Loading…
Loading…
Tender Value
₹8.6 Cr
EMD Value
₹17.3 L
Closing Date
22 May 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DD TO SUR
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where V= Advertised value of the tender in crores of Rupees & N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Indoor or combined Indoor& Outdoor Signalling work including design, supply Installation testing and commissioning of Electronic Interlocking system for passenger carrying lines. OR Any Indoor or combined Indoor & Outdoor Signalling work including Supply, Installation testing and commissioning of relay interlocking (RRI/PI) system/ABS/IBS for passenger carrying lines.
4 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please refer to GCC with ACS and Instructions to tenderer attached in Documents.
Signalling work in connection with "Provision of additional two loop lines & provision of Shunting neck and A&D siding" at Boribial station of Solapur Division of Central Railway.
SUR-N-T-2026-27-06
SUR-N-T-2026-27-06
Open
Works - General
12 Months
Solapur, Maharashtra
₹0
₹17.3 L
22 May 2026
28 Apr 2026
8 May 2026
217 items across 5 schedules · ₹7,93,13,161.58 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of tool kit- required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as per schedule item 1 above. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose plier etc. & measuring instruments with carrying case/ holders/cabinet for technicians/ J.E. or testing, Maintenance and repair at site). Each set comprises of the following :- (a) Crimping tools for all types of special cable assembly used in EI system. (b) Insertion tool for all types of special cable assembly used in EI system. (c ) Removal tools for all types of special cable assembly used in EI (d) Digital multimeter (Tektronics/Fluke/MEGGER/RISHAV or better) system. (e) Steel cabinet / Almira (Godrej/Durian/Transteel) of good quality to store tool, spare cards and documents. (f) Clamp Earth Tester. (Fluke 287/MEGGER/RISHAV or better) (g) Clamp Current Meter. (Fluke 287/MEGGER/RISHAV or better) (h) 6 nos. Electrostatic Discharge Wrist Band for cards modules protection. | Set | 1.00 | 1,06,064 | 1,06,064 |
| 2 | Supply of as made documents (Manuals for Installation, Testing, and maintenance of the system) (One set consists of 6 set of following drawings per station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians/Jr. Engineers. (Installation and maintenance level ) (ii) Functioning and system overview (Higher Management Level) (iii) Completion documents as per special conditions of contract. (iv) Design & supply of circuits and plans to suit layout given in the signaling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plan and wiring diagram shall be prepared on AutoCAD Drawing and supplied with CD. This will include supply of Control-cum-Indication Panel/VDU diagram, Square sheet, wiring diagrams (Application Logic and Interface circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power supply Distribution / Power Equipment arrangement (with program switch) Diagram, Auto change over diagram (if supplied by the contractor), and all other relevant drawings.NOTE : The contractor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure that each sheet has a block for signature of Railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of comments by Railways, the Contractor will make copies of the approved documents and return the approved documents to Railways. The contractor will then make necessary correction to Application Logic Software duly incorporating Railways' alterations/corrections/comments, if any. After complete testing/ commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways for approval. Along with the completion application logic, difference report (showing addition & deletion in different colors) as compared t o earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of duly approved completion tracings will be submitted to Railways. | Set | 1.00 | 1,34,635 | 1,34,635 |
| 3 | Supply of Portable work station for Data input & configuration with necessary software/AutoCAD latest version programmes/Accessories, simulation and functional Testing, diagnostics and trouble shooting and commissioning of EI system. Suitable Table & Chair or reputed make shall be supplied by the contractor. The specifications of the PC / Laptop should be got approved from the Engineer in charge before supply. Note : Portable work station should strictly adhere to specification as per annexure-I. | Set | 1.00 | 1,46,679 | 1,46,679 |
| 4 | Supply of Relay rack assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure-II and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge. | Set | 4.00 | 30,325 | 1,21,300 |
| 5 | Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations. | Set | 6.00 | 26,006 | 1,56,036 |
| 6 | Supply of Data logger for monitoring status of important relays, complete with processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec. No: IRS:S-99/2006 (Amdt-3) with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module (computer) as per Annexure-IV shall be placed in President rack of suitable size to be supplied. This also includes supply of one no. composite computer & printer table (work station table-Godrej/Durian/Transteel) for keeping processor module and one no. Godrej/Durian/Transteel make operator chair. ii)2560 digital and 32 analog inputs. | Set | 1.00 | 8,22,218 | 8,22,218 |
| 7 | Supply of PVC Indoor cable 1x60x0.6mm dia color coding of insulation of inner core shall be in six color viz Blue, Red, Grey, Green,Brown & Black conforming to IRS 76/89 (Amd.3) or latest. | Kilometre | 2.00 | 2,60,430 | 5,20,860 |
| 8 | Supply of PVC Indoor cable 1x40x0.6mm dia color coding of insulation of inner core shall be in eight color viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. | Kilometre | 2.00 | 1,70,848 | 3,41,696 |
| 9 | Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 conductor each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | Kilometre | 1.00 | 76,141 | 76,141 |
| 10 | Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | Kilometre | 3.00 | 1,19,222 | 3,57,666 |
| 11 | Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | Kilometre | 2.00 | 1,77,112 | 3,54,224 |
| 12 | Supply of PVC flexible copper cable single core, multistrand 1x25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. | Kilometre | 1.00 | 2,79,653 | 2,79,653 |
| 13 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. | Kilometre | 10.00 | 5,605 | 56,050 |
| 14 | Supply of low maintenance Lead Acid secondary cells 2V 80AH as per spec. IRS 88/2004 version 1.0 with latest amendments. | Numbers | 150.00 | 1,645 | 2,46,750 |
| 15 | Supply, installation, wiring, testing & commissioning of Microcontroller based Power Supply Autochangeover device complete along with accessories using Contractor's own wiring & fixing material as per following configuration- (i) Power Supply - AC/DC. (ii) Voltage 24V to 150V. (iii) Current Up to - 45Amp. Note: The work shall be done as per instructions of Railway's Engineer in-charge | Numbers | 20.00 | 31,274 | 6,25,480 |
| 16 | Supply of QNA1-K AC immunized relay, 8F-8B, 24 VDC along with plug, retaining clip and connectors conforming to BRS:931A & RDSO letter no STS/E/Relays/UEA/PI dated 30.05.97 Annexure-II IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | Numbers | 20.00 | 3,540 | 70,800 |
| 17 | Supply of QNA1 AC immunized relay, 8F- 8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | Numbers | 80.00 | 3,359 | 2,68,720 |
| 18 | Supply of QN1 Non AC immunized neutral relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 | Numbers | 40.00 | 3,507 | 1,40,280 |
| 19 | Supply of QNN1 Twin neutral line relay, 24 V DC 4F- 4B/5F-3B/6F-2B contacts, complete with plug, board, retaining clip and connectors BRS:960 | Numbers | 40.00 | 5,322 | 2,12,880 |
| 20 | Supply of QSPA1 relay, 24 V DC Slow to pick up, 8F- 4B along with plug, board, retaining clip and connectors conforming to BRS:933 IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) | Numbers | 40.00 | 3,678 | 1,47,120 |
| 21 | Supply of QTA2 AC immunized track relay, 9 Ohm, 2F.1B, along with plug, board, retaining clip and connectors conforming to BRS:939A, 966 & Appendix F2, IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) | Numbers | 50.00 | 3,241 | 1,62,050 |
| 22 | Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B, AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL) | Numbers | 40.00 | 3,317 | 1,32,680 |
| 23 | Supply of QBCA1 AC immunized relay, 2FHD 4F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:943 POINT CONTACTOR RELAY. And RS S46/74 with Amendment No.1 & firms specification. | Numbers | 10.00 | 4,062 | 40,620 |
| 24 | Supply of QL1 LATCH relay, 11F-4B or 8F- 6B along with plug board, retaining clip and connectors conforming to BRB:935A. | Numbers | 10.00 | 4,006 | 40,060 |
| 25 | Supply of Key Lock Relay working on 24V DC, AC immunized with different ward combinations (Three ward plates to be supplied with each relay). RDSO/SPN/219/2016 Version 1.0 with Amendment No.01. | Numbers | 20.00 | 6,059 | 1,21,180 |
| 26 | Supply of Block filter unit as per IRS:S- 68/89 and Block bell equipment as per IRS:TC-44/88 (Amd. 1). | Numbers | 2.00 | 19,090 | 38,180 |
| 27 | Supply of Block Bell equipment as per RDSO Drg. No.TCA 15080 and Spec. No IRS-TC-44/88 (Amd.1) with amendment No. 1 Voltage 24 V DC. | Numbers | 2.00 | 2,771 | 5,542 |
| 28 | Supply of PPTC Fuse GP 60-185 UL-94 certification (1.6 Amps) for internal / external current. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | Numbers | 400.00 | 8 | 3,200 |
| 29 | Supply of PPTC Fuse GP 60-400 UL-94 certification (12V/4A) TF, TR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | Numbers | 400.00 | 7 | 2,800 |
| 30 | Supply of PPTC Fuse GP 30-100 (24V/1.4A) TPR Circuit. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | Numbers | 400.00 | 7 | 2,800 |
| 31 | Supply of PPTC Fuse GP 250-185 UL-94 certification (24V/4A)110V AC for track chargers. Make: LITTLEFUSE, FUZETEC, TYCO, BOURN, RAYCHEM etc. | Numbers | 400.00 | 7 | 2,800 |
| 32 | Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. | Kg | 10.00 | 1,078 | 10,780 |
| 33 | Lacing thread rolls, black, wax coated (100 mtrs) | Numbers | 100.00 | 57 | 5,700 |
| 34 | Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one c a r d . As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. | Each Module | 20.00 | 23,147 | 4,62,940 |
| 35 | Design, fabrication and supply of fuse Auto changeover system for 24 Nos external non detorating type fuses or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operation circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one c a r d . As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. | Each Module | 10.00 | 33,712 | 3,37,120 |
| 36 | Supply of Main signal post 140 mm outer dia 3.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. | Numbers | 4.00 | 5,908 | 23,632 |
| 37 | Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. | Numbers | 6.00 | 5,979 | 35,874 |
| 38 | Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. | Numbers | 10.00 | 8,119 | 81,190 |
| 39 | Supply of Shunt signal post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.) | Numbers | 10.00 | 2,650 | 26,500 |
| 40 | Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. | Numbers | 20.00 | 7,944 | 1,58,880 |
| 41 | Supply of Signal No.Plates as per Drg No RST-11393/ SK-842 | Numbers | 50.00 | 447 | 22,350 |
| 42 | OFF set bracket 5-1/2" to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes. | Numbers | 4.00 | 821 | 3,284 |
| 43 | OFF set bracket 3-1/2' for signals & Routes. Drawing No.SA23840(Adv) Alt-2 as per extent C.Rly practice. | Numbers | 4.00 | 4,129 | 16,516 |
| 44 | Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA- 23460(AG), SA-23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment. | Numbers | 40.00 | 476 | 19,040 |
| 45 | Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. | Numbers | 100.00 | 245 | 24,500 |
| 46 | Supply of "2 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost | Numbers | 12.00 | 25,824 | 3,09,888 |
| 47 | Supply of "3 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost | Numbers | 8.00 | 26,638 | 2,13,104 |
| 48 | Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps. | Numbers | 15.00 | 11,731 | 1,75,965 |
| 49 | Supply of 3 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | Numbers | 2.00 | 38,672 | 77,344 |
| 50 | Supply of 4 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | Numbers | 2.00 | 38,485 | 76,970 |
| 51 | Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps | Numbers | 10.00 | 7,154 | 71,540 |
| 52 | Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995. | Numbers | 50.00 | 4,649 | 2,32,450 |
| 53 | Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. | Numbers | 6000.00 | 65 | 3,90,000 |
| 54 | Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA-23749 & Spec No.IRS S 75/2006 Re v. 0 2 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. | Numbers | 400.00 | 144 | 57,600 |
| 55 | Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity | Numbers | 200.00 | 62 | 12,400 |
| 56 | Supply of Tik-tak, piano type switches, 5 A (as per IS Specification). | Numbers | 100.00 | 30 | 3,000 |
| 57 | Supply of three pole plug and socket 5 Amp (as per IS Specification). | Numbers | 100.00 | 205 | 20,500 |
| 58 | Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration. | Numbers | 50.00 | 14,252 | 7,12,600 |
| 59 | Supply of Apparatus case with godown locks with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration. | Numbers | 30.00 | 11,287 | 3,38,610 |
| 60 | Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815 | Numbers | 120.00 | 951 | 1,14,120 |
| 61 | Supply of Lightning strike recorder LSC 6 digit shall be weather proof type. It should have 6 digit event count & the capacity to count smallest strike (3KA). It should be voltage sensing type counter. So that it will register nearby strikes & static discharge due to induction effect. as per IS 2309:1989. | Numbers | 2.00 | 12,067 | 24,134 |
| 62 | Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. | Set | 40.00 | 15,671 | 6,26,840 |
| 63 | Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode. | Metre | 100.00 | 365 | 36,500 |
| 64 | Supply of copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round). | Metre | 100.00 | 711 | 71,100 |
| 65 | Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. | Numbers | 3.00 | 1,18,645 | 3,55,935 |
| 66 | Supply of Track Lead junction Boxes as per C.Rly Drg.No.RST 11509 made from fiber glass alongwith terminal blocks. | Numbers | 150.00 | 878 | 1,31,700 |
| 67 | Supply of B type choke to specn.No.IRS.S.65/83 (Amd.3 ) with latest amendments. | Numbers | 50.00 | 3,099 | 1,54,950 |
| 68 | Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments ( with phenolic moulded base). | Numbers | 50.00 | 1,089 | 54,450 |
| 69 | Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS.89/2013 Ver.1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. | Numbers | 50.00 | 2,001 | 1,00,050 |
| 70 | Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3. | Numbers | 8000.00 | 2 | 16,000 |
| 71 | Supply of PVC jacketed wire rope for Track lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed for recycled material should not be used. | Metre | 5000.00 | 46 | 2,30,000 |
| 72 | Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13-62 | Kg | 1000.00 | 75 | 75,000 |
| 73 | Supply of Digital Axle counter Multi section type complete system including the central Evaluator and final track clearance relay for each section, Reset boxes, LV boxes, All track side units with detection point complete assembly & fixing arrangement for each detection point, clamps deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station/RH/IBH etc. with all other accessories fully wired and fully equipped as per RDSO specification No.RDSO/SPN/176/2013 (ver.3) or latest and manufacturers specification. The equipment must also include the following: a) System must have remote monitoring and health diagnostics feature as per RDSO specification. b) Surge protection device, c) 20% spare slots for the both detection heads and track section in the evaluator for future and emergency provision. Each set also consisting of a) Double rail contact of standard length of cable as per site requirement and mounting accessories - Equal to no. of DP. b) Deflectors to safe guard Rail contact will be TWICE the no. of DPs. c) Protecting tube from DP to railhead as per requirement. d) Diagnostic PC as per specification and other accessories (as per Annexure-VI) e) Pre- wired cabinet/rack - No. as per site requirement. f) 6 nos. Electrostatic Discharge Wrist Band for cards/modules protection. | Per Detection Point (DP) | 50.00 | 2,88,366 | 1,44,18,300 |
| 74 | Supply of single section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO/SPN/177/2012 Ver.03 or Latest. Each set consist of following:- a) High frequency TX coil and RX coil (Each set consist of web mounting type TX coils- 2 Nos. RX coils-2 Nos along with 10 mtr cable-2 sets), b)Track side digital axle counter unit.-2 nos. c) 24V 6F/4B, 1000 ohm "Q" type relay Box duly wired - 2 Nos. d) Clamp with detector plates and hardware etc-4 Nos e) Reset Box 2 Nos ii) Mushroom/Location Box suitable for housing Track side equipment (2 Nos.) 2) Transportation, Installation testing & commissioning:- Transportation, Installation testing & commissioning of equipment field training (one man day per set) at site or as desired by site Engineer. These includes:- a) Foundation & erection of Track side Equipment i.e. Mushroom/ Location Box (If required). This includes supply of all associated materials., b) Individual Earthing of all detection Point for the OEM recommended earth value certified by OEM site engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec.no: RDSO/SPN/197/2008 or latest. Resetting equipment to the connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer. 3) Tool Kit consisting of :- a) Digital True RMS multi meter of suitable make for above Digital Axle counter system with probe set- 1no b) Train Simulator (High frequency)-1 no c) Extender Card - 1 no d) Dummy wheel- 1 no e) Different type of spanners suitable for above Digital Axle counter - 1 set f) Torque wrenches suitable for the aboe-1 no g) Screw driver set suitable for the above - 1 set. h) Carrying Bag for Tools - 1 no i) 6 nos Electrostatic Discharge Wrist Band for cards/ modules protection. | Numbers | 4.00 | 3,93,822 | 15,75,288 |
| 75 | SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. | Numbers | 40.00 | 2,387 | 95,480 |
| 76 | Supply of William stretcher nylong insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendments. | Set | 100.00 | 452 | 45,200 |
| 77 | Supply of Tongue attachment nylon insulation set consisting of one inlsulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST- 10692 | Set | 100.00 | 287 | 28,700 |
| 78 | Supply of Gauge Tie Plate nylong insulation as per RDSO drg No: T-10372 Alt2, T-10368, T-10371 Alt2, T- 15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23/88 with Amendment No.01 & 40/84 with Amendment No.01 or latest amendments. | Set | 100.00 | 207 | 20,700 |
| 79 | Supply of Ground connections, complete set suitable for IRS type/appd. Point Machine for ordinary turnout with tounge attachment insulation and other insulation as per RDSO Drg.S/3361 /62 / 63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. | Set | 12.00 | 7,018 | 84,216 |
| 80 | Supply of Ground connections, complete set suitable for IRS type/appd. Point Machine for derail switch with tounge attachment insulation as per RDSO Drg.S/3361 / 62 / 63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 with latest amendements. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. | Set | 4.00 | 5,707 | 22,828 |
| 81 | Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. | Metre | 180.00 | 908 | 1,63,440 |
| 82 | Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. | Metre | 540.00 | 288 | 1,55,520 |
| 83 | Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. | Numbers | 4000.00 | 189 | 7,56,000 |
| 84 | Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. | Numbers | 3000.00 | 365 | 10,95,000 |
| 85 | Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. | Numbers | 5000.00 | 100 | 5,00,000 |
| 86 | Supply of DIN Channel for the terminals 1 Mtrs each | Numbers | 70.00 | 187 | 13,090 |
| 87 | Supply of End plates for modular terminal block | Numbers | 700.00 | 20 | 14,000 |
| 88 | Supply of End Clamp for modular terminal block | Numbers | 700.00 | 15 | 10,500 |
| 89 | Fuse terminals block with LED indication up to 2.5 sqmm screw type one in one out (suitable for (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10 A ) as per RDSO SPN/189/2004 Ver.03 or latest . (without fuse) | Numbers | 150.00 | 157 | 23,550 |
| 90 | End plate for through terminal block with LED indication. | Numbers | 120.00 | 12 | 1,440 |
| 91 | Fuse links of (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10A) | Numbers | 600.00 | 37 | 22,200 |
| 92 | Shorting link insulated Grey in colour | Numbers | 75.00 | 13 | 975 |
| 93 | Operating tool (operating tool, screw driver & stripper) as per Annexure-VII. | Numbers | 1.00 | 7,266 | 7,266 |
| 94 | Tool bag complete with Megger as per Annexure- VIII. ADD AC / DC clamp meter, with Hand Held Tool Bag. | Set | 1.00 | 42,990 | 42,990 |
| 95 | Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make. | Numbers | 2.00 | 3,856 | 7,712 |
| 96 | Supply of Paints as per relevant IS specification preferably Asian / Apcolite/ Dulux make in different colour in one kg/2 kg pack | Kg | 100.00 | 306 | 30,600 |
| 97 | Supply of 4.5 kg CPO2 type fire extinguisher along with all accesories, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon Dioxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket etc. as required by site Engineer. | Numbers | 12.00 | 4,321 | 51,852 |
| 98 | Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm control Panel with LCD display complying to RDSO/SPN/217/2025 Ver 3.1 or latest modular, 1 loop (minimum 125 detector/devices per loop-expandable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation function, Remote maintenance service feature etc. The panel should be multi- protocol i.e. able to support at least 2 different makes of addressable detectors. The panel should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition. Panel should be Vds Certified. | Numbers | 1.00 | 55,467 | 55,467 |
| 99 | Suply, Installation, Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Numbers | 80.00 | 2,748 | 2,19,840 |
| 100 | Suply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Numbers | 2.00 | 4,313 | 8,626 |
| 101 | Suply, Installation, Testing & Commissioning of Resettable, Analogue Type Liner Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Metre | 60.00 | 1,167 | 70,020 |
| 102 | Suply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Numbers | 1.00 | 1,10,725 | 1,10,725 |
| 103 | Suply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection unit complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Numbers | 1.00 | 2,22,716 | 2,22,716 |
| 104 | Suply, Installation, Testing & Commissioning of CPVC pipe for Aspiration Detection system complying toRDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed /approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. | Metre | 80.00 | 1,320 | 1,05,600 |
| 105 | Suply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. | Numbers | 4.00 | 7,151 | 28,604 |
| 106 | Suply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2025 Ver 3.1 or latest. | Numbers | 4.00 | 7,151 | 28,604 |
| 107 | Suply, Testing & Commissioning of Hooter cum strobe complying to RDSO/SPN/217/2025 Ver 3.1 or latest. | Numbers | 2.00 | 6,394 | 12,788 |
| 108 | Suply, Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/2025 Ver 3.1 or latest. | Metre | 100.00 | 94 | 9,400 |
| 109 | S u p l y , Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to the RDSO/SPN/217/2025 Ver 3.1 or latest. | Numbers | 1.00 | 3,071 | 3,071 |
| 110 | Suply, Testing & Commissioning of Auto Telephone Dialler (GSM) to send the pre- recorded message to multiple mobile numbers, programmed earlier, complying to the RDSO/SPN/217/2025 Ver 3.1 or latest. | Numbers | 2.00 | 7,413 | 14,826 |
| Schedule total | ₹3,17,25,354 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Instructions_To_Tenderer_BRB.pdf
ATTACHMENT
Special_Conditions_EI_at_BRB.pdf
ATTACHMENT
GCC_April-2022_with_ACS_11_13032026.pdf
ATTACHMENT
Tender_form_Annexure-I.pdf
ATTACHMENT
Cable_cut_policy_CR_1st_Sept_23.pdf
ATTACHMENT
Inspection_Agency_Details.pdf
ATTACHMENT
Annexures__Drawings_BRB.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .