Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance GATE NO 3 DIBRUGARH NEAR LANCO POWER PLANT ANPARA SONEBHADRA | ANPARA | SONEBHADRA | UTTAR PRADESH | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical PQC NOT QUALIFIED |
Tender Value
₹23.9 L
EMD Value
₹47,800
Closing Date
13 Jul 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Office of SE OMC 4 BTPS Anpara
Routine and breakdown maintenance and testing of 400 132 kv A BTPS switchyard equipments and associated auxiliaries.
2021_RVUNL_577253_1
05/EMD-III/BTPS/2021-2022
Open Tender
Electrical Works
Fixed-rate
365 days
BTPS Anpara
As per tender document
3 documents required · 3 mandatory
₹1,180
Dy CAO CFA BO BTPS Anpara
₹47,800
2 Aug 2021
26 Mar 2021
13 Jul 2021
27 Mar 2021
13 Jul 2021
27 Mar 2021
120 days
Amount
PART- A: ROUTINE MAINTENANCE WORKS
Round the clock operation of air compressors of ‘A’TPS daily (including SUNDAYS & HOLIDAYS).
Routine Maintenance of 400 KV‘A’ TPS, Switchyard in Anpara.
Routine Maintenance of 400 KV‘B’ TPS, Switchyard in Anpara.
Routine Maintenance of 132 /33/11KV‘A’ TPS, Switchyard in Anpara.
Routine Maintenance of 100MVA ICTs, 10MVA CS-1&2, 400/33KV reactor 220/48V battery system & MCC room etc.
PART- B: BREAKDOWN MAINTENANCE WORKS Providing assistance in the following works
Dismantling, erection, commissioning & testing of 400/132KV Lightning arrestor & CVT.
Dismantling, erection, commissioning & testing of 400KV CT.
Dismantling, erection, commissioning & testing of 132KV CT.
Preventive maintenance of 400KV Sequential /Pantograph isolator including bearing O/H
Preventive maintenance of 132KV Sequential isolator including bearing O/H
Providing shunts/ restrengthening /replacement of 400/132KV damaged jumper.
Centrifuging of oil of 100MVA ICTs/ Reactor / 10MVA Transformer per day.
Replacement of pantograph isolator of one pole
Replacement of support insulator of pipe bus of 400/132KV along with associated work
Rewinding of induction motors of 3 phase, 415-430 volt and 220V DC motors of following rating.
Up to 1.0 KW
Above1.0 KW & up to 2.5 KW
Above 2.5 KW & up to 5.0 KW
Overhauling works
Overhauling of Motorised Drive mechanism box of 400/132KV isolators
Overhauling of Drive mechanism box of 400/132KV earth switch
Overhauling of 0.4KV circuit breaker installed in MCC room.
Replacement of Male & or Female contacts of one pole of 11KV MOCB breaker.
Replacement one pole of 11 KV VCB breaker
Replacement of wave trap of one phase
Replacement of trapeze assembly
Replacement of Pilot Valve of 400 KV BHEL/Siemens SF6 Breaker
Erection and Dismantling of Scaffolding in 132/400 KV switchyard per pole
Replacement of one Buchholz relay of ICT/Reactors/10 MVATransformer.
Shifting of one 10 –14 KL capacity oil tank
Replacement of PRV of 100MVA,400/132/33KV ICT
Attending hot spot from 400KV/132KV Switchyard Equipments.
Attending air leakages from cooler tubes of IR make type 15T-2 air compressors by replacing the faulty tube with new/repaired tube:
Attending problem of safety valve floating of various stages of 15T-2 compressors:
Attending mal-functioning of 60Kg/cm2 air pressure reducers and solenoid valves by replacing O-rings, gaskets & seals
Attending problem of air leakage/passing from 60Kg/CM2 NRV by replacing faulty valves seals, spring etc
Checking and attending air leakage from 400/132 KV S/Y compressed air line stop valves, NRV etc
Brazing, cutting and jointing the finned tube cooler nest for attending the air leakage from 60Kg/cm2 finned tubes of stage-I,II,III of 15T-2 compressors are to be repaired
Brazing, cutting/jointing works on 30Kg/cm2 compressed air pipe line of 400/132 KV S/Y:
Replacement of desiccant material & overhauling of heat less air drier.
Replacement of crank shaft of 15T-2 IR make compressors
Disconnecting and connecting of terminal connectors at transformer bushing of ICT/GT per phase
Shorting of all the three phases of Generator bay
PART- C: B Testing Jobs
400 KV SF6 Circuit breaker timing test.
132 KV ABCB/SF6 Circuit breaker timing test.
132 KV ABCB/SF6 Circuit breaker static contact resistance measurements.
400 KV SF6 Circuit breaker static contact resistance measurements.
400 KV Centre break isolator contact resistance measurement.
132 KV Centre break isolator contact resistance measurement.
Testing of 400 KV CT & its connected circuit.
Testing of 132 KV CT & its connected circuit.
Testing of 400 KV CVT/PT & its connected circuit.
Testing of 132 KV CVT/PT & its connected circuit.
Testing of 400/132 KV LA.
Testing of protection and tripping relays of 132/6.9 KV & 132/11KV Transformers
Testing of 11/33 KV MOCB/Vacuum Circuit breaker(R,Y&B phase)
Testing of 11/33KV CT and it’s connected circuit.
Circuit Breaker Timing Test Kit
Contact Resistance Measurement test kit
Primary Injection Test Kit
Testing of Distance Protection numerical relays (REL670, 7SA522, P543 and P542)
Testing of Transformer Differential, REF, etc. Protection numerical Relay (P645).
Testing of Over Current, Earth Fault, etc. Protection numerical Relay (P142).
Testing of 11 KV Over Current, Earth Fault, etc. Protection numerical Relay (VAMP).
Relay Test Kit
M/S SHYAM ERECTORS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .