Loading…
Loading…
| # | Company | Quoted % |
|---|---|---|
| 1 | +10.25% | |
| 2 | +4.01% |
Tender Value
₹4.1 Cr
EMD Value
₹2.0 L
Closing Date
5 Jun 2026, 5:00 pmClosed
MR SURAJ KUMAR SEN(DFLT)
CE,DURG
Construction of Proposed Livelihood College Building I/C. Water Supply, Sanitary Fittings, Boundary Wall, approach Road & Electrification Works at Chhuikhadan Distt.- Khairagarh- Chhuikhadan Gandai (C.G.)
190381
NIT No. 183/TC/EinC/PWD/26-27
RESTRICTED TENDER
WORKS
PERCENTAGE
14 days
CE
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR SURAJ KUMAR SEN(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE,DURG
DURG,CIRCLE
DIVISION KHAIRAGARH
120
14
No
0
190381
5 Jun, 2026 5:00:00 PM IST
10 Jun, 2026 10:00:00 AM IST
6 May, 2026 6:00:00 PM IST
NIT No. 183/TC/EinC/PWD/26-27
Construction of Proposed Livelihood College Building I/C. Water Supply, Sanitary Fittings, Boundary Wall, approach Road & Electrification Works at Chhuikhadan Distt.- Khairagarh- Chhuikhadan Gandai (C.G.)
203000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
40598000.00
2
9 Jun, 2026 5:00:00 PM IST
40598000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
6 documents required · 5 mandatory · 1 optional
₹0
₹2.0 L
5 Jun 2026
6 May 2026
10 Jun 2026
6 May 2026
9 Jun 2026
OFFICE OF THE EXECUTIVEENGINEER E/M DIVISION PWD DURG (C.G.)
TERMS & CONDITION
NAME OF WORK :- Construction of Proposed Livelihood College Building I/C. Water Supply, Sanitary Fittings, Boundary Wall, approach Road & Electrification Works at Chhuikhadan Distt.- Khairagarh- Chhuikhadan Gandai (C.G.)
1. Electric installation shall be carried out in accordance with the General Specification for Electrical Works (Part - I Internal) & (Part - II Exlernal) 1972 of C.P.W. D. adopted by E- In-C M.P.W.D. Bhapal & also : Confider With Indian Electrical Rule 1956 as amended. Up to Date.
2. Civil contractor should Subler the Electrical Work only those Electrical contractor who are Registered in PWD for Electrical Work as following class.
(I) "D" Class Electrical Contractor - Up to 1.00 Crore
(II) "C" Class Electrical Contractor - Up to 2.00 Crore
(III) "B" Class Electrical Contractor - Up to 10.00 Crore
(IV)"A" Class Electrical Contractor - Unlimited
3. Contractor will submit along with final bill.
(a) Completion Certificate
(b) Completion Plan drawn to a suitable seale on tracing cloth with ink. Indicating Location of main switch , D.B. Circuit fitting and their location
4. The Contractor will be fully responsibility for any accident damages and losses occurred due to negligence of work. The amount of the losses and damages etc. Will be recovered from the Contractor.
5. The Contractor shall have his own tools and plants, helmet, hand gloves, first aid box and other safety measures. In good working condition for staff No. Extra payment shall be made for this arrangement and no Claims shall be paid by the department.
6. The Contractor himself shall be fully responsibility for any accident casualty of the staff if occurs due to Electrical fault or any other reason during the work and no claim will be paid for such accident of causality by the department.
7. The Contractor will be fully responsibility for taking all of safety measures during contract period.
(a) Electrical power supply arrangement temporarily at site will be made by contractor No payment will the made by PWD Department
(b) Earthing system should be installed in presence of A. E. (e/m)/ Sub Engineer (E&M)
8. Earth Continuity conductor of required size & material should be installed with entire run of wiring Earth nut bolt must be provided at all switch boards All metallic parts Ceiling fan tube fitting socket out let should be essentially connected to earth.
9. All Connection of ceilling fan, tube fixture, street light fixture shall be made by Core PVC/ Rubber sheathed cable of required.
10. The Civil contractor should have a Electrical Supervisor for Electrical works at site as per Norms of C.G./ M.P. Govt. who Electrical Diploma/ Degree Holder as Required as per PAC Amount.
NAME OF WORK :- Construction of Proposed Livelihood College Building I/C. Water Supply, Sanitary Fittings, Boundary Wall, approach Road & Electrification Works at Chhuikhadan Distt.- Khairagarh- Chhuikhadan Gandai (C.G.)
LIST OF APPROVE MATERIALS FOR E/F WORK
S. N. Name of Item Make
1 Flush type Switches/Sockets/Power Plugs 5A / Angle Holder/ Ceiling Roses 3 Plate. 1. M.K.(Elements) 2. Hevell's (Febio) 3. Legrand (Myrious) 4. Schneider (Livia) 5. Anchor (Roma)
2 PVC Wires (Fire Ratardant) 1.5 Sqmm. / 2.5 Sqmm / 4 Sqmm & 6 Sqmm. 1.KEI 2.Polycab 3. Anchor 4.Finolex 5.R R Cable
3 PVC Pipe & its accessories (a) 2 mm Thick for concealed wiring as well as for surface. 1.Plaza, 2.9GREENS 3.BEC plast 4. Polycab
4 MCCB,Pannel ,Main Switches / Change overs Switches 1.Schneider 2.L & T 3.Legrand 4.C& S
5 Power Cable HD 1.Polycab, 2.R R Cable, 3.KEI, 4.Finolex 5.Gloster
6 Ceiling fan 1200 mm / 1400 mm 1.Bajaj 2.Havell's 3.CROMPTON 4.Usha
7 Fresh air Fan/Exahust Fan 1.Bajaj 2.Crompton 3.Usha
8 LED light (luminaries) LED Bulb & LED Street light fitting LED tube light fitting/Tube Rod Bulb 1.Philips, 2.Wipro, 3.Crompton 4.Bajaj
9 Pump 1.SABAR, 2.CRI, 3.Texmo 4.Crompton
Note:- ALL MAKES ARE APPROVED BY S.E. (E/M) CIRCLE OFFICE RAIPUR
NIT Schedule for Construction of Proposed Livelihood College Building I/C. Water Supply, Sanitary Fittings, Boundary Wall, approach Road & Electrification Works at Chhuikhadan Distt.- Khairagarh- Chhuikhadan Gandai (C.G.)
PAC Rs 405.98 Lacs
SERIAL No. Department SOR Year Item Code Description UOM Rate Quantity Amount
1 PWD PWD BLD 2015 1.1.1 Earth Work Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1) In all types of soils. cum 185.000 2898.938 536304.000
2 PWD PWD BLD 2015 1.5 Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. sqm 1.90 5625.000 10688.000
3 PWD PWD BLD 2015 1.6 Extra for every additional lift of 1.5 m or part thereof. 1.6.1) All Types of soil cum 26.500 1042.870 27636.000
4 PWD PWD BLD 2015 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. cum 65.00 938.180 60982.000
5 PWD PWD BLD 2015 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete. cum 371.000 4159.237 1543077.000
6 PWD PWD BLD 2015 1.22 Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. litre 208.00 454.000 94432.000
7 PWD PWD BLD 2015 1.25.1 Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm sqm 27.500 1610.000 44275.000
8 PWD PWD BLD 2015 1.25.2 Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). metre 19.00 220.000 4180.000
9 PWD PWD BLD 2015 1.25.3 Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand). metre 13.50 220.000 2970.000
10 PWD PWD BLD 2015 2.1 Form Work Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. sqm 139.000 2735.118 380181.000
11 PWD PWD BLD 2015 2.1.3 Window sills, anchor blocks, string course, bends, copings, bed plates and like. sqm 184.000 27.000 4968.000
12 PWD PWD BLD 2015 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape sqm 297.000 2375.517 705528.000
13 PWD PWD BLD 2015 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ) sqm 235.000 2701.240 634791.000
14 PWD PWD BLD 2015 2.1.8 Beams, lintels, cantilevers & walls sqm 202.000 2245.750 453642.000
15 PWD PWD BLD 2015 2.1.13 Weather shade, chhajja, Cornices and mouldings sqm 294.000 116.300 34192.000
16 PWD PWD BLD 2015 3.1.3 CEMENT CONCRETE (PLAIN AND REINFORCED) Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.3) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). cum 2970.000 403.575 1198618.000
17 PWD PWD BLD 2015 3.2.1 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.(Note :Excess/ less cement used as per design mix is payable/ recoverable separately) 3.2.1) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). cum 4163.000 1351.234 5625188.000
18 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Ground Floor cum 97.500 393.8747573 38403.000
19 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth First Floor cum 195.000 347.630 67788.000
20 PWD PWD BLD 2015 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth Terrace cum 292.500 13.120 3838.000
21 PWD PWD BLD 2015 3.12.1 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire. all complete: 3.12.1) Thermo-Mechanically treated bars FE 415 kg 54.500 136781.450 7454589.000
22 PWD PWD BLD 2015 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work. cum 4237.00 9.982 42294.000
23 PWD PWD BLD 2015 3.15 Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 93.50 199.642 18667.000
24 PWD PWD BLD 2015 4.3 WATER PROOFING roviding and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of: i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area. iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area. sqm 445.00 175.890 78271.000
25 PWD PWD BLD 2015 7.5.4 Brick Work Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand) cum 3263.000 637.243 2079325.000
26 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Ground Floor cum 121.000 321.953 38956.000
27 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: First Floor cum 242.000 219.050 53010.000
28 PWD PWD BLD 2015 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Terrace cum 363.000 57.840 20996.000
29 PWD PWD BLD 2015 7.11.2 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand) sqm 382.000 1250.280 477607.000
30 PWD PWD BLD 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: sqm 11.000 675.920 7435.000
31 PWD PWD BLD 2015 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:First Floor sqm 22.000 574.360 12636.000
32 PWD PWD BLD 2015 7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. sqm 62.500 1250.280 78143.000
33 PWD PWD BLD 2015 8.3 WOOD AND PVC WORK Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm. each 72.50 384.000 27840.000
34 PWD PWD BLD 2015 8.11.2 Providing and fixing glass panes in glazed or paneled and glazed shutters of doors and window, clearstory windows etc (Only area of glass panes to be measured). 5mm thick sqm 502.000 15.690 7876.000
35 PWD PWD BLD 2015 8.13.1 Providing and fixing flush door shutters, conforming to IS 2202 (Part 1), interior grade, commercial type, core of block board construction with frame of first class hard wood and well matched commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters excluding hinges. 40 mm. thick (single leaf) sqm 1601.00 59.960 95996.000
36 PWD PWD BLD 2015 8.13.2 35 mm. thick (single leaf) sqm 1370.00 56.700 77679.000
37 PWD PWD BLD 2015 8.13.3 30 mm. thick (single leaf) sqm 1197.00 56.700 67870.000
38 PWD PWD BLD 2015 8.15 Extra for double leaf shutter instead of single leaf. sqm 52.000 59.960 3118.000
39 PWD PWD BLD 2015 8.58.1 Providing and fixing bright finished brass butt hinges with brass polished MS screws complete: 125x85x5.50 mm (Heavy Type) each 245.000 300.000 73500.000
40 PWD PWD BLD 2015 8.60.1 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 300x16mm each 475.00 50.000 23750.000
42 PWD PWD BLD 2015 8.62.1 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete: 250x10mm each 276.00 50.000 13800.000
44 PWD PWD BLD 2015 8.65.1 Providing and fixing bright finished brass door handles with brass polished MS screws complete: 125 mm each 55.50 190.000 10545.000
45 PWD PWD BLD 2015 8.76 Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete. each 44.00 100.000 4400.000
46 PWD PWD BLD 2015 8.158 Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete. each 1450.00 22.000 31900.000
47 PWD PWD BLD 2015 9.3.1 STEEL AND ALUMINIUM WORK Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-250 Kg 88.50 9130.770 808073.000
48 PWD PWD BLD 2015 9.4 Extra for curvature in making steel work in tubular structure in built-up sections, trusses and frame work kg 2.30 9130.770 21001.000
49 PWD PWD BLD 2015 9.5 Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part thereof. kg 2.70 9130.770 24653.000
50 PWD PWD BLD 2015 9.6.1 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. Kg 70.00 232.000 16240.000
51 PWD PWD BLD 2015 9.6.2 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Kg 68.00 1321.200 89842.000
52 PWD PWD BLD 2015 9.11 Steel Work Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer. sqm 3330.000 6.120 20380.000
53 PWD PWD BLD 2015 9.13 Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer. kg 75.00 2400.000 180000.000
54 PWD PWD BLD 2015 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer. kg 67.500 3699.900 249743.000
55 PWD PWD BLD 2015 9.16.2 Providing and fixing M.S. frames of doors, windows, ventilators and cupboards joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Angle-iron frames kg 73.50 4580.550 336670.000
56 PWD PWD BLD 2015 9.27.2 Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring. 80x1.20mm M.S. Laths sqm 1570.00 6.120 9608.000
57 PWD PWD BLD 2015 9.28 Providing and fixing 27.5cm long wire spring for rolling shutters. each 362.00 2.000 724.000
58 PWD PWD BLD 2015 9.29.2 Providing and fixing M.S. sheet top cover for rolling shutter 1.20mm thick sqm 530.00 0.720 382.000
59 PWD PWD BLD 2015 9.30 Providing and fixing ball bearing for rolling shutters. each 423.00 1.000 423.000
60 PWD PWD BLD 2015 9.47.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion Kg 331.000 134.065 44376.000
61 PWD PWD BLD 2015 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately). Kg 338.000 792.230 267774.000
62 PWD PWD BLD 2015 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. kg 27.000 478.060 12908.000
63 PWD PWD BLD 2015 9.51.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness sqm 708.000 217.95 154309.000
64 PWD PWD BLD 2015 9.55 Providing and fixing of six/seven levers branded and approved mortise lock. each 594.00 36 21384.000
65 PWD PWD BLD 2015 9.56 Providing and fixing of floor spring IS: marked (Everite, Door link or any equivalent make) with stainless steel cover plate each 1920.00 5 9600.000
66 PWD PWD BLD 2015 10.12 Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. sqm 693.00 686.110 475474.000
67 PWD PWD BLD 2015 11.1.2 Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand) sqm 87.000 3387.260 294692.000
68 PWD PWD BLD 2015 11.2.4 Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 91.500 6614.990 605272.000
69 PWD PWD BLD 2015 11.3.4 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand) sqm 107.000 5268.820 563764.000
70 PWD PWD BLD 2015 11.31.1 Providing and making 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: Flush bands metre 2.10 100.000 210.000
71 PWD PWD BLD 2015 11.31.2 Sunk Bands metre 2.60 100.000 260.000
72 PWD PWD BLD 2015 11.31.3 Raised Band metre 3.00 100.000 300.000
73 PWD PWD BLD 2015 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. sqm 86.000 2805.740 241294.000
74 PWD PWD BLD 2015 12.36.2 Chequered terrazzo tiles 22 mm thick with graded marble chips of size upto 6mm in floors on 25mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including grinding rubbing and polishing complete. Medium shade using approximately. 50% white cement and 50% ordinary cement. sqm 713.000 160.420 114379.000
75 PWD PWD BLD 2015 12.45.1 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) Granite stone grey/pink sqm 1796.000 522.420 938266.000
76 PWD PWD BLD 2015 12.48.2 8 mm thick Table rubbed polished Granite stone tile in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete. Granite stone black sqm 1402.000 40.590 56907.000
77 PWD PWD BLD 2015 12.49 25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm) sqm 897.00 979.830 878908.000
78 PWD PWD BLD 2015 12.65.1 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Plain/ normal coloured precast interlock concrete block sqm 436.00 391.800 170825.000
79 PWD PWD BLD 2015 12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks sqm 632.00 847.160 535405.000
80 PWD PWD BLD 2015 12.74.1 Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 20mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. Size 300x300mm thickness 7 to 8 mm sqm 779.000 229.880 179077.000
81 PWD PWD BLD 2015 12.75.1 Providing and fixing rectified glazed ceramicWall/Dado tiles of 1st quality conforming to IS:15622-2017 of approved make, in all colours, shades overs 12mm thick bed of cement Mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. Size 300x450mm thickness 7 to 8 mm sqm 710.000 528.960 375562.000
82 PWD PWD BLD 2015 12.79.1 Providing and laying DOUBLE/MULTI/CHARGE (minimum 2.0 mm thick Layer) VITRIFIED floor tiles with water absorption less than 0.5% and conforming to IS : 15622 2017 of 1st quality of approed make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.Size 600x600mm thickness 9 to 10 mm sqm 1082.000 1698.160 1837409.000
83 PWD PWD BLD 2015 13.6.2 Marble Work (Wall Lining) 15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.6.2 Granite stone black sqm 3279.000 92.310 302684.000
84 PWD PWD BLD 2015 13.17.2 Providing and fixing 15mm thick Granite (machine cut, table rubbed & mirror polished on both sides) for partition curtain in toilets or similar locations of required size in wall with cement mortar 1:4 (1 cement : 4 coarse sand) including cutting chase in wall and joint with wall treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. Granite stone black sqm 2924.000 208.270 608981.000
85 PWD PWD BLD 2015 13.19.2 Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work metre 172.000 707.4500 121681.000
86 PWD PWD BLD 2015 13.21 Extra for making opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including making necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. each 253.00 23.0000 5819.000
87 PWD PWD BLD 2015 13.24.2 Providing and fixing one side polished 25 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. Both side polished sqm 414.000 71.2800 29510.000
88 PWD PWD BLD 2015 14.54.1 Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete Upto 2mm thickness t make surface even and smooth in line and level sqm 82.000 12192.150 999756.000
89 PWD PWD BLD 2015 14.64 Providing and applying Premium Plastic emulsion paint with roller application Minimum three coats applied @ 0.75 lit/10 sqm up to final finish as per relevant I.S. Code 15489:2013 Type-1 Class D& C ( Glossy and Semi Glossy finish) of required shade ( Product such as Asian Apcolite Premium, Dulux Super Coer, Berger Easy Clean, Nippon Breeze Metex Gold, Opus 1-50I Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work ( with 3 year warranty) sqm 84.000 8758.440 735709.000
90 PWD PWD BLD 2015 14.66 Providing and applying on exterior surface with LITE Economy Exterior Emulsion paint of required shades to give protective and water proof finish minimum three coats applied @ 1.43 lit/10 sqm up to final finish as per relevant IS code 15489:2013 Type-2 class D, C ( Glossy / Semi Glossy finish) (Product such as Asian ACE Spark, Dulux Promise exterior smart, Nerolac Littil Master, Berger Bison Lite, Nippon Superio etc) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work ( With 2 year Warranty. ) sqm 55.000 1607.200 88396.000
91 PWD PWD BLD 2015 14.68 Providing and applying on exterior surface with PREMIUM exterior emulsion paint of required shade to give protective and water proof minimum 3 coats applied @ 1.40 lit./10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Type-2 Class D, C ( Glossy/ Semi Glossy Finish) ( Product such as Asian Apex , Dulux Weather Shield Prima E900, Berger Weathercoat Antidust , Nerolac Everlas Excel, Nippon Sumo Etra, Opus True Flex) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work. ( with 3 year warranty) sqm 84.000 3433.700 288431.000
92 PWD PWD BLD 2015 14.72 Providing and applying Glossy finsh Enamel paint minimum 2 coats in all surface applying @0.75 lit/10 sqm up to required finish as per relevant I.S. Code 2932 :2013 of ( Product such as Asian Apcolite Premium Enamel, Dulux Promise premium Enamel, Nerolac Synthetic Enamel, opus Prime enamel) inclusive of providing abro tape on edges and article and cleaning of doors, windows, floor and surface as required with all tools tackles and labour etc. complete for the work. (With 3 year Warranty) sqm 120.000 805.554 96666.000
93 PWD PWD BLD 2015 14.74 Providing and Applying priming oat on steel work with red oxide/ zinc phosphate primer applied @0.50 lit/Sqm as per relevant code 3536 :1999 (Product such as Asian Zinc phosphate, Dulux Steel primer , Burger Red oxide primer) with all tools tackler and labour etc. Complete for the work sqm 35.000 708.548 24799.000
94 PWD PWD BLD 2015 18.1.3 Sanitary Installations Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Orissa pattern W.C. pan of size 580 x 440 mm each 2899.000 8.000 23192.000
95 PWD PWD BLD 2015 18.4.1 Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type each 2882.000 15.000 43230.000
96 PWD PWD BLD 2015 18.13.1 Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back half stall urinal of size 460x380x250mm each 1776.000 14.000 24864.000
97 PWD PWD BLD 2015 18.15 Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : each 2014.000 9.000 18126.000
98 PWD PWD BLD 2015 18.17.2 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x400 mm each 1408.000 4.000 5632.000
99 PWD PWD BLD 2015 18.17.5 Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Oval or round size 550x400mm. each 1605.000 20.000 32100.000
100 PWD PWD BLD 2015 18.19.1 Providing and fixing vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. White each 1130.000 4.000 4520.000
101 PWD PWD BLD 2015 18.22.2 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of 560x410 mm bowl depth 215 mm. each 6210.000 3.000 18630.000
102 PWD PWD BLD 2015 18.27.1 Providing and fixing cast iron grating for gully trap. 100x100mm square or round each 30.000 59.000 1770.000
103 PWD PWD BLD 2015 18.29 Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. each 599.000 24.000 14376.000
104 PWD PWD BLD 2015 18.76.1 Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1) 75 mm dia pipe. metre 182.000 93.750 17063.000
105 PWD PWD BLD 2015 18.76.2 110 mm dia pipe. metre 267.000 148.5 39650.000
106 PWD PWD BLD 2015 18.77.1.1 Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1) Tee/ Tee with door/ Bend 45°/ Bend 90° 75mm each 113.000 20.000 2260.000
108 PWD PWD BLD 2015 18.77.2.1 Double Y with or without door 75 mm each 129.000 20.000 2580.000
110 PWD PWD BLD 2015 18.77.3.1 Vent covel 75mm each 34.000 10.000 340.000
112 PWD PWD BLD 2015 18.77.4.1 Access door cap 75 mm each 49.500 20.000 990.000
114 PWD PWD BLD 2015 18.77.5 P trap 110mmx110mm long each 227.000 5.000 1135.000
115 PWD PWD BLD 2015 18.77.6 Nahani trap 110x75mm each 90.500 59.000 5340.000
116 PWD PWD BLD 2015 18.77.7 Multi floor trap 110 each 122.00 8.000 976.000
117 PWD PWD BLD 2015 18.77.8 Plain reducing Tee 110x75mm each 129.00 20.000 2580.000
118 PWD PWD BLD 2015 18.78.1 Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm each 57.000 220.000 12540.000
120 PWD PWD BLD 2015 19.5.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 15 mm nominal outer dia .Pipes. metre 133.00 100.0000 13300.000
121 PWD PWD BLD 2015 19.5.2 20 mm nominal outer dia .Pipes. metre 167.00 35.000 5845.000
122 PWD PWD BLD 2015 19.5.3 25 mm nominal outer dia .Pipes. metre 213.00 35.000 7455.000
123 PWD PWD BLD 2015 19.5.4 32 mm nominal outer dia .Pipes. metre 284.00 30.000 8520.000
124 PWD PWD BLD 2015 19.13.1 Water Supply Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (250 grams) each 185.00 50.000 9250.000
125 PWD PWD BLD 2015 19.13.2 Bib cock (350 grams) each 237.00 50.000 11850.000
126 PWD PWD BLD 2015 19.14.1 Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams) each 382.000 40.000 15280.000
127 PWD PWD BLD 2015 19.14.3 Long body bib cock (500 grams) each 426.000 8.000 3408.000
128 PWD PWD BLD 2015 19.14.4 Piller Cock (400 grams) each 398.00 24.000 9552.000
129 PWD PWD BLD 2015 19.14.5 Two way bib cock (800 grams) each 708.000 8.000 5664.000
130 PWD PWD BLD 2015 19.14.6 Stop cock (concealed) (600 grams) each 494.000 20.000 9880.000
131 PWD PWD BLD 2015 19.14.14 Soap dish plate each 163.000 20.000 3260.000
132 PWD PWD BLD 2015 19.14.19 Health foscet (hand jet) with flexible connection pipe (for WC) set 774.00 20.000 15480.000
133 PWD PWD BLD 2015 19.15 Providing and fixing stainless steel drain jali of approved make/quality. each 51.000 16.000 816.000
134 PWD PWD BLD 2015 19.18.1 Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 25 mm nominal bore each 413.000 12.000 4956.000
135 PWD PWD BLD 2015 19.18.2 32 mm nominal bore each 556.000 5.000 2780.000
136 PWD PWD BLD 2015 19.42 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank litre 7.30 6000.000 43800.000
137 PWD PWD BLD 2015 19.47 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : each 754.000 18.000 13572.000
138 PWD PWD BLD 2015 19.49 Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 8013.00 20.000 160260.000
139 PWD PWD BLD 2015 19.52 Constructing masonry Chamber 60x45x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : each 4133.00 10.0000 41330.000
140 PWD PWD BLD 2015 20.1.2 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter metre 262.000 232.0000 60784.000
141 PWD PWD BLD 2015 20.1.3 200 mm diameter metre 506.000 205.0000 103730.000
142 PWD PWD BLD 2015 20.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. pipe metre 436.000 232.0000 101152.000
143 PWD PWD BLD 2015 20.2.3 200 mm diameter S.W. pipe metre 508.000 200.0000 101600.000
144 PWD PWD BLD 2015 20.3.2 Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150x100 mm size P type each 1397.000 4.000 5588.000
145 PWD PWD BLD 2015 20.3.3 180x150 mm size P type each 1504.000 7.000 10528.000
146 PWD PWD BLD 2015 20.28.1 Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line : each 3796.00 4.000 15184.000
147 PWD PWD BLD 2015 21.1.1.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. All types of soil 150 mm dia. metre 339.00 20.000 6780.000
148 PWD PWD BLD 2015 21.1.2.3 Rocky strata including Boulders. 150 mm dia. metre 396.00 70.000 27720.000
149 PWD PWD BLD 2015 21.2.2.3 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders. 150 mm dia. metre 424.000 60.000 25440.000
150 PWD PWD BLD 2015 21.4.3 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia. metre 546.00 25.000 13650.000
151 PWD PWD BLD 2015 21.12.3 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp. each 1055.00 1.000 1055.000
152 PWD PWD BLD 2015 21.13.3 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia each 171.00 1.000 171.000
153 PWD PWD BLD 2015 21.18 Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre) litre 18.500 500.000 9250.000
154 PWD PWD BLD 2015 21.19 Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter. each 644.000 2.000 1288.000
155 PWD PWD BLD 2015 22.1 HORTICULTURE AND LANDSCAPING Trenching in ordinary soil upto a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). cum 115.000 40.000 4600.000
156 PWD PWD BLD 2015 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). cum 201.000 40.000 8040.000
157 PWD PWD BLD 2015 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). cum 236.000 10.000 2360.000
158 PWD PWD BLD 2015 22.5 Rough dressing the trenched ground including breaking clods. Sqm 0.500 200.000 100.000
159 PWD PWD BLD 2015 22.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). cum 17.500 50.000 875.000
160 PWD PWD BLD 2015 22.25.1 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand: Hedges like Alife, Dorenta, Tikoma etc each 14.000 1500.000 21000.000
161 PWD PWD BLD 2015 22.25.2 Furn like Arica, China etc (3 year old) each 125.000 96.000 12000.000
162 PWD PWD BLD 2015 22.25.3 Hibiscus (Flower)/ Rose each 26.500 50.000 1325.000
163 PWD PWD BLD 2015 22.25.4 Carpet grass (well developed) sqm 263.000 200.000 52600.000
164 PWD PWD ROAD 2015 3.12 Construction of embankment with Material Obtained from Borrow Pits/Borrow Area (Construction of embankment with approved material/selected soil having C.B.R.>5 (unless specified otherwise in the contract) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2) cum 223.00 28.600 6378.000
165 PWD PWD ROAD 2015 4.1 A (b)(i) Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, ,carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) For Sub-base cum drainage layer or upper sub-base with Grading-V Material cum 1372.00 57.000 78204.000
166 PWD PWD ROAD 2015 4.13 (B) Construction of Shoulders (Construction of shoulders as per clause 408 with selected soil from borrow pits / borrow areas having CBR not less than 12 and shall have L.L. and P.I. not more than 25% and 6% respectively, inclusive of all leads and lifts, including clearing and scrapping of existing surface, providing required cross fall, compacting. watering rolling and royalty charges etc. complete. With smooth wheeled roller cum 277.00 12.800 3546.000
167 PWD PWD ROAD 2015 6.1 Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.) cum 2332.00 21.200 49438.000
168 PWD PWD ROAD 2015 6.7 Providing and laying un-reinforced Cement Concrete without Dowel bars including formworks and expansion contraction & longitudinal joints as per design and as per IRC-62-2014, over a prepared base a per approved mix design and finishing to lines and grade as per Drawing for Pavement thickness less than 200mm in Low Volume Roads. PCC Grade M30 with minimum Cement Content @375kg/cum cum 4391.00 40.000 175640.000
169 PWD ELECT 2020 1.7 Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)1.7.1 )Short Point Point 266.00 81 21546.00
170 PWD ELECT 2020 1.7.2 Medium Point Point 424.00 255 108120.00
171 PWD ELECT 2020 1.7.3 Long Point Point 588.00 388 228144.00
172 PWD ELECT 2020 1.8 Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 420.00 8 3360.00
173 PWD ELECT 2020 1.9 Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Point 216.00 95 20520.00
174 PWD ELECT 2020 1.10 Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)1.10.2 ) Medium Point Point 659.00 15 9885.00
175 PWD ELECT 2020 1.10.3 Long Point Point 922.00 20 18440.00
176 PWD ELECT 2020 1.10.4 Extra Long Point I Point 1302.00 12 15624.00
177 PWD ELECT 2020 1.10.5 Extra Long Point II Point 1657.00 10 16570.00
178 PWD ELECT 2020 1.10.6 Extra Long Point III Point 1995.00 8 15960.00
179 PWD ELECT 2020 1.11 Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.2 ) Medium Point Point 942.00 8 7536.00
180 PWD ELECT 2020 1.11.3 Long Point Point 1350.00 5 6750.00
181 PWD ELECT 2020 1.11.4 Extra Long Point I Point 1807.00 9 16263.00
182 PWD ELECT 2020 1.11.5 Extra Long Point II Point 2315.00 8 18520.00
183 PWD ELECT 2020 1.11.6 Extra Long Point III Point 2825.00 6 16950.00
184 PWD ELECT 2020 1.12 Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.12.3 ) Long Point Point 1705.00 4 6820.00
185 PWD ELECT 2020 1.12.4 Extra Long Point I Point 2326.00 4 9304.00
186 PWD ELECT 2020 1.12.5 Extra Long Point II Point 3016.00 7 21112.00
187 PWD ELECT 2020 1.12.6 Extra Long Point III Point 3708.00 4 14832.00
188 PWD ELECT 2020 1.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 ) 3 X 1.5 sq. mm in 20mm conduit Metre 92.00 453 41676.00
189 PWD ELECT 2020 1.13.2 3 X 2.5 sq. mm in 20mm conduit Metre 111.00 905 100455.00
190 PWD ELECT 2020 1.13.3 6 X 2.5 sq. mm in 25mm conduit Metre 172.00 255 43860.00
191 PWD ELECT 2020 1.13.4 9 X 2.5 sq. mm in 32mm conduit Metre 238.00 166 39508.00
192 PWD ELECT 2020 1.13.5 12 X 2.5 sq. mm in 32mm conduit Metre 288.00 130 37440.00
193 PWD ELECT 2020 1.13.6 3 X 4 sq. mm in 25mm conduit Metre 145.00 780 113100.00
194 PWD ELECT 2020 1.13.13 6 X 6 sq. mm in 32mm conduit Metre 312.00 87 27144.00
195 PWD ELECT 2020 1.13.14 6 X 10 sq. mm in 40mm conduit Metre 515.00 44 22660.00
196 PWD ELECT 2020 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.1 ) 20 mm Metre 42.00 350 14700.00
198 PWD ELECT 2020 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010)3.11.13 )3 x 2.5 sq. mm Metre 57.00 180 10260.00
199 PWD ELECT 2020 3.12 Supplying and drawing following pair 0.5 mm FR PVC insulated copper conductor, unarmored telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.12.2 )2 Pair Metre 11.00 150 1650.00
200 PWD ELECT 2020 3.14 Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification metre 19.00 446 8474.00
201 PWD ELECT 2020 3.15 Supplying and drawing following pair 0.5 mm FR PVC insulated stranded copper conductor armoured telephone wire in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.15.1 )10 Pair Metre 67.00 70 4690.00
202 PWD ELECT 2020 5.4 Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification.5.4.9 )Fan regulator (two module size) electronic stepped type moving all rounds Each 223.00 130 28990.00
203 PWD ELECT 2020 5.4.11 Plug Top (Deluxe type) 3 pin 16 Amps (For power plug). Each 85.00 16 1360.00
204 PWD ELECT 2020 5.4.13 RJ-45 {CAT6} socket outlet Each 263.00 4 1052.00
205 PWD ELECT 2020 5.4.14 RJ-45 {CAT6} LAN, I/O Box Each 199.00 9 1791.00
206 PWD ELECT 2020 5.4.15 Telephone socket outlet Each 70.00 10 700.00
207 PWD ELECT 2020 5.4.16 T.V. antenna socket outlet Each 74.00 1 74.00
208 PWD ELECT 2020 5.4.19 SP MCB 25 amp Each 250.00 19 4750.00
209 PWD ELECT 2020 5.4.20 Ceiling rose 3 pin 5 amp Each 40.00 450 18000.00
210 PWD ELECT 2020 5.4.22 Batten/ angle holder Each 41.00 66 2706.00
211 PWD ELECT 2020 5.4.23 Blanking plate Each 28.00 250 7000.00
212 PWD ELECT 2020 5.6 Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification. Each 816.00 65 53040.00
213 PWD ELECT 2020 5.7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification.5.7.2 ) Deluxe Each 107.00 6 642.00
214 PWD ELECT 2020 5.10 Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification. Each 109.00 154 16786.00
215 PWD ELECT 2020 6.1 Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3 ) 1200 mm sweep Each 1697.00 134 227398.00
216 PWD ELECT 2020 6.5 Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.2 ) 400 mm sweep Each 2043.00 8 16344.00
217 PWD ELECT 2020 6.6 Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.2 ) 380 mm sweep Each 2858.00 32 91456.00
218 PWD ELECT 2020 6.8 Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.2 ) 300 mm sweep Each 1270.00 2 2540.00
219 PWD ELECT 2020 6.11 Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.2 ) 60 cm long Each 40.00 154 6160.00
220 PWD ELECT 2020 6.15 Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.6 )18/20 Watt Each 868.00 126 109368.00
221 PWD ELECT 2020 6.16 Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.6.16.1) 24 watt, size 300 x 300mm Each 1775.00 40 71000.00
222 PWD ELECT 2020 6.17 Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.5 ) 12 Watt Each 215.00 66 14190.00
223 PWD ELECT 2020 6.18 Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.18.2 )9 watt Each 1148.00 8 9184.00
224 PWD ELECT 2020 6.19 Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 )18/20 watt {4 feet} Each 443.00 251 111193.00
225 PWD ELECT 2020 6.28 Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt.6.28.6 )45 watt Each 2729.00 23 62767.00
227 PWD ELECT 2020 6.48 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as per specification. Each 10.00 122 1220.00
228 PWD ELECT 2020 6.50 Providing and fixing wooden board of suitable size (18''x 24'') for energy meter etc complete as per specification. Each 123.00 1 123.00
229 PWD ELECT 2020 7.2 Supplying and fixing wall mounted metal board of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with 25 mm X 6 mm flat iron as intermediate members including painting etc. as per specification. sqm 2861.00 3.4 9727.40
230 PWD ELECT 2020 7.6 Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip aluminium alloy or wrought aluminium busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification.7.6.2 )100 amps x 450mm long Each 1911.00 4 7644.00
231 PWD ELECT 2020 7.10 Providing and fixing metal clad, TP&N switch fuse unit (re-wirable), 415/500 volts, with porcelain re-wireble fuses including drilling holes on the board, connections, earthing the body etc. as per specification. (Thimbeling shall be paid separately).7.10.2 )63 amps Each 1915.00 15 28725.00
233 PWD ELECT 2020 7.16 Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral).7.16.1 )20x5mm (100 amps) Each 78.00 16 1248.00
236 PWD ELECT 2020 7.19 Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification.7.19.2 )Above 300 mm and upto 450 mm deep sqm 7525.00 5.25 39506.25
237 PWD ELECT 2020 7.20 Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.7.20.2 )200 amp (30x5mm) Metre 907.00 6 5442.00
239 PWD ELECT 2020 9.1 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu.9.1.1 )3 pole MCCB, 25-63A, Fixed Thermal Release, 10KA Each 1483.00 15 22245.00
240 PWD ELECT 2020 9.1.24 4 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 35KA Each 6378.00 2 12756.00
241 PWD ELECT 2020 9.1.27 4 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA Each 13051.00 4 52204.00
242 PWD ELECT 2020 9.1.36 4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA Each 20356.00 1 20356.00
243 PWD ELECT 2020 10.7 Providing and fixing metal clad, 4 pole, on load change over switch unit (with sheet steel enclosure), 415/500 volts, in cubicle panel including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (Connecting lead if required shall be paid separately)10.7.5 )400 amps Each 26442.00 1 26442.00
244 PWD ELECT 2020 10.15 Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.15.3 )200/5 amps Each 347.00 3 1041.00
246 PWD ELECT 2020 10.17 Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification. Each 94.00 9 846.00
247 PWD ELECT 2020 10.18 Providing and fixing penal mounting following rating analog type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.18.4 )0-500 amps Each 458.00 2 916.00
248 PWD ELECT 2020 10.20 Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.20.2 )Digital type Each 835.00 2 1670.00
249 PWD ELECT 2020 10.21 Providing and fixing penal mounting selector switch in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.21.1 )For voltmeter Each 189.00 2 378.00
250 PWD ELECT 2020 10.21.2 For ammeter Each 207.00 2 414.00
251 PWD ELECT 2020 10.22 Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification.10.22.2 )Analoge type Each 2525.00 1 2525.00
252 PWD ELECT 2020 10.23 Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification. Each 1201.00 1 1201.00
253 PWD ELECT 2020 9.4 Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator)9.4.5)6 way Double door Each 2038.00 13 26494.00
254 9.4.4 4 way Double door Each 1716.00 2 3432.00
255 PWD ELECT 2020 9.5 Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)9.5.6)12 way (4 + 36), Double door Each 6820.00 1 6820.00
256 PWD ELECT 2020 9.11 Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.9.11.2)6 amps to 32 amps Each 148.00 312 46176.00
257 PWD ELECT 2020 9.16 Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.9.16.5)63 amps Each 1316.00 13 17108.00
259 PWD ELECT 2020 12.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) Set 3243.00 18 58374.00
260 PWD ELECT 2020 12.4 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification. Metre 77.00 210 16170.00
261 PWD ELECT 2020 12.6 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification. Metre 752.00 24 18048.00
262 PWD ELECT 2020 12.12 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification. Metre 36.00 110 3960.00
263 PWD ELECT 2020 12.19 Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification:12.19.2 )With 2 metre long GI Pipes and 25 kg back filling compound. Each 8222.00 2 16444.00
264 PWD ELECT 2020 12.20 Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres Cum 168.00 4.5 756.00
265 PWD ELECT 2020 14.2 Supplying and laying HDPE pipe of 4kg/Sqcm in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.14.2.1 )63 mm outer dia Metre 124.00 665 82460.00
266 PWD ELECT 2020 14.2.4 110 mm outer dia Metre 355.00 110 39050.00
267 PWD ELECT 2020 14.2.6 160 mm outer dia Metre 664.00 180 119520.00
268 PWD ELECT 2020 14.3 Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.14.3.4 )150 mm internal dia Metre 1183.00 21 24843.00
269 PWD ELECT 2020 14.3.1 50 mm internal dia Metre 333.00 21 6993.00
270 PWD ELECT 2020 15.3 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1).15.3.19 )3.5 x 240 sq. mm. Metre 782.00 150 117300.00
275 PWD ELECT 2020 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. .15.23.20 )3½ X 240 sq. mm (57 mm) Each 504.00 8 4032.00
280 PWD ELECT 2020 19.7 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3)19.7.2 )7 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 700mm long Each 10938.00 10 109380.00
281 PWD ELECT 2020 19.11 Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification.19.11.5 )7 metre high Each 850.00 10 8500.00
282 PWD ELECT 2020 19.12 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification. cum 924.00 4.79 4425.96
283 PWD ELECT 2020 19.9 Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification.19.9.1 )Single Over Hang 0.75 metre Long Each 963.00 8 7704.00
284 PWD ELECT 2020 19.9.5 Double Over Hang 0.75 metre Long Each 1355.00 2 2710.00
285 PWD ELECT 2020 23.3 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant.23.3.4 )3.0 HP, three phase Each 22714.00 1 22714.00
286 PWD ELECT 2020 23.6 Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification.23.6.2 )50 mm outer dia Metre 118.00 150 17700.00
287 PWD ELECT 2020 23.7 Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as per specification.23.7.4 )50 mm dia. Each 1058.00 1 1058.00
288 PWD ELECT 2020 23.8 Supplying and fixing of following sizes GM non return valve ISI mark in the suction/ delivery line etc. as per specification.23.8.4 )50 mm dia. Each 1246.00 1 1246.00
289 PWD ELECT 2020 23.11 Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set Each 4030.00 1 4030.00
290 PWD ELECT 2020 23.12 Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification. Metre 291.00 2 582.00
291 PWD ELECT 2020 23.13 Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification Each 388.00 1 388.00
292 PWD ELECT 2020 23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant.23.14.3 )3x4.0 sqmm Metre 90.00 150 13500.00
293 PWD ELECT 2020 23.15 Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification.23.15.3 )3x4.0 sqmm Each 264.00 1 264.00
294 PWD ELECT 2020 23.16 Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp. Metre 16.00 110 1760.00
295 PWD ELECT 2020 24.20 Supplying of approved make Hiwall split Inverter type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 5 metre of copper piping with insulation etc complete as per specification:24.20.2 )1.5 Ton split type Inverter AC {3 Star} Each 40358.00 8 322864.00
296 PWD ELECT 2020 24.4 Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis) Each 2110.00 8 16880.00
297 PWD ELECT 2020 24.10 Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification24.10.1 )5/8 " Metre 375.00 40 15000.00
300 PWD ELECT 2020 24.11 Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification Set 435.00 8 3480.00
301 PWD ELECT 2020 24.12 Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification Metre 14.00 80 1120.00
302 PWD ELECT 2020 26.17.5 CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve 8222.00 Each 2 16444.00
303 PWD ELECT 2020 27.11 Supplying , installation , testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night Support, UL ,CE FCC Certified as per the specifications. Each 6353.00 12 76236.00
304 PWD ELECT 2020 27.19 Supplying , installation , testing and commissioning of 16 Channel NVR 2 Sata port Up to 16 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 2 SATA HDDs up to 6 TB each, 2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 4/2 , Two way talk 1 Channel Input, 1 Channel Output RCA , 1 RJ-45 port (10/100/1000Mbps) as per the specifications. Each 12252.00 1 12252.00
305 PWD ELECT 2020 27.25 Supplying , installation , testing and commissioning of 4 Port POE Switch 10/100 4 Port PoE with 2 10/100 Mbps Uplink ,Power Budget 60 Watt , Max 30 watt per port as per the specifications. Each 2773.00 1 2773.00
306 PWD ELECT 2020 27.37 Supplying , installation , testing and commissioning of 4 TB Surveillance Hard disk drive Complete as required Each 9565.00 2 19130.00
307 PWD ELECT 2020 27.44 Supplying , installation , testing and commissioning of 4U Indoor Rack Wallmount 4U 400D With Front Glass Door Lock & Key 550 4U - (fan; cable manager; PDU) complete as required. Each 3132.00 1 3132.00
308 PWD ELECT 2020 27.49 Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 27.49.2)43 inch Each 43178.00 1 43178.00
309 PWD ELECT 2020 24.23 Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 24.23.2 )60/120 Ltrs/hr Each 34581.00 2 69162.00
310 PWD ELECT 2020 24.24 Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification. 24.24.1 )25 Ltrs/hr output capacity Each 23508.00 2 47016.00
311 PWD ELECT 2020 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. cum 168.00 48.88 8211.84
Say In Rs 405.98 Lacs
Sub Engineer S.D.O. P.W.D. Sub Division Chhuikhadan Executive Engineer P.W.D. Division Khairagarh
Department Name Code SOR Name SOR UOM Name UOM Code false6329
Bastar Urban Public Transport Society (BSTUPTS) BSTUPTS ELECTRIC ELECT Percentage %
Bilaspur Urban Public Transport Society (BSPUPTS) BSPUPTS NON SOR NS Per mile %O
Chhattisgarh Department of Agriculture (CGDA) CGDA BRIDGE PWD_BRIDGE 1000 no. 1000 no.
Chhattisgarh Handicraft Board (CGHCB) CGHCB PWD BUILDLING PWD BLD 1000No. 1000No.
Chhattisgarh High Court, Bilaspur (CGHC) CGHC PWD ROAD PWD ROAD Siemens Per meter A/V
Chhattisgarh Housing Board (CGHB) CGHB Acre ACR
Chhattisgarh Infotech Promotion Society (CHiPS) CHiPS Activity unit AU
Chhattisgarh Medical Services Corporation Ltd. (CGMSC) CGMSC Bag BAG
Chhattisgarh Police Housing Corporation Ltd (CGPHC) CGPHC Book BK
Chhattisgarh Rajya Beej Evam Krishi Vikas Nigam (CGRBEKVN) CGRBEKVN Box BOX
Chhattisgarh State Civil Supplies Corp. Limited (SCSC) SCSC Gallons per hour (US) BPH
Chhattisgarh State Industrial Development Corporation (CSIDC) CSIDC Bottle BT
Chhattisgarh State Mandi Board (CGSMB) CGSMB Cubic sentimeter /second C3S
Chhattisgarh State Minor Forest Produce(Trading & Developme) Co-Operative Federation Ltd (CGMFPFED) CGMFPFED Canister CAN
Chhattisgarh State Power Distribution Company Limited (CGSPDCL) CGSPDCL Carton CAR
Chhattisgarh State Power Generation Company Limited (CGSPGCL) CGSPGCL Cubic Centimeter CCM
Chhattisgarh State Power Transmission Company Limited (CGSPTCL) CGSPTCL Cubic decimeter CD3
Chhattisgarh State Warehousing Corporation (CGSWC) CGSWC Centiliter CL
Chhattisgarh Text Book Corporation (CGTBC) CGTBC cm cm
Department of Animal Husbandry and Dairy (DAHD) DAHD Centimeter CM
Department of Home Guard and Civil Defence Chhattisgarh (HGCD) HGCD Square centimeter CM2
Department of Panchayat and Social Welfare (DPSW) DPSW Crate CRT
Department of School Education (DSE) DSE Case CS
Department of Technical Education (DTE) DTE Cu.Mtr. Cu.Mtr.
Directorate of Fisheries (DF) DF cum cum
Durg-Bhilai Urban Public Transport Society (DBUPTS) DBUPTS cum.km cum.km
Food and Drug Administration (FDA) FDA Days DAY
Health Department (HD) HD Degree DEG
Indira Gandhi Krishi Vishwavidyalaya (IGKV) IGKV DFLT DFLT
Korba Urban Public Transport Society (KRBAUPTS) KRBAUPTS Decimeter DM
Koriya Urban Public Transport Society (KRYAUPTS) KRYAUPTS Drum DR
Mineral Resources Department (MRD) MRD Dozen DZ
Naya Raipur Development Authority (NRDA) NRDA EACH EA
Panchayat and Rural Development (PARD) PARD each each
Public Health Engineering Department (PHED) PHED each additional floor each additional floor
Public Works Department (PWD) PWD each cut each cut
Raigarh Urban Public Transport Society (RIGUPTS) RIGUPTS each test each test
Raipur Collectorate (RC) RC each tree guard each tree guard
Raipur Development Authority (RDA) RDA each tree guard each tree guard
Raipur Urban Public Transport Society (RUPTS) RUPTS Enzyme Units / Milliliter EML
Rajnandgaon Urban Public Transport Society (RNDGUPTS) RNDGUPTS Enzyme Units EU
Rural Engineering Services (RES) RES Fluid Ounce US FOZ
Sarguja Urban Public Transport Society (SUPTS) SUPTS Feet FT
State Urban Development Agency (SUDA) SUDA Square foot FT2
Urban Administration and Development Department (UADD) UADD Cubic foot FT3
Water Resources Department (WRD) WRD Gigajoule FY
gram act.ingrd /liter G/L
Gram act.ingrd. GI
Gram /liter GLI
Gram /square meter GM2
Gram/Cubic meter GM3
Gallons per mile (US) GPM
hectare hectare
Joule /kilogram JKG
Kilogram act.ingrd KAI
Kilogram /cubic decimeter KD3
Kilogram/Mol KGM
Kilogram /Second KGS
Kilogram / cubic meter KGV
kg act.ingrd /kg KIK
Kilojoule/kilogram KJK
Kilojoule/Mol KJM
Square kilometer KM2
Kilometer/hour KMH
Kelvin/Minute KMN
Kelvin /Second KMS
Kilonewton per square meter KNM
Kilovoltampere KVA
Liter per 100 km LHK
Liter /Minute LMI
Liter /Molsecond LMS
Liter Per hour LPH
1/square meter M-2
Mol per cubic meter M:M
Megawatt hours M..
Meter /Hour M/H
Mol per liter M/L
Meter /second M/S
Square meter M2
Square meter/Coat M2C
Square meter/second M2S
Cubic meter /Hour M3H
Cubic meter/second M3S
Milligram/liter MGL
Milligram /cubic meter MGQ
Square mile MI2
Microsecond MIS
Milliliter act.ingr. MLI
Square millimeter MM2
Cubic millimeter MM3
Millinewton/meter MNM
Miles per gallon (UG) MPG
Millimol per liter MPL
Millipascal seconds MPS
Meter/second squared MS2
Microsiemens per centimeter MSC
Newton/meter NM
Newton/Square millimeter NMM
one RCC jaali tree guard one RCC jaali tree guard
one RCC jaali tree guard one RCC jaali tree guard
P.cumt. P.cumt.
P.Point P.Point
p.sq.mtr p.sq.mtr
P/sq.Mt. P/sq.Mt.
Pascal second PAS
Megavoltampere PCT
per cm height per letter per cm height per letter
per cm height per letter per cm height per letter
per cubic centimeter per cubic centimeter
Per Km. Per Km.
per letter per letter
Per mtr Per mtr
per pouch per pouch
per test per test
per tonne per tonne
per tonne capacity per tonne capacity
per.mtr per.mtr
Parts per billion PPB
Parts per million PPM
Parts per trillion PPT
Number of persons PRS
Pound Per Sq inch PSI
Pint, US liquid PT
Per Ton Per KM PTPK
Quart, US liquid QT
quintal quintal
Gramm/cubic centimeter RHO
RUNNING METRE RMT
Thousand Hours THR
Ton/Cubic meter TOM
DEFAULT UNIT DESCRIPTION XXX
Square Yard YD2
Microgram /liter µGL
Microgram /cubic meter µGQ
boq_comp_chart.xls
BOQ Comparative Chart • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
4608597139656204709_190381_Form A.docx
NIT • 0.07 MB
5724354954069436063_190381_NIT.docx
NIT • 0.12 MB
6058417772021054330_190381_Notice.docx
NIT • 0.04 MB
4245647720152213378_190381_ANNEXURE-E.xlsx
BOQ • 0.01 MB
8854042723854726175_190381_APPROVED MATERIAL.xlsx
BOQ • 0.01 MB
8399667647409323211_190381_BOQ.xlsx
BOQ • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .