+₹2.7 L (9.66%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance Not reasonable | |
| 3 | L3₹33.8 L+₹5.5 L (19.3%)Rejected-Finance | L3 | Rejected-Finance Not reasonable | |
| 4 | Rejected-Technical 12 NO 12 IRATTAI PILLAYAR KOVIL STREET NEAR REAL VALUE FLAT VELACHERY 733 CHENNAI TAMIL NADU 600042 | CHENNAI | TAMIL NADU | 600042 | - | Rejected-Technical Not enlisted in tender work categories. | |
| 5 | Rejected-Technical SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | - | Rejected-Technical Not enlisted in tender work categories. |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj N P Singh
GE (West) Colaba, Mumbai
MAINTENANCE OF SWIMMING POOL, FILTERATION PLANT AND REPAIR / REPLACEMENT OF ACs, COOLING APPLIANCES INSTALLED AT ARMY AREA UNDER GE WEST, MUMBAI
2020_MES_404602_3
8499/E8
Open Tender
Civil Works
Item Rate
330 days
GE (West) Colaba
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West)
₹56,000
Yes
10 Mar 2021
12 Feb 2021
24 Feb 2021
12 Feb 2021
22 Feb 2021
13 Feb 2021
60 days
Amount
M & L for descalling the condenser unit, shell and tube type of 8.5 TR capacity AC plant by means of circulating the descalling chemical through condenser by pressure feeding method after disconnecting condenser water lines, opening the end covers, scraping/cleaning the condenser water tubings, removing the scales and refixing the dismantled part, end cover with 3 mm thick rubber gasket set connecting with the system etc complete all as specified and directed.
All as per Sr item No. 1 but Condenser unit of capacity 5.5 TR
M & L for disconnecting/dismantling (electrically & mechanically) the 03 HP capacity monoblock pump and tranporting to workshop, opening the pump motor, cleaning the pump, greasing to bearing/bushes, replace the gland rope, gland nut bolt, opening motor, varnishing to stator winding with class I varnish, heating baking the same, greasing to motor bearing, cleaning the rotor and re assembling the same, brought back at site, fixing it at its original location with proper alignment and testing complete all as specified and directed.
Taking out carefully detoriated GI sheet duct from its existing location and supply, assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc. complete of size 22 guage to match with existing duct complete all as specified and directed.
M & L in replacement of solenoid pilot control valve coil assembly, 11 watt, 230 volt AC, type 6, size 2, as per OEM complete all as specified and directed.
M & L in replacement of HP/LP cut off switch MP -15 suitable for working on R-22 gas complete with flare nut complete all as specified and directed.
M & L in replacement of water pressure cut out, 1 PSI as per site requirement complete all as specified and directed.
M & L in replacement of LP/OP pressure guage, dial size 100 mm dia of rating 30 to 150 PSI suitable for working on R-22 gas with flare nut.
M & L in replacement of high pressure guage dial size 100 mm dia of rating 0.300 kg/cm2 suitable for working on R-22 gas with flare nut complete all as specified and directed.
M & L in replacement of oil pressure cut off switch , MP- 55, suitable for working on R-22 gas with flare nut complete all as specified and directed.
M & L in replacement of water pressure guage dial size 100 mm dia, 0-7 PSI rating complete all as specified and directed.
supply and fixing in repairs sealed unit compressor of approved make and capacity 230V, AC for window/split AC of capacity 1.5 TR all as specified and directed. Note:- Refrigerant gas will be measured and paid seperately under respective item of this schedule 'A' as supply only.
All as per Sr item No. 12 Compressor for Window/split type AC of capacity 2 TR .
All as per Sr item No. 12 Compressor for refrigerator of capacity 165 to 180 ltr .
All as per Sr item No. 12 Compressor for refrigerator of capacity 286/310 ltr .
All as per Sr item No. 12 Compressor for water cooler of capacity 40/80 ltr .
Taking out old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically and electrically and S & F new sealed unit compressor of capacity 3 TR working on 415 volts, 50 Hz, AC supply of approved make complete all as specified and directed. Note:- Refrigerant gas will be measured and paid separately under respective items of this schedule 'A'
Supply and fixing in repairs cooling coil unit of 1.5 TR capacity spilt AC 230 V AC of existing (dismantled) model or equivalent approved by Engineer-in-charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging complete all as specified and directed.
All as per Sr item No. 18 above but suitable for 2 TR capacity, split AC 230 V AC.
Supply and fixing in repairs condensor unit suitable for 1.5 TR split AC consisting of body, motor, condensor & blade suitable for existing (dismantled) model or equivalent and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging complete all as specified and directed.
All as per Sr item No. 20 above but suitable for 2 TR capacity.
Supply and fixing in repairs thermostat of approved make and suitable size & model for thermostatNo 2059 with knob for window type AC complete all as specified and directed. Make: INDO FOSS/ DENFOSS.
All as per Sr item No 22 above but Auto 'D' thermostat No 1027 with knob for refrigerator.
All as per item No 22 above but thermostat No 2064 with knob for water cooler.
Supply and fixing in repairs potential box type relay/PTC relay of suitable model for window/spilt type AC capacity 1.5 TR complete all as specified and directed. Make: RAMETROL / USHA.
Supply and fixing in repairs OLP - 1622 relay for window type AC complete all as specified and directed. Make: USHA or Equivalent as approved by GE.
Supply and fixing in repairs starting capacitor 60 MFD for water cooler complete all as specified and directed. Make: ASIAN / KELTRON.
All as per item No 27 above but 80 MFD for water cooler.
All as per item No 27 above but 100 MFD for window AC / split AC 1.5 TR.
All as per item No 27 above but 120 MFD for window AC / split AC 2TR.
Supply and fixing in repairs running capacitors of 10 MFD for water cooler complete all as specified and directed. Make: ASIAN / KELTRON.
All as per Sr item No 31 above but 15 MFD for water cooler.
All as per item No 31 above but 36 MFD, for window/split AC 1.5 TR.
All as per item No 31 above but 45 MFD for window/split AC 2 TR.
All as per item No 31 above but 25 MFD.
S & F in repairs blower motor double shaft, single/double speed, single phase, AC, 230V of 1/4 HP (as per sample) complete all as specified and directed. Make: AUE or Equivalent as approved by GE.
All as per Sr item No 37 above but 1/5 HP for Indoor Unit.
All as per Sr item No 37 above but 1/6 HP for Indoor Unit.
All as per Sr item No 37 above but 1/6 HP for outdoor unit.
All as per Sr item No 37 above but 1/8 HP for outdoor unit.
All as per Sr item No 37 above but 1/5 HP for outdoor unit.
S & F in repairs fan blade (as per sample) for window/spilt type AC of any capacity complete all as specified and directed.
S & F in repair air filter made of nylon wire mesh moulded in plastic suitable for existing old filter's size and shape, for 1.5/2 TR capacity of spilt type AC complete all as specified and directed.
S & F in repair front grill assembly (as per sample) complete suitable for existing model of window AC of any capacity complete all as specified and directed.
S & F in repair blower motor (as per sample) 230 V for indoor unit of spilt type AC of any capacity complete all as specified and directed.
S & F in repair remote control with PC board complete suitable for existing model of split AC any capacity complete all as specified and directed.
S & F in repair fan motor capacitor 4 MFD capacitiescomplete all as specified and directed. Make: ASIAN / KELTRON.
All as per Sr item No 48 above but 6 MFD.
All as per Sr item No 48 above but 10 MFD.
S & F in repairs cooling coil suitable for 165 to 180 Ltrs refrigerator complete all as specified and directed.
S & F in repairs cooling coil suitable for 286 to 310 Ltrs refrigerator complete all as specified and directed.
S & F in repairs magnetic door panel gasket complete suitable for existing model of rerigertor of capacity 165 to 310 complete all as specified and directed.
S & F in repairs condenser fan motor, single shaft 1/35, HP capacity, single phase, 230V AC for water cooler complete all as specified and directed.
S & F in repairs condenser fan motor, single shaft 1/83, HP capacity, single phase, 230V AC for water cooler complete all as specified and directed.
S & F in repairs push cock, 15 mm dia brass chromium plated for water cooler complete all as specified and directed.
S & F in repairs fan blade (As per Sample) for water cooler of any capacity complete all as specified and directed.
S & F in repairs copper tubing of 5/8" flare size, confirming to relevant IS complete all as specified and directed.
All as per Sr item No 58 above but 1/2" flare size.
All as per Sr item No 58 above but 3/8" flare size.
All as per Sr item No 58 above but 1/4" flare size.
S & F in repair sheet metal enclosure with socket plug top & MCB single pole and Neutral enclosure with two pin and earth plug & socket with one single pole MCB 20 Amps complete all as specified and directed. Make : Standard / Havells.
S & F in repair 3 core, 2.5 sqmm, copper conductor PVC insulated flexible cable from main supply point to out door unit point complete all as specified and directed. Make: Finolex / Havells.
S & F in repair 15mm bore PTMT float valve for water cooler of any capacity complete all as specified and directed. Make: PRAYAG / POLYTUF.
S & F in repair PVC flexible pipe of suitable size complete for water cooler of any capacity complete all as specified and directed.
Supply and Fix in repairs MCCB 415V, three pole fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed. Make: STANDARD / L&T / HAVELLS.
S & F in repair bi-metal overload relay, directed mounting type suitable for ML series contactor of range 13-21 Amps/ 20-32 Amps complete all as specified and directed.
Supply only compressor oil N-68, Sheetal in sealed pack and filling where directed.
Supply ony Refrigerant gas R-22 in manufacturer sealed cylinder and filling where directed.
Supply only Refrigerant gas R-404 in manufacturer sealed cylinder and filling where directed.
Supply only Refrigerant gas R-32 in manufacturer sealed cylinder and filling where directed.
Supply only Refrigerant gas R-134 in manufacturer sealed cylinder and filling where directed. Note:- Sr item No 69 to 72 :- (i) Empty cylinder will be return to contractor on completion of work (ii) Net weight of refrigerant gas shall be measured and paid under these items.
M&L for cleaning for swimming pool complete which include cleaning of floor/ wall surface area by brush or suction sweeper for non development of algae etc by adding approved chemicals, suction sweep to be carried out by skilled labourers once in a week by using chemical items such as Alum ferric, Bleaching Powder, TCC 90, Copper Sulphate, Soda ash complete all as specified and directed . Note:- Rate quoted shall be deemed to includes for:- (i) On every Thursday total labour, minimum 04 Nos {pipe fitter (skilled)-1 No, labour (unskilled)- 2 Nos, and supervisor} should be available with necessary tools for cleaning of swimming pool such as suction sweeper,rope complete all as specified and directed. (ii) Water testing report before cleaning and after cleaning shall be submitted by the contractor on every maintenance day. (iii) Alum ferric, bleaching powder, TCC - 90, Copper Sulphate, Soda ash shall be measured and paid seperately under relavant items of schedule as supply only. (iv) Contractor should have minimum of 5 years of experience for the maintenance of swimming pool and should have produce the last 3 year attented work performance relevant documents as directed by Engr-in-Charge. (v) The contractor have to deployed a person with the testing kit for water to mix desired qty of chemical on daily basis. Note:- Rate quoted by the contractor includes the wages of person for maintaing quality of water of swimming pool.
Supply and mixing Alum Crystal @ 20 kg per week required for disinfection/ treatment of water.
Supply and mixing bleaching powder @ 30 kg per week required for disinfection/ treatment of water.
Supply and mixing TCC 90 @15 kg per week required for disinfection/ treatment of water.
Supply and mixing Copper sulphate @1.25 kg per week required for disinfection/ treatment of water.
Supply and mixing Soda ash @15 kg per week required for disinfection/ treatment of water.
Supply and mixing Calcium based high strength chlorine granuals @ 30 Kg per week to maintain Chlorine 1 ppm.
Routine maintence/servicing of water supply system and connected equipments installed for filteration system (such as monoblock motor pump sets 2 Nos of capacity 20 HP, water lines piping of various sizes,valve, control panel etc;) of swimming pool . The routine maintenence/servicing includes periodical cleaning and greasing of pump set,cleaning of nozzles of filteration plant, attending and rectifications of leakages occurred on water pipe lines/valves etc in any position complete all as specified and directed by Engineer-in-Charge. Note : S&F in replacement of major spare parts shall be measured and paid separately under relevant items of this Schedule. Minor parts like nut, bolts, washer, joint packing etc are deemed to be included in the unit rate quoted.
S & F in repairs CI impeller required for pump 20 HP capacity complete all as specified and directed.
S & F in repairs ball bearing suitable for motor 20 HP capacity 6307 SKF complete all as specified and directed.
S & F in repairs gland packing of 10mm size required for pump and motor complete all as specified and directed.
M & L for grease of high grade required for pump and motor complete all as specified and directed.
S & F in repairs nut bolt of 12 to 25 mm dia of 40 to 80 mm length required for pump motor and flanged joints complete all as specified and directed.
S & F fibre board gasket 3 mm thick any dia (25mm to 30mm) required for pump, motor and flanged joints complete all as specified and directed.
S & F in repairs MS ERW pipe 'C' class 150mm bore confirming to IS 1239 including making flange of 6 hole of dia 12 to 25 mm complete all as specified and directed.
S & F in repairs MS ERW pipe 'C' class 100 mm bore confirming to IS 1239 including making flange of 6 hole of dia 12 to 25 mm complete all as specified and directed.
S & F in repairs cast iron butterfly valve 150 mm bore, ISI mark PN 1.6 complete all as specified and directed.
S & F in repairs cast iron butterfly valve 100 mm bore ISI mark PN 1.6 complete all as specified and directed.
S & F in repairs 3 pole power contact MNX 40 required for starter of 20 HP motor complete all as specified and directed.
S & F in repairs push button red/green required for motor starter complete all as specified and directed.
S & F in repairs indicator lamp red, yellow, green required for pump motor panel complete all as specified and directed.
S & F in repairs MCB, 63 Amp (isolator), TPN, 415 Volts required for pump motor complete all as specified and directed.
Supply, laying, jointing, testing and commissioning 1100 volts grade, heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3 core 4 sqmm nominal cross sectional in service connection complete all as specified and directed.
S & F in repairs MCCB 3 pole 415 V fixed type 100 Amp with breaking capacity 16 KA complete all as specified and directed.
S & F in repairs cable lugs of suitable size complete all as specified and directed.
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Testing of drinking water including collecting from under ground sumps/over head tanks etc in the area under GE(W) Colaba and submission of detailed test reqport to the office of AGE E/M (West) Colaba including following works complete all as specified and directed. (a) Collection of water from different sources of water ie Sump/OHT in sterilized bottle and testing in Govt Approved laboratory. (b) Carrying out minimum essential testing of drinking water as per IS 10500-2012 mandatory for "colour, odour, taste, PH value, turbidity, TDS, total hardness, iron, chloride, fluride and residual free chlorine aluminium, calcium, copper, magnesium, Nitrate, Sulphate, Alkalinity and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submit the report to office of AGE E/M (West) Colaba with specific recommendation regarding suitability of water for drinking purpose. Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized battle as required. (ii) Transportation charges for collection of samples of water from source (sump / bore well / shallow wells/ OHT).
Unity Enterprises
shubham construction
Bidder Name
Unity Enterprises
Shree Ayyappa Engineering
shubham construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .