Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.0 LAccepted-AOC GOGAMUKH CHAULDUHWA GOGAMUKH ASSAM | GOGAMUKH | DHEMAJI | ASSAM | ₹75.0 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹75.0 LRejected-AOC 10 B O C GATE BONGAIGAON BONGAIGAON BONGAIGAON ASSAM 783380 UDYAM AS 04 0001543 | BONGAIGAON | ASSAM | 783380 | ₹75.0 L | L2 | Rejected-AOC Not Awarded |
| 3 | L3₹75.9 LRejected-AOC GOGAMUKH NAGAON CITY TOWN GOGAMUKH P O GOGAMUKH P S GOGAMUKH PIN 787034 DISTRICT DHEMAJI ASSAM | DHEMAJI | ASSAM | 787034 | ₹75.9 L | L3 | Rejected-AOC Not Awarded |
| 4 | Rejected-Technical 2 PUB SURUJ NAGAR KAHILIPARA DISPUR GUWAHATI ASSAM 781019 | KAMRUP METRO | ASSAM | 781019 | - | - | Rejected-Technical As per Comparative Statement (Technical Bid) is Non Responsive |
| 5 | Rejected-Technical DAKHINGAON DISPUR P O DISPUR P S DISPUR DIST KAMRUP M ASSAM | - | - | Rejected-Technical As per Comparative Statement (Technical Bid) is Non Responsive |
| Sl No | Description | Qty | Unit | M/S P.D. ENTERPRISE L2 | Raju Khanikar L3 | RAHUL PATIR L1 |
|---|---|---|---|---|---|---|
| 1.00Civil Works | ||||||
| 2.00 | A. Construction of Classroom Building 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 91.79 | Cum | 312.67 ₹28,699.98 | 300 ₹27,537 | 300 ₹27,537 |
| 3.00 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 313.03 | Cum | 2,355.71 ₹7.4 L | 2,700 ₹8.5 L | 2,400 ₹7.5 L |
| 4.00 | 2.28 Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2.28.1 All kinds of soil | 164.19 | Sqm | 30.68 ₹5,037.41 | 30 ₹4,925.76 | 30 ₹4,925.76 |
| 5.00 | Analysis-1 : Providing Brick on flat soling in foundation and under floor with bricks of class designation 7.5 including filling the joints with fine sand, with common burnt clay non modular bricks and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. | 96.35 | Sqm | 664.9 ₹64,061.79 | 600 ₹57,808.80 | 600 ₹57,808.80 |
| 6.00 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) | 25.59 | Cum | 6,264.01 ₹1.6 L | 5,700 ₹1.5 L | 5,700 ₹1.5 L |
| 7.00 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) | 318.89 | Sqm | 1,136.98 ₹3.6 L | 1,500 ₹4.8 L | 1,500 ₹4.8 L |
| 8.00 | 11.2 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. | 299.81 | Sqm | 799.3 ₹2.4 L | 1,000 ₹3.0 L | 1,000 ₹3.0 L |
| 9.00 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 7.26 | Cum | 8,028.01 ₹58,259.27 | 7,300 ₹52,976.10 | 7,300 ₹52,976.10 |
| 10.00 | 11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. | 231.83 | Sqm | 932.93 ₹2.2 L | 1,000 ₹2.3 L | 1,000 ₹2.3 L |
Tender Value
₹75.0 L
EMD Value
₹1.5 L
Closing Date
8 Apr 2026, 2:00 pmClosed
Managing Director
Office of the Managing Director, APTDC Ltd., Ganeshguri, Ghy, 5
Major Renovation at Naharbari Novodaya ME School, Bordoloni, Dist - Dhemaji under DAJGUA during the year 2025-26.
2026_WPTBC_52120_1
PTDC/Engg/2026-27/538
Open Tender
Civil Works
270 days
Dhemaji
Please refer tender document
3 documents required · 3 mandatory
₹5,000
₹1.5 L
Yes
Managing Director, APTDC Ltd., Ganeshguri, Ghy, 5
20 May 2026
17 Mar 2026
9 Apr 2026
18 Mar 2026
8 Apr 2026
19 Mar 2026
23 Mar 2026
Civil Works
A. Construction of Classroom Building 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2.28 Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 2.28.1 All kinds of soil
Analysis-1 : Providing Brick on flat soling in foundation and under floor with bricks of class designation 7.5 including filling the joints with fine sand, with common burnt clay non modular bricks and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
11.2 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick
13.1 12 mm cement plaster: 13.1.1 1:4 (1 cement : 4 fine sand)
13.5 15 mm cement plaster : 13.5.1 1:4 (1 cement : 4 coarse sand)
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) sqm 1145.95
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.4 Barge board (Upto 300 mm)
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
13.52 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 ainting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
10.14 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1 Profile B 10.14.1.1 Fixing with adjustable lugs with split end tail toeach jamb,
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) 9.5.1Second class teak wood 9.5.1.1 35 mm thick shutters
9.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.63.1 250x10 mm
9.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 9.62.1 300x16 mm
9.66 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 9.66.1 125 mm
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes
10.26 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding kg 181.00
11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 11.20.4 Ordinary cement without any pigment
11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 11.23.2 Raj Nagar plain
11.41A. Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 Size of Tile 600 x 600 mm,
B. Repairing & Renovation existing Toilet Block. 15.24 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead :
15.14 Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : 15.14.1 Of sectional area 40 square centimetres and above
15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below
15.13 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 15.13.1 Of area 3 sq. metres and below
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1.2 30 mm thick shutters
15.28 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 15.28.1 G.S. Sheet
15.56 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
15.58 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
14.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand)
13.37 White washing with lime to give an even shade : 13.37.1 New work (three or more coats)
13.41 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
13.44 Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
12.26 Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.2 6 mm thick Cement bonded wood particle board as per IS:14276
11.2 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.2 Kiln seasoned and chemically treated hollock wood
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.2 30 mm thick shutters
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2A 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 20%
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.3A 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)
C. Internal Electrical Work. 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.3.1 Group-A
1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.3.2 Group-B
1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.3.3 Group-C
1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/rcessed steel conduit as required. 1.7.1. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/rcessed steel conduit as required. 1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.2 2 way 5/6 A switch
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.3 15/16 A Switch
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin 5/6 A socket outlet
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.5 6 pin 15/16 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.3 4 Module(125mmX75mm)
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.4 6 Module(200mmX75mm)
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.5 8 Module (125mmX125mm)
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 1.28.3 4 Module
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 1.28.4 6 Module
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 1.28.5 8 Module
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 1.28.6 12 Module
2.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 2.1.1 32A TP&N
2.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 2.1.2 63A TP&N
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess cpmlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 2.3.1 6 way, Double door
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess cpmlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 2.3.2 8 way, Double door
1.13 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.1 25A
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40A
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. As required.
E&M Supplement Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted icluding earthing etc. as required. 2.4.1 4 way (4 + 12), Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted icluding earthing etc. as required. 2.4.2 6 way (4 + 18), Double door
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.1 40A
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2 63A
2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 2.24.1 For 4 way, Double door TPN MCBDB
2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 2.24.2 For 6 way, Double door TPN MCBDB
2.24 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 2.24.3 For 8 way, Double door TPN MCBDB
4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 4.6.3 225 mm width X 50 mm depth X 1.6 mm thickness
1.42 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
D. Furniture Requirements for Classroom Building: 1. Knock down class room dual desk is specially designed for rugged use. The desk are made of pressed formed MS CRCA section & CRCA tube fitted with pre laminated Particle board top, seat & back with Machine pressed PVC egde banding 2 mm thick glued with industrial adhesive and diffused with board monolithically . Hanger for water bottle and bag. Space for keeping pen, pencil and scale. The overall appearance of the product shall be as per indicative potographs attatched: DESK TOP –18mm Both Side laminate(BSL) PreLam Partical Board 400 mm wide BENCH TOP – 18mm BSL PreLam Partical Board 330 mm wide FRONT SHELF – 18mm BSL PreLam Partical Board 300(Wide)mm. BENCH BACK – 18mm BSL PreLam Partical Board 250(W)mm. Modesty Panel – 18mm BSL PreLam Partical Board 300 (W)mm. Supporting Understrucure- Left Hand and Right Hand FRAME consisting of vertical, horizontal and Cross Member made up of 25 x 1.2 mm outer dia ERW tube confirming to IS Grade 4923 and shall be finised with epoxy polyster powder coated finish with DFT 50-60 Micron confirming IS 13871:1993. The support system of Bench and Shelf shall also made up of made up of 25 x 1.2 mm outer dia ERW tube confirming to IS Grade 4923 and shall be finised with epoxy polyster powder coated DFT 50-60 Micron confirming IS 13871:1993.. Resting support plate made of Table top , provided on the top of vertical members shal be made up of 3mm Thk CRCA sheet Conforming IS code 513. Legs shall be fitted with PVC Leveler. Construction is fully welded with MIG welding and assembled using M6 trilobularscrews(As per DIN 7500)with Zn blue plating. Compact top, seat and back panels are assembled using M6 Countersunk Trilobular screws(as per DIN 7500) with Zn Black Plating (As per IS 1573:1986). 1 (a) Dual Desk :Overall Size 1100 (W) x 930-950( D) x 650 (H) - Desk Depth 390-400 mm. Seat Height 375 mm for Classs 6-8)
2. Supplying Fitting, fixing and commissioning of Water Purifier including all necessary equipments as per direction by the concern authority. (Make Kent/Aqua Gurd) 10 Lt capacity
3. Supply and installation of Office table as per approved design and as directred by Engineer-in-charge Work Top - Work top shall be made 25mm thick Pre-lam MDF board confirming to IS 12406:2003 with post forming on front , back and machine pressed PVC egde banding 2 mm thick glued with industrial adhesive and diffused with board monolithically on other two sides Understructure- C-type leg shall be made of 50X50X1.6mm thick vertical member and 40x40x1.6mm thick M.S. pipe of Horizontal/ Cross member confirming IS-Grade 4923 and shall be finished with epoxy polyster powder coated DFT 50-60 Micron. Legs shall be fitted to the ground with M8 screw leveler with the height adjustment up to 12mm to 15mm.Cross members shall be mounted by end brackets made of 3mm thick CRCA sheet confirming IS 513: 2008 and finished with epoxy polyster powder coated DFT 50-60 Micron confirming IS 13871:1993. Wire management - Electrical wires shall be carried from horizintal/ vertical duct made of 0.7mm CRCA sheet confirming to IS 513:2008. Switch Plate or Cromet depending upon requirement shall also be provided for electrical/LAN connection on table top. Modesty Panel -Modesty Panel of height 450 mm shall be made of 1.5mm thick CRCA sheet confirming to IS 513: 2008 and shall be finised with epoxy polyster powder coated DFT 50-60 Micron. Storage body- Storage top shall also be made of 25mm thick Pre-lam MDF board confirming to IS 12406:2003 with post forming on two sides and machine pressed PVC egde banding 2 mm thick glued with industrial adhesive and diffused with board monolithically on other two sides. The body of storage units shall be made of 0.8mm thick CRCA Sheet and skirting shall be of 1.2mm thick CRCA sheet confirming to IS 513: 2008 finished with epoxy powder coated of DFT 50-60 Micronconfirming IS 13871:1993 3 (a) Table of Size 1650 W x 750 D x 750 H with Side Storage of Size 900W x 450W X 750H and Back Storage 1800 W x 450 D x 750H
4. Supply and installation of 12 Seater Meeting Table of of overall size 3600 x 1350 (Avergae) x 750 mm (Knock down construction). Table Top and Gable End shall be made of 25mm thick Pre-Laminate Partical Board with 2mm thick Machine pressed PVC edge banding glued with industrial adhesive and monolithically diffused. Supporting Understrucure consists of 2 Metal C Legs on either ends of table support frame made of 50 x 50 x 1.6 mm MS ERW tube and One number Wire Carrier leg at middle of 50X50X1.6 mm. 4 numbers Horizontal connector of 40mm X 40mm X 1.6mm thick MS Pipe between supporting vertical legs. All The MS Pipes and Sheet shall be finished with epoxy powdercoated of DFT 50-60 Micron. C typed metal legs shall be kept 150 mm inside from from end of table. WIRE MANAGEMENT - The Vertical (snake) & Horizontal(cable tray) wire carriers are placed below worktop, made up of CRCA with epoxy powder Coating & Fixed to the understructure with specially designed brackets. Provision of placing switch plates/Cromet in the cable tray .
5. Supply & Placing of Glassdoor Storage of Size 916mm(W)x 486mm (D)x1980mm(H). It should have shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA sheet ‘D’ grade high yield strength as per IS:513. The glass door storwel shall have a brass handle and a 2 way locking mechanism with shooting bolt. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base.All metal components would be epoxy polyster powder coated DFT 50-60 Micron confirimg to IS 13871:1993
6. Supply & Placing of Metal Almirah of Size 916mm(W)x486mm(D)x 1980mm(H). It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all otherm components shall have a thickness of 0.9mm. These components shall be made of CRCA sheet ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It shall have 4 no.s full shelves. A4 size box file(85 W x 285 D x 345 H mm) can be stored vertically on three shelves and the clear space above fourth shelf is 240mm. It should also have a M10 Screw type Leveller with Hex plastic base.
7. Supllying & placing in position Executive Chair as per indicative photograph and specification: (i) SEAT/BACK ASSEMBLY: The seat and back should be made up of 1.2 ±0.1cm. thick hot-pressed plywood and upholstered with .fabric upholstery covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area. BACK SIZE 47.5 cm. (W) x 69.5 cm (H) SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D) (ii) HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density = 45±2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression. (iii) ARMRESTS :The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. (iv) CENTER TILT SYNCHRO mechanism: The mechanism should be designed with the following features: • 360° revolving type. • Upright-position locking • Tilt tension adjustment • Seat/back tilting ratio of 1:3. (v).PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 12.0 ±0.3cm. (vi).TELESCOPIC BELLOW ASSEMBLYThe bellow should be 3 piece telescopic type and injection moulded in black Polypropylene. (vii).PEDESTAL ASSEMBLY:The pedestal should be injection moulded in black 33% glass-filled Nylon-66 and fitted with 5 nos. twin wheel castors. The pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors). (viii).TWIN WHEEL CASTORS:The twin wheel castors should be injection moulded in Black Nylon. (Principal /Headmaster Chair)
8. Supply & Installation of Medium Back Chair as perindicative photograph and specification: (i).SEAT/BACK ASSEMBLY: The seat and back should be made up of 1.2 ±0.1cm. thick hot-pressed plywood and upholstered with .fabric upholstery covers and moulded Polyurethane foam. The back foam should be designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area. BACK SIZE 47.5 cm. (W) x58.0 cm (H) SEAT SIZE 47.0 cm. (W) x 48.0 cm. (D) (ii).HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density = 45±2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression. (iii) ARMRESTS :The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. (iv)TUBULAR FRAME: The powder coated ( DFT 40-60 microns ) tubular frame should be cantilever type & made of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. M.S. ER.W. Tube. (Visitor Chair)
9. Supply and installation of Wooden chair of Dimension - 480W x 420D x 820H UNDERSTRUCTURE:The Understructure is made from Hot pressed rubber wood. BACKREST: The backrest is made up of plywood and foam upholstered with polyester fabric. SEAT:The seat is made up of 12mm thick (7 layers) hot pressed plywood and moulded seat foam upholstered with fabric.
10. Office Table made of Pre-laminated table top of size 1199 X 590 X 735 mm with one drawer unit made of 0.5mm thick CRCA sheet. The table top shall be supported over legs consists of MS ERW round tube of 25.4 x 1.2mm and Cross Horizontal Members including Leg rest of 25.4 x 1.2 mm ERW tube. All steel components be shall be finised with epoxy polyster powder coated DFT 50-60 Micron.
11. Supply and placing of chair with MOULDED PLY SHELL: The Nosh shell is made up of moulded ply in Veneer or Laminate finish. Shell size - 420 mm (W) X 410 mm (D) X 440 (H) X Thickness 12 mm. UNDERSTRUCTURE: The Understructure is made up of Diameter 19 x 1.6 mm thk and 2mm MS plate welded with it. Powder Coating done in Texture Metallic Silver Color having DFT – 50 to 80 micron.
12. Super White' writing grade resin coated steel writing surface conforming to International Standards. A 100% smooth and 100% scratch-free surface ensures maximum pleasure of writing. The surface can also be used for sticking magnets or magnet impregnated objects Satin-finish alloy aluminum (6063-T6) frame and precision engineered paper honeycomb core to make the board 100% warp-free and 100% flat. Can be mounted in landscape as well as portrait orientation on a wall with the help of built-in wall hanging clips Excellent erasibility with no ghost-marks, high scratch-resistance with easy- wipe properties and maximum readability with minimum glare makes the Genius series boards an ideal companion for all training, teaching, display and learning activities Material: Resin Coated Steel Writing Surface, Alloy Aluminum Frame, Paper Honeycomb Core & Virgin ABS Corners. Size of the board: 6 x 4 FeetMagnetic White Board- 6’ x 4’
13. ‘Green' writing grade melamine writing surface (chalk sheet) conforming to IS:2046/1997. A 100% clean and 100% scratch-free surface ensures maximum pleasure of writing. The surface cannot be used for sticking magnets or magnet impregnated objects Satin-finish alloy aluminium (6063-T6) frame and precision engineered paper honeycomb core to make the board 100% warp-free and 100% flat. Can be mounted in landscape as well as portrait orientation on a wall with the help of built-in wall hanging clips Excellent erasibility with no ghost-marks, high scratch-resistance with easy- wipe properties, maximum readability with minimum glare and minimum chalk dust formation with clean & continuous lines of chalk, makes the Genius series boards an ideal companion for all training, teaching, display and learning activities Board Size: 3x4 Feet (90x120 CM). Suitable for use at home, home offices, offices and schools. Works well with all standard chalk sticks Melamine Surface Non-Magnetic Chalk Board-6’ X 4’
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
SBD.pdf
Tender Documents • 1.12 MB
BOQ_82510.xls
BOQ • 0.49 MB
DrawingN.pdf
Additional Documents • 0.47 MB
Download all tender documents and submit your bid