Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | ₹4.9 L Quoted ₹6.4 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹7.0 L+₹55,912 (8.71%)Rejected-Finance | ₹7.0 L+₹55,912 (8.71%) | L2 | Rejected-Finance Not the lowest tenderer |
| 3 | L3₹7.4 L+₹1.0 L (16.0%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | ₹7.4 L+₹1.0 L (16.0%) | L3 | Rejected-Finance Not the lowest tenderer |
| 4 | L4₹9.0 L+₹2.6 L (39.9%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | ₹9.0 L+₹2.6 L (39.9%) | L4 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
31 Jul 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Garrison EngiDelhi Cantt 110010
Repair Replacement of Ceiling fans Geysers Exhaust Fans and connected item at Vikram Vihar Anuj Vihar and Tarapore Enclave under AGE EM S of GE South Delhi Cantt 10
2020_MES_358154_1
GE/DS-18/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
as per tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹20,000
Yes
12 Sept 2020
3 Jul 2020
3 Aug 2020
3 Jul 2020
31 Jul 2020
17 Jul 2020
4 Jul 2020 - 15 Jul 2020
Amount
Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation with required cable and testing complete all as specified and directed by Engr-in-charge Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaft where ever required complete all as specified and directed by Engr-in-charge
M&L for Rewinding of Exhaust Fan upto 450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush & shaft where ever required complete all as specified and directed by Engr-in-charge
S&F in replacement for ceiling fan/ Exhaust fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed by Engr-in-charge Make:- NBC/ SKF
S&F in replacement for fan condenser 2.5 Mfd complete all as specified and directed by Engr-in-charge Make :- Epcos/Tibcon/Havells
S&F in replacement for fan condenser 3.15 Mfd complete all as specified and directed by Engr-in-charge Make :- Epcos/Tibcon/Havells
M&L for painting of ceiling fans after cleaning all dust there after applying one coat of synthetic enamel white paint first quality by using mechnical spray including filling cavities with filler and marking of MES No. as per existing complete all as specified and directed by Engr-in-charge
M&L for replacement of exhaust fan blades for size upto 450 mm sweep as per sample complete all as specified and directed by Engr-in-charge
M&L for replacement of MS louvers suitable for exhaust fan of sizeupto 450 mm sweep as per sample complete all as specified and directed by Engr-in-charge
M&L for replacement of Ceiling fan blades (Set of 03) heavy duty suitable for 1200mm / 1400 mm sweep complete all as specified and directed by Engr-in-charge
S&F PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engr-in-charge
Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position and making electrical and water connection complete all as specified and directed by Engr-in-charge
S&F in replacement of heating element 1.5 KW of geyser 25/35 litres capacity as per sample complete all as specified and directed by Engineer in Charge. Make Micronking/Theeta/Standard
S&F in replacement of heating element 2 KW of geyser 50 litres capacity as per sample complete all as specified and directed by Engr-in-charge. Make Micronking/Theeta/Standard
S&F in replacement thermostat ( 11 inch Long) for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engr-in-charge Make Micronking/Theeta/ Standard
S&F in replacement for indicating lamp round / flat type as required of geyser 25/35/ 50 litres capacity as per sample complete all as specified and directed by Engr-in-charge.
S&F in replacement safety valve ISI marked for geyser 25/35/50 litres capacity complete all as specified and directed by Engr-in-charge
S&F in replacement safety plug for geyser 25/35/50 litres capacity complete all as specified and directed by Engr-in-charge
S&F in replacement CP connection 15mm dia 450 mm long complete with 2 Nos brass/CP nuts and washers etc for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engr-in-charge
S&F in replacement PVC connection with brass nipple 15 mm dia 450 mm long for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engr-in-charge
S&F in replacement base plate syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 25 litres capacity as per sample complete all as specified and directed by Engr-in-charge
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of geyser 35/50 litres cap as per sample complete all as specified and directed by Engr-in-charge
S&F in replacement of inner stainless tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engr-in-charge
S&F in replacement of inner stainless tank suitable for 35 / 50 Ltr storage water heater complete all as specified and directed by Engr-in-charge
S&F in replacement of FR PVC insulated copper conductor cable 1100V confirming to IS: 694 of size 2.5 Sqmm 3 core for connecting Gyser complete all as specified and directed by Engr-in-Charge.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/35/50 ltrs capacity of any make and make the shell water tight including testing complete all as specified and directed by Engr-in-charge Note:-Taking down, de-scaling, replacement of rubber gasket will be measured and paid seperatly.
S&F in replacement Rubber gasket for Water heater storage tank of any capacity as per the existing, complete all as specified and directed by Engr-in-charge
M&L for outer body suitable for 25 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge
M&L for outer body suitable for 35/50 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge
M&L for Top & Bottom cover body suitabel for 25 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge
M&L for Top & Bottom cover body suitable for 35/50 Ltrs Water storage heater made of MS Sheet as per site requirement complete all as specified and directed by Engr-in-charge
S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engr-in-charge
S&F in replacement of Metal Clad Socket 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or blue cap colour complete all as specified and directed by Engr-in-charge . Make - Legrand / Havell's / C&S
S&F in replacement of Metal Clad Plug Top 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or Grey colour complete all as specified and directed by Engr-in-charge.Make - Legrand / Havell's / C&S
S & F in replacement Sheet metal plug & socket encosure with MCB SP 20Amps, 240 V complete all as specified and directed by Engr-in-charge Make - Legrand / Havell's / C&S
M&L for sub main wiring PVC insulated FRLS single core multistranded copper conductor cable 2 Runs of 6 Sqmm for phase and neutral and 1 run of 4 Sqmm for earth wire drawn through existing concealed steel /PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and directed by Engr-in-charge Make:- Havells/Ploycab/Finolex (Note: Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length)
S&F in replacement MCB DP 63 Amps 'C' series, beaking capacity 10KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-charge .Make - Legrand / Havell's / C&S
S&F in replacement MCB SP 5-32 Amps 'C' series, beaking capacity 10KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-charge Make; - Legrand / Havell's / C&S
S&F in replacement MCCB TPN 125 Amps breaking capacity 36KA, 415 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/s S.G. BUILDERS
Chaudhary Constructions
verma enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .