Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 22 BEHIND MODERN PETROL PUMP BEHIND MODERN PETROL PUMP JHALAWAR ROAD KOTA KOTA RAJASTHAN 324007 | KOTA | RAJASTHAN | 324007 | Admitted-Finance |
| 2 | Rejected-Technical NEAR RAM MANDIR VILLAGE UNDAL TEHSIL JHALARAPATAN DISTT JHALAWAR | JHALAWAR | RAJASTHAN | 326023 | Rejected-Technical The bidder does not fulfills QR |
Tender Value
₹42.3 L
EMD Value
₹84,620
Closing Date
21 Aug 2024, 11:00 amClosed
CE CTPP Chhabra
202 First Floor Admn Building Chowki Motipura CHHABRA 325220
Supply of various 16.5kV/24kV/33kV CTs and PTs for IPBD LAVT and 33KV switchyard of Unit 1 to 4 and for Bethali and Hinglot River Water pump houses CTPP RVUNL Chhabra
2024_RRVUN_394778_1
1330/2024-25(MM)
Open Tender
Electrical Goods/Equipments
Item Wise
60 days
CTPP, Motipura Chowki, Chhabra
As per uploaded tender documents
2 documents required · 2 mandatory
₹590
Account Office, CTPP, RVUN
₹84,620
Yes
18 Jan 2025
19 Jun 2024
22 Aug 2024
19 Jun 2024
21 Aug 2024
19 Jun 2024
Voltage Transformer
Single Phase Epoxy Cast Resin, Dry Type, Natural air cooled, Earthed type, Draw out type, For Indoor Use, Ref. standard: IS 3156 IL: 24/55/125 kVp Ratio: (16500/√3)/ 110V/√3/110V/√3 Burden/ Accuracy Class: Core 1 - 100 VA/0.2 Core 2 - 100 VA/3P, Insulation Class: B, Over Voltage factor-Continuous/ 30 Sec.: 1.2 times for continuous and 1.9 times for 30 Sec.
Single Phase Epoxy Cast Resin, Dry Type, Natural air cooled, Earthed type, Draw out type, For Indoor Use, Ref. standard: IS 3156 IL: 24/55/125 kVp Ratio: (16500/√3)/ 110V/√3/110V/√3 Burden/ Accuracy Class: Core 1 - 100 VA/0.2 Core 2 - 100 VA/3P, Insulation Class: B, Over Voltage factor-Continuous/ 30 Sec.: 1.2 times for continuous and 1.9 times for 8hrs
Single Phase Epoxy Cast Resin, Dry Type, Natural air cooled, Earthed type, Draw out type, For Indoor Use, Ref. standard: IS 3156 IL:36/70/170kVp PRIMARY VOLTS 33000/√3 TYPE:DES, WINDING SEC1 CONN, SECONDARY VOLTS 110/√3, VA/PH 100 V.F 1.2 Cont. & 1.9 for 8 HRS, CLASS 1.0 FREQUENCY:50 HZ, TERM a-n INSULATION CLASS:B
Current Transformer (24kV Class Bus duct)
CT Cast resin epoxy, Ring type, 1 min. HVPF withstand: 55 kV (rms) Impulse Withstand: 125 kV(Peak), Insulation Class: 24 kV Design ambient temp. : 50⁰C, Insulation class: B, Current Ratio A/A: 1000/1, Output VA: 50, Class: 5P20 CT ID (in mm.): 360 CT OD(in mm.): 575 Height (in mm.): 100
CT Type: Cast Resin Epoxy, Ring type, Nominal System voltage: 24 kV Basic insulation Level:55 kVrms/ 125 kVPeak, Insulation Class: B Short time rating:- Symmetrical: 100kA for 1 sec(Main), Momentary: 255 kA Peak, Temp rise: 40⁰C Frequency: 50Hz, Ref. Standard: IS-2705 Current Ratio: 12500/5 Output VA: 100 , Class: 0.2 S, ISF: <=5 CT ID (in mm.): 760 CT OD(in mm.): 920 Height (in mm.): 75
CT Type: Cast Resin Epoxy, Ring type, Nominal System voltage: 24 kV Basic insulation Level: 55 kVrms/ 125 kVPeak, Insulation Class: B Short time rating:- Symmetrical: 100kA for 1 sec(Main), Momentary: 255 kA Peak, Temp rise: 40⁰C Frequency: 50Hz, Ref. Standard: IS-2705 Current Ratio: 12500/5 , Knee point voltage V(>=) : 1000 V Secondary resistance at 75⁰C Ω(<=): 6 Ω Excitation current at Vk/2(<=): 150 mA Class: PS CT ID (in mm.):710 CT OD(in mm.): 900 Height (in mm.): 110
CT Type: Cast Resin Epoxy, Ring type, Nominal System voltage: 24 kV Basic insulation Level:55 kVrms/ 125 kVPeak, Insulation Class: B Short time rating:- Symmetrical: 165kA for 1 sec, Momentary: 445 kA Peak, Temp rise: 40⁰C Frequency: 50Hz, Ref. Standard: IS-2705 Current Ratio: 1000/1 Secondary resistance at 75⁰C (<=): 4 Ω Output VA: 15, Class: 5P20 CT ID (in mm.): 320 CT OD(in mm.): 520 Height (in mm.): 125
CT Type: Cast Resin Epoxy, Ring type, Nominal System voltage: 24 kV Basic insulation Level:55 kVrms/ 125 kVPeak, Insulation Class: B Short time rating:- Symmetrical: 165kA for 1 sec, Momentary: 445 kA Peak, Temp rise: 40⁰C Frequency: 50Hz, Ref. Standard: IS-2705 Current Ratio: 10000/1 Secondary resistance at 75⁰C (<=): 20 Ω Output VA: 25, Class: 5P20 CT ID (in mm.): 325 CT OD(in mm.): 565 Height (in mm.): 130
Current Transformer (33kV )
Cast resin epoxy, TYPE(DES)-33F, Nominal System voltage: 33 kV CT CORE -3 RATIO CURRENT(A) 50/1 /50/1/50/1, RATED BURDEN (VA) 15/ 15/ - CLASS OF ACCURACY 1.0/5P/PS,TYPE: WOUND, INSTRUMENT SECURITY FACTOR/ACCURACY LIMIT FACTOR ≤5/ -, IL:36/70/170kVp, RCT(75ºC)≤ Ω/ Ω/ 4Ω HSV:36kV, Vk≥ V/ V/ 160V, STC 16Ka for 1 sec, Ie AT Vk/4 ≤ mA/ mA/ 30mA, FREQ.-50 HZ, SECONDARY TERMINALS 1S1-1S2 2S1-2S2 3S1-3S2, INSULATION CLASS B
Cast resin epoxy, TYPE(DES)-33A, Nominal System voltage: 33 kV CT CORE -2 RATIO CURRENT(A) 80/1 80/1, RATED BURDEN (VA) 15 /15/ - , CLASS OF ACCURACY 0.5/ 5P20/ - , INSTRUMENT SECURITY FACTOR/ACCURACY LIMIT FACTOR ≤5/- , IL:36/70/170kVp, RCT(75ºC)≤ Ω/ Ω/ Ω HSV:36kV, Vk≥ V/ V/ V, Ith: 16Ka for 1 sec, Ie AT Vk/4 ≤ mA/ mA/ mA, FREQ.-50 HZ SECONDARY TERMINALS 1S1-1S2 2S1-2S2 3S1-3S2, INSULATION CLASS B
Cast resin epoxy, Nominal System voltage: 33 kV CT CORE -3 RATIO CURRENT(A) 100/1 / 100/1 /100/1, RATED BURDEN (VA) 30 /30/ - CLASS OF ACCURACY 1.0/ 5P20/ PS, INSTRUMENT SECURITY FACTOR/ACCURACY LIMIT FACTOR <5/ -, IL:36/70/170kVp, RCT(75ºC)≤ Ω/ Ω/ Ω HSV:36kV, Vk≥ V/ V/ V, Ith: 16Ka for 1 sec, Ie AT Vk/2 ≤ mA/ mA/ 30mA FREQ.-50 HZ, SECONDARY TERMINALS 1S1-1S2 2S1-2S2 3S1-3S2, INSULATION CLASS B
Cast resin epoxy, TYPE(DES)-33C, Nominal System voltage: 33 kV CT CORE -3 RATIO CURRENT(A) 80/1 / 80/1 /80/1, RATED BURDEN (VA) 15 /15/ - CLASS OF ACCURACY 0.5/ 5P20/ PS, INSTRUMENT SECURITY FACTOR/ACCURACY LIMIT FACTOR - ≤5/ -, IL:36/70/170kVp, RCT(75ºC)≤ Ω/ Ω/ Ω HSV:36kV, Vk≥ V/ V/ V, Ith: 16Ka for 1 sec, Ie AT Vk/4 ≤ mA/ mA/ mA FREQ.-50 HZ, SECONDARY TERMINALS 1S1-1S2 2S1-2S2 3S1-3S2, INSULATION CLASS B
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .