Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 249 LIG PREETAM NAGAR ALLAHABAD UTTAR PRADESH PIN 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
1 Jan 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
MNNIT Allahabad, Prayagraj-211004
Requirement of electrical wiring for new computer systems in Simulation lab (EED) and Requirement of electrical connections and earthing for FESEM instrument in CIR Lab.
2024_MNNIT_841252_1
10/ESWM/2024-25
Limited
Electrical Works
Item Rate
60 days
Academic Campus MNNIT Allahabad
Please refer Tender documents
2 documents required · 2 mandatory
₹0
Exempted
2 Jan 2025
24 Dec 2024
2 Jan 2025
24 Dec 2024
1 Jan 2025
24 Dec 2024
Requirement of electrical wiring for new computer systems in Simulation lab (EED) and Requirement of electrical connections and earthing for FESEM instrument in CIR Lab.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Complete in all respect.Make- Anchor Roma, Havells crabtree,C&S.
Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Complete in all respect.Make- Anchor Roma, Havells crabtree,C&S.
Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for following circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Complete in all respect.Make- KEI,R.R Kable, Kalinga Premium. HPL, Havells, Rallison, V-Marc 2 X10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. Single pole
Supplying and fixing 63 amps rating, FP , 415 volts, miniature circuit breaker (10kA), C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells , Legrand, HPL,C&S,ABB, Schnieder, Simens.CAT-B
Supplying and fixing 40 amps rating, DP , 220 volts, miniature circuit breaker (10kA), C curve, suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells , Legrand, HPL,C&S,ABB, Schnieder, Simens.CAT-B
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. Complete in all respect. (But without MCB/ RCCB/ Isolator). Make- L&T, Havells , Legrand, HPL,C&S,ABB, Schnieder, Simens. 8 way , Double door
Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. Complete in all respect. (But without MCB/ RCCB/ Isolator). Make- L&T, Havells , Legrand, HPL,C&S,ABB, Schnieder, Simens. 6 way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections,testing and commissioning etc. as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S. Single pole and Neutral
Supplying & fixing DP Sheet steel enclouser on surface/recess along with 32 amps to 40 amp 240 volt"C" curve DP MCB complete with all connection, testing commissioning etc as required.complete in all respect.Make- L&T, Havells, Legrand, HPL, C&S.
Supply and burring of Safe Earthing Electrode T-39 Cu Copper Coated, Length up to 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 Copper Strip will be extra). The specification of grounding terminal is 100 Ohm or less and Neutral to earth voltage should be less than 2V AC.
Supply and fixing of two number 8 SWG copper wire in 15 dia G.I. pipe for earthing, laid in ground or in wall duly concealed including the post of cement, sand, labour, T&P other material required for proper completion of the work with 2 Nos.8 SWG copper wire. complete in all respect.
M/S RAJANI SINGH (BID ID -3147578)
B. J. V. ENGINEERING WORKS (BID ID -3147610)
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .