GE (North) Meerut Cantt PIN 250001
Maint repair for internal electrification and other related works in OTM Accns of CDA (Funds) and MD Accns of CDA Army Lekhanagar under AGE EM I of GE North Meerut Cantt.
2020_MES_389441_1
8205/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Class E
Category b i
13 documents required · 13 mandatory
₹500
GE (North)
₹36,000
Yes
8 Dec 2020
23 Oct 2020
23 Nov 2020
23 Oct 2020
21 Nov 2020
7 Nov 2020
Amount
Taking down copper/aluminium point wiring (ligh, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc all as specified.
Taking down carefully all type of sub main wiring any core including batten / conduit and making good to disturbed surface as matching to existing complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, Fire Retardant, conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, sunken zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly including cutting holes in or through the walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as directed for (a) One light/fan/bell point wiring controlled by one, one way switch/bell push button.
(b) All as per Srl item No 03 here-in-before but one out let socket point 3pin 5 amps on independent board.
(c) All as per Srl item No 04 here-in-before but on the same board with other switches
All as per Srl item No 03 here-in-before but using 2.5 sqmm copper conductor for with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed.
All as per Srl item No 03 here-in-before but using 4 sqmm copper conductor for with 4 sqmm earth wire for one 20 amps socket outlet on independent board all as directed.
All as per Srl item No 03 here-in-before but for supply and drawing 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into existing conduit after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as directed for One light/fan/bell point wiring controlled by one, one way switch/bell push button.
All as per Srl item No 8 here-in-before but one out let socket point 3pin 5 amps on independent board.
All as per Srl item No 09 here-in-before but on the same board with other switches
All as per Srl item No 8 here-in-before but using 2.5 sqmm copper conductor and with 2.5 sqmm earth wire for one 15 amps socket outlet on independent board all as directed.
All as per Srl item No 8 here-in-before but using 4 sqmm copper conductor and with 4 sqmm earth wire for one 20 Amps socket outlet on independent board all as directed.
All as per Srl item No 03 here-in-before but with sunk zinc coated pressed steel terminal boxes suitable for modular fixtures including suitable Modular box, base plate and outer plate all as directed for One light/fan/bell point controlled by one, one way modular switch 06 Amps.
All as per Srl item No 13 here-in-before but One 06 Amps socket outlet point on independent board controlled by one, one way modular switch 06 Amps.
All as per Srl item No 13 here-in-before but One 06 Amps socket outlet point on same board controlled by one, one way modular switch 6 Amps.
All as per Srl item No 13 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable with earth wire 2.5 sqmm for one 16 Amps socket outlet point on independent board.
All as per Srl item No 13 here-in-before but with 4 Sqmm FR PVC insulated and FR PVC unsheathed stranded copper conductor cable for and 4 Sqmm used as earth wire for indpendent 20 Amps socket outlet point on independent board.
S&F switch piano flush type, 5A, AC, 240V, one way ISI Marked all as specified.
S&F switch piano flush type,15A, AC, 240V, one way ISI Marked and as specified
S&F Bell Push, Flush type, 5A, AC, 240V, ISI Marked and as specified
S&F socket outlet flush type, 5A, 5pin, AC, 240V ISI Marked and as specified
S&F socket outlet flush type, 15A, 6pin, AC, 240V ISI Marked and as specified
S&F Electronic 5 Step Fan Regulator, 240V, AC, 240V, ISI Marked and as specified
S&F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified.
S&F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked and as specified.
S&F Modular Bell Push, 1 module, 6A, AC, 240V, ISI Marked and as specified.
S&F Modular Step Fan Regulator, 2 module, 120W, AC, 240V, ISI Marked and as specified.
S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
S&F in repairs lamp holder, PVC / Polycarbonate type with batten back plate, AC, 240V, Pin type, ISI marked all as specified.
S&F in repairs modular Power Unit 20A, 3pin, AC, 240V ISI Marked incl PVC Box all as specified..
S&F in repairs fan Condenser 2.5 mfd 240 Volts ISI marked all as specified.
S&F in repairs fan Condenser 3.15 mfd 240 Volts ISI marked all as specified.
S&F in repairs Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked all as specified.
S&F in repairs Call Bell, AC, 240V, SP, ISI Marked all as specified.
S&F in repairs LED Recess mounted, ceiling panel, 2'x2', 36 watts, 240V light fitting with heat exchanger unit all as specified.
S&F in repairs LED Wall mounting fancy light fitting with polycarbonate diffuser prewired incl 9 Watts LED lamp Make : Havells, Model : Beetle or equivalent model of Make : Philips /Wipro complete all as specified and directed.
S&F in repairs LED tube light fitting surface / pendent mounting, decorative box type CRCA batten, 4 feet, 240V, 20 Watt, including T-8 poly carbonate diffuser type 20 watt rectrofit tube rod all as specified. .
S&F in repairs integrated LED tube light fitting surface mounting, Poly carbonate batten, 4', 240V, T5, 20 Watt all as directed.
S&F in repairs integrated LED tube light fitting surface mounting, Poly carbonate batten, 2', 240V, T5, 9/10 Watt all as directed.
S&F in repairs Retrofit polycarbonate diffuser type 20 watt retrofit LED tube rod 4 feet, 240V all as directed.
----------------BLANK---------------
S&F in repairs IP65, Post Top energy saving spun alluminium landscape luminaire with 15 watts high power LEDs of Make : Havells Model : Ruby (Clear) / Coral (Opal) or equivalent model of Make : Philips / Wipro complete all as specified and directed
S&F in repairs 25 Watt prewired LED street light luminaire incl 32mm OD GI pipe bracket, two nos mounting clamps with nuts, bolts and washers complete all as directed.
S&F in repairs LED Driver suitable for any make or model LED street light fitting 25 to 45 Watts, 240V all as directed.
----------------BLANK---------------
S&F in replacement, 15 Watts LED lamp 2 pin with B22 base, clear acrylic diffuser, power factor .90, 100 lumens per watt all as directed.
All as per Srl item No 47 here-in-before but 12 Watts
All as per Srl item No 47 here-in-before but 9 Watts
All as per Srl item No 47 here-in-before but 6 Watts
----------------BLANK---------------
S&F in repair Metallic Enclosure, SPN DB, 240V, AC, 4 way, double door with 200Amps rated busbar ISI Marked and as specified.
All as per Srl item No 52 here-in-before but 8 way with 200Amps rated busbar.
All as per Srl item No 52 here-in-before but 12 way with 200Amps rated busbar.
All as per Srl item No 52 here-in-before but TPN DB, vertical mounting, 415V, 4way with 200Amps rated busbar, double door.
S&F in repair MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked all as specified.
S&F in repair Isolator DP, 40A, AC, 240V, ISI Marked all as specified.
S&F in repair Isolator 4P, 63A, AC, 415V, ISI Marked all as specified.
S&F in repair Isolator 4P, 100A, AC, 415V, ISI Marked all as specified.
----------------BLANK---------------
S&F in repairs, 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 18KA with Thermal - Magnetic Release.
All as per Srl item No 61 here-in-before but 100Amps.
All as per Srl item No 61 here-in-before but 200Amps. 25KA
S&F in repair 1100V grade PVC sheathed flexible two core cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked.
S&F in repair copper cable 1.5 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed.
S&F in repair copper cable 2.5 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed.
S&F in repair copper cable 4 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed.
S&F in repair copper cable 6 Sqmm copper multistandard PVC insulated FR, 1100V grade all as directed.
Supply only insulation tape roll 20 mm wide 15 Mtr long ISI mared all as directed. Make: Steelgrip / Kinjal / Anchor
S&F in repairs BEE 5 star rated Energy Saving Ceiling fan, 1200mm swee, 50 watts, AC 230V including taking down old unserviceableone and depositing to MES store complete all as specified and directed. Make : Havells Model : Fusion ES or euquivalent model of Make Orient / Crompton
All as per Srl item No 70 here-in-before but 1400mm sweep
S&F in repairs, Wall fan, 450mm sweep, AC, 230V incl T/D old u/s one and depositing to MES all as directed.
S&F in repairs, PVC fresh air fan, 250mm sweep with lovers, AC, 230V incl T/D old u/s one and depositing to MES all as directed.
All as per Srl item No 73 here-in-before but 200mm sweep.
M&L for making opening in the wall for fixing exhaust fan up to 250mm/300mm, plastering work, making good the surfaces as directed.
S&F in repairs, connect, On Load Change Over Switch, 4P, 150 Amps, 415 volts with metallic enclosure all as directed.
All as per Srl item No 76 here-in-before but 100 Amps
S&F in repairs, connect, switch disconnector with kit kat fuse in metallic enclosure 415 V, TPN, 150 Amps all as directed.
All as per Srl item No 78 here-in-before but 100 Amps
Material and labour for 3 phase sub main wiring with 06 Sqmm nominal cross sectional area, four run of single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FR- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including two run of continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 32mm dia, medium grade with all PVC conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note :- One meter of conduit along with 6x6 sq mm wire shall be measured as one unit length.
All as per Srl item No 80 here-in-before but single phase sub main wiring with 2 run 6Sqmm + 1run 6Sqmm earth in 25mm dia PVC conduit (3x6Sqmm - one unit length)
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with TMT bar 8mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as directed.
S&F in repair RCCB / ELCB, double pole, AC, 40A, 30mA, 240V ISI Marked all as specified.
S&F in repair RCCB / ELCB, four pole, AC, 63A, 30mA, 240V ISI Marked all as specified.
S&F in repairs, connect, tamper proof Electronic KWh meter with LED display, 1 phase, 5-30A incl T/D old u/s one and depositing to MES.
All as per Srl item No 85 here-in-before but 3 phase 10 - 60 A.
S&F in repairs BEE 5 star rating Electric water storage heater, 25 Ltr, AC, 230V incl T/D old u/s one and depositing to MES all as directed. Make : Havells / Recold / Bajaj / Venus
Carrying out Electrical maint work of day to day internal Electric complaint such as rapair / rectification / replacement of defective items like wires, switches, sockets ceiling rose, tube rods, fitting, fixtures etc. by providing skilled electrician at Md Accn of CDA (Army) at Lekhanagar all as specified and directed by Engr-in-Charge.(Store required will be provided seperately).
M&L for servicing, repair and replacement of unserviceable parts, including opening of fan body, cleaning, separating serviceable parts for reuse / refix same after repairing and replacing defecive parts witth new one, reassembling, greasing complete all as specified and directed for Ceiling Fan 1200mm Sweep of any make or model Note: new spares shall be measured and paid seperately. Minor spares and consumables like small screws, washers, grease, cleaning agents, consumables etc. is deemed to be included in the cost
M & L for rewinding from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for Ceiling Fan 1200mm Sweep of any make or model
M & L for Preparing the surface, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint of synthetic enamel white / Brown paint over a coat of red oxide primer, including writing the MES Nos. all as directed for Ceiling Fan 1200mm Sweep of any make or model
--------------------BLANK-----------------
--------------------BLANK-----------------
Supply only Ball bearing made out of high carbon steel, equivalent to the original, 6201/6202/6203/6204/NF-8/6205, suitable for any type, any make, any size fans all as directed. Make: SKF / NBC / FAG .
Supply only GM Bush bearing, equivalent to the original, X-I, X-2, X-3, X-4, suitable for any type, any make, any size, fan all as directed.
S&F in repairs Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs Fan canopy (2 Nos) with screw/check nut, made out of PVC, suitable for c / fans any type, any make, any size all as directed.
S&F, Rubber reel insulator, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs Split pin made out of Nickel plated mild steel with specified temper, suitable for any type c/fan all as directed.
S&F in repairs Bakelite Nichrome connectors, 2 way with fixing screws of suitable size for ceiling fans of any type, any make all as directed.
S&F in repairs PVC condenser holder /rubber condenser holder with PVC connector for ceiling/ Exhaust fans all as directed.
S&F in repairs G I nut bolt 50 mm long 8 mm dia with washers for ceiling fans all as directed.
S&F in repairs G I screw for fixing ceiling fan blades all as directed.
S&F in repairs Armature of ceiling fan duly wound with winding wire incl shaft suitable for any make / size / type ceiling fan all as directed
S&F in repairs Clutch for ceiling fan made out of GI both end threaded suitable for any make / size / type ceiling fan all as directed
Supply only Metal bottom cover with bearing holder suitable for any make / size / type ceiling fan complete with two coats of synthetic enamelled paint white colour all as directed
All as per Srl item No 107 here-in-before but top cover
S&F in repairs Magnetic ring suitable for any make / size / type ceiling fan all as directed
S&F in repairs Fan blades made out of not less than 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour, Set of three, suitable for 1200mm sweep ceiling fans of any type, any make all as directed
K S Enterprises
AIRCOM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .