Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹34.5 L+₹5.6 L (19.3%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹35.3 L+₹6.4 L (22.1%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹38.0 L+₹9.1 L (31.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹39.4 L+₹10.5 L (36.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
COMPREHENSIVE REPAIR/ REPLACEMENT OF LT ELECTRIC DISTRIBUTION LINES PANES AND ALLIED WORKS AT CENTRAL AREA, SARVATRA VIHAR, ENGINE HOUSE ROAD ETC UNDER AGE E/M I OF GE(CENTRAL) KIRKEE
2023_MES_583805_1
CWE/KKE/TOKEN-84 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KIRKEE
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹96,000
Yes
17 Apr 2023
2 Mar 2023
27 Mar 2023
2 Mar 2023
23 Mar 2023
17 Mar 2023
3 Mar 2023 - 9 Mar 2023
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in soft/ loose soil.
All as per item No. 1 above but in soft/disintegrated rock complete all as specified
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
M & L fo PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M&L for sand dust for cusioning of UG cable/ at cable trenches inside substation bulding etc.
M&L for PCC cable cover , class LV type 1 flat size 250 mm x 150mm x 40 mm with ISI mark factory made , complete all as specified and directed by Engr-in-Charge.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
M & L for replacement for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty XLPE U/G Cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs all as specified and directed.
All as per item No. 10 here-in-before but 10sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 2 core complete all as specified
All as per item No. 10 here-in-before but 10sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 25sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 35sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 70sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 120sqmm 3.5 core complete all as specified
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and keeping aside for refixing or carrying to store for credit
M&L for steel tubular swaged pole in replacement of complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long).
Dismantling and taking down old/unsv cross arms, bracing, supports etc complete for reuse at site or carrying to store for sch of credit all as specified and directed.
M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed
M&L ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dercted
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed.
M&L pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed..
M&L shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
M&L Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.
M&L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one all as specified and directed. (Clamps, loop insulator, earth work, PCC measured separately)
M&L for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one all as specified and directed
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard
S&F earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire
Supply and Installation of Earthing Rods as per following Specifications 1 Earthing Rod Pipe in Pipe Design Outer Pipe in GI and having minimum diameter of 76mm. 3m in length Inner pipe to have minimum diameter of 32mm Both ends properly welded to make them air tight GI Terminal size of 100X50X6mm with 2 nos M8 holes for Termination. Area in between 2 pipes filled with Dry type chemical powder having high conductivity Dry type Chemical powder filled under high pressure to ensure no air pockets are left. Electrode must be tested for Short Circuit Test of minimum 40kA at CPRI / NABL 2 BFC Compound. The BFC is carbide based having very high electrical conductivity.
The Earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5m The Bore drilling will be done with the help of Pneumatic boring machine. SOKG BFC will be placed in the bore to cover the Earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. Eaxh Pit Cover Square300X300X240mm to be provded to cover the Earth Pit. the Earth pit Cover shall be made of Reinforced FRP and shouId be capable of carrying the weight of 5 tons
M&L for restraining of existing/in replacement of overhead ACSR conductor of any size of 4 wire 35-45 mtr span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed .
M&L for restraining of existing/in replacement of ACSR conductor of any size of 2 wire 35-45 mtr span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
M&L for restraining of existing/in replacement of GI Cradle guard hexagonal/rectangular of any size 35-45 mtr span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed
M&L for restraining of existing/in replacement of GI earth wire of any size 35-45 mtr span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of HT over head line of span up to 50 meters including removing of creepers etc fron poles
Cutting/Trimming of tree branches arround 3.00 mtr distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles
S & F sheet steel enclosure in replacement of size 40cmx30cmx40cm made out of 3mm thick MS sheet hinged door and locking arrangements and painting (inside and outside) with epoxy powder coated including fixing in position with the following accessories internally pre wired and testing complete all as directed. (a) GIC J648B1, 240V, AC, base mounting, L & T - 01 No. (b) 3 pole power contactors, type ML-3 of L&T or equivalent – 01 No. (c) Toggle switch, single pole 2 way - 01 No. (d) bakelite base brass terminal connector block 8 way 40 amps cap-1 No, (e) MCB TPN 40 amps of Legrand/L&T-1No and fixed to pole/wall with clamp, nuts, bolts washers and testing complete incl dismentling taking down unserviceable switch fuse complete all as specified and directed.
M&L Heat shrink end joint in replacement indoor/outdoor LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKT0003 or equivelent of M-Seal/3M
M&L Heat shrink end joint in replacement indoor/outdoor LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0019 or equivelent of M-Seal/3M
M&L Heat shrink end joint in replacement indoor/outdoor LT 1100 volts grade 70-150 sqmm, 3.5core, make-Raychem, Cat No-EPKT0035 or equivelent of M-Seal/3M
M&LHeat shrink end joint in replacement indoor/outdoor LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKT0051 or equivelent of M-Seal/3M
M&L Heat shrink straight through joint in replacement out door type LT 1100 volts grade 10-16 sqmm, 4 core, make-Raychem, Cat No-EPKJ0123 or equivelent of M-Seal/3M
M&L Heat shrink straight through joint in replacement outdoor type LT 1100 volts grade 25-50 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0130 or equivelent of M-Seal/3M
M&L Heat shrink straight through joint in replacement outdoor type LT 1100 volts grade 70-150 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0137 or equivelent of M-Seal/3M
M&L Heat shrink straight through joint in replacement outdoor type LT 1100 volts grade 185-300 sqmm, 3.5 core, make-Raychem, Cat No-EPKJ0144 or equivelent of M-Seal/3M
Painting of existing steel pole any type up to 7.5 meter height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation all as directed by Engr-In-Charge
Numbering of LT poles serially with letter/number size width and height up to 40 mm in site with white paint on black back ground
M&L GI tubing light grade 40mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection including taking out old pipes all as specified and directed.
M&L GI tubing light grade 50mm bore on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection, ISI marked, for cable protection including taking out old pipes all as specified and directed.
M&L GI tubing light grade 80mm bore,on pole /wall with necessary clamps,nuts,bolts and washers/under road cross ISI marked, for cable protection ISI marked, for cable protection including taking out old pipes all as specified and directed.
M&L for jumper connections of length up to 1.50 mtr with guage of ACSR, binding with existing conductors for LT OH lines complete as directed by the Engr-In-Charge.
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 1100 volts, 25 x 20 cm size including taking out defective danger boards all as specified and directed.
M & L for Danger notice plate of 1.6mm thick MS sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 11000 volts, 25 x 20 cm size including taking out old danger boards all as specified and directed.
Supply and errect Cast Iron LT cable route indicator round shaped 120 mm dia 8 mm thick duly embossed with MES LT Cable fixed on flat iron 25X3 mm thick 300 mm long and grouted in PCC (PCC measured separately)
M & L for rigid PVC line spacer, U-shaped, spiral type, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast
M & L for rigid PVC line spacer, U-shaped, spiral type, suitable for 4 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast
M & L for aluminium cable lugs of size 50 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints)
M & L for aluminium cable lugs suitable for XLPE cable size 70 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for aluminium cable lugs suitable for XLPE cable size 95 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for aluminium cable lugs suitable for XLPE cable size 120 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for aluminium cable lugs suitable for XLPE cable size 150 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for aluminium cable lugs suitable for XLPE cable size 240 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for aluminium cable lugs suitable for XLPE cable size 300 sqmm flat head in Aluminium conductor/cable fixing with Nuts, bolts & washers to junction point as directed, (Note-To be measured only, fixed at places other than with heat shrink joints).
M & L for MCCB, 3 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 400 amps, incl dismentling taking down unsv one, make- Legrand or equivalent.
M & L for MCCB, 3 pole, 25 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismentling taking down unsv one,
M & L for MCCB, 4 pole, 25 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismentling taking down unsv one,
M & L for MCCB, 4 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 25 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 10 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 10 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 100 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 10 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 63 amps, incl dismentling taking down unsv one,
M & L for MCCB, 3 pole, 10 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 40 amps, incl dismentling taking down unsv one,
M & L for 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm and overall PVC sheathed in service connections from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
Ditto all as per item No 79 but size of cable 6 sqmm
Ditto all as per item No 79 but size of cable 4 sqmm
Labour for disconnecting LT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectificaion LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge enerator pluse, ECHO fault locaor with high frequency distance calculator etc. The entire reepair work to be completed with in 6 hours of instruction from Engr-in-Charge as specified. NOTE :- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs has to be rectified within 6 hours after notification, failing to which Rs 500/- per day complain will be recovered. fault locating with electronic fault locator, excavation and earth work disconnecting and reconnecting both ends of cable, relaying of sand and protective cable covers are deemed to be inclucded in the quoted rate all as specified and directed by Engr-in-Charge. Join it will be measured separately in appropriate item in this schedule.
Note: (i) The colour of panel board shall be smoke gray (ii) The panel board shall be errected after taking out old unserviceable one. (iii) Disconnection of all cables from old panel board and reconnection of all cables to new panel board shall be done and rate shall be inclusive of the quoted rate. (iv) Panel shall be CPRI type tested. Location : CAFVD ME Line/RA Line/ Stn HQ/512 ABW
Note: (i) The colour of panel board shall be smoke gray (ii) The panel board shall be errected after taking out old unserviceable one. (iii) Disconnection of all cables from old panel board and reconnection of all cables to new panel board shall be done and rate shall be inclusive of the quoted rate. (iv) Panel shall be CPRI type tested. Location : CAFVD Offier Mess/KKD Line/ Sarvatra Vihar/MW Line
S & F outdoor Distribution panel box CPRI type tested of size 750 mm (L) x 400 mm (B) x 1500 mm (H) fabricated from 3.00 mm thick CRCA sheet with hinged door front & Rear for each cabinet, powder coated by smoke gray after anti-rust treatment of CRCA sheet. Top and bottom cabinet should consist of 3 phase and neutral aluminium bus bar of capacity 200 Amps with 2 NOs of earth terminal door lock for front and rear door with additional mounting stand should be made from ISA 50x6mm and 500mm long leg duly embossed on front and rear opening. One MCCB of capacity 200 Amps four pole should be provided between incoming and outgoing Bus Bar as mentioned above. Note: (i) The FPB shall be errected after taking out old unserviceable one. (ii) Disconnection of all cables from old FPB and reconnection of all cables to new FPB shall be done and rate shall be inclusive of the quoted rate. (iii) Panel shall be CPRI type tested and to be fabricated in ISO certified panel manufacturing factory - Panel Make- Success Engineers, Bhosari / ABB/L&T Location : MW Line/Sarvatra Vihar/ADG/RSAMI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .