Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC | ₹2.1 Cr Quoted ₹2.2 Cr | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹2.6 Cr+₹41.9 L (19.2%)Rejected-Finance | ₹2.6 Cr+₹41.9 L (19.2%) | 2 | Rejected-Finance Not being lowest |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
13 Jan 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
ADDN/ ALTN TO TECH FLIGHT COMPLEX AT JORHAT
2019_MES_284510_1
88625/JOR/E8
Open Tender
Civil Works
Item Rate
365 days
GE (AF) JORHAT
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (AF) JORHAT
₹3.0 L
Yes
HQ CE (AF) SHILLONG ZONE
1 May 2020
24 Sept 2019
20 Jan 2020
24 Sept 2019
13 Jan 2020
2 Dec 2019
10 Oct 2019
Amount
Addn/ Alteration to Tech Flight Complex Design, fabrication, installation and commissioning of automatic hangar door, motor operated mild steel hangar gate of total opening size of 30m x 10m of each side door (6 leafs of each door) and bi-parted made from pre-engineered structure. Gate to be cladded with 0.5mm thick Galvalume colour coated with 550Mpa painted in approval camouflage pattern alongwith suitable size rail and rollers (inclusive of roll bearing), automation system arrangement with all connected technical equipment accessories such as tail doors and integrated pass doors without threshold , bottom rail and top guide beam, guide rollers, end stops, gate carriage, wheels, track locking arrangement, driving mechanism, supports, electric wiring, pannel control board etc in the state to achieve overall serviceable automatic hangar gate with stability, durability and robustness, a high level of translucence retaintion, quality workmanship and finished as approved by Engineer-in-charge and manufacturers instructions. Notes :- (a) Design of pre-engineered hangar gate with foundation shall be vetted by IIT for the parameters considedred revelent IS codes for operation units, braking system, controls, warning devices all as specified and directed for replaceing existing manual operated gate considering new gates will be sustained by existing supporting truss. (b) Serviceability of the hangar gate must exist even the electric supply is offline with manual arrangement for opening and closing. (c) All steel section will be painted with two coats of enamel paint over a coat of red oxide all as specified and directed. Manufacturer and supplier: TATA BULE SCOPE/ KIRBEE
Dismantling wrought iron or mild steel work of any descriprion not otherwise provided for.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed as in roofing,cladding and sliding gates.
Supply and fixing for 0.63 mm thick galvanised, corrugated MS sheeting with two corrugatings side lap, fixed with 'L' type or 'J' type or cranked hook bolts in roof, walls etc all as specified and directed.
S&F for plain sheeting 0.8mm thick galvanised with zinc coating 275gms per sqm as in ridge hips valley gutters etc fixed with 'L' or 'J' type cranked hook bolts in roof, walls etc complete all as specified and directed.
M & L for preparing new zinc(or galvanised) surfaces to receive painting , by coating with mordant solution including washing and cleaning etc all as specified and directed
M & L for preparation of New decorated surfaces of roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (camoflouge type : dimension exc 2.5 RM but not exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE), for external surfaces of sheets only.
M & L for preparation of New decorated surfaces of roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed for inner surfaces of sheets only.
M & L for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth all as specified and directed.
M & L for preparation of old painted surfaces of CGI roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (camouflouge type : dimension exc 2.5 RM but not exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE), for external surfaces of sheets only.
M & L for preparation of old painted surfaces of CGI roof sheet of any description (plain or corrugated) exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer including removing of galvanisation coating complete all as specified and directed for inner surfaces of sheets only.
Supply & fixing for wind activated roof ventilator suitable to mount on roof sheet with all necessary fixing arrangement, complete all as manufacturers instructions.Make – Horne Roof Ventilators or equivalent.
Dismantling Glazed floor, hearth or wall tiling including cement mortar bedding (but not backing coat) removing serviceable tiles and rubbish off the premises
M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular area) of each tile exceeding 0.06 Sqm but not exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed by matching cement all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertiacal surfaces 350X250X7mm or 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match.
M & L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm light shade, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M & L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm light shade, in skirting, dado and risers etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M & L 20mm thick sceed bed or bedding layer of mortar for laying tiles in CM 1:4.
M & L 10 mm thick backing coat to received tiles on vertical surfaces of brick or concrete masonry in CM 1:4
Taking down chowkhats or frames exc 1.5 Sqm but n exc 4Sqm with shutters(without taking off shutters from the frame) each
Taking down chowkhats or frames not exc 1.5 Sqm each
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain coloour PVC sheet reinforced with M.S Square tube.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottim rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement.
S&F 100mm butt hinges, medium weight, cold rolled mild steel, and fixed.
S&F 100mm extruded aluminium alloy handles fabricated type anodised .
S & F 150mm aluminium, anodised barrel tower bolt of extruded section .
Dismantling of wall and ceiling boards (fibre pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets.
S & F aluminium anodised snap grid frame work for false ceiling all as specified and directed.
S & F Minaral Fibre board tiles for insulation and acoustic purpose 60 X 60 cm in size fixed with nails or staples on snap grid.
Hangars 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long and expansion hold fastners 12.50 mm dia 40 mm long complete all as specified.
Taking up or down GI tubing and connections including cleaning for re fixing or removal to store for 15 mm dia pipes
All as per item No. 31 above but for 20 mm dia pipes
M & L GI tubing 15 mm dia galvanised medium grade with all fittings and fixed complete to walls and ceilings ar laid in floors etc complete.
All as per item No. 33 above but for 20mm dia only.
S & F vitreous China wash basin white flat back size 630 x 450 mm excluding taps, waste chain and plug and porcelain stopper but including bracketes fixed.
Pillar taps, cast copper alloy, with cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type.
S & F 15 mm bore bib tap fancy type chromium plated capstan head screwed down,screwed for iron pipe complete all as specified and directed.
S & F vitreous China bowl urinal flat back of size 465 X 355 white with grating and union for discharge pipe fixed in repair including waste pipe complete all as directed by Engineer-in-Charge.
S & F concussive push button taps of cast copper alloy, 15 mm bore screwed for iron pipe /PVC connection.
S&F PVC connections 15 mm size with PTMT nuts by length 450 mm.
S & F Vitreous china wash downwater closet pan semi pedestal pattern white fixed in repair all as directed.
S & F vitreous china squating pan, Orissa pattern of size 580 X 440 mm white with integral foot rusts all as directed.
S&F platic water closet seat, for EWC, closed pattern with flat bottom, and cover and MS chromium plated or aluminimum hanging devise.
S & F toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws.
S & F PVC valveless syphonic action type flushing cisturn low level, white with inlet ball valve float valve and handle including brckets 10 ltr capacity.
S & F 15mm bore consealed stop valve fancy type chromium plated screwed down high pressure screwed both ends for iron pipe all as directed.
S & F 40 mm dia high density polyethylene pipes of pressure rating 6 Kgf/Sqcm laid in floor/trenches all as specified.
S & F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors.
S & F 180mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls.
S & F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (minimum weight 190gms).
Demolition of brick work built in Cement Mortar including all quoins, arches, pillars, etc. of any descriptions, keep serviceable bricks in safe custody for re-use, complete all as specified and as directed.
M&L for Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 m mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
Taking down cement plaster any description brick/ concrete surfaces all as directed.
M&L rendering 10mm thick cement plaster C M 1:6 on fair faces of concrete or brick surfaces to finished with smooth and even without using extra cement.
M&L for rendering 15mm thick in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces, plastered surfaces finishing fair and even, complete all as specified and as directed.
M & L Dismantling timber scantlings 40 sq. cm and over in section, in any position as in frame work all as specified and directed.
M & L Second class hard-wood in scantlings in frame work as clean sawn all as specified and directed.
M & L preparation of new painted wood and wood based surfaces of any description exceeding 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Taking down/ demolishing plaster on lathing (with wire netting) without removing lathing cement mortar plaster all as specified and directed.
S&F wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in wall ceiling stanchion beams etc including all laps cutting and waste.
M&L lath plastering 15mm thick in Cement Mortar 1:6 on one ide of lathing, finishing plastered surfaces even and smooth without using extra cement, complete all as specified and as directed.
M&L lath plastering 20mm thick on other side of lathing in two layers, 1st layer 12mm thick in Cement Mortar 1:4 and 2nd layer 8mm thick in Cement Mortar 1:4, finishing plastered surfaces even and smooth without using extra cement including mixing of water proofing compound (WPC) as per manu-factuerer’s instructions, complete all as specified and as directed.
M & L for applying 2 coats oil bound distemper over a coat of primer including wall care putty on new plastered surface of walls.
All as per item No. 64 above but for old surfaces of wall including removal of old treatment complete all as specified and directed.
M & L for preparation of newly plastered surfaces on walls over 10 cm width or girth and applying two coats of acrylic base exterior paint over a coat of primer as per manufacturers instructions (camoflage type : dimension exc 2.5 RM but not exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE)).
M & L for preparation of old decorated/ painted concrete surfaces on walls over 10 cm width or girth and applying two coats of acrylic base exterior paint over a coat of primer as per manufacture instructions (camoflage type : dimension exc 2.5 RM but not exc 3 mtr in each direction (length and breadth) of each irregular shaped area painting with difference tint (as approved by GE)).
M & L powder coated anodised aluminium door shutters with frame, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and as directed.door shutter with frame including 5mm thick tinted glass, 12mm thick pre-laminated board of colour choice, handle, locking arrangement etc complete with floor spring and all fittinngs and fixture all as specified and directed.
M & L for powder coated anodised aluminium window and ventilator shutters with frame, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinge type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified and as directed. Aluminium glazed window shutter sliding type with frame including 5mm thick plain/ tinted (for ventilator) glass, handle, locking arrangement, Daco grill (DG-102) complete all as specified and directed.
M&L 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
M&L 5 mm thick plain colour PVC prelam sheet in strips & channel feathered at the edges for fixing on solid PVC wall lining, insulated PVC Wall lining and solid PVC partitions inclusive of solvent cement and fixing at site.
Internal_Electrification Taking down copper/ aluminium point wiring (light, fans, socket or power) complete, incl fixtures and fittings such as switches, ceiling roses, light fittings, regulators, socket, pendants etcremoving materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition saperately) and making good disturbed surface of wall/floor etc complete all as specified and directed.
M & L for point wiring with 1.5 Sqmm FRLS grade PVC insulated cable 1100 volts grade as per IS-694 stranded copper conductor cable drawn through and including PVC casing and caping (not less than 20 mm wide) complete with all fittings and acessories including MS sunk box of thickness 1.6mm and hylem sheet cover of 3 mm thick for mounting of switches, sockets, regulators, etc and 1.5 sq mm stranded copper conductor cable FR grade PVC insulated for earth continuity all as specified and directed for one light / Fan Point controlled by one Switch.
(a) One light point controlled by one way switch
(b) One Ceiling fan/ exhaust fan controlled by one way switch
(c) One bell point controlled by one way switch
(d) all as per Ser item No 73 above but for 5 amps socket point on independent board.
(e) all as per Ser item No 73 above but for 5 amps socket point on same board controlled by another switch.
All as per Ser item No 73 above but with 2.5 sqmm cable for 15 amps socket outlet on independent board complete all as specified and directed.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body. Make:- Anchor Cat No. 39040, Havells Cat No.AHLHXCW000 or equivalent.
Supply and fix switch piano flush type, 6 Amps 240 volts single pole one way. Make:- Anchor Cat No. 14111, Havells Cat No. Reo-AHESXXW061 or equivalent.
Supply and fixing switch Bell Push type single pole.
Supply and fixing Electric bell Ding-Dong type single phase 230 volts.
Supply and fix socket outlet, 5 pin 6 Amps, flush type. Make :- Anchor Cat No. 14304, Havells Cat No. Reo-AHEKPOW063.
Supply and fix socket outlet 6/16 Amps, 6 in 1, flush type. Make :- Anchor Cat No. 14307, havells Cat No. Reo-AHEKCWW253 or equivalent.
Supply and fix switch piano flush type,15/16 Amps 240 volts single pole one way. Make :- Anchor Cat No. 14401 Penta Power Switch, Havells cat No. Reo-AHESXXW201 or equivalent.
Supply and fix 20 watt Led fitting included led channel, suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with cable of size 0.5 Sqmm (nominal area) of Make : Bajaj Cat part no BCLSB 20 WH ,or equivalent model in Havells / Crompton Greaves / Philips.
S & F recess mounted LED ceiling light fitting, 2 x2 ft, 230V, 50 Hz complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with sutable size including lamp duly fixed in the false ceiling with necessary arrangemet screws/fastners etc complete all as specified. Make : Cat No. BZRSQL 36W GZ1 CW of Bajaj or equivalent in Havells/Philips
S&F compact building security light luminaire 25 watt LED light as per Cat No. of BCLST 25W LED IV2) Bajaj or equivalent in CG/Philips/Havells including bracket made out of 40 mm light grade GI pipe not less than 1.2m, ISI marked duly fixed with MS clamps of 3 mm thick- 2 Nos, nut, bolts etc complete all as specified and as directed.
Supply and draw submain wiring with two single core 6 sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into PVC conduit and all necessary fittings including 6 sqmm multi strand FR PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed.
Supply and draw submain wiring with two single core 16 sqmm FR PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into PVC conduit and all necessary fittings including 16 sqmm multi strand FR PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good disturbed surface complete all as specified and directed.
Supply and fix SP&N DBs, double door, 240 volt, 8 way complete all as specified and directed. Make:- Legrand cat No. 607711, Havells Cat No. DHDPSHODRW08, C&S Cat No. CSDBSPNDDA2+08, Indo Asian Cat No. NSPN0008.
Supply and fix VTPN DBs, double door, 415 volt, 4 way complete all as specified and directed. Make:- Legrand /, Havells
S&F MCCB 4 pole 100 A 16 KA
M&L for MCB single pole, and neutral 240 volts, 32 Amps, 10 KA.
M&L for MCB single pole 240 volts 6 to 32Amps.
Earthing complete all shown as electrical plate No -03 of MES Sch part -I as specified and as directed including the following:- (i) GI earth plate of size 60x 60cm x6.0mm thick burried directly in ground vertically to a depth not laess than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.50 metres below ground level. (ii) Earth plate surrounded by and packed with charcoal and common salt in alternative layers. ( n.exc 15 cms each layer) (iii) 4 mm GI wire from earth plate to MCB DB including necessary GI bolts, nuts check , washers, thimbles etc. (iv) 20 mm bore, light grade, Gi pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontaly to the earth pit. (v) 15 mm dia bore G. I. medium grade pipe for protection of earth wire. (vi) Cement concrete chamber of PCC (1:3:6) type C-2 using 40mm graded stone aggregate. The chamber shall be constructed one metre away from edge of earth pit. (vii) 50 mm thick precast cover of reinforced cement concrete(1:2:4) type B-1 using 20mm graded stone aggregate with steel rainforcement 8 mm dia mild steel TMT bar @ 10 Cm c/c both ways and MS angle iron 50x50x6mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces with suitable handle to lift the cover. (viii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance of 50 m as directed.
Material and Labour for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, with universal colour code in & including instove enamelled steel conduit concealed 20 mm dia external ISI marked in Sunk pressed steel terminal boxes & providing 3 mm thick flameproof laminated sheet top cover including earth wire of PVC insulated unsheathed copper conductor of 1.5 Sqmm s/c multistranded green colour, making good the disturbed surfaces in cement mortar 1 : 3, if required (Switch/Bell/ Socket /Regulator are to be measured and paid separately) complete all as specified & directed (a) One light point/fan point controlled by one flameproof switch.
All as per Ser item No 98 above but with 2.5 sqmm cable for 15 amps Flameproof socket outlet on independent board complete all as specified and directed.
S&F LED tubelight fitting, flameproof, 1X16 W/ 20 W LED tubelight fixture including all accessories pre-wired and connecting up with twin core twisted flexible copper conductor and IP-65 protection. Make- Crompton EXTN1LT8- 16/20 or equivalent.
Supply & fix Flameproof WP Exhaust fan 450 mm sweep complete all as specified and as directed. Make: Sudhir Cat Pt No EF/140 or equivalent in Crompton/Havells
Material and labour for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as directed by Engr-in-charge Make:- Sudhir or equal with safety certificate of CMRI
Supply & fix of FLP-WP switch socket & metalic top plug combination in LM- 6 material rating 25 Amps, 250 V, 2 pole plus earth with plug including necessary fixing arrangement & all out going electric connection complete all as specified and as directed. Make: Sudhir.Cat no. SS/OA/1010-1 or equivalent in Crompton/Havells
Taking down ceiling fan/ exhaust fan of any type /size and deposited to E/M store yard.
Supply and fix ceiling fans AC single phase 230 of size 1200 mm sweep with electronic regulator comlete all as specified and as directed. Make : C.G Cat part no ALPHABRIZ1200 OPW-WOR 220/240V 50 Hz AC or equivalent in Bajaj/Havells
Supply and fix exhaust fan AC single phase 230 of size 300 mm sweep comlete all as specified and as directed. Make : C.G Cat part no Trans Air 12"- Reversible 300 MM Grey or equivalent in Bajaj/Havells
External_Electrification / DG Set Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230 mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
S&F Sub-Class B brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm aggregate) as in foundation for pole etc.complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm aggregate) as in coping/stay of pole etc. including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and as directed.
M & L 50mm bore, low density polyethylene pipe (LDPE) of pressure rating 6 kg/cm2 laid in trenches or fixed to poles/walls etc, for cable protection complete all as specified and directed.
Taking up out of trench Old, damaged XLPE under ground cable of size Sqmm 3.5 core 50 sqmm.
Supply and lay cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core.
Supply and lay cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5core.
Boring of holes under road , pavement , hard standing by trenchless manual auguring including reinforced concrete pipe, Class NP3 of bore 250 mm as specified by Engineer-in-Charge.
Supply, install, Testing & commissioning self supporing indoor type totally enclosed LT Feeder Pilaar Box of size not less than 1500 mm x 1500 mm x 750 mm, IP - 65, compartmentalised design, dust and varmin proof of suitable size suitable for 440 Volt 3 phase 4 wire system made out of 2.00mm thick CRCA sheer and buid upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated & nuts, bolts, and washers etc.The panel shall be painted with two coats of red oxide primer and final finish of sythetic enmelled gray paint and incomming/outgoing cable hole at the bottom. The Panel shall be emmbeded with 50 x 5 mm MS angle iron frame and 30 cm above the normal ground level completewith PCC foundation (1:2:4) type B2 complete all as specified and directed by Enge in charge.(Loc : Near Radar Plateform) Note : All intenal connection of MCCB from BUS Bar made by using Aluminium busbar of rated capacity. (a) Aluminium bus bar 250 amps - 04 Nos, supported with suitable sze of heavy duty PVC stand lock with suitable size od brass nuts, bolts and washer with heat shrinkable PVC sleeving. the bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 160 amps, 415volts, 25KA Breaking capacity 4 pole connected to bus bar as incoming - 01 No. OUTGOING (c) MCCB 100 amps, 415volts, 25 KA Breaking capacity 4 pole connected to bus bar as out going - 03 No.
M & L for earthing complete with galvanised steel plate electrode 60cmX60cmX 6mm thick, burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less tahn 1.5 m below normal ground level, connected to galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 03 in SSR Part- I 2009 connected to earthing test opint including test block all as specified complete with excavation and earthwork, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10 mm MS rod) 20 mm dia GI pipe medium grade ISI marked watering pipe with GI funned with wire mesh 40 mm bore GI pipe medium grade ISI marked for protection of earth lead conductor all as specified and as directed and testing on completion.
M & L for earthing with copper earth plate electrode 300X300X3 mm thick burried directly in ground vertically to a depth of not less than 2.25 m below ground level connected to copper strip of size 20X3 mm as earthing lead by means of nuts, bolts and washers made out of galvanised iron mild steel and 32 mm dia GI pipe light grade for protection of earth lead and connected to test point or as directed including PCC pit in cement concrete 1:3:6 (20 mm grade stone aggregate) reinforced with and including 8 mm dia TMT bars @ 100 mm c/c both ways, galvanisd iron wire mesh, funnel, galvanised iron watering pipe 20 mm bore medium grade, necessary excavation in soft/ loose soil, returning filling and removal of surplus soil upto a distance of 50 m all as shown in electrical plate No 05 of SSR Part- I and testing on completion, complete all as specified and directed by the Engineer-in-Charge.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recesss or chases or buried in ground or drawn in conduict/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm galvanised iron strip
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recesss or chases or buried in ground or drawn in conduict/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20X3 mm copper strip.
S&F on load change over switch 415 volts 50 HZ of capacity 250 A , four pole complete . Make Cat No. IHCNFE0250 of Havells or equivalent L&T/ABB
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 100 KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Jorhat and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 with following: (i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/ BS Standards design. Alternator :- Standard design alternator rated at 100 KVA at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. Starting System :- Electric Self starter with and including battary charging alternator 12 Volts DC. Batteries :- Batteries of maintenance free of capacity 12 V, 150 AH- 01 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified.
Control Panel :- Control panel shall be made out of CRCA sheet 14 gauge/ 2 mm powder coated dust and vermin proof totally enclosed and consisit the following: (a) Microprocessor based generator set monitoring and control system consists of 16 Charactor 2 line LCD disply and to monitor operator interface, fault history, alternator data, Engine data, provision for service adjustement and caliberation of DG control functions, Engine controls,engine protective functions, alternative protective functions etc. (b). Instrument fuses and control wiring. (c). Indication lamps for Set running and load on. (d). Aluminium bus bar copper bus bar including suitable capacity of MCCB , including CTs etc. AMF Panel :- Automatic Mains Failure (AMF) Panel made of CRCA sheet 2 mm thick including necessary arrangement to Install, Testing & Commissioning & connecting to load cable upto changeover switch , suitable capacity of 4 pole MCCB complete all as per OEM reccommendatition. Acoustic Enclosure:- Manufactured by OEM suitable for 100 KVA DG Set. Civil_Works:- All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer.
Rubber mat 1 meter x 2 meter x 10mm
Air_Conditioning S&F commissioning and testing air cooled split unit indoor/outdoor complete with cordless remote control unit and with in built air inoiser and plasma filter for better indoor aire quality with 1.5 TR, BEE 5 star rated all as specified and directed by Engr-in-charge.
S&F commissioning and testing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed.
M&L for submain wiring including PVC casing caping 2 run 4 Sqmm cable PVC insulated copper conductor multi-stranded or FRLS cable drawn through PVC casing caping with all accessories including 2.5 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and all as specified.
M&L for sheet metal enclosures with plug top and MCBs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32A capacity all as per directed, Make - Legrand/Havells/Standard all as specified and directed by Engr-in-charge.
M&L for feather - kites special coated wall mounting Stand suitable for 1.5 to 2.0 TR split AC outdoor unit consisting of brecket 2 Nos, L- angle - 02 Nos, M8 x 50 mm anchor fastener - 06 Nos
S&F commissioning and testing air cooled split unit indoor/outdoor complete with cordless remote control unit and with in built air inoiser and plasma filter for better indoor aire quality with 2.0 TR, BEE 3 star rated all as specified and directed by Engr-in-charge.
S&F commissioning and testing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
Note: Schedule of cedit (Sch 'A' Part- II) amount of Rs 413520.00 shall be deducted from the total quoted amount of BOQ.
M/S PAUL CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .