| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | Admitted-Finance |
| 2 | Admitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | Admitted-Finance |
| 3 | Rejected-Technical PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | Rejected-Technical Disqualified |
| 5 | Rejected-Technical | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹81,403
Closing Date
18 Jun 2025, 3:00 pmClosed
CME
CME VOCPA
Supply and fixing of Current transformers along with relays for HT Breakers
2025_VOCPT_236762_1
MEE-ELEC0ESTW/5/2025/6846
Open Tender
Electrical Works
Works
90 days
vocpa
As per the tender conditions
8 documents required · 8 mandatory
₹0
₹81,403
Yes
28 Jul 2025
29 May 2025
19 Jun 2025
29 May 2025
18 Jun 2025
29 May 2025
Amount
Supply and fixing of Current Transformer with the following specifications and drawing. Location: Auto Substation, HT Breaker: C&S Ratio: 300-200-100/1-5A, HSV:24KV, type: Resin cast, Core.I: 10VA, Class:0.2S, Core.II: 10VA, Insulation: Cl B, Frequency: 50Hz, Class: 5P10, BIL: 50KV/125KVp, STC: 25KA for 3 Sec, STD: IS/IEC-60044-1, Make of CT: Nortex Marketing
Supply and fixing of Current Transformer with the following specifications and drawing. Location: Centralized Substation, HT Breaker: System Control, Ratio: 300-200-100/1-5A, HSV:24KV, type: Resin cast, Core.I: 15VA, Core.II: 15VA, Class:0.2S, Insulation: Cl B, Frequency: 50Hz, Class: 5P10, BIL: 50KV/125KVp, STC: 25KA for 3 Sec, Make of CT: Cortina Electriks Salem
Supply and fixing of Current Transformer with the following specifications and drawing furnished as Picture:3. Location: Point of Supply, HT Breaker: Schneider, Ratio: 300-200-100/1-5A, Insulation Class: E, Burden:2.5VA, Class: 5P10, HSV:24KV, type: Resin cast, Temperature Category: -5/50deg C, STC: 21KA/3 Sec or 25KA/1Sec, Insulation level: 0.75/3Kv Make of CT: Narayanan Powertech Pvt Ltd
Supply and fixing the relay with features of the following factors at HT Breakers. Make: ABB Model No: REF615 Over Current, Earth fault, Sensitive earth fault, Phase unbalance, thermal overload, Breaker failure, disturb recording triggered, CB condition monitoring and trip circuit failure. 24V DC Power to be availed from the source available at each breaker
SHRI VAARI ELECTRICALS PVT LTD (BID ID -862994)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .