Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹45.8 L Quoted ₹46.8 L | L1 | Accepted-AOC BEING L-1 BIDDER |
| 2 | L2₹48.1 L+₹1.3 L (2.73%)Rejected-Finance | ₹48.1 L+₹1.3 L (2.73%) | L2 | Rejected-Finance Being Other than L-1 Bidder |
| 3 | L3₹49.3 L+₹2.4 L (5.16%)Rejected-Finance | ₹49.3 L+₹2.4 L (5.16%) | L3 | Rejected-Finance Being Other than L-1 Bidder |
| 4 | L4₹51.2 L+₹4.3 L (9.25%)Rejected-Finance | ₹51.2 L+₹4.3 L (9.25%) | L4 | Rejected-Finance Being Other than L-1 Bidder |
| 5 | L5₹52.0 L+₹5.2 L (11.0%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹52.0 L+₹5.2 L (11.0%) | L5 | Rejected-Finance Being Other than L-1 Bidder |
| Sl No | Description | Qty | Unit | R J ENTERPRISES L1 | M/S. KISHAN ENGINEERING L2 | M/s Bapujee Builders and Traders L4 | M/s M M Engineering Systems L3 | cooltech engineering services L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out Window type ACs from existing locations at any height and including providing transporting and technicians for carryout of repairing works,servicing and overhauling of any capacity 1.0/1.5/2.0TR of any make/type by replacing unserviceable Compressor,Evaporator,condenser, condenser coil,valves,blower.thermostat. fan motor,air filters and other parts from the machine including charging of refrigerant gas after vacumming making system leak proof. Brazing the suction/discharge tubes where required and cleaning of condensor assembly/cooling soil unit. Brazing, gas welding and jointing,fabricating works for outer cover and base plate with extra sheet metal etc.Changing of wirings with proper size PVC insulated wires as directed. Install the Air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of JE/Engr- in - charge.
Note: (i) All old unsv credit materials should be deposited in MES yard day wise after completed of the job, the same material will be issued to contractor through gate pass as schedule of credit against contract agreement. (ii) Spares will be measured and paid separately as supply only items (iii) Charging of refrigerant shall be measured and paid seperately. | 1 | Each | 1,400 ₹1,400 Lowest | 1,520 ₹1,520 | 1,590 ₹1,590 | 1,575 ₹1,575 | 1,680 ₹1,680 |
| 2.00 | Carrying out pressure leak test for detecting leak in condensing unit, refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs for 72 hours of leak pipe including transporting carrying out T&P required at work site for window type of capacity1 .5/2.0 TR AC complete all as sbecified and directed. | 1 | Each | 950 ₹950 | 1,060 ₹1,060 | 1,150 ₹1,150 | 1,065 ₹1,065 | 860 ₹860 Lowest |
| 3.00 | Charging of Refrigerant gas suitable for Window type Air Conditioner after cleaning of condenser unit, evoporator unit, brazing suction/discharge tubes where required with suitable size of copper tubes, vaccuming, making system leak proof and achieve proper cooling effect afiter charging of refrigerant complete all as specified and directed | 1 | Each | 1,200 ₹1,200 Lowest | 1,450 ₹1,450 | 1,485 ₹1,485 | 1,465 ₹1,465 | 1,369 ₹1,369 |
| 4.00 | Supply only the following items of window type Air Conditioner (Provisional) to incorporate in item No.1 complete all as specified and directed.
(a) Running capacitor 30/45/50/60/80 MFD 230Volts, 50 Hz suitable for 1/1.5/2T WIAC Make: KELTRON / USHA SIEMENS/Annapurna. | 1 | Each | 340 ₹340 Lowest | 390 ₹390 | 400 ₹400 | 415 ₹415 | 385 ₹385 |
| 5.00 | All as per item no. 4 but for Starting capacitor 80-100 MFD/100-120 MFD 230 Volts Make KELTRON/USHA/SIEMENS | 1 | Each | 380 ₹380 Lowest | 410 ₹410 | 425 ₹425 | 425 ₹425 | 410 ₹410 |
| 6.00 | All as per item no. 4 but for Box type relay suitable for window type AC make Sriram model SR 1622 or equivalent | 1 | Each | 410 ₹410 Lowest | 490 ₹490 | 495 ₹495 | 515 ₹515 | 500 ₹500 |
| 7.00 | All as per item no. 4 but for Thermostatic switch suitable for Window type AC 1/1.5/2.0 TR Make: INDFOS
RENUTRAL IAnnapurna/Baba | 1 | Each | 460 ₹460 Lowest | 520 ₹520 | 540 ₹540 | 540 ₹540 | 525 ₹525 |
| 8.00 | All as per item no. 4 but forUniversel Strainer filter cum dryier suitable for 1/1.5/2.0 TR AC | 1 | Each | 340 ₹340 Lowest | 370 ₹370 | 375 ₹375 | 385 ₹385 | 370 ₹370 |
| 9.00 | All as per item no. 4 but forBlower Motor with blade assembly complete, single phase 230 Volts 1500 RPM, suitable for 1/1.5/2.0 TR window type Air conditioner make AUE/USHA equivalent | 1 | Each | 1,650 ₹1,650 Lowest | 1,990 ₹1,990 | 2,085 ₹2,085 | 2,005 ₹2,005 | 2,030 ₹2,030 |
| 10.00 | All as per item no. 4 but for Supply only In replacement fan motor capacitor 4/6 MFD for AC complete all as specified and direte Make KELTRON/USHA/SIEMENS/Sarda | 1 | Each | 280 ₹280 Lowest | 320 ₹320 | 330 ₹330 | 330 ₹330 | 305 ₹305 |
Tender Value
Refer Docs
Closing Date
7 Jul 2026, 6:00 pmClosed
GARRISION ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
COMPREHENSIVE MAINTAINANCE OF DOMESTIC COOLING APPLIANCES SPLIT, CASSETTE ACS AND TOWER ACS REFRIGERATORS, WATER COOLERS, DEEPFREEZERS AND VOLTAGE STABILIZERS AND CONNECTED ITEMS AT ZONE A UNDER GE(I) GOS
2026_MES_772056_1
GE/GOS/TOK/37 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GOS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GARRISION ENGINEER I GOS
Exempted
4 Sept 2026
13 Jun 2026
13 Jul 2026
13 Jun 2026
7 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out Window type ACs from existing locations at any height and including providing transporting and technicians for carryout of repairing works,servicing and overhauling of any capacity 1.0/1.5/2.0TR of any make/type by replacing unserviceable Compressor,Evaporator,condenser, condenser coil,valves,blower.thermostat. fan motor,air filters and other parts from the machine including charging of refrigerant gas after vacumming making system leak proof. Brazing the suction/discharge tubes where required and cleaning of condensor assembly/cooling soil unit. Brazing, gas welding and jointing,fabricating works for outer cover and base plate with extra sheet metal etc.Changing of wirings with proper size PVC insulated wires as directed. Install the Air conditioner at location where directed after proper repair and testing complete at site as per the satisfaction of JE/Engr- in - charge.
Note: (i) All old unsv credit materials should be deposited in MES yard day wise after completed of the job, the same material will be issued to contractor through gate pass as schedule of credit against contract agreement. (ii) Spares will be measured and paid separately as supply only items (iii) Charging of refrigerant shall be measured and paid seperately. | 1 | Each | - | - |
| 2 | Carrying out pressure leak test for detecting leak in condensing unit, refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs for 72 hours of leak pipe including transporting carrying out T&P required at work site for window type of capacity1 .5/2.0 TR AC complete all as sbecified and directed. | 1 | Each | - | - |
| 3 | Charging of Refrigerant gas suitable for Window type Air Conditioner after cleaning of condenser unit, evoporator unit, brazing suction/discharge tubes where required with suitable size of copper tubes, vaccuming, making system leak proof and achieve proper cooling effect afiter charging of refrigerant complete all as specified and directed | 1 | Each | - | - |
| 4 | Supply only the following items of window type Air Conditioner (Provisional) to incorporate in item No.1 complete all as specified and directed.
(a) Running capacitor 30/45/50/60/80 MFD 230Volts, 50 Hz suitable for 1/1.5/2T WIAC Make: KELTRON / USHA SIEMENS/Annapurna. | 1 | Each | - | - |
| 5 | All as per item no. 4 but for Starting capacitor 80-100 MFD/100-120 MFD 230 Volts Make KELTRON/USHA/SIEMENS | 1 | Each | - | - |
| 6 | All as per item no. 4 but for Box type relay suitable for window type AC make Sriram model SR 1622 or equivalent | 1 | Each | - | - |
| 7 | All as per item no. 4 but for Thermostatic switch suitable for Window type AC 1/1.5/2.0 TR Make: INDFOS
RENUTRAL IAnnapurna/Baba | 1 | Each | - | - |
| 8 | All as per item no. 4 but forUniversel Strainer filter cum dryier suitable for 1/1.5/2.0 TR AC | 1 | Each | - | - |
| 9 | All as per item no. 4 but forBlower Motor with blade assembly complete, single phase 230 Volts 1500 RPM, suitable for 1/1.5/2.0 TR window type Air conditioner make AUE/USHA equivalent | 1 | Each | - | - |
| 10 | All as per item no. 4 but for Supply only In replacement fan motor capacitor 4/6 MFD for AC complete all as specified and direte Make KELTRON/USHA/SIEMENS/Sarda | 1 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
tender_docs.pdf
Tender Documents • 1.47 MB
BOQ_864524.xls
BOQ • 1.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .