| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.6 L+₹68,585 (3.44%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹21.5 L+₹1.6 L (8.00%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹22.5 L+₹2.6 L (13.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹23.5 L+₹3.6 L (18.2%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Sept 2021, 6:00 pmClosed
GE Chandimandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-41/2021-2022 REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION WITH FITTING AND FIXTURE IN MD ACCN OF SEC A AND PINE MARG AT CHANDIMANDIR
2021_MES_456078_2
GE/CHM-41/2021-2022
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer
₹80,000
Yes
28 Oct 2021
24 Aug 2021
21 Sept 2021
24 Aug 2021
14 Sept 2021
31 Aug 2021
Amount
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in for sunken wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 02 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account.
All as per serial item 06 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 06 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 06 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Supply and fixing for electric Bell, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge.
Supply & Fixing for ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Supply and fixing for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed.
Supply & fixing switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Supply & fixing switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
Supply & fixing socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed.
Supply & fixing socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
Supply and Fixing modular type fan regulator, single pole, 230 volt two module, flush on the existing laminated sheet as directed.
Supply & fixing Bell push modular type, single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Supply and fixing for bulk head fitting in engineering plastic housing with clear prismatic diffuser 6 watt capacity complet all as specified and directed.
Supply and fixing indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaries' (LED batten shall be prewired box type, retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage not more than 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glare free, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sq mm". Make C&S Cat No LTDC01220WLED/WD or equivalent makes in HAVELLS, PHILIPS, BAJAJ Note- LED tubelights of metal body should be fixed with PVC cover of proper size.
Supply and fixing indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaries' (LED batten shall be prewired box type, retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage not more than 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glare free, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sq mm". Make C&S Cat No LTTB2F10WLED/W or equivalent makes in HAVELLS, PHILIPS, BAJAJ Note- LED tubelights of metal body should be fixed with PVC cover of proper size.
Supply and fixing for surface mounted LED down light in engineering plastic housing with clear prismatic diffuser with LED Lamp 9 watt white light complete all as specified and directed (Make :- C&S Cat part No:-CG80B9WLED or equivalent in HAVELLS , BAJAJ, SURYA, PHILIPS
Supply and fixing for decorative wall light fitting high grade poly carbonate housing suitable for and including 15 watt LED retofit lamp, PC diffuser in opal finish glass filled engineering plastic B22 lamp holder with electrical grade copper contact wired upto terminal block, mounting bracket with lugs and screws complete all as specified and direcated.Make:- Havells produt No. CITY-1 LHDL 02160099 or Dor equivalent in HAVELLS / BAJAJ/SURYA /HPL
Disconnecting and taking down carefully opper/aluminium sub main wiring complete, including existing batten/surface conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified.
Supply and fixing for sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 20mm size(minimum size) complete all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core of 4 sqmm cable shall be considered as 1 running metre.(ii) Conduit & conduit accessories shall be measured & paid for separately (iii) Color code shall be Red for phase, black for neutral and green for earth
Supply and fixing for sub main wiring with four core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC conduit 20mm size(minimum size) complete all as specified and directed. Note : (i) For the purpose of measurement, 4 single core of 10 sqmm and one single core of 10 sqmm cable shall be considered as 1 running metre.(ii) Conduit & conduit accessories shall be measured & paid for separately (iii) Color code shall be Red for phase, black for neutral and green for earth.
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and remving from site, all as specified and directed by Engr-in charge.
Supply and fixing for TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100to 125Amps & outgoing 4 way having IP 54 protection complete all as directed by Engineer-in-charge. Make :- Havells /ABB/INDOASIAN/LEGRAND
Supply and fixing MCCB, 125 Amps, four pole,3 phase ,36KA, 415 volt with adjustable thermal and maganetic release complete all as specified and directed by Engineer-in- Charge. (Make:- Cat Part No IHA13EBF0125 of Havell's or equivalent Make :- Havells /ABB/ INDOASIAN/LEGRAND
Supply and fixing MCCB, 100 Amps, four pole,3 phase ,36KA, 415 volt with adjustable thermal and maganetic release complete all as specified and directed by Engineer-in- Charge. (Make:- Cat Part No IHA13EBF100 of Havell's or equivalent Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply and fixing sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 12 way double door with 200 Amps rated copper bus bar and blank plate as required complete all as directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & Fixing for sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way double door with 200 Amps rated copper bus bar and blank plate as required complete all as directed by Engineer-in-charge.Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply and fixing sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 2 way double door without bus bar complete all as directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & Fixing for MCB ,DP , 240 volt, 16Amps to 32Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & Fixing for MCB ,DP , 240 volt, 40 to 63 Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :-Havells Cat No NDHMGCDP0F40 or equivalent make as specified in Appx 'C'
Supply & Fixing for MCB ,FP , 240 volt, 63Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & Fixing for MCB ,SP , 240 volt, 6Amps to 63Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & Fixing for MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engineer-in-charge. Make :- Havells /ABB/ INDOASIAN/ LEGRAND
Supply & fixing of 20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified & directed by Engineer-in-charge.
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Supply and fix in repair 230 volt 4/5 watt LED candle lamp with big threaded holder complete all as specified & directed by Engineer-in-charge. Make:-Starlite,Halonix, bajaj
Supply and fix in repair 230 volt 4/5 watt LED candle lamp with small threaded holder complete all as specified & directed by Engineer-in-charge.ake:-Starlite,Halonix, bajaj
Supply and fix in repair Indication room light (bell type 4 to 8) Nos (as per sample) controlled by (4 to 8) bell switches complete all as specified and directed.
Supply and fix in repair LED bed side fitting flexible type 3 watt as per sample complete all as specified and directed.Make Cat part -philips 48042 3- warm white LED or equivalent in bajaj , Polycab, havells
Supply and fix in repair LED round recess polycarbonate housing downlight with integrated driver down light 6 Watt warm white all as specified and directed. (Make :- C&S Cat part No:-LTCR6HPLEDRNDW DOWNLIGHT/warm white or equivalent in HAVELLS , BAJAJ, SURYA, PHILPS
Supply and fix in repair LED round recess polycarbonate housing downlight with integrated driver down light 6 Watt white all as specified and directed. (Make :- C&S Cat part No:-LTCR6HPLEDRNDW DOWNLIGHT or equivalent in HAVELLS , BAJAJ, SURYA, PHILPS
Material and labour for fabrication, installation, testing and commission of wall mounted sheet metal busbar chamber CPRI approved factorymade, grouted with nut & bolts size 600x500x300 mm with aluminium strip 40x6mm (04 Nos) of length 450mm with approved colour code and PVC adhesive coated, IP-54 as per IS-13947 protection fixed on insulator with the help of nut/ bolts including provision of 10 Nos 08 mm dia hole with 8 mm dia 50 mm long nut/ bolts with 02 Nos of washer connected with 16sqmm single core colour coding stranded copper cable with thimble/ lugs including provision of MCCB, 125 Amps, four pole,3 phase ,25 KA, 415 volt with adjustable thermal and maganetic release complete and making good disturbed surfaces to match with the original all as specified and directed by Engineer-in- Charge. Make of MCCB :- Cat Part No IHLASDCF0125 of Havell's or equivalent make as specified in Appx 'C'
Supply and fix in repair LED recess mounted square down lighter 6W LED white complete all as specified and directed Make:-C & S Cat part No:-LTCRSLM6HPLEDSQ/W or equvalent in HAVELLS , BAJAJ, SURYA, PHILPS
Supply & fix casing capping with fixing accessories of size 20mm width complete all as specified and directed .
Supply and fixing for casing capping with fixing accessories of size 25mm width complete all as specified and directed .
Horizon Construction Company
Vasudeva Trading Co.
SINGARI ELECTRICAL WORKS
R N Enterprises
aggarwal traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .