Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC | ₹47.6 L Quoted ₹48.4 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹49.8 L+₹1.4 L (2.95%)Rejected-AOC | ₹49.8 L+₹1.4 L (2.95%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹49.9 L+₹1.5 L (3.20%)Rejected-AOC | ₹49.9 L+₹1.5 L (3.20%) | L3 | Rejected-AOC REJECTED |
| 4 | L5₹51.5 L+₹3.1 L (6.32%)Rejected-AOC | ₹51.5 L+₹3.1 L (6.32%) | L5 | Rejected-AOC REJECTED |
| 5 | L6₹51.6 L+₹3.2 L (6.69%)Rejected-AOC | ₹51.6 L+₹3.2 L (6.69%) | L6 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Feb 2021, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT OF CENTRIFUGAL PUMP SETS MONOBLOCK PUMP SETS AND SUBMERSIBLE PUMP SETS AND CONNECTED ACCESSORIES REPAIR TO PLUMBING SANITARY FITTINGS FOOTPATH HARDSTANDING PATH PROTECTION DRAIN IN WATER SUPPLY INSTALLATIONS AT GMS UNDER GE I GOS
2021_MES_413863_1
8000/83/20-21/0984/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
16 Feb 2021
18 Jan 2021
10 Feb 2021
18 Jan 2021
8 Feb 2021
1 Feb 2021
Amount
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for 50 mm High density polyethelyene pipes (HDPE) of pressure rating 6kgf/sqcm laid in trenches complete all as specified and directed
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.
M&L for 50 mm thick cement concrete 1:2:4 type B-1 using 20 mm gradedstone aggregate as in path/hard standing surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for forming construction joints 50 mm x 10 mm wide filled with sealing compound Grade A complete all as specified and directed
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and smooth without using extra cement as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L chequered tile of size 200 x 200 x 18 to 20mm set and jointed in neat cement slury and pointed in grey cement and pigments to match over 20mm thick screed bed in CM 1:6 complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified and directed.
Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for pre cast cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed.
M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT Bars 5 mm dia & over upto & including 10 mm dia in stirrups, spaces & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
M&L preparation of new or previously untreated steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for two coats of synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed
M&L for complete removal of existing treatment on walls and applying two coats of cement based paint complete all as specified and directed
M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed
M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L preparation of old painted surfaces of walls and applying one coat of cement based paint complete all as specified and directed
M&L preparation of old painted surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L preparation of old painted surfaces and applying one coat of anti fungal weather coat paint on walls complete all as specified and directed
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed
Demolition of existing sunken water proofing treatment/cement plaster/cement concrete any descripltion and removing the debris from site n exc 150 m from site complete all as specified and directed.
M & L for rendering 10 mm thick CM 1:3 surface as in roof with 3% integral water proofing compound by the weight of cement complete all as specified and directed
Supply only cement concrete type B1 1:2:4 (20 mm graded agg) as in padding concrete/coving for in Jn of sunken floor and vertical wall or to maintain proper slope on roof chamfored on edge complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings laid in trenches of 20 mm bore of pipe complete all as specified and directed.
S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed
S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed
Making connection of PPR distrubtion bracnch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
Taking down bib tap / wash basin tap/ pillar tap/ stop cock/ mixture tap and refixing the same after repair and replacement of washer 15 mm bore size complete all as specified and directed.Note: spindle where required will be measured and paid separately
S&F in repairs brass spindle short body of 15 mm bore complete all as specified and directed
S&F in repairs brass spindle long body of 15 mm bore complete all as specified and directed
S&F in repairs bib taps cast copper alloy with crutch or butterfly handle fancy type, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore dia of pipe complete all as specified and directed.
S&F in repair Chromoium plated angle cock, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or brass ferrule, 15 mm bore complete all as specified and directed.
S&F in repairs Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore of pipe complete all as specified and directed.
S&F in repairs for 15mm bore dia of pipe pillar taps cast copper alloy, with capstan head chromium plated screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair PVC waste pipe for urinal/WHB etc complete all as specified and directed
S&F in repairs CP 32 mm bore dia waste coupling of (half or full threaded) etc complete all as specified and directed.
S&F in repairs Chromium plated grating doom 100 m dia fixed in floor in CM 1:3 complete all as specified and directed
S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repairs PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S & F in repairs internal fitting (syphon) for low level flushing cistern complete all as specified and directed.
S&F in repairs flush pipe 32 mm dia of polyethylene of low or high density or PVC, for low level cistern complete all as specified and directed.
S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
S & F in repairs sheet Glass Shelf assembly consisting of 5.5 mm glass sheet shelf 12 cm wide with cromium plated bracket guard and railing 60 cm long complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as concreting filling and mass concrete complete all as specified and directed
Supply and fix in replacement of MCCB 3 pole , 415 V , fixed type 40 Amp panel mounting type AC, complete all as specified and directedMake – CG/HAVELL’S/ L&T/C&S.
S&F in repair Star Detla Timer 0-30 Seconds duration complete all as specified and directed make L&T/Havell's/C&S
Supply and fix in replacement CT Coil 60/5 Amps complete all as specified and directed Make : L&T/AE
Supply and fix in replacement CT Coil 30/5 Amps complete all as specified and directed Make : L&T/AE
Supply and fix in replacement of MCB TP 40 amps, complete all as specified and directed Make – CG/HAVELL’S/ L&T/C&S.
Supply and fix in replacement gun metal NRV of size 50 mm dia complete all as specified and directed Make : Kirloskar/Leader/Upadhyay/Zoloto
Carrying out Chemical analysis test of water collected from bore wells through Govt approved lab complete all as specified and directed
Supply and fix in replacement of Power factor capacitor 3 phase 415/440V 50 Hz of capacity 5 KVAR,complete all as specified and directed Make : L&T/Siemens/Havells
M & L for 5 micron 20 inch long jumbo micron catridge filter complete all as specified and directed .
M & L for Overhauling/Backwash & cleaning of the Desalination Plant at GMS with Citric Acid-10 kgs and 5 Micron Catrige Filter-04 nos including complete all as specified and directed NOTE: Every Overhauling/Backwash will be measured separately as each Job
Supply and fix in replacement contactor 400 Amps 3 pole capacity2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified & directed. Make :L&T/C&S/ HAVELLS,
Supply and fix in replacement contactor 325 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified & directed. Make :L&T/C&S/ HAVELLS
Supply and fix in replacement contactor 250 Amps 3 pole capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified & directed. Make :L&T/C&S/ HAVELLS
Supply and fix in replacement contactor 185 Amps 3 pole capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified & directed. Make :L&T/C&S/ HAVELLS
Supply and fix in replacement contactor 110 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified & directed. Make :L&T/C&S/ HAVELLS
Supply and fix in replacement of low/high voltage monitoring device 440 volts, 3 phase complete all as specified and directed Make- EAPL/L&T./Minilec
Supply and fix in replacement of phase monitoring device 440 volts, 3 phase Make- EAPL / L&T/Minilec.
Supply & fix in replacement of Dry run & over load protection with phase failure relay alongwith suitable complete all as specified and directed CTS Make : EAPL/MINILEC
Supply and fix in replacement of electronic adjustable cyclic timer complete all as specified and directed Make : EAPL /L&T/Minilec.
Supply and fix in replacement Voltmeter digital type (0-500V) complete all as specified and directed Make : AE/L&T/HPL
Supply and fix in replacement Ammeter digital type (0- 100 Amps) complete all as specified and directed Make : AE/L&T/HPL
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm dia bore well (Casing pipe size200/250mm)supply and install 3 HP, 40 mtr Head,105LPM, 38mm outlet (Model KS4C- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm dia bore well (Casing pipe size200/250mm)supply and install 5 HP, 75 mtr Head,180LPM, 50mm outlet (Model KS6B- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
M & L for supply and fixing Automatic Voltage Regulator Model as per existing suitable for 30 to 82.5 KVA KVA DG sets, starting and testing on load complete all as specified and directed
M & L for supply and fixing Automatic Voltage Regulator Model as per existing suitable for 200 to 320 KVA KVA DG sets, starting and testing on load complete all as specified and directed
M & L for servicing of Turbo charger assembly including removing of carbon blockages , replacement of oil seal and necessary bearings as per OEM concerned all as specified and directed of capacity 200 KVA to 320 KVA
M&L for draining out oil from engine of DG set of any capacity, cleaning the oil chamber, supply and filling of lubricant in replacement GENSET OIL multi-grade 20W40 complete all as specified and directed, Make- Castrol/Gulf
M&L for only filling up to top-up Engine oil into DG Set of any capacity GENSET OIL multi-grade 20W40 complete all as specified and directed, Make- Castrol/Gulf
S&F in replacement of coolant suitable for DG sets complete all as specified and directed, Make- GULF/COLDGUARD/CASTROL
S&F in replacement of Diesel filter suitable for 7.5 KVA to 30 KVA DG set capacity as per existing size complete all as specified and directed ( Make : Bosh or eqvt )
All as per item No. 114 above but 40 to 82.5 KVA capacity
All as per item No. 114 above but 200 to 320 KVA capacity
Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos and motor terminals plate/cable ducts complete of capacity 30 HP including painting complete all as specified and directed
All as per item No.117 above but of capacity 20 to 25 HP electric motor any type.
All as per item No.117 above but of capacity 10 to 15HP electric motor any type.
All as per item No.117 above but 5 to 7.5 HP electric motor any type.
All as per item No.117 above but 1 to 3 HP electric motor any type. Note for item No 117-121 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The coated rate deemed to included .
Dismantling of submersible motor upto 7.5 HP 3 phase from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of motor as per the following :- (a) Cutting out existing winding of starter of submersible motor of any make and rewinding with same size of copper winding wire as existing as directed by the EIC. (b) Straightening the slot of starter of submersible motor of any make (c) Replacement of thrust washer and bearing complete of submersible motor of any make. (d) Replacement of worn-out bushes of submersible motor as per manufacturers design and specification. (e) Replacement of sand guard (f) Providing of sleeves in end plate of submersible motor (g) Replacement of cable gormmet (h) Replacement of water seal (i) Replacement of studs with nuts (j) Lathe work of motor shaft, turning to bring it to original size and shape and plastering of shaft of submersible motor for smooth functioning on described amps
All as per item No.122 above but of capacity upto 5 HP
All as per item No.122 above but of capacity upto 3 HP Note for item No 122 to 124 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The coated rate deemed to included .
Dismantling of submersible pump upto 7.5 HP capacity from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of pumps/Testing as per the following:- (a) Replacement of coupling complete (b) Overhauling of submersible pump and carrying out the following repairs. (c) Lathe work including balancing of pump shaft and cutting of key slots (d) Re-threading of worn-out studs holes and providing over size studs with nuts (e) Replacement of bowel bushes (f) Replacement of neck ring (g) Replacement of steel distance pieces (h) Replacement of bowel (j) Replacement of head extension
Replacement of impeller upto 7.5 HP submersible pump set
Dismantling complete Centrifugal /Mono Block pump set of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement duly all as specified and tested for smooth functioning of capacity 30 HP
All as per item No. 127 above but capacity 20 to 25 HP
All as per item No.127 above but capacity 10 to15 HP
All as per item No.127 above but capacity 5 to 7.5 HP
. All as per item No.127 above but capacity 1 to 3 HP
Disconnecting the electric connection and taking out the submersible pump set from bore / open well upto 7.5 HP including GI column pipe complete and lowering down repaired motor with column pipe, welding joints and connecting electrical connection as directed and transportation of submersible pump set upto 7.5 HP 3 phase from pump house to any location in GMS area to contractors work shop repaired pump set for relowering, dismantling and carrying out necessary repairs complete all as specified and directed
Replacement of old rusted GI Column Pipe heavy grade of size 65 mm dia in pieces of 3.3 metre long , lathe m/c threaded both ends in the bore/open wells complete all as specified and directed. Make –Tata/Jindal
All as per item No.133 above but of 50 mm dia
Replacement of old rusted heavy grade GI socket of size 65 mm dia complete all as specified and directed.
All as per item No.135 above but of 50 mm dia
S&F in repair PVC insulated submerssible cable water proof flate type 3 core with standed copper conductor cable, 4 Sqmm, 1100 volts grade including cable lugs/joints, connection to submerssible motor and other end to aluminium armoured cable including jointing complete all as specified and directed (Make: Finolex /Polycab/Plaza
S&F in repair HDPE Borecaps of size 200/250mm dia complete all as directed.
S&F in repair of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire steenless steel) for holding of submersible pump motor set complete all as specified and directed.
Supply and replacement contactor 16 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZcomplete all as specified and directed. Make – CG/L&T/BCH/ HAVELL’S/Seimens.
All as per item No.140 above but 25 Amps capacity.
All as per item No. 140 above but 32/35 Amps capacity.
All as per Item No.140 above but 40/50 Amps capacity
Taking down old unserviceable and Supply and fixing Monoblock pump sets , electric driven ,Three phase suitable for suction and delavery line size 100x100 mm supply and install 15 HP (11KW ), (Model KDS 1537 ,code D1211500110, Make :KDS,kirloskar complete fiting and testing ,alignment of motor , complete all as specified and directed. NOTE: The Unsv. Pump sets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing Monoblock pump sets , electric driven ,Three phase suitable for suction and delavery line size 100x80 mm, supply and install 20 HP (15KW ), (Model KDS 2050 ,code D12012000110, Make :KDS,kirloskar complete fiting and testing ,alignment of motor ,complete all as specified and directed. NOTE: The Unsv. Pump sets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 230 v, single phase suitable for 200/250 mm dia bore well (Casing pipe size200/250mm)supply and install 1 HP ( 0.75 KW ), 80 mtr Head,0.6 cum/hr, 38mm outlet (Model CORA 75 + UMAI ( S ) of size 20B / 15 + 0.75 / 22 Make :KSB or in Eqvt including lowering by manpower & mechanical all as specified and directe NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump controller single phase 1 HP , 240 V , 50/60 HZ , start capacitor : 120-150 MFD , Coil voltage 240 V , Run capacitor : 1 x 36 MFD and relay range : 6-10 A of Cat No . SS97721 of L&T Make or its in Eqvt including necessary connections complete all as specified and directed .
Supply and fix in replacement of DOL starter for submersible pump set type MK-I and relay range 9-14 amps with contactor complete all as specified and directed. Make : C&S/L&T/CG
Supply and fix in replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed Make- CG/L&T/ BCH/C&S.
All as per item No.149 above but 15 to 22 Amps capacity.
All as per item No.149 above but 24 to 34 Amps capacity.
Supply and fix in replacement of indicating lamp set (RYB) LED type complete all as specified and directed.
Supply and fix in replacement of MCCB 3 pole , 415 V , with Microprocessor release 160 Amps with breaking capacity 36 KA panel mounting type AC, complete all as specified and directed.Make – CG/HAVELL’S/ L&T/C&S.
Supply and fix in replacement of MCCB 3 pole , 415 V , fixed type 63 Amp panel mounting type AC, complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S.
M/s Bapujee Builders and Traders
M/s Ats Electricals
MM ENGINEERING SYSTEMS
M/s TECH TEAM
R K Traders
M/s MAA BHAIRABI ENTERPRISES
ABC CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .