Superintending Engineer
IWD IIT Kanpur
SITC of 2 x4 TR Air cooled floor standing tower type split Air conditioners with accessories at KD server room of IIT Kanpur
2026_IITK_929073_1
21/AC/SE/2026/220
Open Tender
Electrical Works
Percentage
60 days
IIT Kanpur
As per tender
2 documents required · 2 mandatory
₹0
₹5,209
6 Oct 2026
6 Oct 2026
16 Oct 2026
6 Oct 2026
15 Oct 2026
6 Oct 2026
6 Oct 2026 - 13 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing and Commissioning (SITC) of Air-Cooled Floor Standing Tower Type Split Air Conditioner complete with Indoor Unit (IDU) and Outdoor Unit (ODU), including vacuumization and nitrogen pressure testing of the existing soft/hard drawn copper refrigerant piping of suitable sizes for suction and liquid lines, complete with all necessary fittings and accessories. The system shall use R-32/R-410A/R-407C eco-friendly refrigerant and shall be provided with a wireless remote control with batteries. The unit shall be capable of performing cooling, dehumidification, and air circulation, and shall be equipped with a scroll/rotary compressor, complete as per Institute specifications and as required. Note: 1) The existing refrigerant piping shall be subjected to nitrogen pressure testing and vacuumization prior to commissioning. Any leakage detected during testing shall be rectified before commissioning of the system. 2) The defect liability period (DLP) shall be upto 1 year from the date of installation and warranty on Compressor & PCB shall be as per OEM. | |||||
| 1.1 | 4.0 TR capacity (Non-Inverter,3 Phase 415 V, Cooling only) | 2 | Each | 1,16,000 | ₹2,32,000 |
| 2Providing & fixing Unplasticized Polyvinyl Chloride (uPVC), having thermal stability for cold water supply, including all uPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer In Charge. Internal Work - Exposed on Wall | |||||
| 2.1 | 25 mm nominal outer Dia pipes | 5 | Mtr | 178 | ₹890 |
| 3Supply & fixing of angle iron frame made of 25/32 mm thickness 5 mm for mounting of outdoor unit size, duly painted and finished with canopy and vibration isolation pad if required complete as reqd for Tower AC | |||||
| 3.1 | Upto 4.0 TR capacity (Floor Mounted) | 2 | Nos | 2,949 | ₹5,898 |
| 4Supply, laying, testing and commissioning of approved make FRLS PVC/ XLPE insulated Power / Control copper cable of on surface / recessed complete as required. | |||||
| 4.1 | 4 core x 4 sq. mm | 10 | RMT | 289 | ₹2,890 |
| 5 | Supply, fixing of copper piping (3/8" & 5/8") or (3/8" & 6/8")as required with 19 mm thick Class 'O' nitrile insulation on surface / recessed with flair nut, clamps etc. complete as required. | 10 | Mtr | 1,876 | ₹18,760 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 1.05 MB
BOQ_976338.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .