Loading…
Loading…
Tender Value
₹5.2 L
EMD Value
₹5,200
Closing Date
25 Jun 2026, 3:00 pm5d left
Similar tender results from the same govt authority in the past 3 years.
The Commissioner
Thiruthani Municipality
Providing Air Conditioner arrangement in Municipal office Thiruthani Municipality.
2026_MAWS_680511_1
510/2025/E1/03
Open Tender
Materials
30 days
Thiruthani Municipality
Previous Experience
2 documents required · 2 mandatory
₹0
₹5,200
12 Jun 2026
12 Jun 2026
25 Jun 2026
12 Jun 2026
25 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and installation of air conditioner with copper coil for 5 star ratted split type AC unit with 4 KVA capacity automatic voltage stabilizer and Ms stand for fixing out door unit etc complete. | |||||
| 1.01 | 1.50TR | 3 | Nos | - | - |
| 1.02 | 2.00TR | 3 | Nos | - | - |
| 2 | Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay etc complete. | 6 | Nos | - | - |
| 3 | Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unitt etc complete. | 6 | Nos | - | - |
| 4 | Supply and fixing of Ms stand for fixing out door unit etc complete. | 6 | Nos | - | - |
| 5 | Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 7.32 | M2 | - | - |
| 6 | Sub Total | 1 | Nos | - | - |
| 7 | GST 18% | 1 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_817747.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid