| 1 | L1₹43.8 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹48.3 L+₹2.0 L (4.29%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹48.9 L+₹2.6 L (5.72%)Rejected-Finance ROWRIAH CHARIALI JORHAT ASSAM PIN 785004 | JORHAT | JORHAT | ASSAM | 785004 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
REPAIR MAINT OF HT SUPPLY DISTRIBUTION SYS WITH CONNECTED ACCESSORIES AT JORHAT MIL STN UNDER GE JORHAT
2022_MES_526983_2
84084E8
Open Tender
Civil Works
Item Rate
240 days
GE JORHAT
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE JORHAT
₹80,000
Yes
22 Aug 2022
20 Jun 2022
25 Jul 2022
20 Jun 2022
23 Jul 2022
27 Jun 2022
21 Jun 2022 - 25 Jun 2022
Amount
M & L Calibratiion, testing, servicing and commissioning of 11 KV VCB and removing of breaker from existig HT panel and servicing to include cleaning, greasing, carbon removing with CRC/Jelly,Busbar cleaning,removing of sulphonification at Teminals/ busbars and checking the CT,PT working condition,fixing of insulated materials for Busbar and carried out calibration fro desired values (TMS,earth relay timing etc),complete testing and commissioning of 11 KV breaker capacity (As per existing Make / Model) (400 to 800 amp) for 11 KV VCB with panel Installed at different locations for proper functioning of the Installations complete all as specified and directed. Note:- :i)Servicing eqpt, moisture removing tools (Heating),cleaning tools,Insulated mtrl, for Busbars,Testing tools shall be deemed in quoted rates. ii)Testing report will be submitted to Engr incharge after servicing.
All as per Item No 1, but 33/11 KV SF6 Circuit Breaker.
All as per Item No 1, but 33/11 KV MOCB Circuit Breaker.
M&L for 4 Sqmm x 4 core copper conductor control cable for connection with CTs & PTs and transformer (Bucholz Relay) with their respective panel for better and effective protection of installations complete as per existing size & type with connecting accessories complete all as specified and directed.
M&L for 6 Sqmm x 6 core copper conductor control cable for connection with CTs & PTs and transformer (Bucholz Relay) with their respective panel for better and effective protection of installations complete as per existing size & type with connecting accessories complete all as specified and directed.
Dismantling HT/LT insulators any type, any size by diconnecting all electrical connections complete all as specified and as directed.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
S & F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green, two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts after taking proper electric shut down from Engg in Charge and restored electric supply after completion of each job and maintaining their record complete all as specified and directed.
Dismantling cross-arms of mild steel channel or angle sections etc. complete and setting aside by diconnecting all electrical connections for re-use or removing to store or for schedule of credit all as directed by Engr-in-Charge
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Dismantling ACSR or AAC conductors from HT OH lines/structures and removing to store or taken on schedule of credit complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
M & L for stay assembly of stay rod of diameter 20 mm complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and as directed.
M & L for Loop type insulator, large size, with overall dimensions 140 mm X 85 mm, cable hole dia 25 mm, creepage distance 57 mm, minimum failing load 88000 N, vitreous porcelain, white, brown or green, Designation C as per IS 5300: 1969 complete all as specified and as directed.
M & L for hot dip galvanized stay strands of grade I, 7 Nos wires construction, wire diameter 4 mm, nominal strand diameter 12 mm, heavy zinc coating complete all as specified and as directed.
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 11 kV, rated voltage 12 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 28 kV (rms) (ii) across the isolating distance 32 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 75 kV (Peak) (ii) across the isolating distance 85 kV (Peak), Rated short-time withstand current 25 kA for 3 seconds, rated peak withstand current 63 kA for climatic conditions at the site, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
M&L for HT drop out expulsion fuse unit suitable for 100 Amps Capacity at 11 KV ,single pole (two post insulators per pole) with HT barrel fuse with holder including necessary connection to ACSR conductor of suitable size after taking down the old unserviceable drop out switches complete all as specified and as directed.
M&L for Two coats of Aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces by spray painting external surfaces of steel tubular poles (HT/LT)/GI pipes /Panels at various Sub stations with approved colour code complete all as specified and as directed. Note:Colour code of eqpt/substation VCBs /Panels area for painting at shall got approved by GE
Supply ,laying, jointing, commissioning & testing HT UG cable of size 95 Sqmm 3 core, 11000 volts (earthed), aluminium conductor, XLPE insulated, earthed, screened, PVC bedded, armoured heavy duty electric cable conforming to IS-7098 (Part -II) 1985 with latest amendments drawn through pipe or laid in trenches, fixed on poles etc. including taking out the old unserviceable ones and stored as and where directed complete all as specified and as directed.
Supply ,laying, jointing, commissioning & testing HT 11 KV arial bunched cable of size 95 Sqmm 3 core + 80 Sqmm supporting conductor of capacity , 11000 volts aluminium conductor, XLPE insulated, heavy duty electric cable conforming to IS-7098 (Part -II) 1985, IS: 8130-1984,IS: 398 (Part-IV) - 1979, IEC- 60502 (Part-II) 2005 with latest amendments , fixed on poles with MS hooks including taking out the old unserviceable ones and stored as and where directed complete all as specified and as directed.
M&L for fixing and connection of lightening arresters set ( Set of 03 nos), non linear 12 KV, metal oxide type, distribution class 5 KA rupturing capacity for outdoor use with conforming to IS : 15086 PT- I of 2001, complete and suitable for 11KV supply system including taking down the old unserviceable ones complete all as specified and as directed.
Supply, jointing and testing HT heat shrinkable jointing kit straight through type for 11000 Volt grade 3 core XLPE insulated Earthed cable outdoor type complete with jointing material and accessories of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable ones complete all as specified and directed.
Supply, jointing and testing HT cable end jointing kit for 11000 Volt grade cable cold shrinkable indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable (Earthed) of size 95 Sqmm including taking down old unserviceable jointing kit complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supply and erection of lightning arrestor (set of three), explusion type suitable for 11 kV continuous operating voltage (3 phase) with rated voltage 24 kV (rms) with nominal discharge capacity of 65 kA and complete with galvanised clamping arrangements, GI bolts, nuts, washers etc. complete as specified and as directed. Note- Lightning attester shall be able to withstand wind load of 196Kg/Sqm and seismic acceleration of 0.39g.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & laying unreinforced precast concrete cable cover class HV type 1, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for boring /drilling by machines/manual horizontally under the road in any type of soil without cutting /disturbing the existing road and inserting GI pipe of any size for drawing the cable. complete all as specified & as directed.(GI Pipe shall be measured and paid separately).
M&L for cutting the road/ hard standing to a size not exceeding 30 cm in width not exceeding 75 cm in depth for laying/ removal of HT/ LT UG cable or cable protection pipe of any size including making good the disturbed surfaces by using PCC(1:4:8) type D2 (using 40 mm graded aggregates) for 100 mm thick on top including fair finishing complete all as specified and directed.
Supplying & laying in trenches 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing aluminium strip 25 mm X 3 mm for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.
M&L for preparation of old painted steel or iron external surfaces of transformer of capacity 1000-2000 KVA by scrapping with coir/ steel wire brush/scrapper emery paper, etc. and applying one coat of synthetic enamel paint of colour as approved by Eng in Charge by using spray machine including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed. [Note: Necessary shut down of power supply should be granted from the Engr-in-Charge by the contractor before proceeding the work, also electric supply should be restored as early as possible after completion of the work]
M&L for painting works on surfaces of items as given below of 33 KV MRS at Lichubari comprising of following equipment/machinery fitted at yard by preparation of steel and iron of old painted surfaces smooth and applying one coat of synthetic enamel paint of existing colour and writing MES No, Name and capacity on plants of font size as ordered complete all as specified & directed by Engr-in-Charge. (i) HT Poles (Steel) for structures 11 meters long-12 no's (ii) Aluminium paint of Cross Arms/Channels of Approx Area 45 Sqm. (iii) Cement base weather proof painting of RCC (single) poles-06 no's.(iv) Scraping/ cleaning the surfaces of capacitor bank's panel and applying one coat of synthetic enamel painting - Qty -03 nos. (v) Weather proof painting on platform of Power Transformer, Earth Pit & Platform of Capacitor bank of the yard/MRS approx -43 Sqm.
Disconnecting and takingout,repairing existing APFC HT 11 KV VCBs for seviceable & reuse (One No-150 KVAR & Two No-75 KVAR ) (Make : Areva) from housing and cleaning,rubbing and overhauling the mechanical parts and making serviceable of local/remote electrical operation of the panel including Greasing,oiling,replacement of UNSV Trip coil,breaker charging motor,gear pinion,roller switch and reassembling the same after replacement as required including testing (IR Test,Continuity Test,Tripping Test of earth fault and over current of panel) complete all as specified and directed (Note :All Spares parts of VCBs panel will be Measured and paid sepratly under respective items of this schedule here in after as supply only)
M & L of 4 pole/2 pole structure of 11 KV Gang operated devices Servicing, greezing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for gang operations handle (medium garde,appx lenght 06 mtr) including clamps etc complete all as specified and directed.
M & L of 33 KV isolator/GODs Servicing, greasing,tightning of connections of conductors/HT cables,nut bolt etc,insluators(pin/disc) checking and cleaning the surfaces with CRC,aligniment of tripole gang with existing pins,jumpering,replacement of GI pipe for Isolator operations handle including clamps etc complete all as specified and directed. Note : Spare parts such as moving arm,operating pipe GI 32 mm,insulator base, MS channel 75x40x5 mm,fixed contact -copper flat (voltage 33 KV) shall be including in item quoted rate
Supply and fixing in replacement of the following spares for 11 Kv VCB (400 Amp-800 Amp) during servicing/overhaulingas per existing type and make at any location/installation under Jorhat stn complete all as specified and directed .
ISOLATING CONTACT - FLAT TYPE
VACUMM INTERRUPTER up to 650 Amps
VACUMM INTERRUPTER up to capacity 800 Amps
VCB Operating Mechanism (Mention Coil & Motor voltage) 650 to 800 Amp VCB
VCB Operating Mechanism (Mention Coil & Motor voltage) 400 to 650 Amp VCB
Closing Coil
Trip Coil
Spring Charging Motor
Breaker Auxiliary Switch
Motor Cut-off Switch
Ratchet Wheel
Pin For Ratchet
Closing Coil Box Assembly
Trip Coil Box Assembly
Motor Cut Off Lever Assy
Charging Pawl
Buffer For Spring
Over Ride Stop
Over Ride Stop Pin
24 Pin Plug & Socket Assembly
Rack -In /Rack -Out Handle
Spring Charging Handle
Limit Switch Assembly
MI com digital relay as per existing Model/ make on VCBs
Material and labour painting of existing RCC cable route indicators ( both civil and mil area)with synthetic enamilled two coats of brown in colour and write with white colour letters for indication of joint/ area etc ,incl minor repairs with rendering,grouting at site complete all as specified and directed.
Dismantling of HT/LT connection at site from earthing lead carefully defective Transformer of capacity of 25 KVA to 315 KVA, 11 KV/440Volt, opening the top cover of the transformer at site, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) including necessary replacement of spares/ components complete all as specified and directed. (NOTE: Spares/ components required to be replaced shall be measured and paid as supply only under relevant items of this schedule.)
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 25 to 75 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as specified and directed
Disconnection of HT/LT connection, earthing lead and taking down carefully defective Transformer of capacity of 100 to 300 KVA, 11 KV/440Volt from 2/4 pole structure/Platform including transportation to factory/workshop including loading/ unloading and draining out existing transformer oil, opening the top cover of the transformer, by removing nut, bolts, washer etc and lifting the core and winding by using triploid and chain pulley after removing LT/HT spindle with bushing and cleaning the yoke and winding/core and spindle bushing the same winding/core and spindle bushing and replace the worn out nut, bolts, washer gaskets etc with provision of cork sheets of 6mm thick (best quality) and filling the transformer oil which was removed earlier, through stream line filter after dehydration and back to site after necessary repair & lifting of Transformer to its original position including necessary testing complete all as specified and directed
M&L for preparation of old painted steel or iron surfaces of transformer of 100 KVA to 300 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No etc. all as directed with black synthetic enamel paint on white background complete all as specified and directed.( Necessary shut down of power supply be obtained from Engr- in -Charge before the work and supply shall be restored immediately on completion of work.
M&L for preparation of old painted steel or iron surfaces of transformer of 25 KVA to 75 KVA capacity by scrapping with steel wire brush/ emery paper etc and applying one coat of synthetic enamel paint smoke grey colour using spray painting machine complete including writing of SM No. , MES No etc. all as directed with black synthetic enamel paint on white background complete all as specified and directed.( Necessary shut down of power supply be obtained from Engr- in -Charge before the work and supply shall be restored immediately on completion of work.
Supply only LT bush insulator as per existing size , shape and make for 100 to 300 KVA capacity transformer.
Supply only LT bush insulator as per existing size , shape and make for 25 to75 KVA capacity transformer.
Supply only LT brass/copper stud as per existing size , shape and make for 100 to 300 KVA capacity transformer.
Supply only LT brass/copper stud as per existing size , shape and make for 25 to 75 KVA capacity transformer.
Supply only gasket ( Set of four) for LT bushing as per existing size and shape for 100 to 300KVA capacity transformer.
Supply only gasket ( Set of four) for LT bushing as per existing size and shape for 25 to 75KVA capacity transformer.
Supply only top cover cork gasket set as per existing size and shape for 100 to 300 KVA capacity transformer.
Supply only top cover cork gasket set as per existing size and shape for 25 to 75 KVA capacity transformer.
Supply only HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 25 to 75 KVA capacity transformer.
Supply only HV bushing with brass terminal with nuts and washers and sheet gasket as per existing size and shape for 100 to 300 KVA capacity transformer.
Supply only breather assembly including silica gel of required quantity for 11/0.433 KV transformer for 100 to 300 KVA capacity .
Supply only breather assembly including silica gel of required quantity for 33/11 KV transformer of any capacity .
Supply only breather assembly including silica gel of required quantity for 11/0.433 KV transformer for 25 to 75 KVA capacity .
Supply, filling and topping up new transformer oil conforming to IS-335 of 1993 for filling/ topping up oil of transformer up to desired level complete all as directed. ( Dielectric strength of oil shall not be less than 40KV ) Make: GULF/POWER OIL or equivalent as approved by GE.
Dehydration and filtration of existing transformer oil of transformer at different location in site with filtration machine and heating system to get Di-electric strength of oil 40KV/cm minimum without disturbing the power supply system complete all as specified and as directed.
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of HT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for HT coil of 33/11 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 11/0.433 KV transformer complete all as specified and directed.
M/L rewinding of LT coils of transformer of any capacity using proper size copper DPC wire having class 'F' insulation as per existing size and turns including connected minor insulation materials suitable for LT coil of 33/11 KV transformer complete all as specified and directed.
M/L for cleaning of conservator oil tank of capacity 25 to 300 KVA transformers including refixing of rubber cork gasket as per existing size complete all as specified and directed.
Supply only 33 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 50 Amps and following IS, complete all as specified and directed.
Supply only 33 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 30 Amps and following IS, complete all as specified and directed.
Supply only 33 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 20 Amps and following IS, complete all as specified and directed.
Supply only 11 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 30 Amps , complete all as specified and directed.
Supply only 11 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 20 Amps , complete all as specified and directed.
Supply only 11 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 15 Amps , complete all as specified and directed.
Supply only 11 KV of copper tinned metal, having Capacity Tag on every fuse with rated HT fuses barrel type of capacity- 10 Amps , complete all as specified and directed.
M & L for calibration testing and commissioning Master relay (Digital type) of 11 KV VCBs suitable to existing make/model including the hire charges of testing kit and tools as required on site complete all as specified and directed.
M & L for calibration testing and commissioning Under voltage relay (Digital type) of 11 KV VCBs suitable to existing make/model including the hire charges of testing kit and tools as required on site complete all as specified and directed.
Supply, installation, commissioning,and testing of Battery monitoring system for continueous monitoring and checking each Battery bank, with having microcontroller based software,along with necessary copper conductor control cables for desired length including dismantling old unsv existing sytem complete all as specified and directed.Make: chloride Model number A1 (up to 12 cells)/ eqivalent HBL/orion(AGV systems pvt. Ltd)
HEMONTA DAS
KAY CEE CO. INDIA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .