Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹49.6 L+₹1.6 L (3.34%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹50.8 L+₹2.8 L (5.76%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹53.4 L+₹5.4 L (11.2%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Aug 2020, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR/MAINT AND OVER OILING OF DG SETS OF CAPACITY 7.5 TO 320 KVA AND CONNECTED WORKS AT GMS
2020_MES_364685_1
8000/29/2020-21/0928/E8
Open Tender
Civil Works
Item Rate
270 days
GARRISON ENGINEER I GOS
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹40,000
Yes
22 Oct 2020
28 Jul 2020
22 Aug 2020
28 Jul 2020
20 Aug 2020
13 Aug 2020
Amount
Dismantling fencing wire mesh, any type complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) embedded in natural ground etc any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Excavation in soft / loose soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
M&L for RCC type B-1, 1:2:4 using 20 mm graded stone aggregate in precast posts, fencing posts, straining or terminal posts, struts etc for fencing average sectional area exc 100 Sq cm but not exc 250 Sq cm with or without chamfered angles and flat, splayed, rounded or mitred tops and fixed complete all as specified and directed.
Mild Steel Fe-410-W Gde E-250 or Fe-290 Gde E-165 round bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F PVC coated chain link fencing 100 x 100 mm mesh size made out of GI wire from 2.5 to 2.85 mm dia having minimum 1mm thick PVC coating over it including inner woven wire.Weight of wire mess not exc 4kg/sqm complete all as specified and directed.
S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm but not exc15 cm long and 11 to 15 mm dia of shank complete all as specified and directed.
S&F Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of posts, straining bolts,standard bolt, including securing or tying at crossing with and including provision of galvanized mild steel wire staples or steel pins, etc complete all as specified and directed (Each line of wire to be measured for the purpose of payment).
M&L for preparation of new or previously untreated surfaces of steel of any description, not exc 10cm in width or girth when unconnected with other painting and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Excavation in any type of soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugation side lap fixed with L-type or J- type or cranked hook bolt in roof, wall etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removal of rubbish from site complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
Mild steel bars TMT 10mm and over, cut to length bend to shape required incl cranking bending and binding with mild steel wire (annealed) not less than 0.9 mm dia.
Precast RCC 1:2:4 type B1 using 20mm graded stone agg in cover slabs set in cement mortar 1:6 including all necessary form work (Note : Reinforcement shall be measured and paid separately).
M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for walling of random rubble uncoursed stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
Description all as per above item but except stone
Hammer dressing to RR masonry wall (granite basalt/trap stone) uncoursed with maximum depresion of 40 mm from straight edge held against the surface complete (for area to be pointed)
M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L Hardcore of broken stoneor boulder of guage n.exc 63 mm, deposited, spreed and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L Cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggreates 100 mm thick as in flooring finished even and fair complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates as in hard standing 100 mm thick laid in panels and finished even and smooth without using extra cement and spike rolling to surfaces or making impression of expanded metal whilst the concrete surface is green complete all as specified and directed.
M & L for Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes.
M&L chequered cement concrete tiles 20 cm X 20 cm X 25 mm thick, set , jointed and pointed in neat cement surry in floors with pigments complete all as specified and directed.
50 mm thick Sand cushning below interlocking paver tile.
Machine pressed precast concrete interlocking paver block any shape and size fixing with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 100 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
S&F in replacement oil filter suitable for 7.5 to 30 KVA DG set capacity as per existing size complete all as specified and directed as per existing . Make : Boss or eqvt
All as per item No 48 above but 40 to 82.5 KVA capacity
All as per item No 48above but 200 to 320 KVA capacity
S&F in replacement disel filter suitable for 7.5 to 30 KVA DG set capacity as per existing size complete all as specified and directed as per existing . Make : Boss or eqvt
All as per item No 51 above but 40 to 82.5 KVA capacity
All as per item No 51 above but 200 to 320 KVA capacity
S&F in replacement fan belt suitable for DG set of 7.5 to 82.5 KVA capacity complete all as specified and directed ,
All as per item No 54 above but 200 to 320 KVA capacity
M&L for draining out oil from engine of DG set of any capacity, cleaning the oil chamber, supply and filling of lubricant in replacement GENSET OIL multi-grade 20W40 complete all as specified and directed, Make- Castrol/Gulf
S&F in replacement of coolant suitable for DG sets complete all as specified and directed, Make - GULF / TVS / CASTROL
Checking and inspecting of the DG set Metering AMF panel board system throughly, including removing of the unserviceable damaged control coiling,rewiring of the same with suitable size and carried out of necessary painting matching with existing colour including tightining for all the loose contacts, reconnecting back and testing complete all as specified and directed by Engineer-in-charge.
Maint, repair & overhauling of diesel engine Gen. sets capacity 320 KVA to 200 KVA of any make / any type, horizontal type by dismantling complete engine assembly from alternator, transporting for repairs workshop, opening for inspection for carrying out repairs, replacement of worn out and defective components,cleaning internally and externally, including transportation by using crane complete all as specified and directed Note :- (i) Spare parts and Job works, shall be measured and paid for separately under relevant items of this schedule. (ii) All other works related with overhauling is deemed to be included in unit rate of the item.
All as per item No 59 above but 100 KVA to 62.5 KVA
All as per item No 59 above but 50 KVA to 30 KVA
All as per item No 59 above but 30 KVA to 7.5 KVA
M & L for Calibration of fuel pump including Injectors capacity 320 KVA to 200 KVA
All as per item No 63 above but 100 KVA to 62.5 KVA
All as per item No 63 above but 50 KVA to 30 KVA
All as per item No 63 above but 30 KVA to 7.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Cylinder liner capacity 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Cylinder liner capacity 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Cylinder liner capacity 62.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Cylinder liner capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Ring set for piston assembly for capacity 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Ring set for piston assembly for capacity 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Ring set for piston assembly for capacity 62.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Ring set for piston assembly for capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket cylinder head capacity for 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket cylinder head capacity for 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket cylinder head capacity for 62.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket cylinder head capacity for 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Inlet valve capacity 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Inlet valve capacity 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Inlet valve capacity 65.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Inlet valve capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) outlet valve capacity 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) outlet valve capacity 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) outlet valve capacity 62.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) outlet valve capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket oil chamber capacity 7.5 KVA to 25 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket oil chamber capacity 30 KVA to 50 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket oil chamber capacity 62.5 KVA to 100 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Gasket oil chamber capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) CR bush capacity 7.5 KVA to 82.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) CR bush capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) CR bearing capacity 7.5 KVA to 82.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) CR bearing capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Packing kit capacity 7.5 KVA to 82.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Packing kit capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Push rod kit assembly including Rod capacity 7.5 KVA to 82.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Push rod kit assembly including Rod capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Pump nozzle kit capacity 7.5 KVA to 82.5 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Pump nozzle kit capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Water pump assembly capacity 200 KVA to 320 KVA
Supply only in repair as spare part ( Fixing covered under respective item of overhauling ) Water pump assembly capacity 62.5 KVA to 100 KVA
Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position for the capacity of DG set 7.5 KVA to 30 KVA
All as per item No 103 above but 40 to 82.5 KVA capacity
All as per item No 103 above but 200 to 320 KVA capacity
Replacement of existing unsv air cleaning element inner with necessary 'O' rings for the DG sets ofcapacity 7.5 KVA to 82.5 KVA as that of existing make and model .
Replacement of existing unsv air cleaning element inner with necessary 'O' rings for the DG sets ofcapacity 200 KVA to 320 KVA as that of existing make and model .
Dismantling radiator of 7.5 to 30 KVA DG Set complete from engine mounting frame, opening and clearing with use of acid, to clear the choked tubes, over hauling of the same, arresting the leakages with soldering, replacing the gasket including replacement of water pump seal, lub oil filter, corrossion resistor filter, reefixing back the radiator in the original position, reconnecting back and testing complete all as specified and directed by Engineer-in-charge
All as per item No 108 above but 40 to 82.5 KVA capacity
All as per item No 108 above but 200 to 320 KVA capacity
Takingdown unserviceable self-starter 12 volts from engine,dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified and directed by Engineer-in-charge
All as per serl item No 111 above but 24 volts
Dismantling and taking out unserviceable dynamo/alternator of charging unit of battery 12 volts including opening and seviceing of field coil of stator,rotor unit, replace wornout carbon brush,bushes, Bentex pinion complete all as specified and directed
All as per serl item No 113 above but 24 volts
M & L for Re-commissioning of Disel engine Genarator sets capacity 7.5 to 82.5 KVA after repairing at workshop including testing and transporataion from Workshop to E/M Installed site by using crane all as specified and directed .
All as per serl item No.115 above but capacity 200 KVA to 320 KVA
M & L for Dismantling, Lifting & transportation of Alternator of DG Set capacity 20 KVA to 82.5 KVA and keeping the core inside oven chamber to removing of moisure and increasing of the insulation value of core and drying the core assembly for minimum 3 days at a temp of 120oC including Re-fixing and alighnment all as specified and directed . Note :- (a) Cost for lifting/lowering the core of Alternator by crane is inclusive.(b) Labour for fixing the connection/removal of connection inside the heating chamber is inclusive. (c) Power consumption for heating core for improving insulation value is inclusive. (d) Temperature 120oC to be maintained and inclusive in rate quoted.
All as per item No.117 above but 200 to 320 KVA capacity
M/s Ats Electricals
M/s Bapujee Builders and Traders
M/s MAA BHAIRABI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .