Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.0 L+₹1.0 L (10.3%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹12.1 L+₹2.1 L (21.6%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹15.0 L+₹5.0 L (50.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹15.5 L+₹5.5 L (55.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
13 Jun 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF OF DBs, SUBMAIN WIRING, EARTHING, BUILDING SECURITY LIGHTS AND MISC WORKS AT MD ACCN AND OTM ACCN AT VASANT RANGE COLONY, 5 RAJPUT, IHQ OF MOD (ARMY) CAMP, WARDEC AND HQ DGIS UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2023_MES_595737_1
GE/DS-17/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹60,000
Yes
6 Jul 2023
16 May 2023
15 Jun 2023
16 May 2023
13 Jun 2023
30 May 2023
Amount
S&F in repairs sheet metal enclosure V TPN 4 way Double door DB, IP-43 bus bar neutral link earth bar and din rail etc. complete all as specified and as directed.
S&F in repairs sheet metal enclosure for DB's, where MCB's to be used Single pole and Neutral 12 way, 240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and as directed.
S&F in repairs sheet metal enclosure for DB's, where MCB's to be used Single pole and Neutral 8 way, 240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and as directed.
S&F in repairs sheet metal enclosure for DB's, where MCB's to be used Single pole and Neutral 4 way, 240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and as directed.
S&F in repairs MCCB 160 Amps, 4 Pole, 415 Volts with 25 kA rupturing capactiy including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing etc. complete all as specified and as directed.
S&F in repairs MCCB 125 Amps, 4 Pole, 415 Volts with 16 kA rupturing capactiy including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing etc. complete all as specified and as directed.
S&F in repairs MCCB 100 Amps, 4 Pole, 415 Volts with 16 kA rupturing capactiy including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing etc. complete all as specified and as directed.
S&F in replacement MCB TPN/ Isolator 4P from 63/100 Amps 415 volts, 'B' Series 10 kA including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing etc. complete all as specified and as directed.
S&F in repairs MCB SPN 'B' curve 40/63 Amps, 240 volts, 10 kA including electrical connection with suitable size of thimble complete all as specified and as directed.
S&F in repairs MCB SP 'B' curve 6 to 32 Amps, 240 volts, 10 kA including electrical connection with suitable size of thimble complete all as specified and as directed.
S&F in replacement single pole metal clad sheet metal enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per sample type complete all as specified and directed.
M&L in replacement submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through and including PVC conceiled conduit of size 25mm dia complete all as specified and as directed.
M&L in replacement submain wiring of two runs of 4 Sqmm size for main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through and including PVC conceiled conduit of size 25mm dia complete all as specified and as directed.
M&L in replacement submain wiring of two runs of 2.5 Sqmm size for main cable and one run of 2.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through and including PVC conceiled conduit of size 20mm dia complete all as specified and as directed.
M&L in replacement submain wiring of two runs of 2.5 Sqmm size for main cable and one run of 2.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through and including PVC casing capping of suitable size suitable complete all as specified and as directed. Note for item No 12 to 15:- (i) Phase should be Red/Yellow/Blue, Neutral should be Black and Earthing wire should be of Green colour. Two runs of cable for 3 phase, neutral and one run of earth wire will be measured and paid as one unit length. (ii) The rates are inclusive of cutting/chasing and making good the disturbed surfaces with CM 1:3 and with OBD/Colour wash/white wash etc. as per existing complete.
M&L in repairs Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering, all as shown in Electrical Plate No.05 of SSR-2009 (Part-I) and connected to earth test point including testing etc. complete all as specified and as directed.
S&F in repairs earth continuity conductor/main earthing lead fixed to wall on batten, buried in ground, drawn in conduit pipe or fixed, poles or any other indicate situation for loop earthing etc. as required 4 mm dia galvanised iron wire compelte all as specified and as directed.
S&F in repairs LED post top lantern fitting with die cast aluminium spigot, spun aluminum powder coated top cover Aluminum PDC heat sink opal PC diffuser clear acrylic IP-65 with 25 Watt power including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete including making a hole in pillar/wall with light grade GI pipe of suitable size for fixing the post top lanter fitting complete all as specified and as directed.
S&F in repairs LED garden light (Bollard) light fitting luminaries of 10 Watt in Mashroom Shape of 3000K with IP 65 & complete all accessories including necessary connection of suitable size wire complete all as specified and as directed.
S&F in repairs LED Building security light fitting 40W on existing bracket in replacement of old unsv existing security light fitting of any type complete all as specified and as directed.
S&F in repairs GI bracket of suitable size for fixing of LED security light fitting, bracket is atleast 1.5 mtr long to be fixed on pole and it has to be bend in 45 degree angle to install the LED security light fitting including necessary welding work and MS fastner, clamp with strip complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 50 sqmm, 3.5 core including taking out old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking out old unserviceable cable complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 25 sqmm, 3.5 core including taking out old unserviceable cable complete all as specified and as directed.
M&L for excavation of trench not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for poles, stay assembly and laying cable etc and getting out in soft/loose soil including cutting of road and refix same as tarcoal as original position complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering consolidation complete all as specified and as directed.
Supply and laying old size brick coveringcommon burnt clay building bricks sub class 'B' designation 75 of size 230x115x75mm including taking out old unservicable bricks complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer n.exc 25 cm in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point in any type of soil complete all as specified and as directed.
Supplying and laying including taking out G.I. tubing light grade for encasing LT cables for mechanical protection, laid under plinth/ floors/ roads/ paths/ culverts or fixed on walls or concealed in walls or along the steel poles incl bends/clamps and all accessories size of 40 mm bore complete all as specified and as directed.
M&L for Boring holes under road pavement by bocky manually in any type of soil upto 50 mm bore complete all as specified and as directed.
M&L for taking out LT Cable 3.5 core upto 50 Sqmm size cable from the cable loop and making connection to V-TPN DB with suitable size of thimbles including necessary excavation & returning filling in and 40mm dia light grade GI protection pipe upto 50 cm length complete all as specified and as directed.
Taking down carefully the old U/S Aluminium/Copper point wiring (light, fan, socket or power) complete including fixtures such as switches, ceiling roses, pendants, sockets, regulators, etc. and making good disturbed surfaces of walls including necessary touch up the adjoining surface of disturbed area ie with OBD/colour wash/white wash etc. as per existing finish complete all as specified and as directed.
M&L for point wiring with, standard copper conductor of size 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in and including suitable concealed/existing PVC conduit medium grade and sunk in pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required colour with screws and cup washers etc. with all accessories including 1.5 Sqmm standard copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and as directed. Note :- The Rate is inclusive of cutting/chasing and making good distrubed surfaces in CM 1:3 and finished with the adjoining surfaces with ODB/colour wash/white wash as per existing complete.
All as per Srl item No.34 here-in-before, but for one light /fan/Bell point/security light controlled by one way switch
All as per Srl item No.34 here-in-before, but for one 3 pin socket outlet 5 amps on same board
All as per Srl item No.34 here-in-before, but for one 3 pin socket outlet 5 amps point independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire as power point.
All as per Srl item No.34 here-in-before, but for one 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point.
All as per Srl item No.34 here-in-before, but for one 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 sqmm as earth wire as AC point.
S&F switch piano, flush type, 5 Amps, single pole, one way complete all as specified and as directed.
S&F socket outlet, flush type, 5 Amps complete all as specified and as directed.
S&F switch piano, flush type 15 Amps single pole, one way complete all as specified and as directed.
S&F socket outlet, flush type 15 Amps complete all as specified and as directed.
S&F in repairs 0-4 step type electronic regulators for ceiling fan 1200mm sweep, 240V complete all as specified and as directed.
S&F in replairs electric bell ding dong type AC, 230 volts single phase, complete all as specified and as directed.
S&F bell push, flush type 5/6 Amps complete all as specified and as directed.
S&F in repairs Wall mounted LED Integrated Batten T5 20 Watt - 4Ft White, indoor decorative PVC extruded T5 LED battern-Integrated complete all as specified and as directed.
S&F in repairs Wall mounted LED Integrated Batten T5 10 Watt-2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete all as specified and as directed.
S&F battan holder PVC insulated body complete all as specified and as directed.
S&F in repairs LED lamp 12 Watt complete all as specified and as directed.
S&F ceiling rose surface bakelite 60x 25 mm, two to three terminals complete all as specified and as directed.
S&F in repairs wall mounting 12 Watt LED decorative wall light fixture made up of Polycarbonate, with suitable connections complete all as specified and as directed.
S&F in repairs 10 Watt LED bulk head in engineering plastic housing with clear prismatic diffuser, WHITE including all accessories, connecting up twin core flexible copper conductor cable complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
verma enterprises
Chaudhary Constructions
ramveer Singh
J V ENGINEERS / JAI SINGH
Vijeta Solutions
M/S Parmod Johar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .