Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SUBHAM ENTERPRISES L1 | HARI SINGH AND COMPANY L2 |
|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' SECTION-I (BUILDINGS/STRUCTURE WORKS) | |||||
| 2.00 | Construction of block of ‘GUARD ROOM WITH TOILET and Elevated Sentry Post (D/S)’ complete all as specified and shown on drawings. | 1 | Each Block | 18,35,000 ₹18.4 L | 20,50,000 ₹20.5 L |
| 3.00 | Construction of block of ‘GUARD ROOM WITH TOILET (S/S)’ complete all as specified and shown on drawings. | 1 | Each Block | 18,35,000 ₹18.4 L | 18,00,000 ₹18 L |
| 4.00 | Construction of Sentry Post (S/S)’ complete all as specified and shown on drawings. | 1 | Each Block | 1,00,000 ₹1 L | 50,000 ₹50,000 |
| 5.00 | Construction of block of ‘LUBRICATING OIL and GREASE STORE SHED (S/S)’ complete all as specified and shown on drawings. | 1 | Each Block | 19,00,000 ₹19 L | 19,75,000 ₹19.8 L |
| 6.00 | Construction of block of ‘TECHNICAL ANCILLARY SHOP (S/S)’ complete all as specified and shown on drawings. | 1 | Each Block | 38,00,000 ₹38 L | 40,00,000 ₹40 L |
| 6.01Subtotal {Total of Schedule 'A' Section-I } | |||||
| 7.00SCHEDULE ‘A’ SECTION-II (PART-I) (INTERNAL WATER SUPPLY WORKS) | |||||
| 8.00 | Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II (Part-I). | 1 | Unit | 18,000 ₹18,000 | 1,35,000 ₹1.4 L |
| 9.00SCHEDULE ‘A’ SECTION-II (PART-II) (INTERNAL WATER SUPPLY WORKS) | |||||
Updated dates
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
14 Mar 2026, 6:00 pmClosed
Col Shery Goel
HQ CWE Bikaner Bikaner Military Station
Provn of 2 x Guard Rooms with Sentry Post, Grease Storage Shed and Technical Ancillary Shops at Bikaner Mil Stn under GE (N) Bikaner
2026_MES_749009_1
CA No CWE BKN-Token No 91/2025-2026
Open Tender
Civil Works
270 days
Bikaner
Please refer tender documents
7 documents required · 7 mandatory
₹1,000
GE (N) Bikaner
₹1.9 L
Yes
24 Mar 2026
17 Jan 2026
21 Mar 2026
17 Jan 2026
14 Mar 2026
28 Feb 2026
17 Jan 2026 - 31 Jan 2026
SCHEDULE 'A' SECTION-I (BUILDINGS/STRUCTURE WORKS)
Construction of block of ‘GUARD ROOM WITH TOILET and Elevated Sentry Post (D/S)’ complete all as specified and shown on drawings.
Construction of block of ‘GUARD ROOM WITH TOILET (S/S)’ complete all as specified and shown on drawings.
Construction of Sentry Post (S/S)’ complete all as specified and shown on drawings.
Construction of block of ‘LUBRICATING OIL and GREASE STORE SHED (S/S)’ complete all as specified and shown on drawings.
Construction of block of ‘TECHNICAL ANCILLARY SHOP (S/S)’ complete all as specified and shown on drawings.
Subtotal {Total of Schedule 'A' Section-I }
SCHEDULE ‘A’ SECTION-II (PART-I) (INTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Section-II (Part-I).
SCHEDULE ‘A’ SECTION-II (PART-II) (INTERNAL WATER SUPPLY WORKS)
Supply & fixing 15mm bore Angle stop valve, fancy type with long shank and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F wall mixer, telephonic type, brass, chromium plated, fancy type, with capstan head handles with lettered 'hot' and 'cold', screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, complete all as specified as directed. Make : Cat Part No. ‘G4916A1’ of ‘Parryware’ / Cat Part No. ‘F2002401’ of ‘Cera’ / Cat Part No. ‘CQT-23281UPR’ of ‘Jaquar’ / Cat Part No. ‘9275’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, complete all as specified as directed. Make : Cat Part No. ‘G4914A1’ of ‘Parryware’ / Cat Part No. ‘F2002461’ of ‘Cera’ / Cat Part No. ‘CQT-23167B’ of ‘Jaquar’ / Cat Part No. ‘9250’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
Supply & fixing stainless steel Peg Set of Six of standard size (not less than 300mm long) fixed to wall with two rawl plugs and chromium plated brass screws complete all as specified & as directed. Make :- Cat Part No BEA-30 of make – Prayag or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
Supply & fixing spray jet, brass chromium plated with and including 1.5 metre long PVC flexible reinforced pipe for EWC for 15mm bore pipe complete all as specified & as directed.
Subtotal {Total of Schedule 'A' Section-II (Part-II)}
SCHEDULE ‘A’ SECTION-III (PART-I) (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for “Internal Electrification Works” as listed in Schedule ‘A’ Section-III (Part-I).
SCHEDULE ‘A’ SECTION-III (PART-II) (INTERNAL ELECTRIFICATION WORKS)
All as per serial item No. 20.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
All as per serial item No. 20.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 20.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed.
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix 'B'
Supply and fixing LED Bulb 0.50 W (in different colour) complete all as specified & as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, system luminous efficacy of minimum 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a on site replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing wall mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
Supply and fixing MCB, 40 to 100 Amps, Single Pole & Neutral, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volts, 16 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply and fixing MCCB, 4 Pole, 125 Amps, rupturing capacity 25 KA, 415 Volt grade, AC, 50 Hz, fixed Thermal - Magnetic, complete all as specified and as directed.
Supply and fixing industrial wall mounted plug socket suitable for IP-44 degree of protection enclosure with a two pin and earth plug and socket, complete all as specified and as directed.
Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1 Sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed.
Material and labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the test point / cross arms earth lead upto 7.5 meter length from top of earth plate) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, Pit cover & frame including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part-I. Notes :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earth lead upto 7.5 meter length from top of earth plate.
Supply, fixing and testing of LED flood light 100 watt, 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete with time delay relay complete all as specifief and as directed.
Subtotal {Total of Schedule 'A' Section-III (Part-II)}
SCHEDULE 'A' SECTION-IV (ROAD/PATH WORKS)
Lump sum price worked out by the Contractor for “Road/ Path Works” as listed in Schedule ‘A’ Section-IV
SCHEDULE 'A' SECTION-V Part-I (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Section-V, Part-I.
SCHEDULE 'A' SECTION-V, Part-II (SEWAGE DISPOSAL WORKS)
Material & labour for DWCPE (SN8) pipe confirming to IS-16098, 150mm nominal bore (160mm outer dia), laid to slope in trenches, jointed and tested including necessary jointing material complete all as specified and as directed.
Subtotal {Total of Schedule 'A' Section-V (Part-II)}
SCHEDULE 'A' SECTION-VI (AREA DRAINAGE WORKS)
Lump sum price worked out by the Contractor for “Area Drainage Works” as listed in Schedule ‘A’ Section-VI
SCHEDULE 'A' SECTION-VII (FENCING AND GATE WORKS)
Lump sum price worked out by the Contractor for “Fencing and Gate Works” as listed in Schedule ‘A’ Section-VII
SCHEDULE 'A' SECTION-VIII, Part-I (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for “External Water Supply Works” as listed in Schedule ‘A’ Section-VIII (Part-I).
SCHEDULE 'A' SECTION-VIII, Part-II (EXTERNAL WATER SUPPLY WORKS)
M&L for tapping of 40mm water supply line connection from existing 150/100mm bore DI line including socket/Clamp/Tee including jointing complete all as specified and as directed.
Subtotal {Total of Schedule 'A' Section-VIII (Part-II)}
SCHEDULE 'A' SECTION-IX, Part-I (EXTERNAL ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for “External Electric Supply Works” as listed in Schedule ‘A’ Section-IX (Part-I).
SCHEDULE 'A' SECTION-IX , Part-II (EXTERNAL ELECTRIC SUPPLY WORKS)
Supply & fixing HDPE DWC pipe of outer dia 120mm and inner dia 103 mm for laying of LT cable laid in trenches complete all as specified and as directed. Note : Necessary earthwork shall be measured and paid seperately under respective item.
Supply and fixing bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to ploe with & including mild steel clamps (02 Nos) made of flat iron 40x3mm with nuts, bolts & washers, complete all as specified and as directed.
Supply and Fixing Light Emitting Diode (LED) based Flood light fitting, 200 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 110/120 lumens per watt, a minimum system lumen output of not less than 22000 lumens, Correlated Colour Temperature (CCT) shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 300 V, AC, frequency 50-60Hz, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 10%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed.
Supply & fixing juction box of size (300x200x105mm made out of polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66 with integrated membranes/metric knockouts for cable entry with cable glands, protection and suitable size of "connectwell" stud terminal (provision for socket bolting) 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 Amps-01 No and mounted on tubular/PCC pole with suitable clamps, nuts, bolts,complete all as specified and as directed. Note: CA No shall be embossed on each box by digital printing mechanism. complete all as specified and as directed.
Supply & fixing automatic street light switch using infrared sensor based Nature switch, 25 KW equally distributed, 63 amps, 3 pole, model: swadeep-02 EC 25 kw3p for automatic switching of street light based on LUX leval of natural light the sensor (nature switch) alongwith suitable power contector rating 63 amps, 3 pole & 40 amps 2 pole, MCB SP 63 amps-03 Nos and support terminals shall be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box confirming to IP-54, the contector suitable to 3 phase load of 25 kw, rating 63 amps, 3 pole, MCB rating 63 amps SP 3 Nos complete all as specified and as directed.
Supply & fixing HDPE DWC pipe of outer dia 63mm and inner dia 51 mm for laying of cable laid in trenches complete all as specified and as directed. Note : Necessary earthwork shall be measured and paid seperately under respective item.
Subtotal {Total of Schedule 'A' Section-IX (Part-II)}
SCHEDULE 'A' SECTION-X (HOT WATER SUPPLY AND COOLING APPLIANCES WORKS)
Lump sum price worked out by the Contractor for “HOT WATER SUPPLY AND COOLING APPLIANCES WORKS” as listed in Schedule ‘A’ Section-X
SCHEDULE 'A' SECTION-XI (EXCAVATION AND EARTH WORK)
Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-XI.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tender91.pdf
Tender Documents • 2.25 MB
Prepriced91.pdf
Additional Documents • 0.35 MB
BOQ_838809.xls
BOQ • 0.29 MB
GDROOM1.pdf
Additional Documents • 16.83 MB
BTD_DRG_1.rar
Additional Documents • 4.11 MB
BTD_DRG_2.rar
Additional Documents • 25.00 MB
GDROOM3.pdf
Additional Documents • 15.77 MB
GDROOM4.pdf
Additional Documents • 10.21 MB
GDROOM2.pdf
Additional Documents • 19.24 MB
Download all tender documents and submit your bid