| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.9 LAccepted-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.9 L+₹1.0 L (2.80%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance L2 | |
| 3 | L3₹37.2 L+₹1.3 L (3.52%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹39.0 L+₹3.1 L (8.65%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹73,400
Closing Date
22 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
AF STATION UDHAMPUR
PROVISION OF INFRASTRUCTURE FOR TACAN RADAR, INSTALLATION OF GO NO GO LIGHTS AND GUN STATUS LIGHTS IN NEW ATC TOWER AND PROVISION OF EXTERNAL SERVICES AND ASSOCIATED WORKS FOR INTEGRATED FIELD SHELTERS (IFS) AT AF STATION UDHAMPUR
2023_MES_577107_1
GEAFU-64/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
AF STATION UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹73,400
Yes
6 Mar 2023
25 Jan 2023
24 Feb 2023
25 Jan 2023
22 Feb 2023
8 Feb 2023
31 Jan 2023 - 2 Feb 2023
Amount
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, complete all as specified and directed.
Removing of excavated material exc 1.50 Km but n.exc 5Km and deposited where directed at a level not exc 1.5 m above ground complete all as specified and directed.
M&L for PCC type D-2,1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed
Reinforced Cement Concrete M-25 Design mix ( using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete, all as specified and directed.
Reinforced Cement Concrete M-25 Design mix ( using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, all as specified and directed.
Reinforced Cement Concrete M-25 Design mix ( using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, all as specified and directed.
Reinforced Cement Concrete M-25 Design mix ( using 20 mm graded crushed stone aggregate) as slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, all as specified and directed.
Reinforced cement concrete M-25 Design mix (using 20 mm graded crushed stone aggregate) as in chajjas complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, plinth beams, and similar work,with rough finish surfaces ofconcrete flat complete all as specified and directed.
Form work to sides of pillars, posts sturts, piers, columns and stanchions , rough finished surface of concrete complete all as specified .
Form work to sides of soffits of floors or roof beams, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc. rough finished concrete surface of concrete complete all as specified and directed.
Form work to soffits of RCC suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, rough finished surface of concrete, complete all as specified and directed.
Form work to chullah hoods, chajjas and similar items including edges, rough finished surface of concrete complete all as specified and directed.
M&L TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for 15mm thick plastering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement but using integral water proofing compound as per manufacturer's instructions, complete all as specified and dorected/ Note : Integral water proofing compound shall be measured & paid for separately under relevent item.
M&L for 15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed.
M&L for Preparation of new plastered surfaces of wall and applying two coats of acrylic distemper, complete all as specified and directed.
Material & labour for preparation of new plastered wall surfaces and applying two coats of Cement Base paint(Camouflage Paint) complete all as specified and directed.
Preparing plastered or unplastered new surfaces of ceiling and applying two coats of white washing, all as specified and directed.
Supply only water proofing compound conforming to IS 2645-1975 complete all as specified and directed.
M&L for Hardcore of gauge not exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 ( using 40mm graded crushed stone aggregate) as in subbase to floors/path, finished even and fair complete all as specified and directed.
M&L for 50 mm thick cement concrete Type C-2,1:3:6 ( using 20mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
S&F Pressed steel frames for doors made out of 1.25mm thick MS sheet with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate ,12mm bar threshhold etc. complete, of frame size 165 x 60 mm, including one shop coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for PCC Type B1,1:3:6 for filling to Pressed steel chowkat complete all as specified and directed.
Supply and fixing 2nd class hard wood 35 mm thick factory made plain framed paneled shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces including mouldings fixed to chowkats, complete all as specified and directed.
Supply and fixing 2nd class hardwood 35 mm thick factory made glazed and skelton shutters to receive glass/ gauge of with sash bars for windows/ventilators fixed in position complete all as specified in SSR Part-I Sec 8 clause 8.20(B) complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Preparation of new wood or wood based surfaces of any description not otherwise described exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
S&F Butt hinges, medium weight,cold rolled mild steel,size of hinges 75 mm complete all as specified and directed.
S&F Extruded aluminium alloy handle, fabricated type, anodised, 150 mm long (ISI marked), complete all as specified and directed.
S&F aluminium sliding door bolt plate type 250 mm long stove enamelled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified .
S&F Steel ventilators with top hung shutters including box type hinges, steel peg stay complete and a shop coat of red oxide zinc chrome primer complete all as specified and directed.
S&F steel window with side hung shutter incl. box type hinges with steel handle,tower bolt & steel peg stay complete with glazing bars,dovetailed or welded complete all as specified and directed.
S&F steel window with side hung shutter incl. box type hinges with steel handle,tower bolt & steel peg stay complete without glazing bars dovetailed or welded complete all as specified and directed.
S&F MS work as in grills,gratings etc with ends of bars shouldered or riveted framed guard bars barred Iron doors,ladders conforming to Fe-410-0-or 310-0 complete all as specified and directed.
M&L 3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
M&L 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
Preparation of new steel and iron surfaces not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for rendering 10 mm thick on RCC slab / concrete surfaces in CM 1:3, finished even and smooth without using extra cement including mixing of water proofing compound complete all as specified and directed. Note : Integral water proofing compound shall be measured & paid for separately under relevent item.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube supplying & Fixing in opening as per specification complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frmae made out of M.S tubes for top&bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail,lock rail &bottom rail on either side as gap insert for top rail & Bottom rail as per specification complete all as specified and directed.
M&L for glass dividing strips 3 mm thick 38 mm wide inserted in position complete all as specified and directed.
M&L for 40 mm thick PCC type B-0 1:2:4, using 20mm graded crushed stone aggregate as in sub base finished fair for receiving floor finishes complete all as specified and directed.
M&L non-skid coloured ceramic tiles(Square/Rectangular) area of each tile exceeding 0.06 sqm but not exc. 0.11 sqm ,7-8 mm thick in floors etc set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed bedding layer of 15 mm thick in CM 1:4 complete all as specified and directed.
M&L for ceramic glazed coloured tiles as in vertical surfaces such as skirting ,dados etc with area of each tile 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface incl. 10 mm thick plaster in CM 1:4 complete all as specified and directed.
M&L for steel water tubing (15mm) medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings ( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 15 mm complete all as specified and directed.
S&F Angle cock with wall flange size 15mm complete all as specified and directed.
S&F pllar taps, cast copper alloy, with capstan heads, chromium pated, screwed down highj pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F 15 mm plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified.
S&F health faucet (15mm) mild steel body with wall hook and 1.25 Mtr. SS braided rubber hose pipe with complete accessories Complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 300mm complete all as specified and directed.
S&F in 32mm dia PVC waste pipe with cap socket suitable for 32 mm waste coupling complete all as specified and directed.
S&F 32 mm brass waste coupling with ceramic pop-up push type(full thread) 1
S&F in vitreous china wash down water closet pan (pedestal pattern), white complete all as specified and directed.
S&F PVC(SWR) pipes single sockets, in any length with rubber rings joints laid in trenches or in floors, 110mm dia complete all as specified and directed.
ditto but 75mm dia complete all as specified and directed.
S&F PVC (SWR) junction single (T) equalor unequal 110mm bore with oval access door complete all as specified and directed.
S&F PVC (SWR) bends any radius 75 mm bore with oval access door complete all as specified and directed.
M&L PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified and directed.
S&F 75 mm size (SWR) floor trap,plain with gratting including jointing with solvent cement complete all as specified and directed.
S& F PVC vent cowl 75 mm dia complete all as specified and as directed.
S&F vitreous china wash basin, white, flat back, size 450x300mm excluding taps, waste, chain and plug but including brackets size complete all as specified and directed
S&F in PVC low level twin type flushing cistern 10 ltr capacity including flush pipe complete all as specified and directed.
Cutting existing 20 mm size steel tubing for alterations or additions(or lengthening screw on pipe to form connector) complete all as specified and directed.
M&L for rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) hoisted and fixed in position of 500 Ltrs complete all as specified and directed.
S&F Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed.
S&F Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwde both ends for iron pipe or for unions and fixed 20 mm bore complete all as specified and directed.
S & F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed 20 mm bore complete all as specified and directed.
M&L for 15 mm dia steel water tubing, medium grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L fo providing precast cement concrete 1:2:4 type B1 (20mm graded aggregate) solid building blocks or slabs 10cm cm thick (with plain or interlocking joints as directed) setting in CM 1:6 as in foot path edging complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:4:8 type D2 (40mm graded aggregate) as in subbase, complete all as specified and directed.
M&L for sand cushion below the flooring including watering & consideration complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS - 15658-2006 of 80mm thickness M-40 grade with gray cement and pigment complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type of soil complete all as specified and directed.
Excavating over areas, n. exc 1.5M deep and getting out hard/ dense soil complete all as specified and directed.
All as per item No 83.00 above but each additional 1.5m or part thereof in depth beyond the first 1.5m complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with 20mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed.
Precast cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
Loose filling with broken bricks aggregates of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and directed.
M&L for PCC 1:3:6 Type C2 (using 40mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100mm bore complete all as specified and directed.
All as per item No 88.00 above but 150mm bore complete all as specified and directed.
M&L reinforced concrete pipes Class NP2, 100mm internal dia drain pipes laid in trenches and jointed with collar complete all as specified and directed.
All as per item No 90.00 above but 150mm dia complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L for screwing existing steel tubing, cutting existing steel tubing for alterations or additions (Each cut measured) of dia 25 to 50mm complete all as specified and directed
Rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Stop valves of dia 25mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
Stop valves of dia 50mm, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through in concealed conduit of suitable size ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and directed Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and directed Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
S&F Switch modular type 6 AMP, one way , one module conforming to IS-3854 complete all as speciified and directed
S&F Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and directed.
S&F Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and directed.
S&F Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and directed.
S&F Modular electonic fan regulator 2 module rotary step type 230 volts complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make : Crompton/Bajaj/Khaitan
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, making good disturbed surface complete all as specified and directed.
Supply and install HOT and COLD type invertor split AC Copper wound wall mounted indoor/outdoor complete with cordless remote control unit of 1.5 Ton 3 star, cooling capacity 5200 watt heating capacity 5600 watt, R-32, refrigerant, low indoor noice less than 48 dB, dust filter air purifier stabilizer free operation, Cu connecting pipe length upto 5 Mtr/connecting cable upto 5 mtr all incluing outdoor unit mounting bracket making holes in wall and making good complete all as specified and as directed by Engr-in-Charge. Make : Voltas, Blue Star or its equivalent.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
S&F AC Voltage Stabilizer wall mounting with low and high voltage cut off, thermal overload protection, intelligent time delay system capacity 15 Amp, voltage working range 130-280 Vac, time delay 3 minute +/- 20 Sec ITDS if capacity 4 KVA, 230 Volts, 50 Hz complete all as specified and directed
M&L for Single pole and neutral enclosure with a two pin and earth plug and socket of capacity 20 Amp complete with one single pole MCB complete all as specified and directed
S&F LED light fitting mirror type with high out put diffuser 4 feet, 20 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED light fitting 1 x 9 W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 4 way TPN with 200 Amp rated bus bar 230 volt AC supply including accessories therein complete all as specified and directed. Make:HAVELLS / SIEMENS/Schneider
S&F MCB three pole & neutral of 415 Volts 50 Hz 63 Amps rating with rupturing capacity not less than 16 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc including accessories therein complete all as specified and directed. Make: HAVELLS / SIEMENS/Schneider
S&F MCB single pole, 6-32 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including accessories therein complete all as specified and directed.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1. following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 35 mm 3.5 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 25 mm 3.5 core laid on walls/floors/trenches or in air with saddles and gutties complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply & laying GI Tubes, 'Medium grade of 25 mm dia, with all fitting (such as bend, tee, union, elbow etc) in trenches complete all as specified and directed.
Supply & laying GI Tubes, 'Medium grade of 20 mm dia, with all fitting (such as bend, tee, union, elbow etc) in trenches complete all as specified and directed.
M & L for Gun-metal, globe or gate valves of size 20 MM dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Cutting the existing GI/CI/MS pipe of 100/50 mm bore and inserting CI/MS Tee of size including all fittings, welding/lead joints and earthwork all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed.
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed.
Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified and directed. Note :- Thickness of sand cushioning shall be the thickness after punning down 18 cm.
Supply and fixing switch piano flush type single pole, one way 6 Amps IS-3854 complete all as specified and directed
S&F Switch socket combination 5 in 1, 16 Amp flush type universal type, conforming to IS-3854 complete all as specified and directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit heavey duty drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface and disposing from site complete all as specified and directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
S&F LED lights fitting 1x 20WLED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy box type four feet with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells Cat Part No HEXAWP7IN1W020 or its equivalent to Bajaj/CG
S&F XLPE insulated copper armoured cable 10 Sqmm 5core , PVC tape sheathed for multicore cables 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed complete all as specified and as directed
S&F PVC conduit 40mm pipe suitable for cable protation including clips Elbow screws nuts bolts drilling of hole walls drains making good condition complete all as specified and as directed.
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes of any size upto 01 mtr. Depth and getting out incluiding forming bottom surface to required level and making good the road as per existing bitumens , concrete all as specified and directedby EIC.
Drilling/boaring (horizontally) upto 150 mm bore by penumatic tool or horizontal boaring/drilling machine under the existing road (max. 40 mtr. In width) suitable for passing GI/CI/DI tubing complete all as specified and directed.
MCB distribution board having IP-54 protection, powder coated, Single door, flush mounted complete with locking arrangement suitable for 12 way SPN with 200 Amp rated bus bar 230 volt AC supply including accessories therein complete all as specified and as directed
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB)SPN 40 Amps complete all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) SP 6- 32 Amps complete all as specified and directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 mm x 200 mm and 50 mm deep complete all as specified and as directed .
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and as directed .
S&F Socket shuttered outlet 2/3 pin, 6 Amp, modular type, 2 modules complete all as specified and as directed.
S&F LED Green lamp with maximum wattage 5 watt (lumen output not less than 700 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink complete all as specified and directed.
S&F LED Red lamp with maximum wattage 5 watt (lumen output not less than 700 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink complete all as specified and directed.
S&F LED White lamp with maximum wattage 5 watt (lumen output not less than 700 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Sub class 'B' old size bricks well burnt as covering to under ground cables, laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair, complete all as specified and directed.
M&L plain cement concrete (nominal mix) 1:4:8 type D-2 using 40 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
S&F GI Tubes, 'light gradegalvanised, PIPE 40 mm bore for with cable protation laid in trenches/pole complete all as specified and as directed
M&L plain cement concrete (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed
M&L for GI tube light grade of bore 50 mm with all fittings and fixed complete to walls and ceiling or laid in floor/trenches for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed.
M&L for GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor/trenches for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3 1/2 core all as specified and directed.
S&F cable jointing kit for 1100 KV grade cable for end joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 sqmm x 3.5 core sqmm,Indoor/Outdoor type complete all as specified and directed.
S&F cable jointing kit for 1100 KV grade cable for end joint complete with Jointing material heat Shrinkable type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm, Indoor/Outdoor type complete all as specified and directed.
M&L for cutting of Road and Concrete surfaces upto 1.0 m depth and 500 mm wide for laying of cable / pipe in any type of soil, returning and filling in and spreading, leveling, watering and well ramming in layers not exceeding 25cm thick removal of surplus soil and provision of 150 mm thick PCC type B-1, 1:2:4 with 20mm graded crushed stone aggregate on top layer all as specified and as directed.
Supply, installation, testing and commissioning of cubical compartmentized outdoor type LT panel vermin proof, weather proof, front and rear door openable with locking arrangement fabricated out of 3.15 mm thick CRCA sheet steel and base channel of size not less than 90 cm long and suitable for operation on 415 volts, 50 Hz Ac supply with switchgear & suitable frame work/support made out of MS Section of size 50 x 50 x 6 mm, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm completeaccessories as given below complete with pad locking sealing arrangement earthing stud lebeling, painting, inter/connections providing of danger plates etc as per specifications and comprising with following:- BUS BAR CHAMBER :- (a) 400 Amp insulated copper strip of length not less than 60 cm and size not less than 50x6 mm for 03 phase and neutral, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Volt Meter, 96X96mm, flush type rated 0-500V, with Volt meter push button type- 01 Set. (ii) Digital Amp Meter, 96X96mm, flush type rated 0-250A, with Amp meter push button type- 01 Set. (iii) C.T's 250/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (iv) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three).B8 Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. INCOMING SUPPLY :- (i) MCCB 250 Amps 25 KA ,ICS 100% of ICU, 0.8 ln to 1 ln, 4 Pole with Thermal Magnetic trip, adjustable type overoad setting, 415 volts , frequency 50Hz,=01 No+B10 OUTGOING SUPPLY :- (i) MCCB 160 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 100 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=02 Nos., (ii) MCCB 63 Amps 16 KA , 4 Pole with Thermal Magnetic 415 volts , 50Hz,=01 Nos. Make of MCCB:-L&T/ Siemens / Legrand The panel manufacturer should have following Govt. Approved Certificates: 1. Panel shall be installed at least 45 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates 3. Drawing of panel shall be got approved from GE.
M&L for Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1. following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Voltage stabilizer for automatic operation ,three phase naturally oil cooled indoor type and designed for input varition between 340 Volts to 460 volts with output voltage stabilized at 415 with accuracy +- 2.5 % and speed of correction 8 volts per second and of capacity 25 KVA complete all as specified and directed by Engineer-in Charge. Note :-panel cover of size as required at site .
K S BUILDERS
KARAN TRADERS
ANIKET TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .