Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹48.8 L+₹12,915.80 (0.27%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹51.2 L+₹2.5 L (5.24%)Rejected-Finance NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹99,960
Closing Date
6 Jan 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
SPECIAL REPAIR OF BER COOLING EQUIPMENT AND CERTAIN REVENUE MINOR WORKS AT AFTC AF STN JALAHALLI
2023_MES_629121_1
8833/E8
Open Tender
Electrical and Maintenance Works
Item Rate
151 days
Jalahallii
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹99,960
18 Jan 2024
4 Dec 2023
8 Jan 2024
4 Dec 2023
6 Jan 2024
23 Dec 2023
4 Dec 2023 - 11 Dec 2023
Amount
Supply, install, testing and commissioning of retrofit emission control device suitable for DG set of capacity 100 KVA of Make- Kirloskar, having ceramic carried filter with 94% PM and operational reduction level of CO, NOx, HC reduction up to a level of 75% conforming to condition CPCBs latest regulation on RECD for DG set and including the requirement mentioned below complete all as specified and directed. (i) Filter type: - Ceramic filter with Regeneration (ii) Material of construction: - SS316 (iii) Temperature monitoring: - Temperature sensor (iv) Temperature monitoring sensor:- Before & after filter exhaust gas (v) Differential pressure sensor:-Before and after filter to know the back pressure (vi) Digital indication for monitoring Temp & Pressure (vii) Digital output: - Rs 485 RTU (viii) Inlet connection for RECD – 06 holes of 160 OD (ix) High heat resistance and low exhaust resistance (x) Auto bypass arrangement with respect to back pressure (xi) Digital display with temperature and pressure indication Note:- Contractor has to submit the complete test report of exhaust emission (Engine performance test) without and with RECD from ICAT or recognised NABL accredited lab/ Central or State pollution board.
Supply and fix Inverter AC split unit Indoor/ outdoor complete with smart inverter full HD filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto clean quiet mode, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 1.5 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, Catechin, Silver Ion, Anti Bacterial/ Anti Acarine/ Active Carbon/ Vitamin C/ Dust Filter complete including installation, complete all as specified and directed. Make: Sumsung / LG/ HITACHI / Blue Star/ Carrier
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA,complete all as specified and directed. Make - V-Guard Model No VG 500 or equivalent in Microtek/ AE
Supply and fix Metal clad 20 Amps single pole and neutral enclosure with 2pin and earth plug and socket complete with sheet steel enclosure and controlled with and including 1 no single pole MCB SP 20 Amps, complete all as specified and directed
Material and labour for 25 mm Low density polyethylene pipes (LDPE) of pressure 6kgf/sqcm fixed complete on walls, ceilings including all accessories , complete all as specified and directed (Drain pipe ).
Supply, installation & commissioning of water cooler stainless steel body, electric driven, single phase having storage and nominal cooling capacity of 80/40 ltrs including taking down existing unserviceable one complete all as specified and directed. Make : Blue Star/ Voltas/ Hitachi. Note :- (a) The Contractor shall given a written guarantee of minimum two years from completion of work. (b) Old unserviceable water cooler shall be deposited to MES store yard.
Supply, installation & commissioning of water cooler stainless steel body, electric driven, single phase having storage and nominal cooling capacity of 120/60 ltrs including taking down existing unserviceable one complete all as specified and directed. Make : Blue Star/ Voltas/ Hitachi. Note :- (a) The Contractor shall given a written guarantee of minimum two years from completion of work. (b) Old unserviceable water cooler shall be deposited to MES store yard.
Supply , installation and commissioning of water cooler fully stainless steel electric driven single phase having approximate storage capacity and nominal cooling capacity of 150/150 Ltrs, complete all as specified and directed.Make: Blue Star/ Voltas/ HITACHI Note: (a) The Contractor shall given a written guarantee of minimum two years from completion of work. (b) Old unserviceable water cooler shall be deposited to MES store yard.
Material and labour for PVC drain hose pipe size 32mm dia LDPE waste hose pipe fitted to water cooler complete all as specified and directed.
Material and labour for PVC hose connection pipe 300 mm length both ends having brass coupling threaded for 15mm GI tubing of standard length, complete all as specified and directed.
Supply and laying of GI tubing medium grade 15 mm bore laid on floor/wall including all fittings such as bend,tea, union, elbow etc, complete all as specified and directed.
Supply and fix stop valve 15 mm dia, cast copper alloy chromium plated high pressure with crutch or butterfly handle screwed both ends for GI pipe/fittings including removing old unserviceable item complete all as specified and directed.
Cutting existing steel tubing / PVC pipe for alterations or additions for 25/32mm, complete all as specified and directed.
Supply and fix Inverter AC split unit Indoor & outdoor (5star rating) complete with smart inverter full filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 2 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, / Active Carbon/High density dust Filter complete including installation and removing the old one and deposit to E/M store all as specified and directed. Make: Sumsung / LG/ HITACHI / Blue Star/ Carrier.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete and including removing the old one and deposit to E/M store, complete all as specified and directed.. Make :- V Guard, Microtek, AE.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing, complete all as specified and directed.
Material and labour for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size, complete all as specified and directed. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and fix Refrigerator, electric driven,AC,230 V (single phase) of capacity 195 Ltrs,BEE 3 star rated including removing the old one and deposit to E/M store, complete all as specified and directed. Make: Voltas/LG/Sumsung
Supply and fix Refrigerator, electric driven,AC,230 V (single phase) of capacity 310 Ltrs,BEE 2 star rated including removing the old one and deposit to E/M store , complete all as specified and directed.. Make: Voltas/LG/Sumsung
Supply and fix Refrigerator, electric driven,AC,230 V (single phase) of capacity 360 Ltrs,BEE 2 star rated including removing the old one and deposit to E/M store, complete all as specified and directed.. Make: Voltas/LG/Sumsung
Supply, installation and commissioning of Metal top Deep freezer, electric driven,AC,230 V (single phase) of capacity 405/425 Ltrs including removing the old one and deposit to E/M store, complete all as specified and directed.. Make : Blue Star/ Voltas/ Haier
Supply and fix Inverter AC split unit Indoor & outdoor complete with smart inverter full filter, bio sleep smart server, turbo cooling, twin BLDC compressor, wide air flow blade, antibacterial coating, dehumidification, auto restart 24 hours timer, auto cooling fan mode, 4 step fan speed, of capacity 1.5 TR, operating on 230 Volt single phase AC supply, with cordless remote control unit and Filter Configuration with, / Active Carbon/High density dust filter complete all as specified and directed. Make: Sumsung / LG/ HITACHI / Blue Star/ Carrier
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA, complete all as specified and directed. Make - V-Guard Model No VG 500 or equivalent in Microtek/ AE
Material and labour for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size, complete all as specified and directed. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
Material and labour for wiring for circuit complete sub main wiring with 2 X2.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 2.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size, complete all as specified and directed. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fix Modular Switch,1 Module,16 Amps &Socket outlet 2in1, 6/16 Amps,2 Module,230 Volts,AC including modular metal flush box and modular cover plate with frame (inner & outer) 3 module, complete all as specified and directed. Make : Legrand/ ABB/ Anchor
Supply, errection, testing and commissioning raising and lowering type not less than 16Mtr height high mast system shaft in two section suitable for 44m/s wind speed aling with head frame, luminaire carriage suitable for up to 16 luminaires in symmetrical arrangement and other accessories manufactured in factory including raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box. HIGH MAST SYSTEM: Height of the mast not less than 16Mtr, Design standard PLG 07 of ILP, Basic Wind speed as per IS:875 Part III Design life - 25 yrs.; Material construction as per S355 grade as per BS - EN10 025; Base dia - 410mm & Top dia - 150mm; with plate thickness : Bottom - 3mm & Top - 3mm. Cross section of the mast shall be 20 side polygon with BS EN ISO 1461 standard galvanisation. With GI single spike lighting protection finial. The high mast shall have 8 nos of foundation bolt with a PCD of 490mm of TS600 type with 30mm dia and 850mm length. Base plate with a dia of 570mm and thickness of 25mm LUMINAIRE CARRIAGE: Luminaire carriage shall be made of 50NB ERW class B MS Pipe with diameter of carriage ring at 535mm. Construction shall be with 8 arms which are welded and 2 sections capable of holding 16 luminairies. TRAILING CABLE: 5 core 2.5sq mm copper cable with EPR insulation and PCP sheathed. WINCH/POWER TOOL: Winch with double drum, SWL 750Kg integral motor with 1HP capacity with 6 pole, single speed. STAINLESS STEEL WIRE ROPE: Stainless Steel wire with AISI 304 grade and 7/19 construction with 2/3 wire rope of 6mm dia and a 2x2350Kg breaking load capacity, complete all as specified and directed.. Make: Bajaj Model No: BHMRL16C/CG or its technical equivalents other make. Note: The rate quoted shall be inclusive of the following:
(a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set (b) Supply of suitable copper conductor cable, glands, lugs and wiring from panel to light fittings - 01 Job (c) Construction of suitable shallow RCC foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 metre depth with all material and labour all as per Manufacturer's design of foundation drawing as approved by GE. (d) Erection and commissioning of the high mast with the help of suitable equipment. (e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour. (f) Provision of Aviation obstruction light LED type. (g) Provision of lightening arrestor spike. (g) The Contractor shall submit OEM technical specification of High mast for approval of acceptance Officer before placing order. (h) The Contractor shall submit warranty & TC before claiming payments.
Note for Item No 27 & 27.01 here in above : (i) The earth work in any strata i.e. excavation, return filling, removal , RCC foundation with foundation bolts manufactured from special steel with nuts, washers, anchor plate and template deemed to be included in unit quoted rate.(ii) The M/L for LED flood light fittings & Control panel required will be measured and paid separately under relevant Schedule items.
Supply and fixing LED floodlight 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD includes and corrosion resistant complete with driver and lamp. Protection complete including street light fitting bracket nuts, bolts, washers, complete all as specified and directed. Make - Bajaj/CG/Phillips
Supply and fix MS sheet metal enclosure of suitable size made out of 2 mm thick double door, including provision of opening for cable entry duly painted with two coats of synthetic enamel paint over one coat of red oxide and suitable fixing MS clamps 40x5mm thick bend to shape drilled with holes suitable for fixing to PCC / Steel tubular pole, complete all as specified and directed. :- (a) Aluminium bus bar chambers 4 strip 300 mm long 100 Amps (b) MCB SPN 40A 10KA "C" 03 Nos (c) Digital Time switch 3P Module, weekly programme with battery bach up 100 hrs Current of capacity 16 Amps with change over - 01 Nos. Make - Schneider/ Indo asian/ Standard
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of CI/DI/GI pipes, complete all as specified and directed.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm in any type of soil, complete all as specified and directed.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 , complete all as specified and directed.. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for payment.
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench , complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and directed. Make: Havells, Polycab,RPG Asian
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:2:4 with 20 mm aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm aggregate foundation and coping as per TD drawing including dismantling & removeing from the site damaged pole one complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of alu paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole , complete all as specified and directed.
Supply and fixing weather proof PVC junction box for street light control made out of not less than 2mm thick of size 250 mm x 250 mm x 100 mm internal dia complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No, MCB Sp 10 Amps 10 KA 01 No including connecting up with the electrical connections and fixing and clamping , complete all as specified and directed. Make : Sintex/Havells/CG
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core, complete all as specified and directed. Make : Havells, Polycab, Plaza
Supply and fix new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover, complete all as specified and directed. having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 70 watt.Make: Havells/Philips/CG/ Bajaj
Supply, install surge protection device (SPDs) suitable for high risk level installations TP with enclosure and connecting up to existing 3 phase rating 440V, 75 KA and connecting up to the earth terminal with copper wire of 50 sq.mm MCB DB with suitable wiring and connected accessories as per site reqmt complete all as per specified and directed. Make: Legrand, L&T, Schneider
Material and labour for Point wiring complete with 1. 5 Sq mm single Core PVC insulated FRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metallic conduit / casing and capping with all fittings such as bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in wall, with 3 mm thick laminated sheet top cover with brass screws and cup washers for housing the switches, sockets, regulators etc. all as specified and directed complete for One light point controlled by one way switch. Note:- The rates are deemed to be included cutting chasing of any description of wall and making good the disturbed surface.
Material and labour for Point wiring complete with 1. 5 Sq mm single Core PVC insulated FRLS cable, 1100 volts grade unsheathed with multi stranded copper conductor drawn through and including PVC rigid non metallic conduit / casing and capping with all fittings such as bend, end caps etc. fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories including provision of 1.5 Sq. mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in wall, with 3 mm thick laminated sheet top cover with brass screws and cup washers for housing the switches, sockets, regulators etc. all as specified and directed complete for one exhaust fan point controlled by one way switch. Note:- The rates are deemed to be included cutting chasing of any description of wall and making good the disturbed surface.
Supply and fix Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws and writing MES No with synthetic enamel paint , complete all as specified and directed.. Make- havells model-Ventil Air-DB or equivalent in bajaj, Almonard.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one , complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate is deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate. (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. (iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate. (iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. (vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately). (vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern. (viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. (x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained. (xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period. (xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. (xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material. (xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge. (xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Supply and fix Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one , complete all as specified and directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit including taking down , complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out soft/loose of soil , complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out ,returning, filling in and ramming earth or broken rubble mixed with earth, in layers n exc 25 cm in hard/dense soil, watering and removing surplus soil to a distance n exec 50 m and making good surface in hard/dense of soil , complete all as specified and directed.
Material and labour for Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) as in foundation, fillings, posts and mass, concrete complete all as specified and directed
Material and labour for Precast Concrete block masonry 1:3:6 type C1 using 20 mm graded stone aggregate exc 10cm width and setting in cement mortar 1:6 complete all as specified and as directed.
Dismantling floor hearth or wall (ceramic/mosaic) tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl aii quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Material and labour 10 mm thick cement plaster in CM 1:6 on fair faces of brick work/concrete etc finished even and smooth without using extra cement, complete all as specified and directed..
Material and labour Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of chalk whiting primer, complete all as specified and directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each, complete all as specified and directed.
Supply and fix 2nd class hardwood Plain, solid, straight, chowkatSupply and fix rames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
Supply and fix 35mm thik plain, framed, factory made panelled shutter(two panel) with lock rail and panel of 9 mm B.W.P. commercial veneering particle board on both faces. The size of rail and stile as per IS : 1003(Part-1), kiln in seasoned and chemically pressure treated, complete all as specified and directed.
Supply and fix MS butt hinges100mm long medium weight, cold rolled, complete all as specified and directed.
Supply and fix 150 mm long extruded alu alloy handles, fabricated type, anodised, complete all as specified and directed.
Supply and fix 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple bolt type and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed.
Supply and fix 200mm long Aluminium, anodized barrel tower bolts of extruded section and fixed, complete all as specified and directed.
Material and labour Preparation of new wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Supply and fix Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Supply and fix 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50sqm each, complete all as specified and directed.
Supply and fix 18/19mm thick Pre-laminated particle board, exterior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination including fixing of teak wood beading on open edges in any position such as cup boards, drawers shutters etc. fixed with screws and incl all fittings, tower bolt, handle, knob, magnet to timber frame work , complete all as specified and directed.
Supply and fix Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed.
Supply and fix Pre-Painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Material and labour framed work as in doors or gates of angle or other section with gusset plates, braces etc complete drilled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete conforming to Fe 290,(Gde-E-165 quality), complete all as specified and directed.
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
Supply and fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming o IS 1161-1998 grade St 240 complete all as specified and directed.
Material and labour for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description, not exc 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
Material and labour 100 mm thick, Cement concrete 1:2:4, type B2 using 40 mm graded stone aggregate as in paving's, hard standings and similar work, complete all as specified and directed.
Material and labour for plain cement concrete type D2 1:4:8 in 40 mm graded aggregate for the foundation of pole complete all as specified and directed.
Material and Labour for plain cement concrete type C1 1:3:6 using 20mm graded stone aggregate for coping for poles including necessary form work to exposed surfaces finished smooth and even, complete all as specified and directed. Note :- An amount of Rs 1467.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
devan enterprises
UNIVERSAL ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .