Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹27.0 LAdmitted-Finance | -22.00% | ₹27.0 L | L1 | Admitted-Finance |
| 2 | L2₹32.5 LAdmitted-Finance | -6.00% | ₹32.5 L | L2 | Admitted-Finance |
| 3 | L3₹33.8 LAdmitted-Finance | -2.45% | ₹33.8 L | L3 | Admitted-Finance |
| 4 | L4₹35.6 LAdmitted-Finance | +2.86% | ₹35.6 L | L4 | Admitted-Finance |
| 5 | L5₹37.4 LAdmitted-Finance GSTIN: 08AAFFK1430P1Z6, 08AAKFK1306P1Z2, 08AAKFK5450E1ZC, 08AJGPB2827H1ZG, 08APMPR6702D1ZS, 08EOYPS2255P1ZO | +8.00% | ₹37.4 L | L5 | Admitted-Finance |
Tender Value
₹34.6 L
EMD Value
₹69,240
Closing Date
23 Mar 2026, 1:00 pmClosed
Executive Engineer 16TH Division IGNP Bikaner
O/o Executive Engineer 16TH Division IGNP Bikaner
Repair and renovation of V type qtr. No 11 to 20 in CC Bikaner
2026_IGNP_545935_8
NIT 20 of Year 2025-26
Open Tender
Civil Works
150 days
BIKANER
Firm Registration , Bid fee and security in Egras, GST clearance upto 01/26, Labour certificate 1948,1952,1970
2 documents required · 2 mandatory
₹1,000
Executive Engineer, 16th Division, IGNP, Bikaner
₹69,240
Yes
30 Mar 2026
13 Mar 2026
23 Mar 2026
13 Mar 2026
23 Mar 2026
13 Mar 2026
13 Mar 2026 - 23 Mar 2026
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50m lead.
Precast terrazo tiles of approved make, 20mm thick with marble chips of size upto 6mm laid in floors, and landing, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete on 20mm thick bed of cement sand mortar 1 : 4. Light shade using white cement .
P & F 1st quality Vitrified tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. : size 600 mm X 600 mm .
Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Add extra over item of brick work with class designation 10.0 in substitution of class designation 7.5.
Plaster on new surface on wall in cement sand mortar 1:6 including racking of joints etc. Complete fine finish:20mm thick.
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete .
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats) with lime including scrapping old surface and necessary repairs.same colour .
Finishing wall with water proofing cement paint of required shade including all scaffolding :Old work (one or more coats).
Providing and fixing 1st quality standardmarble printed / granite shade or dark shade tiles in glazed tiles confirming to IS:13753 & Is:15622 of size up to 200*300mm in walls, steps,pillars etc. Laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete ( excluding the cost of cement plaster on walls and pillars). extra for using size 300*450 mm in glazed tiles
Providing and fixing 1st quality MAT finished ceramic tile size300*300mm confirming to IS : 15622 colour such as marble printed / granite shade or dark shade tiles in floor , steps , pillars etc. Laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry :Size 75x 75mm
Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick..
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jhunjhunu / Jalore (Red / Choclate Colour) upto 1500 Cm2 Slabs
P&F external grade board solid core single / Double leaf flush door shutter IS : 2202 ( part -2) 1996 marked using phenole formel dehyderesin in glue both side with approved stainless steel fitting complete as per annxure' A' : 25 mm thick commercial vaneer both side .
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old Work
P&f steel glazed doors , window and ventilators shutters of standerd rolled steel section joints mitred and welded with steel lungs 13*3 mm , 10 cm long embedded in cement concrete block 15*10*10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggrigate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with and nuts as required including providing and fixing of plain glass panes 4 mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws completes including priming coat of approvel steel primer , excluding the cost of metal beading and other fitting except necessary hings of pivots steel handles pegs stay etc. as required : window fixed .
Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete.
Renewing glass panes, with putty and nails wherever necessary: Float glass panes of thickness 4 mm .
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Enternal work Exposed on wall)
P&F on wall face UPVC rain & soil waste ( SWR ) pipes conforming to IS : 13592 including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion ; single socket : type B : 110 mm dia .
single tee with door 110 mm dia .
single bend with door 87.5 degree 110 mm dia .
P&F wvc wash basin ( 1st qlty IS : 2556 mark ) of approved make with C.I brackets duly painted one no's 15 mm CP pillar cock ( IS : 8934 mark ) and 25 mm CP brass waste coupling of approved make 32mm waste pipe complete including cutting and making good the wall : size 580mm*450mm dia for counter top
P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor .
P & F Toilet Shelf of approved quality/make: Acrylic shelf on C.P. brass casted brackets
P & F Copper tube Syphon for auto flush tank.
P & F bib cock (IS:8934 Mark), superior quality of approved make : C.P. bib cock fancy type , 15 mm nominal bore .
P & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make:C.P. Pillar cock, 15 mm dia nominal bore.
P & F shower arm 15 mm dia of approved quality /make:C.P. Brass heavy and superior quality 150 mm projection.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet of approved quality/make.150 mm Dia.
P & F Jet spray for water closet with C.P. Copper Tube flange of approved make..
P & F Inlet Connection (Angle Valves) Superior quality,of approved make, for Wash basin,Gyser etc.: C.P. Inlet connection 15 mm Brass (IS:8931 marked).
P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floor :1 mm thick stainless steel AISI-304 & IS 13983-1994 KItchen sink of approved make as per er incharge with large waste coupling . size 22*18*8 .
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.
Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .5 step fan regulator
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 4.0 sq.mm
500.4.1.6Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS: 8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 2.5 sq.mm
200.7.15.1Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6A to 32 A.
Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.Applying Epoxy primer on the exposed steel bars.Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.Speading dry cement mortar 1 : 2 mix over epoxy treatePlastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.d wet surface and allow it to dry for one day.Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect.
P & F Stop Cock (IS :8931 Mark), superior quality & of approved make concealed stop cock 15mm .
Hand shower with 8mm dia 1 m long pvc tube & wall hook complete.
Synthetic material (PTMT) of approved make 15mm nominal size.20 mm nominal size.
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.8 Way (8+2).
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.Double pole MCB(With B/C curve tripping Characteristics). 50/63 A rating.
Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge.As per pwd bsr 2022 code no 10.16 ch B-10
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Dismantling tar felt over roofing complete including stacking of serviceable material and disposal of unserviceable material within 50-meter lead.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : .
Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.
Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only).
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
500.1.4.1S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories with own OEM CM/L No. as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR - 20 mm
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_973637.pdf
techsummary_973637.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
8.pdf
Tender Documents • 1.74 MB
BOQ_973637.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid