| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-Finance 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | L1 | Accepted-Finance Bidder is L1. Recommended for award of contract and approved by the competent authority. | |
| 2 | Rejected-Technical AT JAWAHAR NAGAR PO BERMO DIST BOKARO PIN 829104 JHARKHAND | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Bidder is technically rejected. | |
| 3 | Rejected-Technical | - | Rejected-Technical Bidder is technically rejected. |
Tender Value
₹3.4 L
EMD Value
₹4,300
Closing Date
27 Dec 2024, 9:00 amClosed
PE(ENM)
PO OFFICE,BOKARO COLLIERY
Repair and maintenance of three (03) nos. 3.3KV grade Neutral Grounding Resistor including monitoring fail safe relay and its proper earthing at Gandhinagar substation and DD Mines substation under Bokaro Colliery (BnK)
2024_CCL_323455_3
CCL/BnK/Bokaro/EnM /24-25/7
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
BOKARO COLLIERY
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,300
25 Jan 2025
16 Dec 2024
28 Dec 2024
17 Dec 2024
27 Dec 2024
17 Dec 2024
17 Dec 2024 - 23 Dec 2024
Amount
Cleaning and Servicing of NGR Components including Resistors, Terminals and Insulators
Replacement of Damaged/ burnt Resistor Elements as per sample
Replacement of complete resistor element of resistance value of 190.5 ohms
Replacement of Damaged/ leaky Insulators of suitable grade as per sample
Replacement of Corroded or Damaged Connecting Cables and Terminals
Replacement of damaged Current Transformer
Repainting and Corrosion Protection by application of anti-corrosive paint on NGR Housing and Structure
Replacement of HRC Fuse base as per sample
Replacement of locking arrangement of monitoring panel
Replacement of damaged visible fibre glass and supply and fitting of missing nut bolts
Supply of ferrules, wire and lugs for connection of control circuit
Repairing of alarm circuit of monitoring panel/ fail safe relay
Supply, erection, installation of chemical earth pit including minimum 3 metres long electrode with 25 kg BFC Bag and providing masonry enclosure with cover plate having locking arrangement
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Testing and Commissioning of NGR after Post-Maintenance Testing and Functional Checks
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .