| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 4 9 359 P 14 BESIDE SAI BABA TEMPLE RTC COLONY HAYATH NAGAR HYDERABAD 501 505 | HYDERABAD | HAYATH NAGAR | TELANGANA | 501505 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.0 L+₹1.0 L (2.76%)Rejected-AOC 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹39.3 L+₹1.3 L (3.50%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹40.7 L+₹2.7 L (7.14%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹40.9 L+₹2.9 L (7.64%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
22 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
PROVN OF HT OUTDOOR VCBs (VACUUM CIRCUIT BREAKER) AND CONNECTED ITEMS AT HQ 54 INF DIV, 2 LANCER AND BOWENPALLY AREA UNDER GE (U) SECUNDERABAD.
2022_MES_565580_1
GE(U)/SEC/TOKEN/51 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹85,200
Yes
15 Jun 2023
26 Nov 2022
29 Dec 2022
26 Nov 2022
22 Dec 2022
10 Dec 2022
Amount
Supply, install, testing and commissioning of 11 KV Outdoor type RMU one side extensible non-motorized with internal copper bus bars, including of fixed type VCB (Vacuum Circuit Breaker) for normal working voltage 11 KV, 3 Ph, 50C/S, rupturing capacity 350 MVA. module with Air insulated metering module and earthing. All live parts, bus bars, connections of RMU shall preferably be enclosed in one tank to avoid multiple interconnections & sealed for life in robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof 21kA for 1 sec. for tank+Cable Box ,and tested and totally safe for human beings. The gas release & personnel safety with internal arc proof shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/plinth, top release will ensure their safety. The release in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the "Internal fault IAC-AFLR as per IEC 62271-200". Internal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode. Configuration : +V+M Make of switchgear : ABB / SIEMENS / CROMPTON GREAVES
The unit shall include the following items with all necessary standard fitting required at site. (a) 630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity - 1 No. (b) Motor operated 630 A Vacuum circuit breaker having spring stored mechanism. (c) Motor control voltage - 24VDC (d) Three position disconnector/earthing switch downstream vacuum circuit-breaker. (e) Three position single spring mechanism for disconnector/earthing switch. (f) Live Cable LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. (g)Short time breaking current - 21KA/ 3 sec (h) Making Capacity - 52.5kAp (j) Auxiliary contacts - 1NO + 1NC (k) Power frequency withstand voltage - 28KV, Impulse withstand voltage - 75KV (l) Nominal operating gas pressure - 1.4 Bar abs. (m) Enclosure Protection - IP54 (n) Green(ON)/Red(OFF) push buttons to operate VCB. (o) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. (p) Electromechanical type TCS relay (95) (q) Electromechanical type Master trip relay (86) (r) Static type UV Relay with Timer (27+2) (s) Transformer Auxiliary relay for Outgoing feeders (OTI,WTI,Bucholz) (t) Resin cast ring core protection CT plate mounted type : 100/1 A, 5P10, 2.5 VA - 3 Nos (u)Resin cast ring core metering CT plate mounted type : 100/1 A, Cl-1.0, 2.5 VA - 3 Nos (v) Mechanical ON/OFF/EARTH/Spring charge Indication (w) Right angle Non-touch proof boots - 1 Set (R,Y,B)
(x) Bus Connected Air Insulated Metering Module metering module will consisting of following items (i) 3 nos. Single Phase PTs - 11kV/V3/110/V3 ,Cl-0.5 ,50VA (ii) Space Heater with thermostat (iii) Terminal Blocks (iv) 1 x Digital Multi Function Meter ,Cl-0.5 - Elmeasure /Conzerv (v) Battery/Charger . Input Voltage of 230VAC for the battery charger shall be provided at site. (vi) Auxiliary relays for OTI,WTI,Bucholz -Alarm & Trip for all VCBs. (vii) 2 x 8 Window Alarm Annunciator (viii) Hooter Note: All civil works including foundation plinth required for installation is as per requirement of manufacturer design/drawing of switchgear are deemed to be included in quoted rate.
Supply,laying & testing HT electric cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and lay un-reinforced precast concrete cable cover , class , HVP , Type I flat size 300 x 180 x 40 mm laid dry in trenches over under ground cables complete all as specified.
S&F cable route indicator for HT UG cable of 11000 volts bolted with 40x6 mm flat iron member of height 0.60 mtrs and 80 mm CI plate embeded in PCC 1:3:6 type C2 of size 20x20x30 cm block complete all as specified
Supply & lay Galvanised Iron tubing 80mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps, nut bolts and washer as per site requirement complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified.
Earthing (OH/Sub station) with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI strip 32 mmx 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point, commissioning & testing complete. Note : Main earth lead upto 7.5 metre is deemed to be included in this item.
M&L cutting of road/hard standing upto a size not exceeding 30 cm in width and not exceeding 90 cm in depth for laying of HT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed.
LEOENTERPRISES
E M CONSTROL SYSTEM
L and S ENTERPRISES
Srinivash Engineers
SANJEEV CONSTRUCTIONS
omsai thermax engineers
M/s. A&T Enterprises
VBK ELECTRICALS AND AGENCIES PRIVATE LIMITED
POWER CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
recovered-award.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .