Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-Finance | ₹1.5 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹1.8 LRejected-Finance VILLAGE P O TIKKARI TEHSIL CHIRGAON DISTT SHIMLA HP | ₹1.8 L | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.8 LRejected-Finance | ₹1.8 L | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | MANDEEP KUMAR L1 | NITISH KUMAR L2 | JAI KRISHAN L3 |
|---|---|---|---|---|---|---|
| 1.00 | P/L suitable size coper PVC insulated armoured power 3*13mm square copper cable confirming to BIS 1554 (Part-I)- 1988 or latest with up to date ammendments siemen/ Gloster/ICC make from meret of HPSEB to OCB to busher switch and starter (one cable carrying all Three phases) including all other electrical equipment/accessories such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. the type, size and make will be subject to approval of HPSEB authorities it shall have to be replaced by the tenderer free of cost. | 30 | Rmt | 1,600 ₹48,000 | 1,780 ₹53,400 | 1,860 ₹55,800 |
| 2.00 | P/L suitable size coper PVC insulated armoured power 3*10mm square copper cable confirming to BIS 1554 (Part-I)- 1988 or latest with up to date ammendments siemen/ Gloster/ICC make from switch to starter and starter to motor (one cable carrying all Three phases) including all other electrical equipment/accessories such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. the type, size and make will be subject to approval of HPSEB authorities In case of non acceptance by HPSEB authorities it shall have to be replaced by the tendrer free of cost. | 30 | Rmt | 1,000 ₹30,000 | 1,400 ₹42,000 | 1,460 ₹43,800 |
| 3.00 | P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment. | 1 | Job | 26,000 ₹26,000 | 28,560 ₹28,560 | 28,650 ₹28,650 |
| 4.00 | Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. | 2 | Unit | 5,200 ₹10,400 | 5,470 ₹10,940 | 5,840 ₹11,680 |
| 5.00 | Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments. | 2 | No | 2,300 ₹4,600 | 2,580 ₹5,160 | 2,680 ₹5,360 |
| 6.00 | P/L suction,delivery pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii).NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge | 1 | LS | 35,000 ₹35,000 | 38,560 ₹38,560 | 37,500 ₹37,500 |
Tender Value
₹1.3 L
EMD Value
₹2,652
Closing Date
27 Jan 2026, 11:00 amClosed
Executive Engineer
JSV Division Rohru
Sub Head R R of common header with all allied accessories
2026_HPIPH_126292_1
No.JSV-RD-AB-Tnd/2025- 6679-6740 dt 20.01.2026
Open Tender
Civil Works
90 days
Rohru
Tender Document
8 documents required · 8 mandatory
₹500
Yes
EE Rohru
₹2,652
Yes
13 Mar 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
P/L suitable size coper PVC insulated armoured power 3*13mm square copper cable confirming to BIS 1554 (Part-I)- 1988 or latest with up to date ammendments siemen/ Gloster/ICC make from meret of HPSEB to OCB to busher switch and starter (one cable carrying all Three phases) including all other electrical equipment/accessories such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. the type, size and make will be subject to approval of HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size coper PVC insulated armoured power 3*10mm square copper cable confirming to BIS 1554 (Part-I)- 1988 or latest with up to date ammendments siemen/ Gloster/ICC make from switch to starter and starter to motor (one cable carrying all Three phases) including all other electrical equipment/accessories such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. the type, size and make will be subject to approval of HPSEB authorities In case of non acceptance by HPSEB authorities it shall have to be replaced by the tendrer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L suction,delivery pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii).NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.02 MB
F7and8.pdf
Tender Documents • 2.82 MB
F6.pdf
Tender Documents • 0.06 MB
termandcondition.pdf
Tender Documents • 0.24 MB
BOQ_186166.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid