Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.0 L+₹1.1 L (2.26%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹50.1 L+₹2.1 L (4.37%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹50.9 L+₹3.0 L (6.18%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹51.1 L+₹3.1 L (6.56%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
25 Aug 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
SPECIAL REPAIRS TO CERTAIN BUILDINGS AT TB-I MEG PROVISION OF CERTAIN SANCTIONED WORK AT VARIOUS LOCATION UNDER AOR UNDER GE N BNG
2022_MES_542969_1
8324
Open Tender
Civil Works
Item Rate
270 days
BNG
Class D category a(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹88,000
Yes
23 Sept 2022
3 Aug 2022
27 Aug 2022
3 Aug 2022
25 Aug 2022
19 Aug 2022
3 Aug 2022 - 18 Aug 2022
Amount
Taking down chowkats (without taking of shutter from the frame) not exceeding 1.5 sq m each including making good the disturbed surface in CM 1:3 all as specified and directed
All as per Item No 1 above, but exceeding 1.50 sq m and not exceeding 4.00 sq m each
Demolition of cement concrete and paving not exceeding 15 cm thick (below or above ground level), removing debris to locations as directed by Engineer-in-Charge, complete all as specified and as directed.
Demolition of brick work /stone masonry / PCC block masonry built in cement mortar of any description all as specified and directed.
Removing building materials (Debris) to a distance of exc 1.0 km but not exc 1.50 kmm beyond the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in Framed work etc complete all as specified and as directed
Taking down cement plaster on brick or concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed.
Material and labour, for Plain cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in chajjas, coping, padding concrete, etc complete all as specified and directed.
Excavating in trenches, in soft / loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and getting out complete all as specified and as directed.
Returning, filling in (using soils), including spreading, leveling, watering and well ramming, soil in layers not exceeding 25 cm complete all as specified and as directed
Removing excavated surplus soil to a distance NOT exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed
Supply and laying 4 Core 16 Sq mm XLPE insulated, screened, bedded galvanized steel strip / wire armoured heavy duty with aluminum conductor, 1100 V grade, with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed. Note: Necessary cable protection works will be measured and paid for separately under respective items of this Schedule.
Material and labour for river sand cushioning as protection works to underground cables, including, watering, well ramiing in layers not exc 25 cm thick, complete all as specified and as directed. Note : Punned thickness of 18 cm will be measured and paid.
Supply and lay, in trenches, 40 mm bore Galvanized iron tubing, light grade, as cable protection complete all as specified and as directed.
Material and labour for laying of burnt bricks sub class `B’ bricks of size 230 x 115 x 75 mm, laid in trenches for cable protection all as directed and specified
Material and labour, for Pre-cast cement concrete block masonry with grade ‘C5’ solid blocks exceeding 10 cm in width, having minimum average compressive strength of 50 Kg / Sq cm as per IS 2185 (Part- I) 2005 and set in CM 1:6 complete all as specified and as directed.
S&F Pressed steel frames for doors of thickness not less than 1.25 mm, of profile 125 mm x 60 mm with double rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and as directed
Material and labour for Plain Cement Concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in filling the Chowkats/frames complete all as specified and as directed.
S&F Flush door shutters 35mm thick, factory made as per IS:2202 (Part-I 1999) solid core construction, with block board core with decorative choice lamination both faces with lipping / frame to match and fixed to chowkats all as specified and directed
S&F Box type Steel Windows/Ventilators double side shutters (Windows side hung type, Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm, windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified including 12mm square guard bars/grill welded with steel frame (100c/c horizontally) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard / Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges, Telescopic stays, locking arrangements and fixing of glass and wire mesh etc. (ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle, hinges and locking arrangements shall not be accounted for payment purpose . (Note : All Windows/Vent design as per CECZ TD drg No 539)
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and as directed
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Supply and fix, stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with mild steel screw & bolts all as specified and as directed.
Supply and fix, butt hinges medium weight cold rolled mild steel of size of hinges 100mm all as specified and as directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section of length 200 mm all as specified and as directed.
Supply and fix Extruded alloy handles cast type anodised of size 150 mm all as specified and as directed.
Supply and fix Aluminium alloy anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections, sliding door bolt 300 mm all as specified and as directed.
Supply and fix 150 mm floor door stopper of aluminium alloy powder coated, with hard drawn steel spring all as specified and as directed.
S&F in repairs stainless steel decorative curtain rod of 25 mm bore with wood finishes (weight not less 400 gms per running meter) incl fancy finale caps cap etc complete all as specified and as directed. Note : Price of curtain rod shall not be less than Rs. 100/- per RM
S&F in repair designer curtain rod bracket of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed
S&F grid suspended false ceiling grid system of size 600x600mm with main runner 29x24.7x0.8mm cross tee 29x24.7x0.8mm and wall angle 22.2x22.2x0.65mm. Ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastener, butter fly clips, hold down clips etc (Main runner, cross tee& wall angle of MS galvanized with PPPCGS) including 4mm thick HPSC self textured design pre primer non asbestos fibre cement building board fixed to false ceiling complete including taking down old ceiling of any description .
Material and labour for 4 mm thick plain sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sq m in each pane all as specified and as directed.
Material and labour for, preparing new steel surfaces of any description, over 10 cm width or girth, applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
Material and labour for, Rolled sections (of Grade Fe-410-W (E-250-Quality A) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
Material and labour for, Hollow sections as in beams, hip and jack rafters, purlins conforming to IS 4923 complete all as specified and directed
Supply and fabrication of hollow steel section as in framed work such as grills, gratings, ladders, balusters, walk ways, railing, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framework of water tanks and similar work confirming to IS 4923 complete all as specified and as directed.
Dismantling AC sheet in roof covering / cladding and providing material and labour, Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and as directed.
Dismantling AC sheet ridges / valley sheets in roof covering / cladding and providing material and labour, Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridge / valley to wall, fixed with self tapping screws all as specified and as directed.
M&L for 75 mm thick Plain cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of flooing etc complete all as specified and as directed
M&L for cement concrete type C-1, 1:3:6 (using 20 mm graded crushed stone aggregate) 75mm thick as in plinth protection, laid in alternate bays (not exceeding 2 Sqm each) finished the concrete surface even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed
Demolition of stone slabs and tiles of any description and providing Material and labour for providing, exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor, over and including cement screed bed of 15 mm thick in CM 1:6 complete all as specified and as directed
Demolishing paver block tiles, and providing material and labour for, Rubber moulded pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigments, laid over and including 50 mm thick sand cushioning complete all as specified and as directed.
Material and labour for, rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished plastered surface even and smooth without using extra cement complete all as specified and as directed
Material and labour for, rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement complete all as specified and as directed. Note :- Supply only WPC will be measured and paid separately
Supply only water proofing liquid complete all as specified and as directed
Complete removal of existing treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc complete all as specified and as directed
Preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparation of old plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 1 mm thick wall care putty, complete all as specified and as directed. Note : Quoted rate shall deemed to include for cost of wall care putty.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed.
Preparation of old plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed.
Taking up/down unserviceable Cast iron pipe from trenches / walls 100 mm dia, including CI specials, Providing material and labour for Galvanized iron, medium grade pipes of 100 mm dia, with all fittings, such as Tee, elbows, sockets, unions, short pieces, fixed to wall or laid in floors, complete all as specified and as directed. Notes: i) Necessary excavation, earthwork will be measured and paid under respective items. ii) Cost of Mild steel clamps, nuts, bolts, washers, etc., required for fixing pipes on walls, making holes in roof / walls and finishing the the disturbed surfaces matching with adjacent surfaces, shall deemed to be included in these items only.
Supply, installation, testing & commissioning of centrifugal pump cast iron body of 11 KW/15 HP, 3 Phase, 2900 RPM, Size 80 x 65 mm Suction & delivery monoblock pumpset of 68 Cu m / Hr @ Min. 32 Mtr Head (Max. 55 Mtr Head) with bronze impellers including provision for fixing safety valve, non return valve etc., coupled with 3 phase induction, motor suitable for operation on 415V AC with love joy rubber coupling with channel iron base frame including nuts, bolts & washers etc., PCC foundation, foundation nuts, bolts & washers as per manufacturer instructions complete all as specified and as directed. Make : Kirloskar, Model Type - KDS-1555 or techno commercial equivalent makes specified here-in-after.
Supply and fix, fully automatic motor starter for 15 HP pumpset ML 1.5 FASD type suitable for 10/20/25 HP motor. Make : - L&T Cat No S91856POAO/ SS91856POCO/ SS91856POEO or techno commercial equivalent makes specified here-in-after.
Disconnecting and taking out existing sluice valve, supply and laying new Sluice valve (cast iron body) with both ends flanged and iron wheel handle for clockwise operation, brass spindle heavy duty PN-1.6 class (IS-14846/2000), ISI marked, including 3 mm thick rubber gasket joint, nut, bolts & washers all as requirement of site for 100 mm dia pipe, complete all as specified and as directed.
S&F in replacement of non return valve flanged and threaded type including complete fixing accessories like nuts, bolts, packing etc of size 100 mm dia
Taking out unserviceable foot valve, supply and fix 100 mm dia Cast Iron foot valve, connecting up in CI pipe line, complete all as specified and as directed.
Material and labour for, Construction of valve chamber of internal size 1.25 M x 1.25 M x 1.0 M in depth with PCC (1:4:8), type D2 (using 40mm graded stone aggregate), 100mm thick for foundation with 100 mm offset for all the sides from outer face of walls, walling with PCC Solid block masonry (Grade C5) set in CM (1:6), 15 mm thick plastering to the internal surfaces in 10 mm thick CM (1:4), 50 mm thick coping in PCC (1:2:4), type B-1 (using 20 mm graded stone aggregate), mild steel cover made out of angle iron of size 50 x 50 x 6mm as in sides of frame and 3mm thick MS sheet, fixed with split type hold fast- 4 Nos made out of flat iron of size 40 x 6mm, 250 mm long duly embedded in coping and fitted to angle iron frame with 03 Nos of suitable hinges provided with necessary locking arrangements including preparation and applying black bituminous paint over a coat of red oxide primer on exposed steel surface and one coat of coal tar painting on steel surface embedded inside the concrete, complete all as specified and as directed.
Material and labour, for bracket made of Galvanized iron pipe 40 mm dia, light grade, bend to shape not less than 1.5 mtr with 2 Nos of MS clamps fabricated out of MS Flats of size 32 x 6 mm, bolts , nuts of suitable size for fixing street light fittings complete all as specified and as directed.
Supply and fix 72 W, LED Street light fittings (outdoor type) with lamp, designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics, and IP66 protection, Efficacy ≥ 110LPW, 10KV SPD Included, electrical efficiency > 85%, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, as per Cat No ZELA P 86 L WH PO TG SD of Bajaj make or techno commercially equivalent makes specified here-in-after complete all as specified. Note: - Electric cable from looping box to fitting will be measured and paid separately under respective item.
Supply and fixing, multi stranded copper conductor wiring, with FRLS grade PVC insulated unsheathed, 1100 volts grade, 2 runs of single core of size 2.5 Sq mm and one run of earth continuity conductor of size 2.5 Sq mm to be drawn through and including 20 mm dia rigid non metallic PVC conduit complete all as specified and as directed. NOTE: - Two runs of 2.5 sq.mm cable, one run of 2.5 sq mm earth wire and PVC conduit shall be measured as one length.
Supply and fix, FRP body, loop in / loop out boxes, of size not less than 240 mm x 130 mm x 110 mm (out door type) including provn of MCB SP 6 Amps of 1 Nos ('C-Curve type), fitted on poles with suitable size clamps made out of MS flat iron of size 20 x 5 mm GI nuts, bolts and washers complete with 4 way terminal strip (heavy duty) connector - 1 No, including provision of cable glands of suitable size complete all as specified and directed.
Material and labour for, earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1, manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTE :- Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Supply and fixing Timer switch box fabricated out of 16 SWG CRCA sheet (Min size of box 0.80 m x 0.80 m x 0.30 m) with mounting and locking arrangement duly powder coated consisting of following :- (a) Digital timer, 110 A, 3 P, 230 V, all as per Indo Asian Cat Part No. TL11ODB0 of Indoasian or techno commercially equivalent in other makes specified - 01 No (b) Power contactor 63 Amps Make: L&T/Havells/INDOASIAN- 01 No. (c) Connector 100 Amps 230 volts - 03 Nos. (d) MCCB TP 63 Amps 415 volts - 01 No. (e) Control fuse 2 Amps - 01 No.
Horizontal trenchless bore drilling using mechanical pneumatic drilling equipment for passing, including cost of HDPE pipe of 80 mm dia (0.4 mpa working pressure) hard standing, depth exceeding 0.75m and not exceeding 1 m and making good to disturbed surface of road all as specified and as directed. Note: Unit rate shall deemed to be incl cost of deposit and taking permission from civil authorities.
M.S.Trading Company
Elite Constructions
OM CONSTRUCTIONS
Atom Engineers and Builders
S CHANDRASHEKAR (SREE BUILDERS)
deepak kumar vishwakarma
PRAGATHI BUILDERS
Srisrinivasaenterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .