Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹6.3 Cr
EMD Value
₹6.3 L
Closing Date
16 Oct 2026, 5:30 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MS PRIYANKA SHARMA(DFLT)
CHIEF ENGINEER ( TENDER CELL)
NIT 1207 Renewal / Strengthening Road Under MMGSY-MGL-M-18 , District-Mungeli
200820
NIT 1207 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-MGL-M-18 , District-Mungeli
RESTRICTED TENDER
WORKS
PERCENTAGE
8 days
CHIEF ENGINEER ( TENDER CELL)
Required Past Technical Experience: As per Tender document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
15 documents required · 15 mandatory
Panchayat and Rural Development (PARD)
WORKS
MS PRIYANKA SHARMA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CHIEF ENGINEER ( TENDER CELL)
TENDER CELL
CGRRDA RAIPUR
120
08
No
1
200820
16 Oct, 2026 5:30:00 PM IST
22 Oct, 2026 5:40:46 PM IST
1 Oct, 2026 6:30:00 PM IST
NIT 1207 Renewal / Strengthening Road Under MMGSVY PKG No MMGSY-MGL-M-18 , District-Mungeli
NIT 1207 Renewal / Strengthening Road Under MMGSY-MGL-M-18 , District-Mungeli
632000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
63156000.00
2
22 Oct, 2026 5:30:54 PM IST
63156000
AS PER NIT
AS PER NIT
As per Tender document
5000.00 INR
14d 22h 26m
15 documents required · 15 mandatory
₹5,000
₹6.3 L
1 Oct 2026
1 Oct 2026
22 Oct 2026
1 Oct 2026
22 Oct 2026
Cutting of branches of trees shrubs and trimming of grass and weeds Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914
Scarifying Existing Granular bituminous Surface to a Depth of 100 mm Scarifying existing granular/bituminous surface upto a depth of 100 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. Approx. (specify RD )
Compacting Original Ground / Existing Embankment. Loosening, Levelling and Compacting original ground/existing embankment/supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
(i) Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) Construction of granular sub-base by providing well graded material having CBR 20 or more, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100KN static weight to achieve the desired density, complete as per Technical Specification Clause 401. For Grading mentioned in table 400.1 (Grading III)
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR more than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.For Item No.3.12(a) & (b).
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 10) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
Wet Mix Macadam:-Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Restoration of Rain Cuts Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and technical specifications Clause 1902
Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 ( on wbm patch and wmm portion)
Tack Coat Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Macadam Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504 Bitumen(S-65) VG-30
20mm thick Open-Graded Premix Carpet using Bituminous (VG/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of aggregate 13.2mm size (passing 22.4mm size sieve & retained on 11.2mm sieve and 11.2mm size (passing 13.2mm sieve and retained on 5.6mm sieve) either using penetration grade/ VG bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508., Viscocity grade (VG) Bitumen specification as per IS 73:2006 (II) Bitumen (VG-30) For over all length (A)
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510, Viscocity grade (VG) Bitumen specification as per IS 73:2006
Cautionary, mandatory, informatory direction and place identification sign boards. Semi-Reflective Traffic signs upto 0.90 sqm Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and equired message, letters, figures with reflective ngineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
White washing two coats on parapet walls of CD and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause 1915
Maintainance of hume pipe culvert by way of clearing cleaning erosion repair repairs to cracks parapet wall and protectin work as per drawing and tech sp clause 1908
Maintainance of slab culvert by way of clearing cleaning erosion repair repairs to cracks parapet wall and protectin work as per drawing and tech sp clause 1908
Maintainance of causeway by way of minor surface repairs replacing guidepost repair of flood guage removal debris providing boulders and protection work and painting as per tech sp clause 1909
Reinforced cement concrete M15 grade Guard Stone of size 200mmx200x800mm fixing in position including painting and printing etc. as per drawing technical sp and as per direction of engineer in charge
Providing & Fixing of PMGSY 'Logo' board Poviding and fixing of typical PMGSY logo board as per MoRD specifications and drawings.
(B) Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on bothsides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing "Citizen informatin board/ Maintainance informaiton board" of PMGSY project Providing and fixing of typical "PMGSY Ctizen information board with Logo as pr pord specification and drawing made of 75mm square or 75mm sia circular steel tube of 12 SWG 3.2m hight and cross member 2 nos 1m long fixed with angle iron 50x50x50 mm MS angle on the back
Road marking with Hot Applied ThermoRoad marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.)on turning and approach
Executive Engineer
PIU, CGRRDA, Mungeli
Block :-
Distt. :-
Description of Item
Cutting of branches of trees shrubs and trimming of grass and weeds Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914
Scarifying Existing Granular bituminous Surface to a Depth of 100 mm Scarifying existing granular/bituminous surface upto a depth of 100 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. Approx. (specify RD )
Compacting Original Ground / Existing Embankment. Loosening, Levelling and Compacting original ground/existing embankment/supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
(i) Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.
Granular Sub-base with Well Graded Material (CBR 20 or more) (Table 400.1) Construction of granular sub-base by providing well graded material having CBR 20 or more, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory rollers of 80 to 100KN static weight to achieve the desired density, complete as per Technical Specification Clause 401. For Grading mentioned in table 400.1 (Grading III)
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR more than 7) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.For Item No.3.12(a) & (b).
Construction of subgrade and earthen shoulders with approved material (Granular material having CBR not less than 10) obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
Wet Mix Macadam:-Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Restoration of Rain Cuts Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and technical specifications Clause 1902
Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 ( on wbm patch and wmm portion)
Tack Coat Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Macadam Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504 Bitumen(S-65) VG-30
Mix seal Surfacing providing,laying,and rollingof close graded premix sufacing material of 20mm thickness composed of 11.2mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to sere as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per technical specification Clause 509, Viscocity grade (VG) bitumen specification as per IS 73:2006
Cautionary, mandatory, informatory direction and place identification sign boards. Semi-Reflective Traffic signs upto 0.90 sqm Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and equired message, letters, figures with reflective ngineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
White washing two coats on parapet walls of CD and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause 1915
Maintainance of hume pipe culvert by way of clearing cleaning erosion repair repairs to cracks parapet wall and protectin work as per drawing and tech sp clause 1908
Maintainance of slab culvert by way of clearing cleaning erosion repair repairs to cracks parapet wall and protectin work as per drawing and tech sp clause 1908
Maintainance of causeway by way of minor surface repairs replacing guidepost repair of flood guage removal debris providing boulders and protection work and painting as per tech sp clause 1909
Reinforced cement concrete M15 grade Guard Stone of size 200mmx200x800mm fixing in position including painting and printing etc. as per drawing technical sp and as per direction of engineer in charge
Providing & Fixing of PMGSY 'Logo' board Poviding and fixing of typical PMGSY logo board as per MoRD specifications and drawings.
(B) Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on bothsides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing "Citizen informatin board/ Maintainance informaiton board" of PMGSY project Providing and fixing of typical "PMGSY Ctizen information board with Logo as pr pord specification and drawing made of 75mm square or 75mm sia circular steel tube of 12 SWG 3.2m hight and cross member 2 nos 1m long fixed with angle iron 50x50x50 mm MS angle on the back
Road marking with Hot Applied ThermoRoad marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC: 35. The finished surface to be level, uniform and free from streaks and holes.)on turning and approach
Executive Engineer
PIU, CGRRDA, Mungeli
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
PMGSY
Executive Engineer
PIU, CGRRDA, Mungeli (C.G.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
5423138219147850775_153496_1278507194557121433_80616_Guidelines to Bidders.pdf
NIT • 0.13 MB
1121482449494704410_200820_NIT 1207 Tender Document MMGSVY Renewal.pdf
NIT • 1.48 MB
2290437041883879878_200820_MMGSY-MGL-M-18.xlsx
BOQ • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .