GE 865 EWS
GE 865 EWS PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT OF DG SETS AT VRIOUS LOCATIONS AND OTHER CONNECTED WORKS UNDER AGE EM I UNDER GE 865 EWS
2024_MES_681153_1
865/EWS(NIT-91)/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
Yes
GE 865 EWS
₹90,000
Yes
21 Dec 2024
25 Oct 2024
16 Nov 2024
25 Oct 2024
14 Nov 2024
8 Nov 2024
Amount
M & L for changing /toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed .
Replacement of Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed
1010 KVA DG Sets
500 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Supply and fixing actuator fuel controller for 1010 KVA DG set complete all as specified and directed
Replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed
1010 KVA DG Sets
500 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Replacement of Fuel filter elements(primary & secondary) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed .
1010 KVA DG Sets
500 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed
1010 KVA DG Sets
500 KVA DG Set
250 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greavescomplete all as specified and directed
1010 KVA DG Sets
750 KVA DG Set
500 KVA DG Set
250 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Repair and replacement of Dynamo Assy for following capacity DG Set complete all as specified and directed
1010 KVA DG Sets
750 KVA DG Set
500 KVA DG Set
250 KVA DG Set
62.5 KVA DG set
35 KVA DG set
S&F replacement of auotmatic voltage regulator(AVR) 24 volt suitable for following capacity of DG Set complete all as specified and directed .
500 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Supply and replacement of self starter for following capacity DG Set Complete all as specified and directed
1010 KVA DG Sets
500 KVA DG Set
200 KVA DG Set
62.50 KVA DG Set
35 KVA DG set
Replacement of Turbo charger assy.for following capacity DG sets complete all as specified and directed
1010 KVA DG Sets
320 KVA DG Set
1200 KVA DG Set
M&L for taking out burnt winding of exciter of following capaicity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed
1010 KVA DG Set
280 KVA DG Set
140 KVA DG Set
100 KVA DG Set
62.5 KVA DG set Note :- For Item Sr. No 14 and 15 here in above -: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed
Supply and Replacement of lub oil pump suitable for following Capacity DG Sets complete all as specified and directed
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Supply and Replacement of thermostate valve suitable for following Capacity DG Sets Complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Supply and Replacement of Oil seal front and rearsuitable side for following Capacity DG Sets complete all as specified and directed
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
Supply and fix in Replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging complete all as specified and directed
Supply and fix in Replacement Battery 12 Volt 85 AH (Maint free heavy duty with initial charging complete all as specified and directed
M &L for Removing the fuel injection pump (FIP) & injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed . Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
35 KVA DG set
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
35 KVA DG set
Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed
Supply and fix in replacement of broken door hinges/handles of acoustic enclosure of 1010 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
Taking down old rusted unserviceable silencer single/double with exhaust pipe and M&L for new silencer with Exhaust pipe complete bends, coupling etc suitable for following capacity of DG set including fixing arrangements and painting with silver paint and insulating with suitable size and length of asbestos rope complete all as specified and directed
1010 KVA DG Set
500 KVA DG Set
140 KVA DG Set
62.5 KVA DG set
Dismantling disconnecting the defected fuel valve of 1010 KVA DG Sets supply and fixing the same complete all as specified and directed
Supply and fixing of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set complete all as specified and directed
Supply and fixing Air cleaner assembly kit for 1010 KVA DG set complete all as specified and directed
Supply and Replacement of battry terminal for DG Sets complete all as specified and directed
Supply and fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete.
Supply & toping up of best quality anti freezing,Inhabitor Corrosion (Coolant ) liquid for DG set at varrious capacity and locations complete all as specified and directed.
M & L for changing /toping up of best quality of engine oil 15W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed .
Supply and fix four pole off load side handle operated change over switch 415V in sheet metal enclosures 4 pole of capacity 1000 Amps complete all as specified and directed
Supply and fix four pole off load side handle operated change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps complete all as specified and directed
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 11KV grade cable for straight through joint for out door type complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size upto 185 sq mm and all as directed
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 11KV grade cable for straight through joint for out door type complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size upto 150 sq mm and all as directed
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 11KV grade cable for straight through joint for out door type complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size upto 95 sq mm and all as directed
Supply and fix cable jointing END TERMINATION JOINT for 11KV grade cable for End termination joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size upto 120 sq mm and all as directed
Supply and fix cable jointing END TERMINATION JOINT for 11KV grade cable for End termination joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3 core aluminium AB cable complete all as specified and as directed.
M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cavble in trenches on plan and n exc 1.5 m in depth in any type of soil and getting out all as specified and directed
M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified.
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified.
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified. Note : Punned thickness of 18 CM will be measured and paid for. Note : Punned thickness of 18 cm will be measured and paid
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, complete all as specified and directed
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 400 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 240 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 35 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Material and labour for PVC trunking system along with clamps, screws, compitable for cable of size 16/25 sqmm 3.5 core complete all as specified and directed.
Material and labour for PVC trunking system along with clamps, screws compitable for cable of size 50/70 sqmm 3.5 core complete all as specified and directed.
Schedule of Credit
M/S BHAT ENGINEERING WORKS (BID ID -3165442)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .