Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94,895.60Accepted-AOC WARD NO 09 KALYASNPUR KALMDI KOTMA KOTMA ANUPPUR MADHYA PRADESH 484334 | KOTMA | ANUPPUR | MADHYA PRADESH | 484334 | ₹94,895.60 | L1 | Accepted-AOC Techno commercially accepted L1 bidder |
| 2 | L2₹1.1 LRejected-Finance MINERS BASTI MINERS COLONY WARD NO 04 BIHARI HOTEL R N SINGH COMPLEX BIJURI ANUPPUR MADHYA PRADESH 484440 | ANUPPUR | MADHYA PRADESH | 484440 | ₹1.1 L | L2 | Rejected-Finance Rejected as bidder is not L1 bidder |
| 3 | L3₹1.6 LRejected-Finance VILL KAZIYAPUR POST SURATGANJ TAHSHEEL RAMNAGAR KAZIYAPUR NEAR JHEEL LUCKNOW UTTAR PRADESH 227115 UDYAM UP 14 0003184 | 227115 | ₹1.6 L | L3 | Rejected-Finance Rejected as bidder is not L1 bidder |
| 4 | L4₹2.2 LRejected-Finance | ₹2.2 L | L4 | Rejected-Finance Rejected as bidder is not L1 bidder |
| Sl No | Description | Qty | Unit | AJAY KUMAR SINGH L3 | M/s. SWETA ELECTRICALS L2 | M/s IQBAL KHAN L1 | SONI ELECTRICALS L4 |
|---|---|---|---|---|---|---|---|
| 1.00Re-arrangement of overhead lines to supply power for installation of sewage treatment plant (STP) at Jamuna Township of Jamuna Kotma Area. | |||||||
| 1.01 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. | 9 | each | 4,800 ₹43,200 | 4,500 ₹40,500 | 4,500 ₹40,500 | 6,800 ₹61,200 |
| 1.02 | Supplying of channel iron 75 mmX40mmX6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. | 9 | each | 442 ₹3,978 | 1,000 ₹9,000 | 400 ₹3,600 | 440 ₹3,960 |
| 1.03 | Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required. | 45 | each | 90 ₹4,050 | 80 ₹3,600 | 110 ₹4,950 | 110 ₹4,950 |
| 1.04 | Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required. | 5 | each | 100 ₹500 | 80 ₹400 | 110 ₹550 | 120 ₹600 |
| 1.05 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 1 | each | 3,000 ₹3,000 | 3,000 ₹3,000 | 3,000 ₹3,000 | 3,910 ₹3,910 |
| 1.06 | Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required | 535 | kg | 135 ₹72,225 | 50 ₹26,750 | 40 ₹21,400 | 180 ₹96,300 |
| 1.07 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. | 214 | kg | 48 ₹10,272 | 40 ₹8,560 | 30 ₹6,420 | 59 ₹12,626 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | 24,700.5 ₹24,700.50 | 16,525.8 ₹16,525.80 | 14,475.6 ₹14,475.60 | 33,038.28 ₹33,038.28 |
Tender Value
₹2.3 L
EMD Value
₹3,000
Closing Date
8 Dec 2025, 6:00 pmClosed
SO EnM JK Area
GM Office JK Area
Rearrangement of LT overhead lines to supply power for installation of sewage treatment plant at Jamuna Township JK Area
2025_SECL_347962_1
SECL/JK/SO(EnM)/eNIT/25-26/56
Open Tender
Electrical and Maintenance Works
20 days
Jamuna Kotma Area
as per NIT
5 documents required · 5 mandatory
₹3,000
10 Mar 2026
25 Nov 2025
9 Dec 2025
25 Nov 2025
8 Dec 2025
26 Nov 2025
25 Nov 2025 - 1 Dec 2025
Re-arrangement of overhead lines to supply power for installation of sewage treatment plant (STP) at Jamuna Township of Jamuna Kotma Area.
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Supplying of channel iron 75 mmX40mmX6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required.
Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Tendernotice_2.pdf
PDF • 1.86 MB
Tendernotice_3.pdf
PDF • 1.12 MB
BOQ_360767.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid