Tender Value
₹15.8 L
EMD Value
₹31,600
Closing Date
2 Dec 2023, 6:00 pmClosed
GE(AF) B/R CHAKERI
GE(AF) B/R CHAKERI -208008
REPLACEMENT OF TOWER SPLIT ACs IN OT ICU HDU EXHAUST FAN IN BLDG NO P-7 HARJINDER BILLET TOILET SNCO MESS LIGHTENING PROTECTION SYSTEM AT GUARD ROOM AT 7 AFH KANPUR CANTT
2023_MES_625949_1
GE(AF) BR/CHK/T-38 OF 2023-24 8889/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
7 AFH Kanpur Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(AF) /R CHAKERI
₹31,600
Yes
9 Jan 2024
31 Oct 2023
9 Dec 2023
31 Oct 2023
2 Dec 2023
14 Nov 2023
Amount
M&L for point wiring with PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch/socket, brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for fan point controlled by one, one way switch complete all as specified and directed.
S & F switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified
S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
Supply and fixing Exhaust fan AC single phase 230/240V of size 450 mm in sweep , metallic body complete with all accessories including connection by using three core flexible wire of size 0.50 sqmm and making holes and cutting, grouting nut bolts in wall for exhaust fan all as specified and as directed.
Supply and fixing Exhaust fan AC single phase 230/240V of size 300mm in sweep, metallic body complete with all accessories including making connection by using three core flexible wire of size 0.50 sqmm and making holes, grouting nut bolts in wall for exhaust fan all as specified and as directed
Material and labour for lightening protection system 107 meter radius, maximum height of the lighting protection not less than 5 mtr made of aluminium and outer surface coated with SS and streamer emission 60m incl suitable strip complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6.0mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below grounded level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B-1 reinforced with 6mm dia MS bars @ 150mm c/c RCC cover slab 40mm thick with two no’s fitting handle,, GI Pipe 20mm dia light grade with funnel & wire mesh for watering and 50mm dia light grade GI Pipe for earth strip protection etc earthing result not more than 2 ohm complete all as specifiedd and directed
S & F 32x6mm GI strip as Earth continuty conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any indicated situation for loop earthing etc as required
M&L GI Pipe light grade with all fitting laid in trenches and under road/floor/walls etc of size 50mm bore including making disturbed surface good to match with the existing.
Supply, installation and testing of 3 phase vertical tower Air conditioning 4.0 TR capacity complete indoor and outdoor unit with cooling capacity of 54000 BTU/Hours along with dust filter anti-corrosive blue fin copper condenser, hydrophillic blue evaporator fins, powder coated outer body, auto/manual mode operation including memory function with heavy duty 3 phase scroll type compressor withn the Eco friendly R410a refrigerant which has low noise level, PVC copper wire of 3 core 4 sqmm to be used to indoor unit to outer door unit along with the foundation and fixing bracket for outer unit and repairing the disturbed surface complete all as specified and directed. Make:- Blue star/Voltas/Carrier/Hitachi
Supply and fix Voltage stabilizer of capacity 6 KVA for automatic operation, three phase naturally air cooled indoor type with copper winding & designed for input variation between 360 V to 440 V with output voltage stabilized at 415 V with accuracy of ± 2.5% complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor unit complete with cordless remote control unit and with in built air ioniser and testing and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 TR complete including out door mounting bracket complete all as specified and directed.
Supply and fix Voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type type with copper winding & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed.
S&F copper pipe along with PVC cushion o size 5/8" dia all as specified and directed.
All as per item No-14 but of size 1" dia
M&L for sub main wiring with three runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and PVC casing N Capping with all necessary fittings and accessories and 02xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 4 Sqmm as continuous neutral and earth wire (black and green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly complete all as specified and directed. (Note. Three run of cable and one run of PVC casing and capping and 01 run of neutral & 01 run of earth continuity wire shall be measured as one unit )
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn in and incl PVC conduit concealed with all necessary fittings and accessories and 01xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 4 Sqmm as continuous and earth wire (green in colour ) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly all as specified and directed. (Note. Two run of cable and one run of PVC conduit concealled and one run of earth continuity wire shall be measured as one unit)
S & F VTPN distribution board doule door 4 ways with the provision of MCCB as incomer and wintrip MCB as outgoing with IP-43 protection, with suitable lugs for incomer, cable glands and bottom lugs for outgoing distribution system complete all as specified and directed.
S&F MCCB, 415 Volts, 200 Amps, 36 KA, 4 pole complete all as specified and directed.
S&F MCB TP upto 40 Amp ,'C' series, 415 Volt complete all as specified and directed.
S & F triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB of capacity 32 Amps 'C' series all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B-1 reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering etc. and 15 mm dia GI pipe for protection of earth lead complete all as specified and directed by Engr-in-Charge.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one Single pole MCB of capacity 32 Amps 'C' series all as specified and directed.
Supply and fixing XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 95 sq mm, 3.5 core , laid in trenches/ducts /encased in GI pipe /fixed to pole /OH conductor all as specified and directed.
Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5m in depth for laying of UG Cable including getting out in soft/loose soil complete all as specified & directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point complete all as specified and directed.
M&L for spreading & leveling dry clean Ganga sand in trenches for cushioning UG cable complete all as specified and directed.
M&L for sub class 'B' old size of Brick in trenches for cable protection of LT Cables complete all as specified and directed.
santosh electronics
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .