| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC HOUSE NO 129 BASISTHA ROAD BASISTHA CHARIALI PO BASISTHA GUWAHATI 781029 ASSAM | KAMRUP METRO | ASSAM | 781029 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.1 L+₹24,504.80 (1.55%)Rejected-Finance C O DEEP BROTHERS BASISTHA NATUN BAZAR GUWAHATI 29 ASSAM | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
2 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT OF SEWAGE LINES, MANHOLES, SEPTIC TANKS AND SOAK WELLS AT BASISTHA UNDER GE GUWAHATI
2022_MES_528943_1
GE/GUW/10/8210 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GUWAHATI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE GUWAHATI
₹34,000
Yes
18 Aug 2022
6 Jun 2022
4 Jul 2022
6 Jun 2022
2 Jul 2022
20 Jun 2022
6 Jun 2022 - 13 Jun 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including spreading. Levelling, watering and well ramming in layers not exc. 25 cm in ay type of soil complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc. 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete after demolition of existing old conceret work complete all as specified and directed.
M&L for PCC (1: 3:6) type C-2 as in surface channels and drains after demoilition of existing complete all as specified and directed.
M&L for finishing cement concrete surface even and smooth using extra cement complete all as specified and directed.
M&L for concrete bed in P.C.C. 1:3:6 type C2 (using 40mm graded stone aggregated )as in concrete bed to drain pipe 150mm dia pipes including packing under and haunching against the sides of the pipes after laying & testing complete all as specified and directed..
M & L for 150mm salt glazed stone ware drain pipes grade 'A' laid in trenches & jointed complete all as specified and directed..
Cleaning of blockage of floor/nahani trap by using hand pump with rubber bucket or by cleaning rod till clear flow of water is observed complete all as specified and as directed.
Removing of blockage of Indian/European type water closet by using hand pump with rubber bucket or by opening the inspection eye by using cleaning rod etc till clear flow of water is observed and finally cleaning the water closet by flush of water complete all as directed.
Taking out of sludge water and semi solid materials/sludge including other foreign materials from the manholes/septic tanks not exc. 1.5meter deep and getting out, removing & disposing off the sludges by excavating required size pit, covering the pit with earth minimum 30 cm deep, spreading bleaching powder @ 1 Kg per pit complete all as directed. Notes:- (i) Unit rate shall be deemed to be inclusive of taking down of manhole cover & re-fixing the same in position after cleaning complete. (ii) Unit rate shall also be inclusive of removing sludge from manholes and deposited in excavated pit of size as directed by Engr-in-Charge, spreading lime poser over the deposited sludge in the pit & covered with earth. Measurement for sludge shall be taken from the excavated pit after allowing initial percolation of sludge water.
Taking out of sludge water and semi solid materials/sludge including other foreign materials from the manholes/septic tanks exc 1.5 meter and not exc. 3 meter deep and getting out, removing & disposing off the sludges by excavating required size pit, covering the pit with earth minimum 30 cm deep, spreading bleaching powder @ 1 Kg per pit complete all as directed. Notes:- (i) Unit rate shall be deemed to be inclusive of taking down of manhole cover & re-fixing the same in position after cleaning complete. (ii) Unit rate shall also be inclusive of removing sludge from manholes and deposited in excavated pit of size as directed by Engr-in-Charge, spreading lime poser over the deposited sludge in the pit & covered with earth. Measurement for sludge shall be taken from the excavated pit after allowing initial percolation of sludge water.
Taking out of sludge water and semi solid materials/sludge including other foreign materials from sump at sewage pumping station depth n.exc 15m with required mechanical pump of required capacity or by manually by using rope, bucket, ladder and scaffolding etc. and getting out, removing and disposing off the sludge in to a pit of required size made by excavating , and covering the pit with earth not less than 30 cm thick, spreading bleaching powder @ 1 Kg per pit over complete all as direted. Notes:- (i) Unit rate shall be deemed to be inclusive of taking down of cover & re-fixing the same in position after cleaning complete. (ii) Unit rate shall also be inclusive of removing sludge from sump and deposited in excavated pit of size as directed by Engr-in-Charge, spreading lime poser over the deposited sludge in the pit & covered with earth. Measurement for sludge shall be taken from the excavated pit after allowing initial percolation of sludge water.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 100mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 150mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/chock remover and making the continuous flow between two manholes for 200mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured.
Demolition of brick work or stone boulder masonary built in cement morter complete all as directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6.00 m mean radious built in CM 1:6 complete as specified and directed.
M&L 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement complete all as specified and as directed. Note:- WPC will be measured and paid seperately at Supply Only rate
Supply only Liquid water proofing compound all as specified and directed.
M&L preparing new plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L plain cement concrete (1:2:4) type B0) (using 12.5 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all directed.
Materials and labour precast reinforced cement concrete 1:2:4 (using 20mm graded stone aggregate) type B1 as in cover slabs and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed.
Materials and labour for TMT bars, 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified.
Taking down eaves gutter and rain water pipes ( any size or pattern) including all fittings, heads,shoes, bends, swan necks etc complete all as directed.( Measured overall as fixed along the centre line over fittings and accessories).
S&F in repair UPVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, fixed with wall complete all as specified and as directed.
S&F in repair UPVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and as directed.
S&F in repair UPVC (SWR) pipes 75mm single socketed, in any length with rubber ring joints, fixed with wall complete all as specified and as directed.
S&F in repair UPVC (SWR) pipes 75mm single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and as directed.
S & F 110 mm bore UPVC (SWR) bends any radius complete all as specified and directed.
S & F 75 mm bore UPVC (SWR) bends any radius complete all as specified and directed.
S & F 110mm bore UPVC ( SWR) junction, single (Single T) equal or unequal complete all as specified and directed.
S & F 75mm bore UPVC ( SWR) junction, double (double T) equal or unequal complete all as specified and directed.
S&F 110mm bore UPVC (SWR) branch piece, single ( single -Y) equal or unequal complete all as specified & directed.
S&F 75mm bore UPVC (SWR) branch piece, single ( single -Y) equal or unequal complete all as specified & directed.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof sutable for 110 mm dia including drilling holes & fixed to wall with nails etc complete. all as specified and directed.
S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof sutable for 75 mm dia including drilling holes & fixed to wall with nails etc complete. all as specified and directed.
S & F in repairs UPVC(SWR) Nahani trap 75 mm dia with grating including jointing with solvent cement all as specified and directed.
S & F in repairs PVC(SWR) gully trap 125x110 mm including jointing with solvent cement all as specified and directed.
S&F PVC (SWR) vent cowl of 110mm dia all as specified and directed.
S&F in repair PVC (SWR) 'P’ trap 125/110mm bore all as specified and directed.
S&F in repair Vitreous China, pedestal pattern white (excluding flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), 'P' or 'S' trap, providing joints between flush pipe and socket of WC pan, cones, India rubber (nozzles of WC pan) including providing 150mm thick cement conrete bedding (type E2, 1:5:10, 40mm graded aggregate) complete all as specified and directed.
S&F in repair, Grating doom 100mm dia of PTMT (Minimum weight 25gms) ,complete all as specified and directed.
S&F in repair, Grating doom 125mm dia of PTMT (Minimum weight 40gms) ,complete all as specified and directed.
S&F in repair, Grating doom 150mm dia of PTMT (Minimum weight 100gms) ,complete all as specified and directed.
M &L Non skid ceramic coloured tiles area of each tiles (Square / rectangular) exc 0.11 sqm but n. exc 0.18 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick cement screed bed in cement mortar (1:6) complete, all as specified and as directed.
M&L PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as filling in sunken floor slab including demoliation of existing portion and removing debries off the site complete all as specified and as directed.
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection/pavings laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight , including demoliation of existing plinth protection/pavings and removing debries off the site complete all as specified and as directed.
M&L water proofing treatment to sunken slab with the following courses of treatment and the Work shall be executed as per manufacturers instruction complete all specified and as directed. (i) Cleaning of surfaces by picking, sweeping clean and washing down with water to remove dust, etc (ii) Applying a layer of cement slurry @ 0.488Kg/Sqm mixed with acrylic based polymer modified cementotous compound @0.253 Kg/Sqm. This layer shall be allowed to cure for 4 Hours (iii) Second layer of cement slurry @ 0.242 Kg/Sqm mixed with Acrylic based polymer modified cementotous compound @0.126 Kg/Sqm. This layer shall be allowed to cure for 48 Hours (iii) 200 micron thick polythene film pasted with help of adhesive over the treated surfaces
DEEP CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .