| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-Finance DHARAM KHOR BABU BHATNI BHATARPUR RANI DEORIA U P 274705 | DEORIA | DEORIA | UTTAR PRADESH | 274705 | ₹2.9 L | L1 | Accepted-Finance Quoted rate is lowest |
| 2 | L2₹3.1 LRejected-Finance SINGH MAHKAR VILLAGE ANTWARA TEHSIL KHATAULI KHATAULI KHATAULI MUZAFFARNAGAR UTTAR PRADESH 251201 | MUZAFFARNAGAR | UTTAR PRADESH | 251201 | ₹3.1 L | L2 | Rejected-Finance Quoted rate is on higher side |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technical Evaluation is not ok |
| Sl No | Description | Qty | Unit | R.T.K POWER ENGINEERS L1 | VGS ELECTRIC POWER L2 |
|---|---|---|---|---|---|
| 1.00Providing and fixing of 3-phase, 415 volt, 50 Hz, 0.5 Hp, swipe size 2/18'', 800/900 RPM, F type insulation, transformer cooling fan heavy duty Marathon make with guard mash for 132/33 kV 40 MVA BBL make T/F-I installed at 132/33 kV S/S Bansi. | |||||
| 1.10 | 40 MVA Transformer-I BBL Make | 4 | Nos. | 9,000 ₹36,000 Lowest | 12,000 ₹48,000 |
| 1.20 | 40 MVA Transformer-II AREVA Make | 4 | Nos. | 9,000 ₹36,000 Lowest | 12,000 ₹48,000 |
| 2.00Fabrication of cooling fan structure of MS chanel 15x50x50 mm and MS angle 75x75 mm suitable for mounting of said Marathon make T/F cooling fan in section of rediators cooling banks including measuring, cutting , drilling, electric welding of MS chanel/angle and also carry out 2 point earting of cooling bank strcture by 50/6 mm earting strip. The scope of work also includes fixing, mounting of frame and cooling fan on the fabricated structure. wiring of fans and other associated works to complete the job satisfactorily after checkin the performance of the fans after connecting proper supply. All skilled labour, tools, special T&P, electric welding machine and materials shall be provided by the contractor at his own cost. Only electric supply for welding pupose will be provided by the department. | |||||
| 2.10 | 40 MVA Transformer-I BBL Make | 4 | Job | 9,000 ₹36,000 | 6,000 ₹24,000 Lowest |
| 2.20 | 40 MVA Transformer-II AREVA Make | 4 | Job | 9,000 ₹36,000 | 6,000 ₹24,000 Lowest |
| 3.00Providing and fixing of contactor, relay and its wiring circuit for controlling of transformer cooling fan on existing marshalling box. Design cooling fan control circuit for auto manual operation. The following items are to be fixed in the existing marshalling box i.e. 3-phase, 415 V, 20 Amp AC contactor and block unit with OLR, Siemens or C&S or any other equivalent make,10 Amp Kit-Kat HRC fuse unit with 20 Amp AC 3 way auto manual selector switch etc of standard make in the existing marshalling box. The wiring should be 2.5 mm PVC copper wire of good quality and color coding, lugs and ferrules etc. All skilled labour, tools, special T&P, electric welding machine & material shall be provided by the contractor at his own cost complete in all respect for operation of cooling fan on auto/manual mode both. | |||||
| 3.10 | 40 MVA Transformer-I BBL Make | 10 | Job | 6,500 ₹65,000 Lowest | 8,000 ₹80,000 |
| 3.20 | 40 MVA Transformer-II AREVA Make | 10 | Job | 6,500 ₹65,000 Lowest | 8,000 ₹80,000 |
| 4.00Providing and fixing of single phase preventor in both groups of fan of Minilac/L&T make including cost of all required material. Special T&P and labour etc. arranged by contractor for completion of satisfactory work. | |||||
Tender Value
₹4.2 L
EMD Value
₹4,200
Closing Date
20 May 2026, 1:00 pmClosed
Superintending Engineer
Electricity Transmission Circle U.P. Power Transmission Corporation Limited, 220 KV Sub-Station, Gidahi Basti
Providing, Fixing and Operation of Cooling fan on Auto Mode on 40MVA T/F-I (BBL Make) and T/F-II (AREVA Make) installed at 132/33 Sub-Station Bansi under ETD-II, Basti H.Q at Siddharthnagar
2026_UPTCL_1147418_1
Short Term E-Tender No-09/ETC(B)/2026-27
Open Tender
Electrical Works
Lump-sum
60 days
132/33 Sub-Station Bansi
As Per Tender
2 documents required · 2 mandatory
₹590
UPSEB ELECTRICITY TRANSMISSION DIVN
₹4,200
22 Jul 2026
12 May 2026
21 May 2026
12 May 2026
20 May 2026
12 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing and fixing of 3-phase, 415 volt, 50 Hz, 0.5 Hp, swipe size 2/18'', 800/900 RPM, F type insulation, transformer cooling fan heavy duty Marathon make with guard mash for 132/33 kV 40 MVA BBL make T/F-I installed at 132/33 kV S/S Bansi. | |||||
| 1.1 | 40 MVA Transformer-I BBL Make | 4 | Nos. | - | - |
| 1.2 | 40 MVA Transformer-II AREVA Make | 4 | Nos. | - | - |
| 2Fabrication of cooling fan structure of MS chanel 15x50x50 mm and MS angle 75x75 mm suitable for mounting of said Marathon make T/F cooling fan in section of rediators cooling banks including measuring, cutting , drilling, electric welding of MS chanel/angle and also carry out 2 point earting of cooling bank strcture by 50/6 mm earting strip. The scope of work also includes fixing, mounting of frame and cooling fan on the fabricated structure. wiring of fans and other associated works to complete the job satisfactorily after checkin the performance of the fans after connecting proper supply. All skilled labour, tools, special T&P, electric welding machine and materials shall be provided by the contractor at his own cost. Only electric supply for welding pupose will be provided by the department. | |||||
| 2.1 | 40 MVA Transformer-I BBL Make | 4 | Job | - | - |
| 2.2 | 40 MVA Transformer-II AREVA Make | 4 | Job | - | - |
| 3Providing and fixing of contactor, relay and its wiring circuit for controlling of transformer cooling fan on existing marshalling box. Design cooling fan control circuit for auto manual operation. The following items are to be fixed in the existing marshalling box i.e. 3-phase, 415 V, 20 Amp AC contactor and block unit with OLR, Siemens or C&S or any other equivalent make,10 Amp Kit-Kat HRC fuse unit with 20 Amp AC 3 way auto manual selector switch etc of standard make in the existing marshalling box. The wiring should be 2.5 mm PVC copper wire of good quality and color coding, lugs and ferrules etc. All skilled labour, tools, special T&P, electric welding machine & material shall be provided by the contractor at his own cost complete in all respect for operation of cooling fan on auto/manual mode both. | |||||
| 3.1 | 40 MVA Transformer-I BBL Make | 10 | Job | - | - |
| 3.2 | 40 MVA Transformer-II AREVA Make | 10 | Job | - | - |
| 4Providing and fixing of single phase preventor in both groups of fan of Minilac/L&T make including cost of all required material. Special T&P and labour etc. arranged by contractor for completion of satisfactory work. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
TECHNICAL09.pdf
Tender Documents • 0.98 MB
BOQ_2146603.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].